Performance Specifications:
Response Time
Parameter Principle Range Accuracy
(T90)
≤ 50μg/m3: ±5μg/m3
PM1 / PM2.5 / Laser Scattering 0~1000μg/m3 ≤ 10s
> 50μg/m3: ±5% reading
PM10
±(30ppm+3%
CO2 NDIR 0~5000ppm < 60s
of reading)
▪ PM Values of only PM2.5 and PM10 can be displayed on the screen. PM1 shall not be
visible on the screen
1
IAQ6
Air Quality Monitor
UI Interface Description :
Good 0~75
PM2.5
Average 75~115
(μg/m³)
Bad ≥115
Good 0~600
CO2
Average 600~1000
(ppm)
Bad ≥1000
2
IAQ6
Air Quality Monitor
3
IAQ6
Air Quality Monitor
Step 2: Connecting Cable, connect the corresponding cable to the monitor's RS485
interface according to the interface definition, as shown below:
Step 3: Match the two holes in the monitor with the hooks in the wall mount bracket and
slide the monitor down to ensure that the monitor is tightly locked with the bracket.