SMART DIFFERENTIAL PRESSURE

TRANSMITTER APR-2000ALW
ü 4…20 mA output signal + HART 5 / HART 7 protocol
(special version: 0…20 mA or 0…5 mA output signal + HART 5 protocol)
ü Display with backlight
ü Safety version SIL2/SIL3
ü Intrinsic safety certificate ATEX, IECEx, FM (USA, Canada)
ü Explosion proof certificate ATEX, IECEx, FM (USA, Canada)
ü Programmable zero range, shift, characteristic and damping ratio with
local panel keys
ü Static pressure limit up to 600bar
ü Accuracy 0,075% (0,05%, 0,04% on request) it
ü Marine certificate – DNV, BV 5 y ears s s u r e lim
up to rranty pre ar
ü Gold plated diaphragms
w a static p to 600b
ü Wetted parts material 316L/Hastelloy C276 u

133 18 132 18 Rating plate


APR-2000ALW/SS
APR-2000ALW
M20×1.5 packing gland

91,5
Æ5…10 cable

40
Four holes

(80 in HS version)
Two holes (M6)
M10(standard)
or 7/16’’UNF

70
1/4NPT
41,3

60

Venting
and draining valves

54* 80
*Other distance on request

Transmitter APR-2000ALW – version with type C process connection


to be mounted together with a valve manifold
Version with process connection rotated 90 °
176

176

15
1/4NPT

SW27 2
G1/2"

94.5

Transmitter APR-2000ALW
Transmitter APR-2000ALW Transmitter APR-2000ALW Version with direct or
Version with GP type process connection. Version with PN type process connection. remote diaphragm seal.

II/ 2
Application and construction
The APR-2000ALW transmitter is applicable to the measurement of differential pressure of gases, vapours and liquids. The active element is a
piezoresistant silicon sensor separated from the medium by separating diaphragms and a specially selected type of manometric fluid. The
special design of the active sensing element ensures that it is able to withstand pressure surges and overloads of up to 250/320/413/700 bar.The
casing is made of aluminium alloy cast or 316SS stainles steel, degree of protection IP66/IP67. The design of the casing enables the use of a
local display, rotation of the display, rotation of the casing by 0–340° relative to the sensor, and a choice of cable direction.

Communication and configuration


The communication standard for data interchange with the The data interchange with the transmitter enables users to:
transmitter is the Hart protocol.
¨ identify the transmitter
Communication with the transmitter is carried out with: ¨ configure the output parameters:
– a KAP-03, KAP-03Ex communicator - measurement units and the values of the start points and end
– some other Hart type communicators(*) points at the measurement range
– a PC using an HART/USB converter and Raport 2 - damping time constant
configuration software. - conversion characteristic (inversion, user's non-linear
(*) .eddl files available on www.aplisens.com. characteristic)
¨ read the currently measured pressure value of the output current
and the percentage output control level
¨ force an output current with a set value
¨ calibrate the transmitter in relation to a model pressure
Installation
The transmitter with P or PN type process connection is not heavy, so can be installed without additional mounting bracket on application. For
fitting in any desired position we recommend an universal Aplisens mounting bracket for 2" pipe (AL mounting bracket, see page IV/ 5). The
version with C type process connections can be fitted directly to a 3- or 5- valve manifold. We recommend factory-mounted transmitters with VM
type valve manifold (page IV/ 2). A transmitter without a valve manifold can be fitted in any position on a 2" pipe or on a wall using the C-2"
mounting bracket (page IV/ 5). When the special process connections are required for the measurement of specific media levels in closed tanks
(e.g. in the sugar and chemical industries) the transmitter is fitted with an Aplisens diaphragm seal. Sets of differential pressure transmitters with
diaphragm seals are described in detail in the further part of the catalogue.

Measuring ranges
No. Nominal measuring range Minimum set range Rangeability Overpressure limit/ static pressure limit
(FSO)
1 0...70 bar (0...7 MPa) 7 bar (700 kPa) 10:1
2 0...16 bar * (0...1,6 MPa) 1,6 bar (160 kPa) 10:1
3 0...2,5 bar (0...250 kPa) 0,2 bar (20 kPa) 12,5:1
4 0...1 bar * (0...100 kPa) 50 mbar (5k Pa) 20:1
C-type: 250 / 320 / 413 bar
5 0...0,25 bar * (0...25 kPa) 10 mbar (1k Pa) 25:1
(250 bar for PED version)
6 -0,5...0,5 bar * (-50...50 kPa) 0,1 bar (10 kPa) 10:1 GP-type: 40 bar (for range no. 1: 70bar)
7 -100…100 mbar * (-10…10 kPa) 10 mbar (1 kPa) 20:1
8 -5...70 mbar * (-0,5...7 kPa) 4 mbar (0,4 kPa) 18:1
9 -25…25 mbar ** (-2,5…2,5 kPa) 2 mbar (0,2 kPa) 25:1
10 -7…7 mbar ** (-700…700 Pa) 1 mbar (0,1 kPa) 14:1
* available also in HS version
** available only in HS version

Technical data
Metrological parameters Electrical parameters
Accuracy £ ±0,075% of the calibrated range Version Power supply
Special version: £ ±0,05% of the calibrated range standard 10...55 VDC
(£ ±0,04%, £ ±0,025% on request) Exia 10,5…30 VDC
IS 11,5…30 VDC
Long term stability £ accuracy for 3 years Exd, XP 13,5…55 VDC
(for the nominal measuring range) or £ 2 x accuracy for 5 years Exia/Exd, IS/XP 11,5…30 VDC / 11,5…55 VDC
HS version: £ accuracy for 10 years Safety, Safety Exd, Safety XP 11,5…36 VDC
Thermal error < ±0,05% (FSO) / 10°C for ranges no. 1 - 9 Safety Exia, Safety IS 11,5…30 VDC
Safety Exia/Exd, Safety IS/XP 11,5…30 VDC / 11,5…36 VDC
< ±0,08% (FSO) / 10°C for ranges no. 10
max. ±0,25% (FSO) in the whole compensation range Output signal 4...20 mA + HART
spec. version for ranges no 1-9:
£ ±0,03% (FSO) / 10°C U sup[V] - 10V
Load resistance (for standard version) R[W] £
max. ±0,1% (FSO) in the whole compensation range 0,0225A

Thermal compensation range -25…80°C Resistance required for communication min. 240 W
Zero shift error for static pressure
0,01% (FSO) / 10 bar for ranges no. 3, 4, 5, 6, 7, 9 Materials
0,03% (FSO) / 10 bar for range no. 8 Wetted parts type GP, PN: SS316L
0,06% (FSO) / 10 bar for ranges no. 1, 2 type C: SS316L (Hastelloy C276 on request)
0,01% (FSO) / 10 bar for ranges no. 2, 8 in HS version Diaphragms SS316L
0,02% (FSO) / 10 bar for range no. 10 (Hastelloy C 276, Tantalum, Au on request)
Zeroing the transmitter in conditions of static pressure can elimi-
Casing Aluminium
nate this error.
Option: SS316
Additional electronic damping 0…60 s Material of window: hardened glass
Error due to supply voltage changes 0,002% (FSO) / V

II/ 3
Operating conditions
Operating temperature range (ambient temp.) -25...85°C
Exia, IS version: -25…80°C
CH-type process connection (rotated 90°)
Exd, XP version: -25…75°C
Medium temperature range -25...120°C
Safety, 600bar version: -25…85°C
PED, 413bar version: -25…100°C
over 120°C – measurement with use an impulse line or dia-
phragm seals

CAUTION: the medium must not be allowed to freeze in the im-


pulse line or close to the process connection of the transmitter

Ordering procedure
Model Code Description
APR-2000 Smart differential pressure transmitter
/ALW……………........………………………………..… With display, output 4-20mA + Hart
Versions /ALW/Safety................................................................ Functional Safety certificate according to PN-EN 61508:2010 parts 1 ÷ 7,
PN-EN 61511-1:2017 + PN-EN 61511-1:2017/A1:2018-03,
PN-EN 62061:2008 + PN-EN 62061:2008/A1:2013-06 + PN-EN 62061:2008/A2:2016-01
/SS………………………………………………… Stainless steel housing
/Exia……………………………………………..... II 1/2G Ex ia IIC T4/T5 Ga/Gb
IECEx Ex ia IIC T4/T5 Ga/Gb
/Exia (Da)…………………………………........... II 1/2G Ex ia IIC T4/T5 Ga/Gb
II 1D Ex ia IIIC T105°C Da
I M1 Ex ia I Ma (version with SS housing)
Ex ia IIC T4/T5 Ga/Gb
IECEx Ex ia IIIC T105°C Da
Ex ia I Ma (version with SS housing)
/IS…………………………………………………. IS Class I, Div 1, Groups A, B, C, D T4
IS Class II, Div 1, Groups E, F, G T5
IS Class III, Div 1, T5
Zone 0 AEx/Ex ia IIC T4 Ga
Zone 20 AEx/Ex ia IIIC T105°C Da
/Exd……………………………………………….. II 1/2G Ex ia/db IIC T6/T5 Ga/Gb
II 1/2D Ex ia/tb IIIC T105°C Da/Db
I M2 Exd ia I Mb (version with SS housing) Packing gland available on
Ex ia/db IIC T6/T5 Ga/Gb request
IECEx Ex ia/tb IIIC T105°C Da/Db
Ex db ia I Mb (version with SS housing)
/Exd (2G)…………………………………………. II 2G Ex ia/db IIC T6/T5 Gb
II 2D Ex ia/tb IIIC T105°C Db Packing gland available on
Certificates, options* Ex ia/db IIC T6/T5 Gb request
IECEx
Ex ia/tb IIIC T105°C Db
/XP………………………………………………... XP Class I, Div 1, Groups A, B, C, D T5
DIP Class II, Div 1, Groups E, F, G T5
Packing gland available on
DIP Class III, Div 1, T5 request
Zone 1 AEx db ia IIC T5 Gb
Zone 21 AEx ia tb IIIC T105°C Db
/XPC……………………………………………… XP Class I, Div 1, Groups B, C, D T5
DIP Class II, Div 1, Groups E, F, G T5
Packing gland available on
DIP Class III, Div 1, T5
request
Zone 1 AEx/Ex db ia IIC T5 Gb
Zone 21 AEx/Ex ia tb IIIC T105°C Db
/Exia(Da)/Exd……………………………………. Dual certification Exia(Da) and Exd
/Exia(Da)/Exd(2G)………………………………. Dual certification Exia(Da) and Exd(2G)
/IS/XP…………………………………………...... Dual certification IS and XP for US
/IS/XPC…………………………………………... Dual certification IS and XPC for US and Canada
/SA………………………………………………… Surge arrester for Exia version
/PED………….....….......................................... PED category I (only process connection type C)
/HS…..……….....…........................................... Ultra stable version (only ranges no. 2, 4÷10)
/0,05% Accuracy £ ±0,05%
/MR...…………....……...............………………..
Marine certificate – DNV, BV
/Tlen…………..............…….....………......…….
For oxygen service (sensor filled with Fluorolube fluid)
/320 bar............….............................................
Static pressure 320 bar, only for C process connection, not available in PED version
/413 bar............….............................................
Static pressure 413 bar, only for C process connection, not available in PED version
/600 bar............….............................................
Static pressure 600 bar, only for C process connection, not available in PED version
* more than one option
Execution on request – please consult availability with manufacturer
is available
/IP67………………………………………………. Protection class IP67
/NACE…………………………………………….. NACE MR-01-75 certificate (only process connection type C)
/Hart 7..…………………………………………… Communication protocol HART in revision 7
See next page

II/ 4
Code Description
Range Min. set range
/0÷70 bar..........................................….. 0÷70 bar (0÷7000 kPa) 7 bar (700 kPa)
/0÷16 bar…............................................ 0÷16 bar (0÷1600 kPa) 1,6 bar (160 kPa)
/0÷2,5 bar...................................…..….. 0÷2,5 bar (0÷250 kP) 0,2 bar (20 kPa)
/0÷1 bar….............................................. 0÷1 bar (0÷100 kPa) 50 mbar (5 kPa)
Nominal measuring ranges /0÷0,25 bar…................................……. 0÷0,25 bar (0÷25 kPa) 10 mbar (1 kPa)
/-0,5÷0,5 bar…............................……… -0,5÷0,5 bar (50÷50 kPa) 0,1 bar (10 kPa)
/-0,1÷0,1 bar…............................……… -0,1÷0,1 bar (-10÷10 kPa) 10 mbar (1 kPa)
/-5÷70 mbar…………………………….. -5÷70 mbar (0,5÷7 kPa) 4 mbar (0,4 kPa)
/-25÷25 mbar......................................... -25÷25 mbar (-2,5÷2,5 kPa) 2 mbar (0,2 kPa)
/-7÷7 mbar……...................................... -7÷7 mbar (-0,7÷0,7 kPa) 1 mbar (0,1 kPa)
Measuring set range /…÷… [required units] Calibrated range in relation to 4mA and 20mA output
/C…....................................... Thread 1/4NPT F on the cover flanges cover flanges. Allows mounting with a valve
manifold. Process connection of cover flange: M10 (option /C(7/16) - 7/16”UNF acc.
Process connections to IEC 61518), wetted parts material: choose below
/CH……………………………. C-type process connection rotated 90°
/GP......................................... Thread G1/2” (male), wetted parts material: SS316L
/PN......................................... Thread 1/4”NPT (female), wetted parts material: SS316L
/code of diaphragm seal……. Diaphragm seal (see chapter of diaphragm seals) mounted on Hi side of transmitter,
Lo side 1/4NPT Female
(without marking)............... Covers material: SS316L / Diaphragms material: SS316L
/(316L/Hast)....................... Covers material: SS316L / Diaphragms material: Hastelloy C276
Material of wetted parts: /(Hast/Hast)........................ Covers material: Hastelloy C276 Cast / Diaphragms material: Hastelloy C276
(diaphragms/covers)
/(316L/Au).......................... Covers material: SS316L / Diaphragms material: Gold plated
(refers only to C, CH process connection)
/(316L/Ta).......................... Covers material: SS316L / Diaphragms material: Tantalum
/(Hast/Ta)........................... Covers material: Hastelloy C276 Cast / Diaphragms material: Tantalum
(without marking)........... FPM Viton (not available for Hast/Hast, Ta/316L and Ta/Hast versions)
Gasket (refers only to C, CH process connection)
/NBR.............................. NBR (not available for Hast/Hast, Ta/316L and Ta/Hast versions)
/PTFE…………………… PTFE
(without marking) Packing gland M20x1,5
Electrical connection
/US............................. Thread 1/2”NPT Female
/C-2”.................. Mounting bracket for 2” pipe (to C process conn.), mat. zinced steel
/C-2”(SS).......... Mounting bracket for 2” pipe (to C process conn.), mat. ss304
/C-2”(SS316).... Mounting bracket for 2” pipe (to C process conn.), mat. ss316
/C-2”B............... Mounting bracket for 2” pipe (to C(7/16) process conn.), mat. zinced steel
/C-2”B(SS)........ Mounting bracket for 2” pipe (to C(7/16) process conn.), mat. ss304
/C-2”B(SS316).. Mounting bracket for 2” pipe (to C(7/16) process conn.), mat. ss316
/FI25………...… Mounting bracket for 1” pipe (to P process conn.), mat. Stainless Steel
Accessories
/RedSpaw GP... Connector to weld impulse pipes dia. 12 and 14 mm, material 15HM(SO) or
SS316(S). Only process connection GP type
/RedSpaw C….. Connector to weld impulse pipes dia. 12 and 14 mm, material 15HM. Only process
connection C type.
Adapter for differential pressure transmitters with C type process connection, output
/Red d/P 1/2’’…
thread 1/2NPT F. Material SS316L
/ST.................... Stainless Steel plate fixed to the housing
/MT................... Stainless Steel Tag plate mounted on wire
Other specification /............... Description of required parameters

Standard display configuration


Exia, Exia(Da)/Exd,
Std. version IS Exd XP Safety
Exia(Da) IS/XP
Backlight on · · ·
Backlight off · · · ·
Other configuration of display has to be marked upon placing order. User has no possibility of switching backlight on/off.