0% found this document useful (0 votes)
53 views4 pages

EE40042

previous year paper
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
53 views4 pages

EE40042

previous year paper
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
No. of Printed Pages : 4 EE40042 MAY 2023 (Semester) ILLUMINATION PRACTICES ‘Prefiea aera : 3 2] (arftreat 3m : 60 Time allowed : 3 Hours} [Maximum Marks : 60 He: i) Raa Ah terre, Ha EL Note: There are THREE sections in the paper A, B and C. (il) Berar eH eT FM LH AH 10: ET TR AEC | Te TT Uae He TB OE at 10 sr aegis TR & wea eB | Answer all the 10 parts of the question No. 1 in Section A, Each part carries ‘one mark and all 10 paris have objective type questions. (iti) AaRIT AH 8 wed FF Pore 6 eat a ere aire | wet WETS ate TB Cae EHTS RT / 50 Wee FR GHA | Answer any 6 questions out of the 8 questions in Section B. Each question carries 3 marks and to be answered within 5 lines / 50 words. (iv) Bert aH 6 ead a) Peel 4 ead sere Cire | cae eT 8 ates BT Be FARTS ORT / 150 Woah a I GATE | Answer any 4 questions out of the 6 questions in Section C. Each question carries 8 marks and 10 be answered within 15 lines / 150 words. (vy) rede deers & aett eal at aE Cw ATT BT BIRT | Solve all the questions of a section consecutively together. (oi) Bat srarant# area BY Bt PR Hai Tze ah ATH 8 | Only English version is valid in case of difference in both the languages. ar - Section ~ A 1 @ fda fea are woe es Pica werd 7 (a) @a-aeg A aea—arot ®% aaa (@) fawaads ver (@) satan a aang at On which of the following factor the maintenance factor does not depend ? (a) Lamp cleaning schedule (b) Ageing of lamp (©) Type of work carried out (a) None of the above ze (ora) © sexned wth Ot Scanner EE40042 Gi) Gil) dv) ) wi) (ii) (2 of4) 7333 rat re Pak ara & (@) SRS sew () @ea-Sard aya (©) wa dant (oar er @ were Utilization factor depends on (@) Size of the room (b) Space-height ratio (©) Colour of walls/ceiling (@)_ All of the above ‘anten wre (2) FHRIRRE (>) Satferta cia (©) Safer cera @ ve Candela is unit of (a) Light flux (b) Luminous intensity (c) Luminous efficiency (@) Glare ‘arene Braiex ar Feraia fave we srerfta 8 7 @ apna fer 0) afar (©) arn fa @ eadaien faa The principle of the Simple photometer is based upon. (a) Inverse Square Law (&) Square Law (c) Inverse Law (d) Lambert cosine law fea oord i sera wien en Sra 8 7 @ wAse (b) aeRA Fe (©) waestt @ Bearer In which work maximum illumination level is required ? (a) Bedroom (b) Study room: (©) Railway platform @ Street light ‘Seitor vin faoeht Dart & fer seth aha 2 @ eater ) 1 (© wa args @ sarah Halogen lamps are useful for the illumination of (a) Sports ground (b) Park (c) Airport @_Allofthe above aise arog Sey Hwee ar aT SATS @® ae Tart (© fen @ Ae The colour of light in Sodium vapour lamp is (a) Red (b) Pink (©) Yellow (@)_Bluish-green © sexned wth Ot Scanner EE40042 @of4) 7333 (viii) BF BT aca Baa aoa fT a seTaT 7 (a) UR aCe (0) fatrare © Awww @ tae Which bulb is operated on the lowest power ? (@) Night Bulb (6) Neon Bulb © GLSBulb @ Torch Bulb (ix) Serre or tr asic ae & (@) meft ) Tenet © Fi@mw @ ser sae Colour of light depends on (@) Frequency (b) Wavelength (©) Both (a) and (b) (@)_ Speed of light (St atert aren dist (a) 10-20 lumens/m? (6) 30-40 lumens/m? (©) 40-75 lumens/m? (a) 100-140 lumens/m The illumination level in houses is in the range of (a) 10-20 tumens/m? (b) 30-40 lumens/m? (©) 40-75 lumens/m? (@) 100-140 tumens/m? (x10) er - at Section - B 2. sRaPraT ane wt oferta Fy | Define the utilization factor. @) 3, Ratara are at ofefita wt | Define the maintenance factor. @) 4, séta ait adhe aa reg a oferta at | Define the term incandescent and incandescent lamp. @) 5. fatwa cst ht eine aan aang | List the different types of lamps with their applications. @ 6. sre sites vere omen & feet dia ens ar secre aAifire | State any three benefits of good industrial lighting arrangement. @) 7, BEAT TR TIT HY FT SATA 7 ‘What are the requirement of general lighting arrangement ? @) 8, Barerdh srarar extern & fore fe were & etal ar suet Pasar sre @ 7 Which types of lamps are used for decorative lighting arrangement ? @) 9. tadt arefén a fore aera aravaaand aa & 7 ‘What are the general requirements for factory lighting ? @) P.O. © sexned wth Ot Scanner EE40042 (of 4) 7333 10. i. 14, 15. tan —at Section -C @ waa (@) MSCP, (b) GA Vie are HF seifenka cae, (¢) MSCP Nf aTe 250 ate ‘eh ot Sit Pe 0.4 CHR Ht aie Aaa B tN FTF 1500 TAA HT Her AAT | Determine (a) MSCP, (b) Luminous intensity in lumens per watt, (c) MSCP per watt of 250 volts lamp which takes a current of 0.4 ampere and has a total flux of 1500 lumens. ai) Sera ora & fore vige 8 ike Fahy MEME | Explain point to point method for lighting calculation. (444) @ . rh ard Ae ht arhvoret a aoe tants & are aT | Explain with neat sketch the working of carbon are lamp, Gi) LED aa wig att agua ere State advantages and applications of LED lamp. (444) @ we hah ae a witte acne A aeherel a are | Explain with neat diagram, working of fluorescent tubelight. (i) CFL Aa ara ak aga aang | State advantages and applications of CFL Lamp. (444) @ fairer war weer atomrail caren Sif | Describe different types of lighting schemes. (i) alates eI aTftiisrs vere craen & fare wd fears 1 fran aa aa are war Si HASTE | State and explain factor while considering design illumination for interior location of commercial lighting. (44) (She crater st arg | Explain street lighting Gi) Gers eer eaTe 7 ers CHRfeT HI Seva TATRT | ‘What is flood lighting ? State the purpose of flood lighting. (444) ‘Praferftaa on eifrea fecroft ferfiae + ‘Write short note on following : @ He hew ars Selection criteria for lamps (i) Wet vere Seren & fare aera sagan General requirements for outdoor lighting (444) © sexned wth Ot Scanner

You might also like