MDR 60 Spec
MDR 60 Spec
MDR 60 Spec
User’s Manual
■ Features :
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Class I, Div 2 Hazardous Locations T4
LED indicator for power on
DC OK relay contact
No load power consumption<0.75W
100% full load burn-in test
■ GTIN CODE 3 years warranty
MW Search: https://www.meanwell.com/serviceGTIN.aspx Bauar t gepruft
Sicherheit
egel ma ge
od o s
THOMAS SAMUEL
THOMAS SAMUEL
be wac g
SPECIFICATION
ID 2000000000
R33100
UL62368-1 RoHS TPTC004 IS13252 BS EN/EN62368-1 IEC62368-1
35 40 100
5 5 5 5 5
+V +V -V -V
DC OK
DC OK
+
+V ADJ
90
N L
7.5 7.5
Install DIN rail TS35/7.5 or TS35/15
Block Diagram
fosc : 60KHz
DC OK
RECTIFIERS RECTIFIERS +V
EMI POWER
I/P & &
FILTER SWITCHING -V
FILTER FILTER
O.C.P.
FG DETECTION
CIRCUIT
O.L.P. CONTROL
O.V.P.
DC OK Relay Contact
100
100
12V,24V,48V
90
80
80
60 70
50
LOAD (%)
5V
LOAD (%)
60
40
50
20
40
-20 0 10 20 30 45 55 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264