Data Sheet

Elix ABS P2MC


Electroplating grade

Property Test Condition Unit Standard Value

Rheological properties
Molding shrinkage, normal 60x60x2 % ISO 294-4 0.4 - 0.7
Melt volume-flow rate 220 °C; 10 kg cm³/(10 min) ISO 1133 25
Molding shrinkage, parallel 60x60x2 % ISO 294-4 0.4 - 0.7

Mechanical properties (23 °C/50 % r. h.)


Yield stress 50 mm/min MPa ISO 527-1,-2 40
Tensile Strain at break 50 mm/min % acc. ISO 527-1,-2 > 15
Tensile modulus 1 mm/min MPa ISO 527-1,-2 2200
Flexural strength 2 mm/min MPa ISO 178 62
Flexural modulus 2 mm/min MPa ISO 178 2100
Izod notched impact strength 23 °C kJ/m² ISO 180-1A 23
Izod notched impact strength -30 °C kJ/m² ISO 180-1A 12
Yield strain 50 mm/min % ISO 527-1,-2 2.4
Charpy impact strength 23 °C kJ/m² ISO 179-1eU N
Charpy impact strength -30 °C kJ/m² ISO 179-1eU 150
Charpy notched impact strength 23 °C kJ/m² ISO 179-1eA 24
Charpy notched impact strength -30 °C kJ/m² ISO 179-1eA 14
Ball indentation hardness N/mm² ISO 2039-1 90

Thermal properties
Temperature of deflection under load 1.80 MPa °C ISO 75-1,-2 94
Temperature of deflection under load 0.45 MPa °C ISO 75-1,-2 96
Vicat softening temperature 50 N; 50 °C/h °C ISO 306 95
Burning behavior UL 94 (1.6 mm) 1.6 mm Class UL 94 HB
Coefficient of linear thermal expansion, parallel 23 to 55 °C 10-4/K ISO 11359-1,-2 1.0
Burning rate (US-FMVSS) 2.0 mm mm/min ISO 3795 55
Glow wire test (GWFI) 2.0 mm °C IEC 60695-2-12 700

Electrical properties (23 °C/50 % r. h.)


Relative permittivity 100 Hz - IEC 60250 3.0
Relative permittivity 1 MHz - IEC 60250 2.9
-4
Dissipation factor 100 Hz 10 IEC 60250 50
Dissipation factor 1 MHz 10-4 IEC 60250 80
Volume resistivity Ohm·m IEC 60093 1E13
Surface resistivity Ohm IEC 60093 1E15
Electric strength 1 mm kV/mm IEC 60243-1 37
Comparative tracking index CTI Solution A Rating IEC 60112 600

Other properties (23 °C)


Density g/cm³ ISO 1183 1.030

Page 1 from 2
Edition 01.12.2015 15:04:56
Data Sheet

Elix ABS P2MC


Property Test Condition Unit Standard Value

Processing conditions for test specimens


Injection molding-Melt temperature °C ISO 294 240
Injection molding-Mold temperature °C ISO 294 70
Injection molding-Injection velocity mm/s ISO 294 240

Disclaimer
Disclaimer for sales products
This information and our technical advice - whether verbal, in writing or by way of trials - are given in good faith but without warranty, and this also applies where
proprietary rights of third parties are involved. Our advice does not release you from the obligation to verify the information currently provided - especially that contained
in our safety data and technical information sheets - and to test our products as to their suitability for the intended processes and uses. The application, use and
processing of our products and the products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own
responsibility. Our products are sold and our advisory service is given in accordance with the current version of our General Conditions of Sale and Delivery.
Test values styrenics
Unless specified to the contrary, the values given have been established on standardised test specimens at room temperature. The figures should be regarded as guide
values only and not as binding minimum values. Kindly note that, under certain conditions, the properties can be affected to a considerable extent by the design of the
mould/die, the processing conditions and the colouring. This is valid especially for CTI.
Processing note
Under the recommended processing conditions small quantities of decomposition product may be given off during processing. To preclude any risk to the health and
well-being of the machine operatives, tolerance limits for the work environment must be ensured by the provision of efficient exhaust ventilation and fresh air at the
workplace in accordance with the Safety Data Sheet. In order to prevent the partial decomposition of the polymer and the generation of volatile decomposition products,
the prescribed processing temperatures should not be substantially exceeded. Since excessively high temperatures are generally the result of operator error or defects in
the heating system, special care and controls are essential in these areas.

ELIX Polymers , SL. Crta. Vila-seca a La Pineda, s/n 43110 La Canonja (Tarragona).
[email protected]
© ELIX Polymers

Page 2 from 2
Edition 01.12.2015 15:04:56

You might also like