The Farmhouse
The Farmhouse
The Farmhouse
Wall construction is built in machine laft. The roof is covered with metal sheets.
The floor partition is a wooden beam layer. Windows with one layer of glass. Because of the buildings
condition, the seller has carried out a condition assessment of the property himself. Then
the assessment has not been carried out by a professional building expert, the buyer is encouraged to
examine the property extra thoroughly and preferably in consultation with a professional. Seller
Internal:
1st floor
Entrance: Insulated wooden floor and painted wooden paneling on the walls. Painted panel in ceiling.
Living room: Insulated wooden floor. Painted wooden paneling on walls and ceiling, used linseed oil paint.
Kitchen: New floor joists, unfinished insulation and floorboards. Painted wood panel on
Boost
Improvements
New joists, insulation and floorboards entrance hall and living room 2017
Drained around the foundation on two walls and membrane applied in 2014
Painted three of four exterior walls with linseed oil paint 2021
Contents
The 1st floor has an entrance hall with one window and door, and the possibility to place another staircase
the attic floor. From the entrance there is access to the living room and kitchen. The living room has two windows and
possibility of fireplace. The kitchen has two windows, good furnishing options and
possibility of fireplace. Chamber/planned bathroom has one window. Possibility of crawl space
under parts of the kitchen and bedroom/planned bathroom.
The attic floor has one window and a door to the former external staircase. The attic floor is
unfurnished.
There is also a partly fallen-down outbuilding on the property, as well as the ruins of an earlier one
Standard, farmhouse
The seller has assessed the property. Below is information on conditions that have been assessed
Drainage Roof drains are terminated above ground and are partly missing.
There is little fall on the ground, and the foundation gets some moisture. The drainage has reached an advanced age on
two sides
(over 30 years). Somewhat elevated moisture values in the basement. It is recommended to replace the drainage on two
sides of the home in time
Gutters and downspouts Gutters and downspouts must be replaced in their entirety.
Equipment on the roof There is a lack of snow catchers and access for sweepers. This must
due
planned bathroom, and the floor partition must be insulated and floorboards installed.
Drainage pipe Drainage system has not been completed. Work must be expected
on this, as well as application for and installation of a mini sewage treatment plant.
Water pipes The facility has not been completed. Work must be expected
Windows Some frames on the outside are weather-worn and should be surface treated. Glass panes that are broken must
be replaced. It is noted that the insulating ability of these windows does not satisfy the current U-value requirements.
Outer door The door hits the threshold when opening/closing. It has needs
External walls Cracks and rot have been registered in the facade. It is recommended
to join work in certain places, and possibly change the bottom pile.
Attic A leak is detected in the pipe penetration, and it is recommended to seal the penetration sufficiently.
Roof construction Inspected from ground and ladder with no evidence of structural failure or inadequate ventilation.
Roofing The roofing has reached an age that makes the tightness uncertain in the future.
from the year of construction, possibly installing new kitchen furnishing elements. Some repair of rot in the wall must be
expected.
Wet room If the chamber is to be used for a bathroom/wet room, costs and any application must be calculated.
natural ventilation.
Energy
Energy rating: G
Economy
*Information about municipal taxes: The amount of municipal taxes will depend on the property's use, type of waste
solution and whether a water and sewage solution is established, as well as the municipality's
Public affairs
The name of the property: Farm number 43, utility number 8 in Nes (Ak.) municipality.
Public law orders: No public law orders have been registered on the property. Any public law orders or restrictions of
discretion that are adopted accordingly
the buyer's takeover of the property does not constitute a deficiency according to the Disposal Act.
Registered encumbrances and rights: The following encumbrances are registered on the property and
rights that follow the property's cadastral register upon transfer to a new title holder:
There is neither a temporary use permit nor a completion certificate for the property, and planning and
the Building Act's formal requirement for legal use of the property cannot therefore be documented. The buyer assumes
the risk for future continued use and any public law orders.
The property is not connected to a municipal water main, nor does it have a private well. The property does not have a
drainage/purification system. Attention is drawn to the fact that the municipality can carry out mapping work on private
facilities. This may involve future requirements for improvements to the property
sewage system. The buyer assumes risk and responsibility for the aforementioned conditions, including for further use.
The property does not have a registered right of way, but there may be a right of way from long ago. It is the new owner's
risk to formalize any right of way.
The property is located in an area regulated for scattered housing developments. The property is located in a LNFR
area (Agricultural, nature and outdoor areas as well as reindeer husbandry). This means that, as a general rule, the area
cannot be developed with a view to housing or other development, because, among other things,
account must be taken of e.g. public rights, nature conservation, agriculture or outdoor life. In LNFR area can
there may be building and subdivision bans, and it is also unlikely that a change of use will be approved
of existing buildings or approved construction of buildings contrary to the main rule. In the area section of the municipal
plan, information may appear about the impact of the LNFR category.
The regulation applies to future measures, i.e. existing houses and holiday homes can be used in line with
previously granted municipal permits, but the regulation may have consequences in case of possible reconstruction, for
example after a fire. Construction of new homes in the LNFR area cannot take place without approval
dispensation or as a result of the provisions in the zoning plan. Contact the municipality
Access to rental
It is not known that there are public law rules that prevent the entire property being rented out.
Legal mortgage
The municipality has a legal lien on the property for overdue claims for property tax and municipal taxes/fees.
Concession
No. The buyer must, upon entering into this contract, sign the form "Self-declaration of
Odel right
no
Obligation to live
no
Obligation to drive
no
Drainage Roof drains are terminated above ground and are partly missing.
There is little fall on the ground, and the foundation gets some moisture. The drainage has reached an advanced age on
two sides
(over 30 years). Somewhat elevated moisture values in the basement. It is recommended to replace the drainage on two
sides of the home in time
Gutters and downspouts Gutters and downspouts must be replaced in their entirety. NOK 15,000 – 20,000
Equipment on the roof There is a lack of snow catchers and access for sweepers. This must
due
planned bathroom, and the floor partition must be insulated and floorboards installed.
Drainage pipe Drainage system has not been completed. Work must be expected
Water pipes The facility has not been completed. Work must be expected
Windows Some frames on the outside are weather-worn and should be surface treated. Glass panes that are broken must
be replaced. It is noted that the insulating ability of these windows does not satisfy the current U-value requirements.
Outer door The door hits the threshold when opening/closing. It has needs
External walls Cracks and rot have been registered in the facade. It is recommended
Roof construction Inspected from ground and ladder with no evidence of structural failure or inadequate ventilation.
Roofing The roofing has reached an age that makes the tightness uncertain in the future.
from the year of construction, possibly installing new kitchen furnishing elements.
Wet room If the chamber is to be used for a bathroom/wet room, costs and any application must be calculated.
natural ventilation.
The farmhouse is built on two floors. The foundation wall is made of poured concrete. Wall construction is built in machine
laft. The roof
is covered with metal sheets. The floor partition is a wooden beam layer. Windows with one layer of glass.
1st floor
Entrance: Insulated wooden floor and painted wooden paneling on the walls. Painted panel in ceiling.
Living room: Insulated wooden floor. Painted wooden paneling on walls and ceiling, used linseed oil paint.
Kitchen: New floor joists, unfinished insulation and floorboards. Painted wood paneling on the walls and ceiling.
Chamber/planned bathroom: New joists, unfinished insulation and floorboards. Painted wood paneling on the walls and
ceiling.
Boost
Improvements
New joists, insulation and floorboards entrance hall and living room 2017
Drained around the foundation on two walls and membrane applied in 2014
Painted three of four exterior walls with linseed oil paint 2021
5. Main report
• Work was carried out on and around the foundation wall in 2016, after the original year of construction (1932)
• It is not foundation wall plastic, but a membrane has been applied on two of the sides
• Drainage on two of the sides is from 2014
• On other sides, the drainage has reached an age that can increase the risk of damage/consequential damage
• During an internal inspection, some moisture has been detected, which may result in reduced function or functional
failure
• The building is exposed to inflow of surface water (landslide towards the home)
• There is insufficient drainage of water from roof drains at the foundation wall
Summary of drainage: Roof drains are terminated above ground and are partly missing. There is little fall on the terrain,
and the foundation wall
gets some moisture stress. The drainage has reached an advanced age on two sides (over 30 years). Somewhat elevated
moisture values in the basement. The
it is recommended to change the drainage on both sides in time to come on the basis of proven deviations. Estimated
repair costs NOK
50,000 – 100,000.
5.3 Windows –
• Work has been completed on five of the seven windows after the year of construction. These were restored (linseed oil
putty and -
• One of the windows that has not been restored has broken glass panes
• The two windows that have not been restored have weather-worn frames
• There have been no detected deviations in external sealing such as fittings, water table and framing
Summary of windows: Some frames on the outside are weather-worn and should be surface treated. Glass panes that are
broken must
be changed. It is noted that the insulating ability of these windows does not satisfy the current U-value requirements.
• Painted outer door (linseed oil paint). Not sure if the door is original
• There are deviations in external sealing such as fittings, water table and framing.
Summary outer door: The door steps on the threshold when opening/closing. It needs adjustment, possibly replacement.
5.5 Outer walls –
• No work has been carried out after the original year of construction other than that three external walls have been
painted (linseed oil paint).
recent times
• Some cracks and holes have been detected, possible rot in some logs, some moisture at times
Summary of external walls: Cracks and rot have been registered in the facade. It is recommended to join work in certain
places, and
• There are no signs of moisture from leaks or condensation on surfaces in the roof structure, but some moisture
• There are signs of insufficient sealing around penetrations in the construction, but pipe penetrations should be sealed.
Summary attic: A leak is detected in the pipe penetration, and it is recommended to seal the penetration sufficiently.
• Metal gutter with visible damage on one side of the house, missing downspout
• Gutters and downspouts are completely missing on the other side of the house
• It is unknown whether there were gutters and downspouts on the house in the year of construction
Summary gutters and downspouts: Gutters and downspouts must be replaced in their entirety. Estimated repair costs NOK
15,000 –
20,000.
5.9 Roofing –
• Work has been carried out after the original year of construction; roof tiles replaced with current sheet metal, estimated
about. 1980
• The pipe has been taken down above the roof and work must be expected to cover/fit the pipe when rebuilding
this
• The roofing has reached an age that increases the risk of damage/consequential damage
Summarize roofing: The roofing has reached an age that makes the tightness uncertain in the future.
Summary of equipment on the roof: There is a lack of snow catchers and access for sweepers. This must be established for
good personal safety. Estimated repair costs NOK 25,000 – 50,000.
• Solid pine floors in the ground floor in the entrance hall and living room are new in 2017, and there has been no evidence
of sagging, warping or failure in
this. In the kitchen and chamber/planned bathroom, the joists are new in 2017, but insulation and floorboards remain
• Floor separation from the year of construction, lack of insulation and floorboards in the attic
Summary floor separation and floor on the ground: Floor on the ground must be completed in the kitchen and
chamber/planned bathroom, and the floor separation must be insulated and floorboards laid. Estimated repair costs NOK
50,000 – 100,000.
5.12 Fireplace/chimney –
• No deviations have been detected at the sweep hatch/soot hatch in relation to the distance to combustible material
Summary fireplace/chimney: If a fireplace is to be connected to the pipe, it must be rehabilitated.
5.13 Kitchen –
• Kitchen furnishings from the year of construction must be reassembled after completion of the floor, and possibly
supplemented with new ones
parts.
• There is some rot in the wall by the pipe due to previous moisture. This should be improved.
Kitchen summary: It must be expected to refit kitchen fittings from the year of construction, possibly installing new kitchen
fittings. Rot in the wall by the pipe should be repaired.
• Planned bathroom not completed, the room is a chamber from the year of construction
• If the room is to be used for a bathroom, costs must be calculated to meet the requirements in building regulations and
Summary wet room: If the chamber is to be used for a bathroom/wet room, costs and any application must be calculated.
5.15 Legality
• It has not been checked whether there is a lack of conformity between current use and approved construction drawings
• The home does not have obvious illegalities (for example, illegal changes of use)
• No conditions have been uncovered that indicate that the housing unit has not been divided into fire compartments in
accordance with the requirements of the technical regulations
• It has not been checked whether there is a missing completion certificate/temporary use permit
• There are no evidence of deviations in requirements for escape, daylight conditions or ceiling height
• There is no shortage of fire-extinguishing equipment and smoke alarms in the home in accordance with regulations
• There is no damage to fire extinguishing equipment and smoke alarms, and these are no older than 10 years
• Work was carried out at the facility in 2016, such as the start of a new kitchen and bathroom
Summary of drainage pipes: The drainage system has not been completed. Work must be expected on this, as well as the
installation of a mini sewage treatment plant. Estimated repair costs NOK 100,000 – 150,000.
• Work has been done at the facility in 2017, such as the start of a new kitchen and bathroom
Summary of water pipes: The facility has not been completed. Work on this must be anticipated, as well as costs for well
drilling
or connection to a municipal water main. Estimated repair costs NOK 150,000 – 200,000.
5.18 Electrical –
Summary electrical: Only one course has been put into use, and some costs must be expected if you want to put more into
use
courses.
5.19 Ventilation –
Summary ventilation: The home has no mechanical ventilation, but has good natural ventilation.
TG-3
TG-3
TG-1