Design of Tricking Filter
Design of Tricking Filter
th
carCalso be worked out by assuming e value of ydraulic loadin l'e%i
25 million litres per hectare per day [i.e. between ·22 to 44 MI.Jhalda~l sa~
•·. Surface area required '
. Total sewage to be treat~d per day
= Hydraulic loading per day
5
= 5 ML = hectares = x 10,000 m2 ::: 20oo
25 ML/hr 25 25 rn2.
2
The surface area chosen is ,2500 m , which is greater than 2000 sq.
hence safe. ·. . . ni, a~
Hence 2 units each of 40 m dia and 2 m effective depth (i.e. 2.6 1
depth), ~an be adopted. An extra third unit as stand-by :rnayrna~ver,~
constructed. Ans. so
Design of Rotary Distributors .
Rotary distributors, as said earlier, are to be designed for peak flow ,
may be considered as 2.25 times the average flow. Wh1c~ 1