1 A 1

Particulars 2 LAND AND CIVIL WORKS : Fencing of substation land with barbed wire supported by RCC fencing pole (1.8 mtr long 125 X125 mm bottom and 75X 75 mm top) Yard fencing with chain link mesh over brick wall as per drawing no. DISCOM/EZ/D88 MS main and wicket gate on RCC column as per drawing no. DISCOM/EZ/D90 MS sheet shine board, bay indication board (250x150mm) & RYB phase indication board (150x150 mm MS sheet) Control room & internal electrification work for control room as per drawing no. DISCOM/EZ/D87 Yard leveling and metalling with metal of 40 mm size Approch Road With one hume pipe inner dia 900 mm 2.5mtr long for culvert Toilet including septic tank 60 Mtr. deep 150 mm Dia Tube well Providing and fixing HDPE double layer overhead tank 1000 Letre with input output valves & GI pipe fitting for water supply including providing water tap near transformer neutral earthing Supply and installation of 2 HP submersible pump Fire Fighting Equipment EQUIPMENTS : 33/11 KV Transformers (5 MVA) 11 KV VCB for transformer protection

Unit 3

Round Qty of LOT-1

Round Qty of LOT-2

Round Qty of LOT-4

Round Qty of LOT-6

Round Qty of LOT-7

Round Qty of LOT-8

RM

0
RM No

0 0 0 0 0 0 0 0 0

230 350 2 2 2 2 40 2 2

0 0 0 0 0 0 0 0 0

115 175 1 1 1 1 20 1 1

115 175 1 1 1 1 20 1 1

2 3

0 0 0

No

5 6 7 8 9

No

0
No RM No No

0 0 0 0

10

No

0
No No No No

0 0 0 0 0 0

2 2 2 0 2 2

0 0 0 0 1 2

1 1 1 0 2 6

1 1 1 0 1 7

11 12 B 13 14

0 0 0 1 1

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 C

11KV,2core CTs,300-150/5 Amps Control panel and Relays for 11KV transformer protection VCB 33 KV VCB for. Feeder protection 33KV CTs,300-150/5Amps Control panel and Relays for 33KV feeder protection VCB 33 KV VCB for transformer protection Control panel and Relays for 33KV transformer protection VCB 33KV CTs,200-100/5Amps 11 KV VCB for feeder protection 11KV,2core CTs,200-100/5 Amps Control panel and Relays for 11KV dual feeder protection Lead acid battery set 30V-100AH 30 volt 100 Amps Battery charger 33 KV Isolator 800 A. 11 KV Isolator 600 A. 33 KV Polymer L.A.Station Type 11 KVPolymer L.A. Station Type 33 KV Oil Immersed 3 Phase 4 wire CTPT Units 11 KV Oil Immersed 3 Phase 4 wire CTPT Units 110 V, 5 A Static energy meter with GPRS Modem DC Distribution board with MCB AC Distribution board with MCB Sodium Vapour Lamp(250 Watts) Control cables copper 2.5 Sq mm 12 Core Control cables copper 2.5 Sq mm 8 Core Control cables copper 2.5 Sq mm 4 Core Control cables copper 2.5 Sq mm 2 Core Tee clamps for ACSR Panther Bi-metallic clamps for ACSR Panther STRUCTURES AND BUS-BAR ARRANGEMENTS :

No Set No No Set No Set No No No No Set No. set. set No. No. No. No. No. No. No. No. Mtr. Mtr. Mtr. Mtr. No. No.

6 1 1 0 1 10 3 12 5 15 4 1 1 2 14 3 12 1 4 5 0 1 5 0 1350 800 900 36 36 0

6 2 0 0 0 11 1 3 4 0 1 0 0 0 6 0 6 0 4 4 0 0 0 0 900 225 675 0 0 0

18 6 4 6 2 18 11 33 12 18 5 2 2 8 36 30 36 12 14 26 2 2 12 800 4500 3175 3525 96 96 0

15 5 1 0 1 36 5 18 16 15 7 1 1 3 27 3 33 0 13 13 0 1 5 200 2825 1000 2075 36 36 0

15 5 3 3 2 4 2 9 10 27 5 2 2 7 24 6 24 3 9 12 1 2 11 600 1825 1025 1150 84 84 0

21 7 5 3 4 5 3 18 15 39 8 4 4 10 35 9 15 5 8 13 1 4 21 400 3400 2325 1975 156 156 0

44

33 KV Bus bar structure of H-Beam 152x152 mm 37.1 kg/m, 8 mtr long structure for substation 11 KV Bus bar structure of H-Beam 152x152 mm 37.1 kg/m, 8 mtr long structure for substation 9.1 mtr long new design gantry structure for 11 KV outgoing feeder for LA, ME and Isolator ,175x85mm double welded RS Joist 9.1 mtr long new design gantry structure for 33/11 KV transformer ,175x85mm double welded RS Joist GS DC cross arm 100X50x6 mm, 5.2 Mtr. Long for a/ H-beam top cross arm with tension patti 4Nos b/ H beam middle cross arm for ME 4 Nos c/ H-beam lower cross arm for isolator 4 Nos.d/- for H_Beam Structure Pole For 33 KV Incoming on H-Beam152x152 mm 37.1 Kg/ meter 9 Mtr Long 2 nos H-Beam152x152 mm 37.1 Kg/ meter,4.5 meter long for 33 KV Isolator GS channel cross arm100X50X6, 2.7 mtr long for 33 KV Isolator structure complet (1200 mm center to center) 4 feet bracing for isolator structure using 65x65x6mm angle( 45.020 Kg) 2 nos H-Beam152x152 mm 37.1 Kg/ meter,4.5 meter long for 11 KV Isolator GS channel cross arm100X50X6, 2.7 mtr long for 11 KV Isolator structure complet (1200 mm center to center) 4 feet bracing for isolator structure using 65x65x6mm angle( 45.020 Kg) GS DC Cross Arm 3.8 Mtr Long .(100X 50X6 mm) for 33 KV Bus bar support with tension plate GS DC Cross Arm 2.7 Mtr. Long.(100X 50X6 mm) for 11 KV Bus bar support with tension plate ACSR Conductor 200 sq.mm.(Panther) 33 KV compositee Polymer pin insulators for Panther conductor

No.

2
No.

0 4 0 0

28 20 12 16

3 9 0 0

9 13 6 8

10 12 6 8

45

0
No.

46

0
No

47

48

No.

0
No. set set

0 369 0 0 15 0 0 0 87 0
1 490

84 800 6 12 31 20 40 20 177 8
3 2892

0 414 0 0 16 0 0 0 52 0
4 106

42 284.55 3 6 14 10 20 10 37 4
1.6 574

42 501.3 3 6 5 10 20 10 110 4
3.2 964.4

49 50 51 52 53 54 55 56

123 0 0

set set set

6 3 0

set No.

0 21

57 58 59

No.

0
Km. No. 3 380

60 61 62 63 64 65 66 D 67 68 69 70 71 72 73 74 75 E 76

11 KV compositee Polymer pin insulators Strain hardware for 33 KV side For Panther suitable for Polymer disc Insulator Strain hardware for 11 KV side Polymer disc insulator Suitable for Panther Polymer Disc Iinsulator for 33 KV Polymer Disc Iinsulator for 11 KV 33 KV Top clamp 75x75x6mm angle 3.575Kg 11KV Top clamp 65x65x6mm angle 3.00Kg OTHER MISCELLANEOUS ITEMS : Concreting of structures & foundation (1:3:6) Double welded 175x85mm R.S.Joist 19.6 Kg/mtr 9. Mtrs. Long for yard lighting 70 sq.mm Single core XLPE cable 2.5 sq.mm. PVC Cable 16 sq.mm. PVC Cable Earthing of Sub station as per drawing no. DISCOM/EZ/91&92 Earthing of transformer neutral as per drawing no. DISCOM/EZ/D93 Cable trench for laying control cable as per drawing no. ADB/HVDS/EZ/64 Galvanized Nut & Bolts with washer ADDITIONAL EQUIPMENT : 11 KV 600 KVAR capacitor bank including protection panel & Breaker Total

No. No. No. No. No No No Cmt. No. Mtr. Mtr. Mtr. Job Job RM Kg No.

361 78 165 78 213 120 23 0 330 0 1360 0 0 1 1 100 2421 0 2 0 0 0 1 6 0 0 0 0 0

2950 36 453 36 518 160 953 0 1113 0 13200 0 600 0 0 0 7468 0 3 0 0 0 1 6 0 0 0 0 0

3920 288 744 288 828 910 978 0 2916 12 29120 400 200 2 2 200 20759 0 3 0 0 0 1 6 0 0 0 0 0

2042 63

1239.4 96

5811.6 168 648 168 684 295 1811 0 1947.85 6 8840 200 100 4 4 400 13181.3 0 2 0 0 0 0 0 0 0 0 0 0

342 309 69 102 668 355 13 175 465 310.2 0 0 714 670.942 0 17220 0 0 1 2 6 3520 200 100 2 3

100 200 6385 4839.28 0 0 0 0 0 0 4 24 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0

Schedule-2
B 77 78 79 80 EQUIPMENTS : 33/11 KV,8.0MVA Transformers 11KV,2core CTs,400-200/5 Amps Tee clamps for AAAC Panther Bi-metallic clamps for AAAC panther No No No. No.

Schedule-3
C 81 STRUCTURES AND BUS-BAR ARRANGEMENTS : AAAC Conductor 200 sq.mm.(Panther) Km.

Total

0 0 0 0 0 0 16 174 0 12 30 45 42 0 0 11 100 1 3 0

0 0 0 0 48 0 28 453 0 12 168 60 54 0 0 11 100 1 13 0

0 0 0 0 3 1

0 0 0 0 3 1

0 0 0 0 12 0 18 407.21 0 0 24 45 18 0 0 0 0 0 8 0

Schedule-4
(A) Equipments 82 83

84 85 86 87 88 89 90

91 92 93 94 95

(B) Structure and Bus-bar Arrangement Isolator supporting D.C. cross arm of 100x50x6 mm Galvanized channel 4.8 Meter long 11 KV, 2 addl. bus bar structure of H-Beam 152x152 mm 37.1 kg/m,8 mtr long, 4.8 M. long D.C. cross arm Galvanized (100x50 X 6 mm) for 11 KV, 2 addl. bus bar structure of HBeam 152x152 mm 37.1 kg/m Dog conductor Bimetallic clamp for transformer Bimetallic clamp for VCBs. Strain hardware set suitable for Dog conductor, 33 KV Polymer disc insulators Strain hardware suitable for Dog conductor,11 KV Polymer disc insulators T-clamp for jumper connection with A.B.switches & DO fuses (C) Other miscellaneous Items Concreting of X'mer foundation (1:3:6) Concreting of foundation of VCB (1:3:6) Cable trench for additional Three VCBs and X'mer as per drawing no. ADB/HVDS/EZ/64 Earthing for additional X'mer and VCB as per drawing no. DISCOM/EZ/D93 Painting of structure & bay indication Board Grand Total

0 0 0
Set Set Set Km. No. No. Set Set No. Cmt. Cmt. RM Job Job

6 0 8 93 0 24 48 0 60 0 0 22 200 2 4 0

40 18 264 183.921 7 7 66 18 12 60 168 0 15 53 500 5 9 0 36 45 42 0 15 10.5 100 1 4 0

Schedule-5
96 97 98 99 100 101

0
No.

0
0 3 30 2 24 0

0
0 3 42 2 24 0

0
0 12 90 8 96 0

0
0 0 12 0 0 0

0
0 0 18 0 0 0

33/11 KV,10.0MVA Transformers 11 KV CT 600/300/5 Amps Terminal clamps 11 KV, addl. bus bar structure of 19.6 kg/mtr 8 mtr long 175x85 mm double welded RS Joist Strain hardware suitable for panther conductor: Cable trench for additional Three VCBs and X'mer

No. No. Set Set Job

0 3 24 4 24 0

102 103

Control cable for transformer & VCB G.S. Nut-bolts Total

L.S.

0 0 0 0 0

0 0 0 0 0 0 0 0 0 0 1 0 0 639 5 5 25030 0 0

0 0 0 0 0 0 0 0 0 0 1 0 0 944 28 28 54936 0 0

0 0 0 0 0 0 0 0 0 0 4 0 0 14 1 1

0 0 0 0 0 0 0 0 0 0 0 0 0 172 5 5

0 0 0 0 0 0 0 0 0 0 0 0 0 810.8 4 4 33919.3 0 0

Schedule-7
104 105

EQUIPMENTS : 11 KV VCB for feeder protection with CTs. and panels G.S. Nut-bolts

Nos. L.S.

TOTAL

2 1 0 0 0 1 0 0

Schedule-8
Equipments
106

G.S. Nut-bolts

L.S.

Schedule-9
Equipment
107 108 109 110 111 112 H Beam 152X152 mm 37.1 Kg/meter 13 mtr. long pole 33 KV galvanised DC Cross arm ( 100X50 mmX6 mm 5 ft centre , 65.090 kg) Horrizontal and cross bracing 5' center with 4 back clamps 2300 mm long Earthing Set (Coil earth ) as per drawing no. DISCOM/EZ/D57 Mid span Joints suitable for Panther Conductor Repairing Sleeve forACSR Panther Conductor Galvanized Stay set 25 mm. complete with Galvanized back clamp(65X8 mm flat, 3.748 kg per pair) , stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set and turn buckle) Red oxide paint for line suports Aluminium paint for line suports Anti climbing devices Danger Boards as per drawing no.DISCOM/EZ/ D38 or D39 Binding wire / tape Carpet guarding { with galvanised channel 75mm, 2240 mm long }and G.I. Wire -- 3x6SWG + 1x8 SWG for lacings)} Nos. Set No. Set Nos. Nos.

130 4 6 8730 0 0

26344 16027.1 0 0 0 0

113 114 115 116 117 118

Sets Ltrs. Ltrs. Nos. Nos. Kgs.

0 229 229 298 250 159 0

0 1076 1076 1284 1153 322 0

0 1859 1859 2433 2204 993 0

0 508 508 640 554 445 0

0 501.25 501.25 550.2 501.2 308.56 0

0 1754.6 1754.6 2103 1945 730 0

119

Span

Total

Schedule-10
Equipments
120 33 KV Galvanized 'V' cross-arms with back clamps 75x75x6 mm angle as per drawing no. DISCOM/EZ/D76 Jointing Sleeves suitable for AAAC conductor, Dog, 100 Sq.mm. Galvanized Stay set 20 mm. complete with back clamps, stay wire 7/4.0 mm. (8.5 kg.stay wire per stay set ) and turn buckles Numbering of poles Total No.

0
0 120
No. Set No.

0
0 160 557 110 160 0

0
0 886 1732 697 886 0

0
0 10 800 32 10 0

0
0 160 549.1 130 160 0

0
0 283 1306 207.1 283 0

121 122

295 96 120 0

123

Schedule-11
Equipments

0
0

0
0

0
0

0
0

0
0

0
0

Schedule-12
Equipments

0
0

0
0

0
0

0
0

0
0

0
0

Schedule-13
Equipments

0
0

0
0

0
0

0
0

0
0

0
0

Schedule-14
Equipments
124 125 126 33 KV D.P. structure of H-Beam 152x152 mm 37.1 kg/m, 9 mtr long for ME DC channel 2.7 mtr 100X50X6 mm for 33 KV D.P. structure of H-Beam 152x152 mm, ME 33 KV Isolator, 600 A with earth switch Set Set Nos.

0
0 1 2 2

0
0 0 0 0

0
0 8 16 16

0
0 0 0 0

0
0 0 0 0

0
0 2 4 4

Schedule-15
Equipments
127 128 129 130 131 Rail Pole 52 kg/m, 13 m long Galvanized D.C.cross- arm of 100 X 50 X 6 mm. channel 5' centre 24.60 Kg) Earthing Set as per drawing no. DISCOM/EZ/94 and 95 33kv Polymer Lightning Arrester (Gapless Type) 33kv Underground XLPE Cable (3*300 sq mm) No. Set No. No. Km

0
0 8 2 12 6 0

0
0 0 0 30 0 0

0
0 0 0 34 0 0

0
0 0 0 32 0 0

0
0 0 0 22 0 0

0
0 0 0 0 0 0

132 133

Cable Termination Kit GS Pipe (125 mm diameter)

Set Mts

8 400

0 0

0 0

0 0

0 0

0 0

Schedule-16
Equipments
134 Line supports H-Beams 152 X 152 mm., 37.1 Kg./mtr 11 Mtr. Long Nos.

0
0 156

0
0 609

0
0 1915

0
0 602

0
0 362.2

0
0 1548.2

Schedule-20
Equipments
135 136 137 138 139 140 141 142 Aerial Bunched Cable of Size 3X120 for 11 kV line Suspension clamp assembly for 11 KV AB Cable including pole clamps Galvanized Dead end clamp /Anchor clamp assembly including brackets, pole clamps Galvanized Universal hook, Bolts & nuts T-Connector KZ3 95 Cable Straight through joint kits suitable for 120 sqmm Pre-Insulated lugs-CPTAU for 120 sq.mm End cap for 120 sq.mm cable Kms Sets Nos. No's No's Sets No's No's

0
0 13 51 22 73 44 4 29 88

0
0 0 1 0 1 1 0 0 1

0
0 106 418 179 597 358 30 239 716

0
0 0 0 0 0 0 0 0 0

0
0 0 0 0 0 0 0 0 0

0
0 0 0 0 0 0 0 0 0

Schedule-21
Equipments
143 11 KV 'V' cross-arms with back clamps Galvanized angle type 65x65x6 mm 12.34 kg Galvanized Stay set 16 mm. complete with back clamps, stay wire 7/3.15 mm. (5.5 kg.stay wire per stay set ) and turn buckles as per drawing no. DISCOM/EZ/D67 No.

0
0 23

0
0 953

0
0 936

0
0 456

0
0 280.2

0
0 1790

144

Set

511

1518

3445

1497

948.74

2214.8

Schedule-24
Equipments
145 146 11 KV Polymer lightning arrestors gap less Type Cable trench for control kiosks No. RM

0
0 6 0

0
0 6 200

0
0 12 400

0
0 9 300

0
0 6 200

0
0 9 300

Schedule-25
Equipments
147 D.C.cross- arm of 100 X 50 X 6 mm.Galvanized channel 4' centre) 53.381Kg Set

0
0 5

0
0 15

0
0 17

0
0 16

0
0 11

0
0 0

Schedule-27
Equipments
148 149 11kv Underground XLPE Cable (3X185 sq mm) GI Pipe (80 mm diameter) Km Mts

0
0 0 400

0
0 0 0

0
0 0 0

0
0 0 0

0
0 0.2 0

0
0 0.2 0

Schedule-31
Equipments
150 151 AAAC 'Rabbit' Jointing Sleeves suitable for Rabbit Conductor.Al. Eq. AAAC km No.

0
0 0 0

0
0 2 0

0
0 7 23

0
0 0 0

0
0 0 0

0
0 0 0

Schedule-32
Equipments
152 AAAC 'Raccoon' km

0
0 0

0
0 0

0
0 91

0
0 0

0
0 0

0
0 0

Schedule-33
Equipments
153 154 155 156 157 Clamp for Cable Dead End kit Galvanized Stay set 16 mm. complete with back clamps, as per drawing no. DISCOM/EZ/D67 Stay Wire 7/3.15 mm. (5.5 kg.stay wire per stay set ) Turn buckles as per drawing no. DISCOM/EZ/D67 No. Set Set

0
0 0 0 0
Kg. No.

0
0 0 0 0 0 0

0
0 0 0 0 0 0

0
0 0 0 0 0 0

0
0 0 0 0 0 0

0
0 0 0 0 0 0

0 0

Schedule-36
Equipments
158 159 160 161 162 Transformer 11/0.433 KV 63 KVA D.C.cross-arm of 100 X50X6 mm. 8' centre Galvanized channel 2699 mm long Distribution Box mounting channel 100x50x6 mm,2699 mm long with back clamp 11 KV D.O. fuse unit(one set of 3 nos.) Transformer clamping set 50x50x6 mm Angle Transformer belting with 50 X 50 X 6 mm.Galvanized angle with two cross fixing channels 9 ft. No. Set No. Set Set

0
0 0 21 54 67 21 21

0
0 5 94 196 238 94 94

0
0 0 174 399 174 174 174

0
0 0 56 121 205 56 56

0
0 0 35 72 36 35 35

0
0 0 118 256 119 118 118

163

Set

164 165 166 167

Transformer mounting Channel 100 X 50X 6 mm 2699 mm Galvanized channel AAAC Conductor Rabbit for Jumpering Earthing arrangement as per drawing No.Discom/EZ/D73 11 KV Polymer Lightning arrestors L.T. Distribution box with 150 A isolator,150 Amps three phase MCCB on incomming and with 6 no. single phase MCCB100 A on outgoing side 50 Sq.mm.,single core `XLPE insulated unarmoured aluminium conductor cable LT CT operated three phase 4 W Static energy meter with CT & GPRS Modem

Set Mtr. Set No.

21 630 76 63

112 2820 313 324

184 5220 337 522

64 1680 150 168

39 1050 40 105

130 3450 137 345

168 169 170

No. Mtr. No.

7 0 21

30 400 94

19 0 174

24 0 56

1 0 35

1 240 118

Schedule-37
Equipments
171 Transformer 11/0.433 KV 100 KVA L.T. Distribution box with 250 A isolator,200 Amps three phase MCCB on incomming and with 6 no. single phase MCCB 100 A on outgoing side No.

0
0 11

0
0 77

0
0 118

0
0 39

0
0 29

0
0 94

172 173 174

No. 41 199 150 Sq.mm.single core XLPE insulated un-armoured Mtr. aluminium conductor cable 5360 13800 11 KV A.B. switch Set 38 110

197 42600 186

120 19240 86

30 2960 38

95 7880 126

Schedule-38
Equipments
175 Transformer 11/0.433 KV,200 KVA L.T. Distribution box with 400 A isolator, 400 Amps three phase MCCB on incomming and with 9 no. single phase MCCB 100 A on outgoing side 300 Sq.mm.Single core XLPE insulated unarmoured aluminium conductor cable No.

0
0 19

0
0 23

0
0 69

0
0 31

0
0 10

0
0 39

176 177

No. Mtr.

58 5560

99 10440

236 12260

102 5020

11 1400

40 2560

Schedule-39
Equipments
178 179 180 Transformer 11/0.4 KV (Conventional) 25 KVA 140 Kg., 8.0 M. long PCC poles TPN switche fuse unit (63 Amps.) No. No. No.

0
0 0 0 0

0
0 5 40 5

0
0 0 0 0

0
0 0 0 0

0
0 0 0 0

0
0 0 0 0

181

TPN switche fuse unit (32 Amps.)

No.

Schedule-46
Equipments
182 11 KV D.O. fuse and lightening arrestors mounting structure channel with back clamps (100 X 50 X 6 mm 2717 mm long.) No.

0
0 0

0
8 2

0
0 5

0
0 4

0
0 2

0
0 9

Schedule-48
Equipments
183 184 185 186 16 KVA 11/0.4 KV (Conventional) transformer. DC Cross Arm for single pole cut point Galvanized Channel (100x50x6mm) D.O. mounting Galvanized Channel 75x40x6 mm Protection cum metering box with 40 Amps MCCB & 4 No. three phase meter for 25 KVA transformer As Per DRG.ADB/HVDS/EZ/10 Protection cum metering box with 25 Amps MCCB & 3 No. three phase meter for 16 KVA transformer 25 Sq mm. XLPE insulated Single core Al.cable 6 sqmm PVC insulated 4 core armoured Al.cable G.I. Pipe 40 mm (9 mtr per s/s) G.I. Wire 8 swg Earthing set for transformer as per Drawing No.HVDS/EZ/03 Galvanized eye- bolt - 16 mm HT Tape for covering LT Bushing including winding and blower heating No No No No

0
0 0 0 0 0
No

0
8 16 30 0 0 280 0 0 0 14 0 420 0

0
0 0 0 0 0 0 0 0 0 0 0 0 0

0
0 0 0 0 0 0 0 0 0 0 0 0 0

0
0 0 0 0 0 0 0 0 0 0 0 0 0

0
0 0 0 0 0 0 0 0 0 0 0 0 0

187 188 189 190 191 192 193 194

0
mtr mtr mtr kg Set no mtr

0 0 0 0 0 0 0

Schedule-49
Equipments
195 AAAC Conductor Raccoon for Jhumper Mtr.

0
0 0

0
0 0

0
0 0

0
0 0

0
0 0

0
0 90

Schedule-51
Equipments
196 A.B Cable hanging clamps/ tension clamps (Galvanized) as per enclosed Drawing No.

0
0 842

0
0 2457

0
0 5291

0
0 2759

0
0 1877

0
0 3322

197 198 199 200 201 202

203

Suspension clamp for AB Cable drg DISCOM/EZ/70 Dead End clamp for AB Cable as per drg DISCOM/EZ/35 Clamp for neutral Piercing connector type-1 , single phase as per drg DISCOM/EZ/33 Piercing connector type-2 drg DISCOM/EZ/33 1100 Volts Grade Aerial bunched XLPE Cable including 3 % sag:- 3 X 50 + 1 X 16 + 1 X 35 sq.mm. AS per TS Dist. Box for housing 5 No. 10Amps MCCB including accessories for fixing with pole suitable for AB XLPE Cable

No. No. No. No. No. Km.

842 252 842 2524 337 1

2457 737 2457 7372 983 0 0

5291 1587 5291 15873 2116 0 0

2759 828 2759 8276 1103 0 0

1877 563.1 1877 5631 750.8 0 0

3322 996.6 3322 9966 1328.8 0 0

No.

Schedule-52
Equipments
204 Polycarbonate L.T Dist. Box spring loaded constant pressure multi connection type for three phase supply type for fixing with pole suitable for AB XLPE Cable-Three Phase 1 in 3 out Polycarbonate L.T Dist. Box spring loaded constant pressure multi connection type for single phase supply type for fixing with pole suitable for AB XLPE Cable-Three Phase 1 in 9 out No.

0
0

0
0

0
0

0
0

0
0

0
0

20

205

No.

20

Schedule-53
Equipments
206 PVC Insulated, 1100 V grade armoured AL Cable 10 sq mm (four core) Static Energy meters : Three phase meter with data downloading facility 40 Amps max With Poly caronate/transparent engineering plastic Meter Box Suitable Wooden Board size 400x400 mm with GS earthing nut and bolt with 2 washer and 4 anchor bolt 6 mm Wall bracket of GS angle 30x30x5 mm, complete with 2 anchor bolts 12 mm and 1 GS nut and bolt with 2 washer mtr

0
0 38700

0
0 70040

0
0 246580

0
0 48480

0
0 40420

0
0 104460

207

Each

1422
No.

771 3502 23873

3452 12329 52275

400 2424 25704

619 2021 15450

2711 5223 31632

208

1935
No.

209

8490

210 211 212

Internal wiring for three phase supply with PVC cable, unarmoured, stranded copper conductor, single core 4 sq mm, length limited to 10 mtr per connection GI wire 6 SWG Earthing Connector

No. Kg No.

1935 25470 8490

3502 71619 23873

12329 156825 52275

2424 77112 25704

2021 46350 15450

5223 94896 31632

Schedule-54
Equipments
213 214 PVC Insulated, 1100 V grade armoured AL Cable 4 sq mm (twin core) Static Energy meters : Single phase meter with data downloading facility 40 Amps max With Poly carbonate Meter Box Suitable Wooden Board size 250x350 mm with GS earthing nut and bolt with 2 washer and 4 anchor bolt 6 mm Internal wiring for single phase supply with PVC cable, unarmoured, stranded copper conductor, single core 2.5 sq mm, length limited to 10 mtr per connection mtr Each

0
0 100760 2448
No.

0
0 309480 3927 20371

0
0 585860 8877 39946

0
0 340080 6073 23280

0
0 175600 2212 13429

0
0 399480 7065 26409

215

6555
No.

216

6065

19585

38170

22065

12986

24996

Schedule-55
Equipments
217 Poly carbonate/Transparent engineering plastic Meter Box No.

0
0 4620

0
0 19175

0
0 39946

0
0 19231

0
0 12619

0
0 21856

Schedule-56
Equipments
218 PVC insulated, 1100 Volts Grade Armoured Al.Cable 6.0 Sq.mm. (Two Core) mtr

0
0 37925

0
0 122425

0
0 266325

0
0 156900

0
0 116225

0
0 160875

Schedule-57
Equipments

0
0

0
0

0
0

0
0

0
0

0
0

Schedule-58
Equipments
219 L.T. Distribution box 35 amp MCCB without PF unit Nos suitable for 25 KVA transformer L.T. Distribution box with 630 A isolator,630A three Nos phase MCCB on incomming and with 12 no. single phase MCCB 150 A on outgoing side suitable for 315 KVA transformer

0
0 0

0
0 8

0
0 47

0
0 8

0
0 1

0
0 1

220

12

12

15

221 222 223 224 225 226 227

33 KV AB Switch Polymer 11 KV LA units LT Poles Replacement (Tilted and Damaged) with 175X85 mm.19.6 kg/mtr. ,9.3 Mtr. long RSJ supports Earthing Set (DTR Chemical earthing) as per "TS 55" 11 Meter long, 152x152mm H-Beam 13 Meter long, 152x152mm H-Beam Cable Termination Kit for 11 KV AB cable

Nos Nos Nos

0 48 330

0 45 786 55 15 49 0

0 305 1850 150 0 0 188

2 175 550 80 150 0 0

1 1 1 1 1 1 1

1 10 1 1 1 1 1

set Nos Nos Nos

20 30 0 24

Schedule-59
Equipments

0
0

0
0

0
0

0
0

0
0

0
0

Schedule-60
Equipments
228 1100 Volts Grade Aerial bunched XLPE Cable including 3 % sag, 3 X 95 + 1 X 16 + 1 X 35 sq.mm. Dist. Box for housing 5 No. 10Amps MCCB including accessories for fixing with pole suitable for AB XLPE Cable-Three Phase 1 in 3 out Dist. Box for housing 5 No. 10Amps MCCB including accessories for fixing with pole suitable for AB XLPE Cable-Single Phase 1 in 9 out Km.

0
0 42
No.

0
0 127

0
0 272

0
0

0
0

0
0 171.083

142 96.6655

229

822
No.

2457

5291

2759

1877

3322

230

822

2457

5291

2759

1877

3322

Schedule-61
Equipments
231 232 Kit Kat16 Amp Internal wiring for single phase supply with PVC cable, unarmoured, stranded copper conductor, single core 2.5 sq mm, length limited to 15 mtr per connection No. No.

0
0 490

0
0 786

0
0 1776

0
0 1215

0
0 443

0
0 1413

490

786

1776

1215

443

1413

Schedule-62
Equipments
233 L.T. Distribution box with 300 A isolator,300A three phase MCCB on incomming and with 6 no. single phase MCCB 60 A on outgoing side No.

0
0 0

0
0 0

0
0 0

0
0 0

0
0 0

0
0 3

233

L.T. Distribution box with 300 A isolator,300A three phase MCCB on incomming and with 6 no. single phase MCCB 60 A on outgoing side Dist. Box for housing 5 No. 10Amps MCCB including accessories for fixing with pole suitable for AB XLPE Cable-Three Phase 1 in 3 out Dist. Box for housing 5 No. 10Amps MCCB including accessories for fixing with pole suitable for AB XLPE Cable-Single Phase 1 in 9 out

No.

0
No.

229

822
No.

2457

5291

2759

1877

3322

230

822 0

2457 8

5291 47

2759 8

1877 1

3322 1

219

220

L.T. Distribution box 35 amp MCCB without PF unit Nos suitable for 25 KVA transformer L.T. Distribution box with 630 A isolator,630A three Nos phase MCCB on incomming and with 12 no. single phase MCCB 150 A on outgoing side suitable for 315 KVA transformer Protection cum metering box with 25 Amps MCCB & 3 No. three phase meter for 16 KVA transformer TPN switche fuse unit (63 Amps.) TPN switche fuse unit (32 Amps.) L.T. Distribution box with 400 A isolator, 400 Amps three phase MCCB on incomming and with 9 no. single phase MCCB 100 A on outgoing side L.T. Distribution box with 250 A isolator,200 Amps three phase MCCB on incomming and with 6 no. single phase MCCB 100 A on outgoing side L.T. Distribution box with 150 A isolator,150 Amps three phase MCCB on incomming and with 6 no. single phase MCCB100 A on outgoing side DC Distribution board with MCB AC Distribution board with MCB Lead acid battery set 30V-100AH 30 volt 100 Amps Battery charger No No. No.

3 0 0 0

12 280 5 5

12 0 0 0

15 0 0 0

1 0 0 0

1 0 0 0

187 180 181

176

No.

58

99

236

102

11

40

172

No.

41

199

197

120

30

95

168 35 36 26 27

No. No. No. Set No.

7 0 1 1 1

30 0 0 0 0

19 2 2 2 2

24 0 1 1 1

1 1 2 2 2

1 1 4 4 4

You might also like