GE

Digital Energy

D20 Combination
Module
Overview Efficient, Cost Effective
The D20 Combination module is composed of two detachable modules, WESTERM D20 C and WESDAC I/O Solutions
D20 C. The bottom module, WESTERM D20 C, is where all field wirings are terminated. The top module,
• The I/O modularity allows for efficient
WESDAC D20 C, processes the data acquired and communicates this to the main D20 processor, see
distributed I/O installations - minimizing wiring
Figure 2.
and enclosure requirements; this eliminates
The D20C is an I/O module that is typically used for applications where small point-counts are desired. It panel and reduces cost
supports Status Indication, Control Outputs, Analog Inputs and Outputs. • The active/passive design of the WESDAC/
The D20C can be configured with: WESTERM I/O modules allows users to
quickly test, commission, and troubleshoot
• 16 digital inputs via hot swappable WESDAC modules,
• 8 momentary or dual function trip/close control outputs without disturbing wiring connections ;
this significantly speeds up and simplifies
• Optional 16 analog inputs
maintenance activities
• Optional 8 analog inputs and 8 analog outputs
The D20C uses a faster clock speed to meet the increased processing power demand.
Ease of Use
Interposing relays may be supplied using a WESTERM D20KI, as with the D20K.
• To first time users, both the software
A Local/Remote switch is provided to turn off relay coil power, and put the module off-line. An on/off-line configuration setup and hardware
indication is sent to the D20 main processor, which is available to the host as a pseudo-status. installations are trivial; this makes it simple to
install and maintain the combination module
Two DB 9 connectors are provided to allow daisy chaining of the D.20 Link. This link provides the
communication channel over which the main D20 CPU processor can communicate with the WESDAC
D20 C. Power for the WESDAC D20 C is also provided over the same cable assembly.
Flexible and Reliable
A single DB 9 connector is provided for the WESMAINT D20 maintenance port. This port allows
communications between a VT 100 terminal or emulator, and the WESDAC D20 A.
Operations
• The combination of digital input/output and
The address jumper block for the WESDAC D20 A is located on the WESTERM.
analog input/output options makes this
module versatile
• D20C supports up to 16 analog inputs and 8
analog outputs. It supports digital input and
output while ensuring the secure operation of
the control output interface by validating the
initiated and timed control request from the
D20/D200 Substation controller
• I/O modules are available to be ordered with
either a DNP3 communication protocol option
or a Standard/ Redundant D.20 link option.
The D.20 link is a GE proprietary protocol

g imagination at work
Distributed I/O Architecture SCADA Masters
The D20 Remote Terminal Unit (RTU) design is based on a distributed-
processing architecture including real-time data acquisition and control
software. These I/O modules can be located close to the primary equipment
being monitored and controlled as they receive and send data back to the
master D20 main processor.

The I/O modules are intelligent modules that contain on-board


microprocessors and are configured as slave devices to the D20 main
processor. In the Figure 1 pictorial setup, specific I/O processing is distributed
throughout the D20 RTU to the appropriate I/O modules.

The I/O modules support two communication protocols: (1) DNP3 protocol,
and (2) high speed, high-level data link controller (D.20 Link) in the form of
poll and response messages protocol. The peripheral modules have serial
communication ports and various types of field connections.

The hardware construction of each remote I/O module type is similar (see
Figure 2.)

Figure 1: Simple architecture of I/O modules communicating to the D20 RTU

Figure 2: Architecture of I/O logic and termination panels

Acrylic Display
Cover

WESDAC
Logic Panel

WESTERM
Terminal Panel

Terminal Blocks Metal Mounting Plate

2 GEDigitalEnergy.com
Analog Add-On Options ITEM DESCRIPTION

The analog input/output are available as add-on options for the D20C
ANALOG INPUTS
peripheral. They are mounted on the D20 C WESDAC. See Table 1 below. Input Impedance 44M Ohm ±5% (VDC)
Common Mode Rejection 95 dB
Table 1: D20C Daughter Card Options (60 Hz)
Normal Mode Rejection 60 dB
D20C DIGITAL CONTROL ANALOG ANALOG (60 Hz)
PERIPHERAL INPUTS OUTPUTS INPUTS OUTPUTS
Over voltage Rating ±35 VDC (normal mode)
D20C 16 8 - -
ANALOG INPUTS/OUTPUTS
D20C with D20
16 8 16 -
C1 Daughter Board Physical Plug‑in daughter board for 8 unipolar
or bipolar (voltage only) outputs or 8
D20C with D20
16 8 8 8 unipolar current outputs, and 8 bipolar
C2 Daughter Board
inputs @ ±5 V (see Analog Inputs above)
Output Ranges • 0 ‑ 5, 0 ‑ 10, ±5, ±10 V
• 0 ‑ 1, 0 ‑ 5, 0 ‑ 10, 0 ‑ 20 mA
Termination Types Accuracy 0.1% (voltage), 0.15% (current)
D20 Control output module can be ordered with the following field
Resolution 12 bits plus sign
termination options:
Maximum Output 5 kohms @ 5 V out
• Compression:
STATUS INPUTS
Field wiring is terminated directly onto board-mounted screw terminal
compression blocks (#12 AWG [2.05mm] max, blade screwdriver - 0.6 x Physical 16 optically isolated inputs in two groups
of 8. Inputs in one group will share a
3.5 x 100 mm) on the D20 I/O Peripheral
common return and contact wetting.
• DB25: Contact Wetting ±12, ±24, ±48 or ±125 VDC
Field wiring is terminated onto the D20 I/O peripheral through DB25
Current Burden ±3 to ±6 mA per input
connectors
Scan Rate 1.0 ms
• Compression Disconnect:
Field wiring is terminated onto plug-on terminator blocks (#12 AWG Debounce Selectable 1 to 255 ms
[2.05mm] max, blade screwdriver - 0.6 x 3.5 x 100 mm), which then mate SOE Time Resolution 1.0 ms
with board-mounted headers on the D20 I/O Peripheral Overload Rating 500 VDC (common mode to GND)
CONTROL OUTPUTS
Technical Specifications Physical 8 relays plus two Master Trip/Close relays

For a more complete description on the status, analog and control features Output Configurations • 8 T/C pairs
• 6 T/C + 1 R/L pairs
of the D20 C, refer to the respective brochures of the D20S, D20A and D20K • 4 T/C + 2 R/L pairs
modules. • 2 T/C + 3 R/L pairs
• 4 R/L pairs
• 8 isolated Form C contact outputs
Table 2: D20C Specifications
Contact Duration Programmable 1 to 215 ms in 1 ms
ITEM DESCRIPTION intervals or 1 to 215 s in 1 s intervals
(protocol dependent)
Processor 8 bit Freescale 68HC11 MPU
Contact Rating 60 W max, 3 A max, 220 VDC max
Clock 2 MHz MPU clock (1 Form-C or -A contact)
Memory • 24 KB EPROM Coil Status Check Every 500 µs
• 32 KB static RAM
• 512 bytes EEPROM Switches Local enable/disable switch

ANALOG INPUTS Component Isolation Rating 1500 Vrms


Physical Plug in daughter board for 16 bipolar, Dielectric Rating 1000 VDC
differential inputs
D.20 Link Ports 2
Input Adapters Refer to the Index for a list of available
input adapters. Maintenance Port 9600 baud, RS-232

Accuracy ±0.05% (voltage), ±0.1% (current) Power Requirements 20‑60 VDC, 5 W typical; 11 W full load
with 24 V contact wetting
Temperature Coefficient ±10 ppm per °C
Size • D20C assembly: 19"" x 5.25"" x 2.5""
Resolution 14 bits plus sign • D20C analog input & analog input/
output daughter boards: 8.5"" x3"
Conversion Rate • 275 ms for 16 inputs @ 60 Hz
• 328 ms for 16 inputs @ 50 Hz
Dynamic Range of Converter 125% of normalized full scale inputs

GEDigitalEnergy.com 3
Ordering
D20C System Components

D20C System Components Order Code


D20C - * * * * * * * * * Description Equivalent Legacy #
D20C Termination 1 D20C LV (20-60 VDC or D.20 Power) Compression Termination & DB25 For Interposer Relays 517-0169
Options
2 D20CD LV (20-60 VDC or D.20 Power) DB25 Termination 517-0180
3 D20CB LV (20-60 VDC or D.20 Power) Barrier Termination & DB25 For Interposer Relays 517-0326
4 D20CX LV (20-60 VDC or D.20 Power) Compression Disconnect Termination & DB25 For Interposer Relays 517-0217
5 D20CDI 48V LV (20-60 VDC or D.20 Power) Isolated Commons & DB25 For Interposer Relays 517-0333
6 D20CDI 130V LV (20-60 VDC or D.20 Power) Isolated Commons & DB25 For Interposer Relays 517-0263
8 D20C4Z (HV) - 48V Compression Termination 517-0239
9 D20C4Z (HV) - 110V (40-150VDC) Compression Termination 517-0253
A D20C4Z2 (HV) - 220V (40-150VDC) Compression Termination 517-0267
B D20C4Z2 (HV) - 48V (40-150VDC) Compression Termination , Analog Outputs 517-0365
D20C Input/Output 1 D20C - 16 DI, 8 DO
Option
2 D20C1 - 16 DI, 8DO, 16 AI
3 D20C2 - 16 DI, 8 DO, 8 AI, 8 AO
4 D20CHV - 16 DI, 8 DO
5 D20C1HV - 16 DI, 8 DO, 16 AI
6 D20C2HV - 16 DI, 8 DO, 8 AI, 8 AO
D20C Status U Status Wetting Not Required [Available for SDI, CDI, SZ & C4Z Only]
Wetting Options
1 12V Status Wetting
2 24V Status Wetting
3 48V Status Wetting
4 130V Status Wetting
D20C First Group U None
of Analog Adapters
Options (8 AI) 1 Voltage Input Adaptor +/- 1V +/- 5V, +/- 10V DC (set of 8)
2 0.1 mA / 5V Current Input Adaptor (set of 8)
3 0.3 mA / 5V Current Input Adaptor (set of 8)
4 0.5 mA / 5V Current Input Adaptor (set of 8)
5 1 mA / 5V Current Input Adaptor (set of 8)
6 1 mA / 5V Current Input Adaptor (High Precision) (set of 8)
7 1.1 mA / 5V Current Input Adaptor (set of 8)
8 1.25 mA / 5V Current Input Adaptor (set of 8)
9 1.5 mA / 5V Current Input Adaptor (set of 8)
A 2 mA / 5V Current Input Adaptor (set of 8)
B 2 mA / 5V Current Input Adaptor (High Precision 0.01%) (set of 8)
C 2.5 mA / 5V Current Input Adaptor (set of 8)
D 2mA / 1V Current Input Adaptor (set of 8)
E 12.8mA / 5V Current Input Adaptor (set of 8)
F 20mA / 5V Current Input Adaptor (set of 8)
G 50mA / 5V Current Input Adaptor (set of 8)

4 GEDigitalEnergy.com
D20C System Components Order Code (continued)
D20C - * * * * * * * * * Description Equivalent Legacy #
D20C Second Group U None
of Analog Adapters (8 1 Voltage Input Adaptor +/- 1V +/- 5V, +/- 10V DC (set of 8)
AI or 8 A0)
2 0.1 mA / 5V Current Input Adaptor (set of 8)
3 0.3 mA / 5V Current Input Adaptor (set of 8)
4 0.5 mA / 5V Current Input Adaptor (set of 8)
5 1 mA / 5V Current Input Adaptor (set of 8)
6 1 mA / 5V Current Input Adaptor (High Precision) (set of 8)
7 1.1 mA / 5V Current Input Adaptor (set of 8)
8 1.25 mA / 5V Current Input Adaptor (set of 8)
9 1.5 mA / 5V Current Input Adaptor (set of 8)
A 2 mA / 5V Current Input Adaptor (set of 8)
B 2 mA / 5V Current Input Adaptor (High Precision 0.01%) (set of 8)
C 2.5 mA / 5V Current Input Adaptor (set of 8)
D 2mA / 1V Current Input Adaptor (set of 8)
E 12.8mA / 5V Current Input Adaptor (set of 8)
F 20mA / 5V Current Input Adaptor (set of 8)
G 50mA / 5V Current Input Adaptor (set of 8)
H Voltage Output Adaptor (set of 8)
I 1 mA Current Output Adaptor (set of 8)
J 5 mA Current Output Adaptor (set of 8)
K 10 mA Current Output Adaptor (set of 8)
L 20 mA Current Output Adaptor [0-20; 4-20] (set of 8)
D20C PCommon U None
Option 1 PCommon2 300
2 PCommon2 221
3 PCommon2 209
4 PCommon2 305
D20C Cable Option U Cable Not Required
1 D.20 Cable 12 Inches Long
2 D.20 Cable 18 Inches Long
3 D.20 Cable 24 Inches Long
4 D.20 Cable 36 Inches Long
5 D.20 Cable 48 Inches Long
6 D.20 Cable 72 Inches Long
7 D.20 Cable 96 Inches Long
8 D.20 Cable 120 Inches Long
D.20 Terminator U D.20 Terminator Not Required
Option 1 D.20 Terminator (One Required per D.20 Link)
D.20 Duct Panel U Duct Panel Not Required
1 Cable Duct Panel, Tie Wrap Connections
2 Two Cable Duct Panels, Tie Wrap Connections
3 Cable Duct Panel, No Through Holes
4 Two Cable Duct Panels, No Through Holes
5 Cable Duct Panel, Through Holes at Each End
6 Two Cable Duct Panels, Through Holes at Each End

Please note
1. For the rules regarding the combination of various options to build an 3. The order defined in the ordering guide may not be final and can only be
order code, visit the online web: accepted once GE has reviewed and accepted the order. This document is
http://store.gedigitalenergy.com/ViewProd.asp?Model=D20C1 only meant as a guide and by no means will portray the final order.
2. This ordering guide should ONLY be used with reference to the product 4. GE reserves the rights to change or modify the document without notice.
documentation and it is assumed the user has read those documents. The user is responsible to contact GE before placing an order to ensure
The ordering guide is for the use of experienced users who have extensive the accuracy of the order code built.
knowledge in the area and the products.

GEDigitalEnergy.com 5
Ordering
D20C Spare Components
D20C Spare Components Order Code
D20CS - * * * * * * * * * * * Description
D20C Type U None
(T-1) D20C LV (20-60VDC or D.20 Power) Compression Termination FOR DB25 for interposer relays
(T-2) D20CD LV (20-60VDC or D.20 Power) DB25 Termination
(T-3) D20 CB LV (20-60VDC or D.20 Power) Barrier Termination & DB25 For Interposer relays
(T-4) D20CX LV (20-60VDC or D.20 Power) Compression Disconnect Termination & DB25 for interposer relays
(T-5) D20C4Z2 HV - 48V DI Compression Disconnect Termination
(T-6) D20CDI LV (20-60VDC or D.20 Power) 48V Isolated Common & DB25 for interposer relays
(T-7) D20CDI LV (20-60VDC or D.20 Power) 130V Isolated Common & DB25 for interposer relays
(T-8) D20C4Z HV - 48V DI Compression Termination, Analog Input Only
(T-9) D20C4Z HV - 110V DI Compression Termination, Analog Input Only
(T-A) D20C4Z2 HV 24V DI Compression Termination, Analog Input & Output Allowed
(T-C) D20C4Z2 HV Compression Disconnect Termination, 48V DI
(T-D) D20C4Z2 HV Compression Disconnect Termination, 220V DI
(D-1) WESDAC D20C LV
(D-2) WESDAC D20C HV
(3-1) WESDAC D20C LV, DNP3 Communications
(3-2) WESDAC D20C HV, DNP3 Communications
D20C Input/Output U None
Option 1 D20C0 - 16 DI, 8 DO
2 D20C1 - 16 DI, 8DO, 16 AI
3 D20C2 - 16 DI, 8 DO, 8 AI, 8 AO
4 D20CHV - 16 DI, 8 DO
5 D20C1HV - 16 DI, 8 DO, 16 AI
6 D20C2HV - 16 DI, 8 DO, 8 AI, 8 AO
8 WESTERM Configuration for AI (Req for D20C4Z2)
9 WESTERM Configuration for AI & AO (Req for D20C4Z2)
A WESTERM 16DI, 8DO, 16AI [540-0205] (WESTERM)
B WESTERM 16DI, 8DO, 8AI, 8AO [540-0227] (WESTERM)
D20C Status Wetting U None
Options 1 12V Status Wetting
2 24V Status Wetting
3 48V Status Wetting
4 130V Status Wetting [LV] Only
5 130V Status Wetting [HV] Only
D20C First Group U None - Adapter not required
of Analog Adapters 1 Voltage Input Adaptor +/- 1V +/- 5V, +/- 10V DC (set of 8)
Options (8 AI)
2 0.1 mA / 5V Current Input Adaptor (set of 8)
3 0.3 mA / 5V Current Input Adaptor (set of 8)
4 0.5 mA / 5V Current Input Adaptor (set of 8)
5 1 mA / 5V Current Input Adaptor (set of 8)
6 1 mA / 5V Current Input Adaptor (High Precision) (set of 8)
7 1.1 mA / 5V Current Input Adaptor (set of 8)
8 1.25 mA / 5V Current Input Adaptor (set of 8)
9 1.5 mA / 5V Current Input Adaptor (set of 8)
A 2 mA / 5V Current Input Adaptor (set of 8)
B 2 mA / 5V Current Input Adaptor (High Precision 0.01%) (set of 8)
C 2.5 mA / 5V Current Input Adaptor (set of 8)
D 2mA / 1V Current Input Adaptor (set of 8)
E 12.8mA / 5V Current Input Adaptor (set of 8)
F 20mA / 5V Current Input Adaptor (set of 8)
G 50mA / 5V Current Input Adaptor (set of 8)

6 GEDigitalEnergy.com
D20C Spare Components Order Code (continued)
D20CS - * * * * * * * * * * * Description
D20C Second Group of U None - Adapter not required
Analog Adapters (8 AI 1 Voltage Input Adaptor +/- 1V +/- 5V, +/- 10V DC (set of 8)
or 8 A0)
2 0.1 mA / 5V Current Input Adaptor (set of 8)
3 0.3 mA / 5V Current Input Adaptor (set of 8)
4 0.5 mA / 5V Current Input Adaptor (set of 8)
5 1 mA / 5V Current Input Adaptor (set of 8)
6 1 mA / 5V Current Input Adaptor (High Precision) (set of 8)
7 1.1 mA / 5V Current Input Adaptor (set of 8)
8 1.25 mA / 5V Current Input Adaptor (set of 8)
9 1.5 mA / 5V Current Input Adaptor (set of 8)
A 2 mA / 5V Current Input Adaptor (set of 8)
B 2 mA / 5V Current Input Adaptor (High Precision 0.01%) (set of 8)
C 2.5 mA / 5V Current Input Adaptor (set of 8)
D 2mA / 1V Current Input Adaptor (set of 8)
E 12.8mA / 5V Current Input Adaptor (set of 8)
F 20mA / 5V Current Input Adaptor (set of 8)
G 50mA / 5V Current Input Adaptor (set of 8)
H Voltage Output Adaptor (set of 8)
I 1 mA Current Output Adaptor (set of 8)
J 5 mA Current Output Adaptor (set of 8)
K 10 mA Current Output Adaptor (set of 8)
L 20 mA Current Output Adaptor [0-20; 4-20] (set of 8)
D.20 Link Options U None
S Standard D.20 Link
L WESDAC Redundant D.20 Link & Dual Power Supply option
R WESTERM Redundant D.20 Link & Dual Power Supply option (540-0313)
D20C PCommon2 U None
1 PCommon2 221
2 PCommon2 305
D20C DNP3 Digital U None
Input Points Config A Single Point
Option
B Double Point
C Transition Counter
D Form C Counter
D20C DNP3 I/O Analog U None
Input Frequency Config A 50 Hz Configuration
Option
B 60 Hz Configuration
D20C DNP3 Analog U None
Output Config Option A Unipolar, 5V Analog Outputs
B Bipolar, 5V Analog Outputs
C Unipolar, Current Analog Outputs
D20C Daughter Card U None
Options A WESDAC D20C LV Wesmaint Interface card
B WESDAC D20C HV Wesmaint Interface card [540-0209]
C WESDAC D20C LV 8 Analog Input / 8 Analog Output expansion card [540-0166]
D WESDAC D20C LV 16 Analog Input expansion card [540-0159]
E WESDAC D20C HV 16 Analog Input expansion card [540-0205]
F WESDAC D20C HV 8 Analog Input / 8 Analog Output expansion card [540-0227]

Please note
1. For the rules regarding the combination of various options to build an 3. The order defined in the ordering guide may not be final and can only be
order code, visit the online web: accepted once GE has reviewed and accepted the order. This document is
http://store.gedigitalenergy.com/ViewProd.asp?Model=D20C+Parts only meant as a guide and by no means will portray the final order.
2. This ordering guide should ONLY be used with reference to the product 4. GE reserves the rights to change or modify the document without notice.
documentation and it is assumed the user has read those documents. The user is responsible to contact GE before placing an order to ensure
The ordering guide is for the use of experienced users who have extensive the accuracy of the order code built.
knowledge in the area and the products

GEDigitalEnergy.com 7
D20C Spare Cross-Reference
LEGACY PART NUMBER AND DESCRIPTION SMART CATALOG NUMBER PREFIX AND DESCRIPTION
D20 COMBINATION WESTERM MODULES - D20 COMBINATION WESTERM MODULES - NEW PART NUMBER PREFIX
LEGACY PART NUMBER
(517-0169) - WESTERM D20C TYPE 1 VERSION 1 (D20CS-T-1) - D20C LV (20-60VDC or D.20 Power), Compression Termination & DB25 for Interposer relays
(517-0180 ) - WESTERM D20 CD (D20CS-T-2) - D20CD LV (20-60VDC or D.20 Power), DB25 Termination
(517-0326) - WESTERM D20 CB (D20CS-T-3) - D20CB LV (20-60VDC or D.20 Power), Barrier Termination & DB25 for Interposer relays
(517-0217) - WESTERM D20 CX W/TB PLUGS (D20CS-T-4) - D20CX LV (20-60VDC or D.20 Power), Compression Disconnect Termination & DB25 for Interposer relays
(517-0333) - WESTERM D20 CDI, 48V (D20CS-T-6) - D20CDI LV (20-60VDC or D.20 Power), 48V Isolated Common & DB25 for Interposer relays
(517-0263) - WESTERM D20 CDI, 130V (D20CS-T-7) - D20CDI LV (20-60VDC or D.20 Power), 130V Isolated Common & DB25 for Interposer relays
(517-0239) - WESTERM D20 C4Z, 48V DI (D20CS-T-8) - D20C4Z HV 48V DI Compression Termination Analog Input Only
(517-0325) - WESTERM D20 C4Z2, 48V DI (D20CS-T-5) - D20C4Z HV 48V DI Compression DisconnectTermination
(517-0253) - WESTERM D20 C4Z 110V DI (D20CS-T-9) - D20C4Z HV 110V DI Compression Termination Analog Input Only
(517-0362) - WESTERM D20 C4Z2 24V DI (D20CS-T-A) - D20C4Z2 HV 24V DI Compression Termination Analog Input & Output Allowed
(517-0363) - WESTERM D20 C4Z2 WITH PLUGS, 48V DI (D20CS-T-C) - D20C4Z2 HV 48V DI Compression Disconnect Termination
(517-0267) - WESTERM D20 C4Z2 (220V) (D20CS-T-D) - D20C4Z2 HV 220V DI Compression Disconnect Termination
D20 COMBINATION WESDAC MODULES - D20 COMBINATION WESDAC MODULES - NEW PART NUMBER PREFIX
LEGACY PART NUMBER
(504-0002) - WESDAC D20C+ (D20CS-D-1) - WESDAC D20C LV
(504-0003) - WESDAC D20C HV (D20CS-D-2) - WESDAC D20C HV
D20 COMBINATION DNP 3 MODULES - D20 COMBINATION DNP 3 MODULES - NEW PART NUMBER PREFIX
LEGACY PART NUMBER
(504-0302) - DNP I/O LV MODULE - COMBINATION (D20CS-3-1)- WESDAC D20C LV, DNP3 Communications
(504-0303) - DNP I/O HV MODULE - COMBINATION (D20CS-3-2)- WESDAC D20C HV, DNP3 Communications
D20 COMBINATION DIGITAL INPUT ADAPTER - D20 COMBINATION DIGITAL INPUT ADAPTER - NEW PART NUMBER
LEGACY PART NUMBER
(245-0031) - D20 C 12V Digital Input Adapter (D20CS-U-U-U-1-U-U-U-U-U-U-U) - 12V Digital Input Adapter [245-0031]
(245-0030 (4x), 245-0029 (2x)) - D20 C 24V Digital Input Adapter (D20CS-U-U-U-2-U-U-U-U-U-U-U) - 24V Digital Input Adapter [ 245-0030 (4x), 245-0029 (2x)]
(245-0004) - D20 C 48V Digital Input Adapter (D20CS-U-U-U-3-U-U-U-U-U-U-U) - 48V Digital Input Adapter [245-0004]
(530-0133) - D20 C 130V Digital Input Adapter for LV (D20CS-U-U-U-4-U-U-U-U-U-U-U) - 130V Digital Input Adapter for LV [530-0133]
(245-0012) - D20 C 220V Digital Input Adapter for HV (D20CS-U-U-U-5-U-U-U-U-U-U-U) - 130V Digital Input Adapter for HV [245-0012]
D20 COMBINATION FIRST SLOT OF ANALOG ADAPTERS - D20 COMBINATION FIRST SLOT OF ANALOG ADAPTERS - NEW PART NUMBER
LEGACY PART NUMBER
(530-0004) - D20C Voltage Input Adapter (D20CS-U-U-U-U-1-U-U-U-U-U-U) - Voltage Input Adapter [530-0004]
(530-0087) - 0.1mA to 5V Current Input Adapter (D20CS-U-U-U-U-2-U-U-U-U-U-U) - 0.1mA to 5V Current Input Adapter [530-0087]
(530-0088) - 0.3mA to 5V Current Input Adapter (D20CS-U-U-U-U-3-U-U-U-U-U-U) - 0.3mA to 5V Current Input Adapter [530-0088]
(530-0089) - 0.5mA to 5V Current Input Adapter (D20CS-U-U-U-U-4-U-U-U-U-U-U) - 0.5mA to 5V Current Input Adapter [530-0089]
(530-0050) - 1 mA to 5V Current Input Adapter (D20CS-U-U-U-U-5-U-U-U-U-U-U) - 1 mA to 5V Current Input Adapter [530-0050]
(530-0090) - 1 mA to 5V Current Input Adapter [High Precision] (D20CS-U-U-U-U-6-U-U-U-U-U-U) - 1 mA to 5V Current Input Adapter [High Precision] [530-0090]
(530-0091) - 1.1 mA to 5V Current Input Adapter (D20CS-U-U-U-U-7-U-U-U-U-U-U) - 1.1 mA to 5V Current Input Adapter [530-0091]
(530-0094) - 1.25 mA to 5V Current Input Adapter (D20CS-U-U-U-U-8-U-U-U-U-U-U) - 1.25 mA to 5V Current Input Adapter [530-0094]
(530-0095) - 1.5 mA to 5V Current Input Adapter (D20CS-U-U-U-U-9-U-U-U-U-U-U) - 1.5 mA to 5V Current Input Adapter [530-0095]
(530-0051) - 2 mA to 5V Current Input Adapter (D20CS-U-U-U-U-A-U-U-U-U-U-U) - 2 mA to 5V Current Input Adapter [530-0051]
(530-0108) - 2 mA to 5V Current Input Adapter [High Precision] (D20CS-U-U-U-U-B-U-U-U-U-U-U) - 2 mA to 5V Current Input Adapter [High Precision] [530-0108]
(530-0086) - 2.5 mA to 5V Current Input Adapter (D20CS-U-U-U-U-C-U-U-U-U-U-U) - 2.5 mA to 5V Current Input Adapter [530-0085]
(530-0045) - 2mA to 1V Current Input Adapter (D20CS-U-U-U-U-D-U-U-U-U-U-U) - 2mA to 1V Current Input Adapter [530-0045]
(530-0131) - 12.8 mA to 5V Current Input Adapter (D20CS-U-U-U-U-E-U-U-U-U-U-U) - 12.8 mA to 5V Current Input Adapter [530-0131]
(530-0052) - 20 mA to 5V Current Input Adapter (D20CS-U-U-U-U-F-U-U-U-U-U-U) - 20 mA to 5V Current Input Adapter [530-0052]
(530-0086) - 50 mA to 5V Current Input Adapter (D20CS-U-U-U-U-G-U-U-U-U-U-U) - 50 mA to 5V Current Input Adapter [530-0086]

8 GEDigitalEnergy.com
D20C Spare Cross-Reference (continued)
LEGACY PART NUMBER AND DESCRIPTION SMART CATALOG NUMBER PREFIX AND DESCRIPTION
D20 COMBINATION SECOND SLOT OF ANALOG ADAPTERS- D20 COMBINATION SECOND SLOT OF ANALOG ADAPTERS - NEW PART NUMBER
LEGACY PART NUMBER
(530-0004) - D20C Voltage Input Adapter (D20CS-U-U-U-U-U-1-U-U-U-U-U) - Voltage Input Adapter [530-0004]
(530-0087) - 0.1mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-2-U-U-U-U-U) - 0.1mA to 5V Current Input Adapter [530-0087]
(530-0088) - 0.3mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-3-U-U-U-U-U) - 0.3mA to 5V Current Input Adapter [530-0088]
(530-0089) - 0.5mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-4-U-U-U-U-U) - 0.5mA to 5V Current Input Adapter [530-0089]
(530-0050) - 1 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-5-U-U-U-U-U) - 1 mA to 5V Current Input Adapter [530-0050]
(530-0090) - 1 mA to 5V Current Input Adapter [High Precision] (D20CS-U-U-U-U-U-6-U-U-U-U-U) - 1 mA to 5V Current Input Adapter [High Precision] [530-0090]
(530-0091) - 1.1 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-7-U-U-U-U-U) - 1.1 mA to 5V Current Input Adapter [530-0091]
(530-0094) - 1.25 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-8-U-U-U-U-U) - 1.25 mA to 5V Current Input Adapter [530-0094]
(530-0095) - 1.5 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-9-U-U-U-U-U) - 1.5 mA to 5V Current Input Adapter [530-0095]
(530-0051) - 2 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-A-U-U-U-U-U) - 2 mA to 5V Current Input Adapter [530-0051]
(530-0108) - 2 mA to 5V Current Input Adapter [High Precision] (D20CS-U-U-U-U-U-B-U-U-U-U-U) - 2 mA to 5V Current Input Adapter [High Precision] [530-0108]
(530-0086) - 2.5 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-C-U-U-U-U-U) - 2.5 mA to 5V Current Input Adapter [530-0086]
(530-0045) - 2mA to 1V Current Input Adapter (D20CS-U-U-U-U-U-D-U-U-U-U-U) - 2mA to 1V Current Input Adapter [530-0045]
(530-0131) - 12.8 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-E-U-U-U-U-U) - 12.8 mA to 5V Current Input Adapter [530-0131]
(530-0052) - 20 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-F-U-U-U-U-U) - 20 mA to 5V Current Input Adapter [530-0052]
(530-0086) - 50 mA to 5V Current Input Adapter (D20CS-U-U-U-U-U-G-U-U-U-U-U) - 50 mA to 5V Current Input Adapter [530-0086]
LEGACY PART NUMBER - OUTPUT ADAPTERS NEW PART NUMBER - OUTPUT ADAPTERS
(530-0083) - Voltage Output Adapter (D20CS-U-U-U-U-U-H-U-U-U-U-U) - Voltage Output Adapter [530-0083]
(530-0079) - 1mA Current Output Adapter (D20CS-U-U-U-U-U-I-U-U-U-U-U) - 1mA Current Output Adapter [530-0079]
(530-0080) - 5mA Current Output Adapter (D20CS-U-U-U-U-U-J-U-U-U-U-U) - 5mA Current Output Adapter [530-0080]
(530-0081) - 10mA Current Output Adapter (D20CS-U-U-U-U-U-K-U-U-U-U-U) - 10mA Current Output Adapter [530-0081]
(530-0082) - 20mA Current Output Adapter (D20CS-U-U-U-U-U-L-U-U-U-U-U) - 20mA Current Output Adapter [530-0082]
D20 COMBINATION WESDAC DAUGHTER CARDS - D20 COMBINATION WESDAC DAUGHTER CARD MODULES - NEW PART NUMBER
LEGACY PART NUMBER
(540-0162) - WESDAC D20C D.20 Wesmaint Interface (LV) (D20CS-U-U-U-U-U-U-U-U-U-U-A) - WESDAC D20C LV Wesmaint Interface Module [540-0162]
(540-0209) - WESDAC D20C D.20 Wesmaint Interface (HV) (D20CS-U-U-U-U-U-U-U-U-U-U-B) - WESDAC D20C HV Wesmaint Interface Module [540-0209]
(540-0166) - WESDAC D20C Analog I/O (D20CS-U-U-U-U-U-U-U-U-U-U-C) - WESDAC D20C LV 8 Analog Input / 8 Analog Ouput Expansion Module [540-0166]
(540-0159) - WESDAC D20C Analog I/P (LV) (D20CS-U-U-U-U-U-U-U-U-U-U-D) - WESDAC D20C LV 16 Analog Input Expansion Module [540-0159]
(540-0205) - WESDAC D20C Analog I/P (HV) (D20CS-U-U-U-U-U-U-U-U-U-U-E) - WESDAC D20C HV 16 Analog Input Expansion Module [540-0205]
(540-0227) - WESDAC D20 CHV Analog I/O DB (D20CS-U-U-U-U-U-U-U-U-U-U-F) - WESDAC D20C HV 8 Analog Input / 8 Analog Ouput Expansion Module [540-0227]

GEDigitalEnergy.com 9
GE Digital Energy
650 Markland St.
Markham, ON
Canada L6C 0M1
+1 877-605-6777 (toll free in North America)
+1 678-844-6777 (direct number)
[email protected]

GEDigitalEnergy.com

g
Copyright 2014, General Electric Company.
GE and the GE monogram are trademarks of the General Electric Company.
GE Digital Energy reserves the right to make changes to specifications of products described at any
imagination at work time without notice and without obligation to notify any person of such changes.
GEA-12802A(E)
English
140627

You might also like