TO DEDUCTION OF MASS FLOW RATE FOR HELICAL HEAT EXCHANGER AT
MULTIPLE CROSS-SECTIONS USING CFD
Surendra Kumar Vishwakarma*, Sanjay Kumbhare, K.K. Thakur
*PG Student, Mechanical Engineering Department, Patel Group of Institution, Bhopal, India
Asso. Professor,Mechanical Engineering Department, Patel Group of Institution, Bhopal, India
Asso. Professor,Mechanical Engineering Department, Patel Group of Institution, Bhopal, India
DOI: 10.5281/zenodo.157583
ABSTRACT
Enhancing the heat transfer by the use of helical coils has been studied and researched by many researchers, because
the fluid dynamics inside the pipes of a helical coil heat exchanger offer certain advantages over the straight tubes,
shell and tube type heat exchanger, in terms of better heat transfer and mass transfer coefficients. Various
configurations of coil structure are possible, and the configuration in which there is a series of vertically stacked
helically coiled tubes is the most common type. This configuration offers a high compact structure and a high
overall heat transfer coefficient; hence helical coil heat exchangers are widely used in industrial applications such as
power sector, nuclear power generation, food processing plants, heat recovery systems, refrigeration, food industry,
industrial HVACs etc. Convective heat transfer between a surface and the surrounding fluid in a heat exchanger has
been a major issue and a topic of study in the recent years. In this particular study, an attempt has been made to
analyze the effect of mass flow rate from a three different cross-sections on the helical tube, where the hot fluid
flowing in tube and outer surface of tube having less temperature then hot fluid. Different cross-sections of the pipes
are taken into consideration while running the analysis. The contours of pressure, temperature, velocity magnitude
and the mass transfer rate from the tubes were calculated and plotted using ANSYS FLUENT 14.5 where the
governing equations of mass, momentum and energy transfer were solved simultaneously, using the k-Ԑ two
equations turbulence model. The fluid flowing through the tube was taken as water.
KEYWORDS: Helical coil heat exchanger, CFD or Computational fluid dynamics, Conjugate mass transfer,
Geometric configurations, Numerical simulation.
INTRODUCTION
Heat exchangers are one of the mostly used equipment in the process industries. Heat exchangers are used to
transfer heat between two process streams. One can realize their usage that any process which involve cooling,
heating, condensation, boiling or evaporation will require a heat exchanger for these purpose. Process fluids,
usually are heated or cooled before the process or undergo a phase change. Different heat exchangers are named
according to their application. For example, heat exchangers being used to condense are known as condensers,
similarly heat exchanger for boiling purposes are called boilers. Performance and efficiency of heat exchangers are
measured through the amount of heat transfer using least area of heat transfer and pressure drop. A better
presentation of its efficiency is done by calculating over all heat transfer coefficient. Pressure drop and area required
for a certain amount of heat transfer, provides an insight about the capital cost and power requirements
(Running cost) of a heat exchanger. Usually, there is lots of literature and theories to design a heat exchanger
according to the requirements.
Helical coil heat exchanger has excellent heat exchanger because of far compact and high heat transfer efficiency.
This helical coil is installed in a shell another fluid is circulated around outside of the tube, leads to transfer the heat
LITERATURE REVIEW
Daniel Flórez-Orrego, Walter Arias, Diego Lopez and Hector Velasquez 2012 [1] have worked on the single phase
cone shaped helical coil heat exchanger. The study showed the flow and the heat transfer in the heat exchanger. An
empirical correlation was proposed from the experimental data for the average Nusselt number and a deviation of
23% was found.
J. S. Jayakumar 2008 [2] observed that the use of constant values for the transfer and thermal properties of the fluid
resulted in inaccurate heat transfer coefficients. Based on the CFD analysis results a correlation was developed in
order to evaluate the heat transfer coefficient of the coil. Timothy J. Rennie 2004 [3] studied the heat transfer
characteristics of a double pipe helical heat exchanger for both counter and parallel flow. Both the boundary
conditions of constant heat flux and constant wall temperature were taken. The study showed that the results from
the simulations were within the range of the pre-obtained results. For dean numbers ranging from 38 to 350 the
overall heat transfer coefficients were determined. J. S. Jayakumar, S. M. Mahajani, J. C. Mandal, Rohidas Bhoi
2008 [4] studied the constant thermal and transport properties of the heat transfer medium and their effect on the
prediction of heat transfer coefficients. Arbitrary boundary conditions were not applicable for the determination of
heat transfer for a fluid-to-fluid heat exchanger. An experimental setup was made for studying the heat transfer and
also CFD was used for the simulation of the heat transfer.
Usman Ur Rehman 2011 [5] studied the heat transfer and flow distribution in a shell and tube heat exchanger and
compared them with the experimental results. The model showed an average error of around 20% in the heat transfer
and the pressure difference. The study showed that the symmetry of the plane assumption worked well for the length
of the heat exchanger but not in the outlet and inlet regions. Nawras H. Mostafa, Qusay R. Al-Hagag 2012 [6]
studied on the mechanical and thermal performance of elliptical tubes used for polymer heat exchangers. The
mechanical analysis showed that the streamlined shape of the outer tube had an optimal thermal performance. A set
of design curves were generated from which a number of geometries of the tube and different materials can be easily
selected in order to meet the deformation constraints. A finite element solution was determined for strain as a
function of the material of the tube. Amitkumar S. Puttewar, A.M. Andhare 2015[7] focuses on the designing of
shell and helical coil heat exchanger and its thermal evaluation with counter flow configuration. The thermal
P. P. Gavade, S.S. Malgave, D.D. Patil, H.S. Bhore, V. V. Wadkar,2015 [8] Here the fluid which surrounds a heat
source receives heat, becomes less dense and rises. The working fluid that is surrounding the high temperature fluid
is cooled and then moves in to replace it. After that cooler fluid gets heated and the process continues, resulting
convection current. Forced convection in a heat exchanger is the flow of heat from one moving stream to another
stream through the wall of the pipe. Mandhapati Raju, Sudarshan Kumar 2010 [9] studied hydrogen refueling in a
metal hydride based automotive hydrogen storage system is an exothermic reaction and therefore an efficient heat
exchanger is required to remove the heat for fast refueling. In this paper a helical coil heat exchanger embedded in a
sodium alanate bed is modeled using COMSOL. Sodium alanate is present in the shell and the coolant flows through
the helical tube. A three-dimensional COMSOL model is developed to simulate the exothermic chemical reactions
and heat transfer. Satish. B. Ingle, Snehal S. Borkar 2016 [10] the purpose of this study is to determine the relative
advantage of using a helically coiled heat exchanger against a straight tube heat exchanger. It is found that the heat
transfer in helical circular tubes is higher as compared to Straight tube due to their shape. Helical coils offer
advantageous over straight tubes due to their compactness and increased heat transfer coefficient. Swapnil Ahire,
Purushottam Shelke, Bhalchandra Shinde, Nilesh Totala 2014 [11] observed heat recovery is the capture of energy
contained in fluids otherwise that would be lost from a facility. Heat sources may include heat pumps, chillers,
steam condensate lines, hot flue gases from boiler, hot air associated with kitchen and laundry facilities, exhaust
gases of the engines, power-generation equipment. Pramod S. Purandarea, Mandar M. Leleb, Rajkumar Gupta 2012
[12] studied that helical coil configuration is very effective for heat exchangers and chemical reactors because they
can accommodate a large heat transfer area in a small space, with high heat transfer coefficients. B. Chinna
Ankanna, B. Sidda Reddy 2014 [13] this paper focus on an increase in the effectiveness of a heat exchanger and
analysis of various parameters that affect the effectiveness of a heat exchanger and also deals with the performance
analysis of heat exchanger by varying various parameters like number of coils, flow rate and temperature.
Amol Andhare, V M Kriplani, J P Modak 2014 [14] in the present work the convective heat transfer coefficients of a
helical coil heat exchanger are investigated experimentally. Three helical coils of different curvature ratio and pitch
are arranged horizontally in a shell and are tested for counter flow arrangement. Hot water is made to flow through
the helical coil and the cold water through the shell. Jay J. Bhavsar, V K. Matawala, S. Dixit 2013 [15] studied
Spiral tube heat exchangers are known as excellent heat exchanger because of far compact and high heat transfer
efficiency. An innovative spiral tube heat exchanger is designed for particular process engineering. Ramnaresh Patel
, Dharmendra Yadav 2015 [16] studied Enlarging the transformation of heat by the use of Shell And Tube heat
exchanger has been studied and researched by many researchers, because the dynamics of fluid inside the pipes of a
Shell And Tube heat exchanger offer certain advantages over the shell and tube type, straight tubes heat exchanger,
in terms of better transformation of heat and mass transfer coefficients. Shiva Kumara, K.Vasudev Karantha 2013
[17] Heat exchangers are the important equipments with a variety of industrial applications including power plants,
chemical, refrigeration and air conditioning industries. Helically coiled heat exchangers are used in order to obtain a
large heat transfer area per unit volume and to enhance the heat transfer coefficient on the inside surface. This paper
deals with the CFD simulation of helical coiled tubular heat exchanger used for cooling water under constant wall
temperature conditions.
GEOMETRIC MODELING
Modeling
The modeled heat exchanger used for present simulation is helical coil type with circular, rectangular & triangular
cross-sections. The modeled assembly consists of inlet, exit and surface of helical coil heat exchanger. Inlet area and
outlet area of heat exchanger kept constant while cross-section of heat exchanger has been varied. Modeling of heat
exchanger has been done in Ansys ICEM CFD 14.5. The 3-D view of heat exchanger of different cross-section is
shown from fig. 1 to 3.
Fig 1: Modeled view of helical coil heat exchanger with circular cross-section
Fig 2: Modeled view of helical coil heat exchanger with rectangular cross-section
Fig 3: Modeled view of helical coil heat exchanger with triangular cross-section
Boundary Conditions
Boundary conditions are used according to need of the model. The inlet and outlet conditions are defined as velocity
inlet and pressure outlet. As this is a cross flow with one tube so there are respective inlet and outlets. The walls are
separately specified with respective boundary conditions. No slip condition is considered for wall. The details about
all boundary conditions can be seen in the table below:
Table 1. Boundary Conditions
- Boundary condition type Velocity Magnitude Temperature
Inlet Velocity Inlet 0.5 (m/s) 350
Outlet Pressure Outlet 0.5 (pascal) 300
CONCLUSION
The pressure is reducing with very small amount in fig.4, and consequently velocity is varying. This calculate that
the value of mass flow rate is 7.018x10-5 kg/s . Fig. 5 shows the pressure and velocity changes in small ranges and
further calculating value of mass flow rate is 1.113x10 -6 kg/s. Fig. 6 shows slowly variation in pressure and velocity
and calculating the value of mass flow rate is 3.793x10 -6. Also found that pressure is being reducing and
respectively velocity is increasing under small variations because it is inversely proportional to each other as seen in
Figures 4 to 6.
The computation and comparison of different mass flow rate of various geometric configurations using CFD will
help to optimize shape of cross-sections of helical heat exchanger. In this dissertation Computational Fluid
Dynamics (CFD) approach has been used to predict the optimum cross-section of different cross-section of helical
coil heat exchanger at same initial velocity.
In present case it may be concluded that mass flow rate of circular cross-section is better than other two geometric
configurations.
REFERENCES
1. Experimental and CFD study of a single phase cone-shaped helical coiled heat exchanger: an empirical
correlation by Daniel Flórez-Orrego, ECOS June 26-29, 2012.
2. Helically Coiled Heat Exchangers by J.S.Jayakumar 2008.
3. Numerical And Experimental Studies of a Double pipe Helical Heat Exchanger by Timothy John Rennie,
Dept. of Bio-resource Engg. McGill University, Montreal August 2004.
4. Experimental and CFD estimation of heat transfer in helically coiled heat exchangers by J.S. Jayakumar,
S.M. Mahajani, J.C. Mandal, P.K. Vijayan, and Rohidas Bhoi, 2008, Chemical Engg Research and Design
221-232.
5. Heat Transfer Optimization of Shell-and-Tube Heat Exchanger through CFD Studies by Usman Ur
Rehman, 2011, Chalmers University of Technology.
6. Structural and Thermal Analysis of Heat Exchanger with Tubes of Elliptical Shape by Nawras H. Mostafa
Qusay R. Al-Hagag, IASJ, 2012,Vol-8 Issue-3.
7. Design and Thermal Evaluation of Shell and Helical Coil Heat Exchanger by Amitkumar S. Puttewar, A.M.
Andhare, International Journal of Research in Engineering and Technology Volume: 04 Issue: 01 ,Jan-
2015.
8. “Analysis of Tub- in-Tube Helical Coil & Straight Tube Heat Exchanger” by P. P. Gavade, S.S. Malgave,
D.D. Patil, H.S. Bhore, V. V. Wadkar, Journal of Mechanical Engineering and Technology (JMET)
Volume 3, Issue 2, July-Dec 2015, pp. 14-19.