A.03 Tank
A.03 Tank
A.03 Tank
R 100 4-200 DISTANCE REQUIRED FOR SEPTIC strength of 25N/mm^2 at 28days with 20mm maximum
TANKS AND SOAKWAYS aggregate size.
R 100 B - 250 B
R 100 7-250 B
R 100 7-250 B
R 100 7-250 B
MINIMUM DISTANCE FROM SEPTIC SOAK WAY 4. REINFORCEMENT
(a) High Yield bars to be square twisted cold formed bars to
BUILDING 1.5 3.5 BS4461 and are marked 'Y'on these drawings.
PROPERTY BOUNDARIES 1.5 1.5
WELLS 3.00 3.00 (b) Mild steel bars Marked 'R' on these dwgs to be round bars
C CUTS OR EMBARKMENTS 7.5 3.00 to BS 4483.
C WATER PIPES 3.0 3.0 5.MINIMUM COVER TO ALL STEEL IN
05-200 B 05-200 B LARGE TREES 3.0 3.0 (i) Foundation, stubcolumns, column bases & ground beams =40mm
(ii)Beams =25mm
(iii) Slabs = 40mm
FOR DIAMETER UP TO 3.00 USER 10, 290mm c/c
SEPTIC TANK REINFORCEMENT FOR DIAMETER UP TO 3.50M USER10, 290MM C/C
(iv) Columns =30mm
ARRANGEMENT ARRANGEMENTS OF REINFORCEMENT AS SHOWN (v) Bot. slab =20mm
200
5 50 4100 2100 1500 12.92
COMPANY CONTACT
WATER PROOF FILLING
600
PLAN TO SEPTIC TANK B 450X450mm MIN CAST IRON MANHOLE HEIGHT OF WATER LEVEL
7
8
75
85
4600
4900
2300
2400
1800
1800
19.35
21.93
Email [email protected]
100mm MOSQUITO PROOF
COVER OR COVER OR CONCRETE Contact Number-0753240500
CONCRETE SLAB 9 130 5500 2750 2200 33.54
GAUGE VENT PIPE
City-Bagamoyo
Country-Tanzania
BAR BENDING SCHEDULE
MIN 300
HEIGHT VARIABLE
02 " R10 100 100 Phone.
DEPTH VARIABLE
7 1.5 1.8
R10 - 250 SEALED CESSPIT TO BE USED WHEN SOIL CONDITIONS FALLS 15 1.7 1.85
30 2.1 2.0
Drawn by Date
BELLOW THE MINIMUM PERCOLATIONS FACTOR AND
DISTANCE TO THE NEAREST SEWER IS VERY FAR 40 2.35 2.1 Brown Alfred Nziku 03.May.2023
DRAINFED TRENCHES PREFERRED TO SOAKAGE PITS IF SPACE 50 2.61 2.2
PERMITS 60 2.85 2.3
200
APPLICATION CAN BE MADE TO THE AUTHORITY FOR 75 2.23 2.45 Checked by Date
CONNECTION TO LOCAL SEWER 85 3.5 2.5 Eng. Alatupoka mgeni
VARIES
MASS OR REINFORCED CONCRETE WALL CAN BE USED 2. FOR NON POROUS SOILS EG CLAY AND WHERE WATER
INSTEAD OF BLOCKS TABLE IS VERY HIGH OTHER MEANS OF DISPOSAL e.g Layout ID Revision
SECTION B-B THE TANK SHALL BE OF WATER TIGHT CONSTRUCTION SEWER CONNECTION MUST BE APPLIED
REINFORCED CONCRETE RENDERED WITH WATER PROOFED POWDER OR OTHER 3. ALTERNATIVELY THESE DIMENSIONS (IN PARTICULAR THE A.03
APPROVED MATERIALS DIAMETER)MAY BE DOUBLED TO CREATE LONGER
RETENTION
PERIOD DUE TO INFILTRATION
GSPublisherVersion 0.6.100.100