Smoke Detector I-9102


The integral microprocessor analysis the
signal according to the factors such as
signal strength and rate of increase, then
confirms these pattern with the pre-
programmed fire scenarios and smoke
patterns for a faster and safer response. By
intelligent analysis, the smoke detection
sensitivity will be automatically adjusted
according to temperature change,
providing a rapid response.

Secure and speedy communication through


the on board processor enables the
detector to make its own decision, resulting
in greater automation. The sensor and the
panels utilized fuzzy logic providing an
almost limitless cause and effect scenarios.

Drift compensation, to monitor for the long


term changes caused by aging, humidity,
temperature, dust, etc. constant
Features and Benefits monitoring and self adjusting, the I-9101
updates sensitivity base line for its sensing
1. Built in 8 bit microprocessor element. Even when the detector raises a
2. Algorithm maps for faster response warning advising that it requires cleaning,
and false alarm rejection the sensitivity remains the same as the day
3. Analogue sensing it was installed.
4. Secure and speedy communication
5. Intelligent Linear Drift compensation Electronic addressing can be done through
6. Self diagnosis and history log Handhold Programming device (P-9910),
7. Electronic addressing purchased separately.
8. Sensing chamber for exceptional dust
Technical Specifications
proof ability
9. Twin LED for 360º vision
• Standard: EN54-part7
10. Built-in remote indicator output
• Approval: LPCB,CE
11. Low profile design
• Protection rating: IP 32
• Operating voltage: 24Vdc Loop
Description
voltage
• Operating Current:
The I-9102 Optical Smoke Detector is the
• Standby current 0.6mA
ideal device for most application due to its
• Alarm Current 2mA
excellent linear response to a wide variety of
• Operating temperature: -10°C to
different type of smoke patterns. The unit
+50°C
meets the sensitivity requirement of EN 54
• Relative humidity: 95%
part 7, European Standard and approved by
• Application: Indoor use
Loss Prevention Certificate Board (LCPB).
• Detecting range: 100 sqm elevated
than 6m, 80 sqm less than 6m
Aesthetically pleasing with a low profile
• Field Programmable sensitivity:
design, unobtrusive to complement modern
0.10dB/m to 0.56dB/m – 3 level
building designs. The unit incorporates an
• Visual Indicator: twin LED, Red ( lit
intelligent processor that provides Algorithm
steady when alarm, 3 sec interval
map, Built-in A/D converter, Drift
blinking at normal state)
compensation, Self Diagnosis and history log.
• Material and colour: ABS, off-white
• Wiring: 1 pair non polarized
• Dimensions: diameter 10cm; height
5cm
Intelligent Optical
Smoke Detector I-9102 CONCRETE PAD OR
HOLDING PAD
EMBEDDED BOX

Mounting Standard Base


The detector is mounted using our standard MARK−LINE 2ND MARK−LINE
base DZ-03.Multiple-direction design allows
easy direction adjustment. Suitable for
surface mount only, mount on standard
1gang electrical back box with a mounting LED INDICATOR

hole of 65mm spacing ROTATE CLOCKWISE

CONCRETE PAD OR EMBEDDED BOX


HOLDING PAD
SCREW Programming
The address of the detector and sensitivity
HOLE
can be programmed using GST handhold
STANDARD DETECTOR BASE
programmer (P-9910), purchased
separately. Connect the two wires of the
BASE MOUNTING handheld programmer to terminals 1 and 3
of the detector.
Wiring and Connection
Connect the wires to the required terminal
according to the wiring diagram below;
terminal 1 and 3 for the loop; connection of
remote indicator output is on terminals 2 and
I−91XX
4. The cable must be fire rated type and the DETECTOR

size depends on the distance and application.


Minimum size gauge 1.0mm²(18 AWG)

DETECTOR TERMINAL

FIELD DEVICE PROGRAMMER

TERMINALS

TO NEXT DEVICE
1 PAIR FIRE CABLE Selection of compatible Control Panels
1 2 Compatible with all GST Intelligent Fire
FROM CONTROL PANEL Alarm Panels GST 100, GST 200, GST 5000
and GST 9000.
1 PAIR FIRE CABLE

4 3
REMOTE INDICATOR

Ordering Information:
Part No Description Weight Pack
Detector Installation /Kg Qty
per
The Intelligent optical smoke detector should
Box
be installed in compliance with all local codes
I-9102 Intelligent 0.123 120
having a jurisdiction in your area or NFPA 72 Optical Smoke
National Fire Alarm Code, NFPA 70 National Detector with
Electrical Code, BS 5389 and EN54. Before Remote
installation verify the proper wiring and base Indicator
are firmly mounted to prevent detector DZ-03 Standard 0.050 360
damage before the installation. Point the Detector Base
detector in the base by the mark-line and
secure the detector in that position by
rotating it clockwise until it reaches the next MANUFACTURED IN ACCORDANCE WITH
mark line.

Note: Specifications are subject to change without notice.