We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 4
-1 SERVER NOT FOUND
The specified server does not exist.
-2 INVALID CONNECTION A handle has been specified which is outside the legal range of values. -3 ALGORITHM NOT FOUND There are no available licenses on the network with the specified developer ID or algorithm. -4 OUT OF HANDLES All servers for this identifier are out of handles. Usually, this means there are no available licenses on the network with the specified developer ID or algorithm. It may also mean that the handle limit configured for one or more servers is lower than the sum of the limits of the attached keys. To correct this, restart the server with the /H option. -5 HANDLE ALREADY LOCKED This key is already locked (by the same or another user). -6 HANDLE LOCKED Another user has placed a lock on the key (using Lock Key). Queries from other users are inhibited until that lock is removed. -7 INVALID FUNCTION The specified function is not a valid NetSentinel interface function. -8 INVALID UNIT The specified key is not connected to the server. -9 RPC ERROR A network error occurred. This may mean that the server you were connected to is no longer reachable. -10 ALGORITHM NOT FOUND There are no available licenses on the network with the specified developer ID or algorithm. -11 OUT OF HANDLES All available handles for this application have been used. -12 NO NETSENTINEL SERVERS No security servers can be found on this network. -13 BAD HANDLE The handle you specified is not assigned to any current license. -14 NO MORE KEYS No other NetSentinel keys with this developer ID or algorithm and a free license can be found on the network. -15 HANDLE LOCKED Another user has placed a lock on the key (using Lock Key). Queries from other users are inhibited until that lock is removed. -16 HANDLE ALREADY LOCKED The key is already locked (by the same or another user). -17 SERVER DIED The server to which you were connected failed to responde. It may be disconnected from the network. -18 SERVER PROTOCOL The server does not support communications with your NetSentinel user library (version mismatch). -19 NETWORK INIT An error occurred during network initialization. -20 SERVER NOT FOUND The specified server does not exist. -21 CANNOT CONNECT A network error occurred while trying to connect to the server. -22 SERVER BUSY All communication threads for the server are in use. This error is returned only if you have specified non-blocking mode; by default, a busy server is retried automatically. -23 KEY REMOVED The server has detected that your security key has been removed from a parallel port and replaced by a different key. -24 USER BUSY The DLL is already processing a call with this user handle. This error can occur if the "Yield To Windows" option is enabled using the Set Rainbow Windows Parameters function. -25 TASK TABLE FULL The DLL is being used by too many applications. -26 API ERROR Either the department name is illegal or the max server number is out of range. -27 INVALID REQUEST Incorrect parameters have been passed to Set Rainbow Library Parameters. -28 INVALID HANDLE TABLE REQ The number of handles specified is smaller than the size of the current table. The handle table can grow larger but never smaller. -29 MEMORY ALLOCATION ERROR A request to allocate memory from the operating system has failed. -30 VERSION NOT SUPPORTED The user loader you are using does not support the version of linked-in NetSentinel code in your application. -31 LOADER NOT INSTALLED In the WATCOM interface (Loader version), the loader was not used to load the client application. -32 UNSUPPORTED PROTOCOL The user library you are using does not support the specified protocol. -33 OPTION NOT AVAILABLE You have called Access sub license with a session handle which does not reference a NetSentinel-C key. Sub-licensing is only supported on the NetSentinel-C. -34 MAX LICENSE REACHED You have attempted to open a sub-license at a time when all sub-licenses are already in use. -35 LICENSE TABLE FULL The NetSentinel server's sub-license table is full. Re-start your server using the /SL�:nnnnn command line option, where nnnnn is the maximum number of sub-licenses you expect to be open by all users at any one time (the default value is 256). -36 KEY REMOVED A key containing one of your currently open sub-licenses has been removed. -37 KEY CONTENT CHANGED The sub-licensing configuration of one of your keys has been changed. You must always bring down the security server before changing the contents of a sub-licensing key. -38 OUT OF RANGE You have specified a sub-license number whose value is within legal limits (0-56) but which is greater than the largest sub-license number defined in any of your keys. -39 NOT IN USE You have attempted to close a sub-license which is not currently open. -40 INVALID ASLCMD You have specified an invalid command code in Access sub license. -41 RSP PTR NULL You have supplied a null response buffer address (0000) in an ASL_GET_INFO command. -42 INVALID SUBLICENSE You have specified a sub-license number greater than 56 in Access sub license. -43 FUNC NOT AVAIL LOCAL The function specified is not valid for local mode. -44 INIT THREAD ERROR Initialization of user thread process failed. Virtual memory may be running low. Freeing up virtual memory by shuting down other tasks may resolve the error. -45 INIT SEMAPHORE ERROR Initialization of semaphore failed. Virtual memory may be running low. Freeing up virtual memory by shuting down other task may resolve the error. -46 INIT PROTOCOL ERROR Protocol failed to initialize. Either the entire transport or part of the transport may be missing or is configured incorrectly. -47 BAD HANDLE The handle you specified is timed out or the handle value is corrupted. -48 GET LIB PARAMS ERROR An general error occurred when calling Get Rainbow Library Parameters. This may mean it failed to get the NetSentinel OS/2 system driver status. -49 INVALID LIB PARAMS FUNC The specified function is not a valid Get Rainbow Library Parameters or Set Rainbow Library Parameters function. -50 INVALID KEY TYPE The specified key type was not NetSentinel-Pro nor NetSentinel-C. -51 SET LIB PARAMS ERROR An general error occurred when calling Set Rainbow Library Parameters. -52 DRIVER CONFIGURE ERROR An error occurred while trying to configure the NetSentinel system driver. -53 GET DRIVER INFO ERR Failed to get NetSentinel system driver information. -54 INIT RDP ERR An error occurred during NetSentinel system driver initialization. -55 HANDLE NOT FOUND The handle you specified is not assigned to any current license. -56 TASK NOT FOUND The current task/application cannot been found in NetSentinel task table. -57 BAD OFFSET You have specified a handle greater than maximum number of licenses. -58 KEY CORRUPTED Found Invalid data in key. -59 DRIVER READ ERROR An error occurred while reading the key. -896 / FC80 The NetSentinel-C may be in the middle of an operation and cannot start another operation. Alternatively, there may not be a NetSentinel-C attached to LPT1. -897 / FC7F The software is corrupted. Try reloading the software from the release diskette. If the problem persists,contact Rainbow Technologies. -898 / FC7E The software is corrupted. Try reloading the software from the release diskette. If the problem persists, contact Rainbow Technologies. -899 / FC7D Port LPT1 is malfunctioning, does not exist, or has had its address removed by some other software. If the port cannot be repaired, use a different computer. -993 / FC1F The requested command is not valid. Refer to the list of valid commands provided in the Rainbow user's guide. -994 / FC1E No NetSentinel-C key can be detected. Make sure the key is securely connected to port LPT1. Retry the operation in case there is a hardware problem causing intermittent access failures. -995 / FC1D The requested command has one or more invalid parameters. Make sure the parameters are in the correct order, that each parameter is within the proper range, and that there are no extraneous characters. -997 / FC1B You are trying to output to the key, but did not enter the correct Read or Write password.