Mars 1200 2
Mars 1200 2
1. Tools: a measuring tape, an adjustable wrench, an impact drill and a small screwdriver (included
in the package).
2. Material: a PVC anti-fire and insulation tube (diameter≥25mm), standard three-core power
extension wire, tether cable (random configuration), M12 expansion screws (included in the
package).
3. Thread the connection wire of the device through the tube before assembly.
4. The power and signal wires should be set separately to easily distinguish strong and weak power.
Please invite professional personnel to complete the wiring. The device must be connected to
the ground.
Below is the outline and dimensions of SBTL8000:
Figure 1-1
1. Prepare the tools for product installation and sort out the auxiliaries according to the packing list.
2. Drill holes after determining the hole positions based on the mounting template as shown in
Figure 2-1. Insert the expansion bolt into the holes accordingly.
Figure 2-1
3. Tighten the nut preliminarily, then connect the master and slave devices with wires.
4. Test the operations of the device after connecting it to the power supply with the temporary
cable. Make sure that the ground wire of AC power is connected to the cabinet of the device.
5. Turn on the air switch to test whether the device is working properly. Wait for 10 seconds for the
turnstile to complete the self-test program. At the same time, check if the indicators work
properly. If everything works fine, you can fasten the ground screw nuts and fix the device. If an
exception occurs, please contact your vendor.
1. After powered on, the LCD screen on the control board will display the default state showing the
current working mode.
2. There are 4 buttons on the control board: UP, DOWN, ENT, and ESC, as shown in Figure 3-1.
UP: to move upwards or increase the value.
DOWN: to move downwards or decrease the value.
ENT: to enter a menu setting item or confirm the current modified value.
ESC: to return to the previous menu or cancel the current operation.
Menus
2. Passing mode
After the gate is opened, it will automatically close if no one passes through within a certain time
duration. The default value is 5 seconds. The value ranges from 2 to 60.
6. Opening speed
7. Closing speed
8. Swiping mode
9. Reset counter
Volume: off
The value ranges from 1 to 16 (default 5).
1 is the minimum value; 16 is the maximum value.
Version: V9.0.0
The mode indicator light does not respond Check that the control panel mode indicator
1
or the indication is incorrect. wiring is correct or that the contact is poor.
The barrier doesn’t close when the opening Check to see if the opening delay time is too
3
delay time is ended. long or whether the IR sensor is covered.
Figure 5-1
8 SBTL8000
Copyright©2019 series
ZKTECO CO.,installation
LTD. All rights guide
reserved.