Item of Works
Item of Works
Item of Works
RFC Register
SerialNo Specification Unit Base Rate Qual Rate
Excavation in open area- Earth work excavation in ALL KIND OF SOIL at all
depths , for Leveling & Lowering ,Trimming the ground,for acheving the proposed
1.2 Cum 69.00 75.90
formation and transporting ,stacking the excavated earth at designated places
within the site ,as per the directions of the Engineer Incharge
Excavation in open area- Earth work excavation in HARD ROCK at all depths ,
for Leveling & Lowering ,Trimming the ground,for acheving the proposed
1.3 Cum 550.00 605.00
formation and transporting ,stacking the excavated earth at designated places
within the site ,as per the directions of the Engineer Incharge
Earthwork excavation for foundation of structures upto 3mts by Mechanical means
as per drawing and technical specification, including setting out, providing shoring
strutting and bracing removal of stumps and other deleterious matter, dressing of
1.4 Cum 81.00 89.10
sides and bottoms filling back the excavated earth to the extent required and
utilizing / transporting the remaining earth upto 1.00 km lead, including cost of
labour material and HOM etc., complete. a) All kindl of soil
Earthwork excavation for foundation of structures upto 3mts by Mechanical means
as per drawing and technical specification, including setting out, providing shoring
strutting and bracing removal of stumps and other deleterious matter, dressing of
1.5 Cum 550.00 605.00
sides and bottoms filling back the excavated earth to the extent required and
utilizing / transporting the remaining earth upto 1.00 km lead, including cost of
labour material and HOM etc., complete. a) Hard rock
BACKFILLING: Filling available excavated earth in foundations upto plinth in
layers not exceeding 300 mm in depth. Compacting each deposited layers by
1.6 Cum 115.58 127.13
ramming after watering to achieve 95% proctor density at optimum moisture
content
Construction of embankment with materials deposited from roadway cutting and
excavation from drain and foundation of other structures graded and compacted to
meet requirement of table 300-2 in layers not exceeding 250 mm loose thickness,
spreading, breaking clods removal of roots and other organic materials to the
required line, grade and cross section including watering, spreading by dozer,
1.7 grading by mortor grader and consolidation by vibratory road roller with desired Cum 85.88 94.46
field density not less than 95 % of maximum dry density within a lead of 100m
including all lead & lift , labour charges ,loading & unloading, cost of all
materials, hiring charges & transportation charge of all machineries, curing &
inclusive of all incidental charges Etc complete as per specifications & as directed
by Engineer-in-charge of work
Providing and laying in position plain cement concrete of Mix 1:3:6 with OPC @
220kgs with 20mm and down size size graded granite metal coarse aggregate @
0.69cum and fine aggregate @ 0.56cum, machine mixed concrete laid in layers not
3.1 Cum 3,100.07 3,658.09
exceeding 15cm thick, well compacted in foundation plinth and cills, includingcost
of all materials, labours, HOM, curing complete as per specifications. specification
No KBS 4.1, 4.2
about:blank 1/9
10/31/23, 3:21 PM RFC Register
Providing and laying in position plain cement concrete of Mix 1:2:4 with OPC @
240kgs with 20mm and down size size graded granite metal coarse aggregate @
0.878cum and fine aggregate @ 0.53cum, machine mixed concrete laid in layers
3.2 Cum 3,413.53 4,027.97
not exceeding 15cm thick, well compacted in foundation plinth and cills,
includingcost of all materials, labours, HOM, curing complete as per
specifications. specification No KBS 4.1, 4.2
Providing and laying in position Reinforced cement concrete for all Super
structures of building , Road works, Water works, Irrigation works & super
structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed
graded coarse aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticisers laid in layers, well compacted using needle vibrators.
3.3 0.00 0.00
The cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid
separately)
3.3.1 M20 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Cum 3,926.85 4,633.68
3.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Cum 4,079.97 4,814.37
3.3.3 M30 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Cum 4,285.53 5,056.92
3.3.4 M35 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Cum 4,456.59 5,258.78
3.3.5 M 40 Design Mix Using 20 mm nominal size graded crushed coarseaggregates Cum 4,649.02 5,485.85
Providing and removing centering, shuttering, strutting, propping etc, and removal
5.1 of form work for foundations, footings, bases of columns for mass concrete Sqm 300.00 339.00
including cost of materials, labours complete as per specifications.
Providing and removing centering, shuttering, strutting, propping etc, and removal
of form work for vertical surfaces such as walls at any thickness, including
5.2 Sqm 300.00 339.00
attached pilasters, buttresses, plinth cills and string courses including cost of
materials, labours complete as per specifications.
6 Sub base works 0.00 0.00
about:blank 2/9
10/31/23, 3:21 PM RFC Register
Construction of granular sub base Grading V as sub base and drainage layer by
providing coarse graded crushed stone aggregate of granite/trap/basalt material,
mixing in a mechanical mix plant at OMC, carriage of mixed material to work site,
6.1 Cum 1,687.43 1,873.05
spreading in uniform layers with motor grader on prepared surfaces and
compacting with vibratoty power roller to achieve th 98% proctor density,
complete as per specifications. Clause 401 of Morth V revision.
Providng, laying, spreading and compacting crushed stone aggregate of granite /
trap / basalt to wet mix mackdam specification including pre mixing the materaila
with water at OMC in mechanical mix plant carraige of mixed materials by tipper
6.2 Cum 1,852.43 2,056.20
to site, laying in uniform layers with paver in sub-base/base course on welll
prepared surface and compacting with vibratory roller to achive the desired density
complete as per specification. MORTH specification No 406.
LDPE SHEET: Provinding & laying single layer of LDPE sheet of 200 microns
7.1 Sqm 34.00 37.40
thick approved quality on sub base of FM2 Class flooring(Vapour Barrier).
about:blank 3/9
10/31/23, 3:21 PM RFC Register
NS over the dry shake layer, then worked in the surface with power trowel 4.Start
applying second coat of Concria DECO Dry Shake, approx. 3 kg/m2 immediately
after first coat of dry-shake is troweled with pans. 5.Working Concria Hard NS
into the surface with a bull float to ensure the Concria Trowel Hard is worked
deeply into the dry shake & Cement matrix. 6.Finally, power trowel the surface
with finishing blades. Use plastic blades, pans and hand trowels to avoid trowel
marks. 7.Curing the floor with water for 15 days and covering the floor with a
plastic sheet. (No Curing compound to be applied)
about:blank 4/9
10/31/23, 3:21 PM RFC Register
GYPSUM CEILING: Providing & fixing of Gypsum Ceiling in two levels with GI
channels/gauges including 3 coats of plastic emulsion paint for the following .
Gypsum plain ceiling ( cost to include cut outs for light fitting & supports as
required. A.c grills & 3 coats of painting). Providing & fixing suspended false
ceiling which includes providing and fixing G.l perimeter channels of size 0.55mm
thick having one flange of 20mm and another flange of 30mm and a web of 27mm
along with perimeter ceiling ., screw fixed to brickwall/partition with the help of
nylon sleeves & screws at 600mm centres then suspending G.l intermediate
channels of size 45mm 0.9mm thick with two flages of 15mm each from two soffit
9.1 Sqm 1,002.00 1,102.20
at 1220mm centres with ceiling angle of width 25x 10 x 0.55mm thick fixed to
soffit with G.I. cleat and steel expansion fastners. Ceiling section of 0.55mm
thickness having knurled web of 51.5mm two flanges of 26mm each with lips of
10.5mm are then fixed to the intermediate channel with the help or connecting dips
and in direction perpendicular to the intermediate channel at 457mm centres.
12.5mm tapered edge gypboard (conforming to IS -2095-1982) is the screw fixed
to the ceiling section with 25mm drywall screws at 230mm centres. Screw fixing
is done mechanically either with screw driver or drilling machine with suitable
attachment.
Providing & Fixing Of Partition Frame Work Made Of 2" X 1" G I ( 18Gauge)
Spaced At 2’.0" & Horizontally (1.2Mm Thk). Additional Member Shall Be
Provided At Skirting, Top Band, Grooves & At Places Where Two Different
9.2 Sqm 433.00 476.30
Materials Are Combined. Necessary Supports To The Slab Should Be Taken In
Total Account. Only Clear Height And Width Of The Completed Panel Shall Be
Measured And Paid For Under This Item.
Providing & Fixing Of Partition Cladding With 12Mm Thick India Gypsum Board
With Joint Tape And Finished With Gypsum Powder . To Be Provided All Around
9.3 As Border. Gypsum To Be Finished With One Coat Primer And Two Coat Wall Sqm 581.00 639.10
Care Putty And Two Coat Of Tractor Emulsion Paint (Using Asian Brand For Paint
Item)
9.4 Providing & Fixing Of Panel Door Made Of 32Mm Thick Flush Door Finished Sqm 9,800.00 10,780.00
With Laminate Both Side. The Door Shall Be Partly Glazed With Vision Panel
Made Of 8Mm Clear Glass As Per Design And Detail. Glass Fixed With Teak
Wood Biding All Sides. As Per Design & Detail (Cost To Include Fixed Laminate
Panel Also.( Dorma Fittings): 2- D Handel-12", 4 Ball Bearing Hinges- 5": Dead
about:blank 5/9
10/31/23, 3:21 PM RFC Register
Lock, Door Closure Heavy Duty Double Speed And Door Stopper) Including Door
Frame With 19Mm Plywood And With Laminate Finish
Providing & Fixing Of Bathroom Plastic Door(25Mm)With Including Hardware
9.5 Nos 6,266.00 6,892.60
Fitting & Labour Cost
Providing & Fixing Of Window Sofit Made Out Of 19Mm Plywood Of Size 6" .
9.6 Rmt 682.00 750.20
With 1Mm Laminate Finished
Providing & Fixing Of Softboard Made Of Fabric On 12Mm Ply Backing As Per
9.12 Sqm 2,044.00 2,248.40
Design & Detail. Basic Cost For Fabric 200 Per Meter.
Providing And Fixing Of 6Mm Mirror With 12Mm Ply Backing & Front With
9.13 Sqm 3,464.00 3,810.40
Teak Wood Bidding Including Melamine Polish All Around The Mirror
Providing & Fixing Glass Wool (5Omm Thick.) For Sound Insulation, Density Of
9.14 Sqm 494.00 543.40
The Glass Wool - 24Kg/Cum
Providing And Fixing Of Reception Table Made Of 19Mm P;Y With Linear
9.15 Laminate Inside And Color Laminate Outside And Including With All Hardware Rmt 14,106.00 15,516.60
Item Etc.
Providing And Fixing Of Window With 8Mm Glass Including Laminate Finish
9.16 Sqm 3,174.00 3,491.40
With 12Mm Ply Framing ( Teakwood Beading All Around The 8Mm Glass )
Supply & installation of toilet cubical-Boilo SS series L type Cubicals: Std Overall
Height of cubical 2000mm, overall width - 1000mm, std ground clearance 150mm,
std width of door 600mm, std depth of cubical - 1000mm. Accessories: 1) SS
Finished Anodized Top rail 2) SS Finish anodised U & H channels (All the make
of accessories for the cubicals to be as per the manufactures's specifications a) SS
9.17 Nos 25,688.33 25,688.33
304 coat hook with door stopper option with satin finish b) SS 304 Gavity hinges
c) SS latch cum occupancy indicator - 304 grade or SS privacy thumb turn with
indicator d) SS palm design adjustable foot 304 garde e) SS screw & Inserts - 304
grade f) Rubber Lining for door stopper g) High strength board with high pressure
laminate fixed on both sides h) SS - 316 Adjustable Legs
Supply and Installation of Urinal Partition: providing and fixing of urinal partition
with high strength board with high pressure laminate fixed on both side size of
9.18 Nos 2,717.00 2,717.00
panel should be not more tha 550mmx9000mm, including all necessary fittings
and fixtures as directed by Engineer Incharge.
2Hr Fire Rated Emergency Doors With Vision Panel Size: 1.2M X 2.2M supply &
installation Of Steel Fire Doors Using 100 X 57 X1.6Mm Thick Profile Frame
With 48 Mm Thick Shutter Using 1.0 Mm Thick G.I Sheet, Flush Design
10.1 Nos 29,425.00 32,367.50
Comprising Of Two Outer Sheet Rigidly Connected And Reinforced Inside With
Continues Vertical Stiffeners, Infilling Of Specially Designed Honeycomb
Structure Complete Finished With Powder Coating Of Approved Ral Shade. 3002.
10.2 Double Shutter Metal Doors , Size:2.5M X 2.5M Supply & installation Of General Nos 60,000.00 66,000.00
Purpose Steel Doors Using 100 X 57 X1.2Mm Thick Profile Frame With 45 Mm
about:blank 6/9
10/31/23, 3:21 PM RFC Register
Thick Shutter Using 1.0 Mm Thick G.I Sheet, Flush Design Comprising Of Two
Outer Sheet Rigidly Connected And Reinforced Inside With Continues Vertical
Stiffeners, Infilling Of Specially Designed Honeycomb Structure Complete
Finished With Powder Coating Of Approved Ral Shade. 7035
Four Paneled Metal Doors With Vision Panel Supply & installation Of General
Purpose Steel Doors Using 100 X 57 X1.2Mm Thick Profile Frame With 45 Mm
Thick Shutter Using 1.0 Mm Thick G.I Sheet, Flush Design Comprising Of Two
10.3 Nos 62,000.00 68,200.00
Outer Sheet Rigidly Connected And Reinforced Inside With Continues Vertical
Stiffeners, Infilling Of Specially Designed Honeycomb Structure Complete
Finished With Powder Coating Of Approved Ral Shade. 7035
uPVC WINDOW: Providing and & fixing of uPVC windows made out of multi
chamered uPVC section with TPV gasket having isolated drainage and reinforced
with galvanised iron profiles of 1.8mm thick, sash with reinforcement of 1.5 mm
10.4 thick.Glazing bead for fixing of glass shall have size as per drawing and Sqm 4,808.32 5,289.15
coextruded with gasket.Windows shall be provided with 5mm plain float glass,
with standard hardware and friction stays(hinges)wall thickness of frame and sash
shall be 2-2.2 mm.
Specification for uPVC ventilators with fixed Louvers: Providing & fixing of
louvered ventilators made out of multi chambered UPVC (Matching to RAL-9016)
sections and with minimum TiO2(Tiatnium Dioxide) at 6PHR with TPV(Thermo
plastic Vulcanized) and lead free with gasket- grey colour having isolated drainage
10.5 and reinforced with Galvanized iron Profile through out the ventilator frame. the Sqm 3,350.77 3,685.85
frame having overall size of 30mmx39mm with GI reinforcement of 1mm
thickness. Louver clip in Aluminium (Powder coated in white) will be used on the
frame along with plastic parts for fixing the 4mm pin head glass wall thickness of
frame shall be 2mm. Maximum possible size 1000mmx1000mm
Providing & Fixing The Work Of Ss 304 Hand Rail Vertical Support 40Mm Pipe,
Every 1.2 Meters Span & Top Hand Pipe Will Be 60Mm With 20Mm Intermediate
10.6 Rmt 6,560.00 7,216.00
Rails With Fixing , Handrail 60Mm, Vertical & Horizontal Support -40Mm,
Intermediate Rail -20Mm, Endcap, Base Cap, Joint Elbow
DOCK LEVELLER : Providing and fixing of Maini / Gandhi make dock leveller
10.7 of 9 tons capacity, with platform size 2730 x 2130 mm, including unloading, Nos 245,000.00 269,500.00
labour charges, transportation complete.
Fabrication supplying and erecting M.S. tubular trusses of all spans as per
approved drawing & design with prefabricated steel applications using quality
material and are durable, reliable and corrosion and abrasion resistant. Welding
shall confirm to latest structural welding code. Quality shall be on various
parameters like shape, size, design gauge and polish. The entire trusses is anchored
in RCC column by using 4 nos of M.S. anchor bolts at each support with 10mm
10.8 MT 93,690.00 103,059.00
thick base plate and shoe plate. The work includes cutting, straightening, placing
in position of M.S. pipes and welding wherever necessary and applying one coat of
redoxide primer coat to all the members including cost of all materials, labour
charges, and hire charges of machineries for cutting, welding, grinding and
erection equipments, with all lead and lift, transportation, letc., complete as per
specification
MS DOOR : Providing and fixing of 1mm thick M.S Sheet door with frame and
diagonal braces of size 40x40x6 mm angle iron, 3.15mm thick M.S gusset plate at
10.9 the junctions and corners with handles, stoppers and locking arrangements etc. Sqm 4,114.00 4,114.00
including applying a priming coat, including cost of materials, labours machinery,
transporatation complete.
Providing and fixing M.S. Hand railing for Balcony/staicase etc, with 50mm dia
M.S. hollow pipe of 14gauge, welded to 20mmx20mm M.S. square rod placed
vertically, spaced at 100mm at reqular intervals of 600mm. These vertical rods
laterally tied to 3 horizotal rods spaced at equal interval. These assembly fixed to
concrete by using expansion bolts and weldin the same to reinforcement bars and
10.10 Kg 88.61 88.61
making good the surface. All the joints and sections should be cut to length,
welded and grinded wherever necessary etc, complete. The work includes cost of
all material labour charges for all items of work , hire charges for welding, cutting
and grinding equipment, and electricity charges etc., complete as per specification
and drawing.
ROLLING SHUTTER: Providing and fixing of motorised RS78GS Rolling
Shutter with Compact Gear P.R.C. Make Indirect Drive Operator, Motorised
Sectional Overhead Doors and Support Structure, with curtain made of single
skinned galvalume steel laths with natural finish, Pressed galvalume steel hood
10.11 Nos 133,375.00 133,375.00
and Motor cover with natural finish, CE Certified CRS Compact Gear P.R.C Make
Indirect Drive Operator, One Flashing Light, Three station push button with
deadman control, including labour charges, priming coat, transportation cost
complete. (Rolling Shutter -RS2(3.5m X3m))
10.12 ROLLING SHUTTER: Providing and fixing of motorised RS78GS Rolling Nos 159,896.00 159,896.00
Shutter with Compact Gear P.R.C. Make Indirect Drive Operator, Motorised
Sectional Overhead Doors and Support Structure, with curtain made of single
skinned galvalume steel laths with natural finish, Pressed galvalume steel hood
and Motor cover with natural finish, CE Certified CRS Compact Gear P.R.C Make
about:blank 7/9
10/31/23, 3:21 PM RFC Register
Indirect Drive Operator, One Flashing Light, Three station push button with
deadman control, including labour charges, priming coat, transportation cost
complete. (Rolling Shutter -RS2(3.5m X5m))
ROLLING SHUTTER: Providing and fixing of motorised RS78GS Rolling
Shutter with Compact Gear P.R.C. Make Indirect Drive Operator, Motorised
Sectional Overhead Doors and Support Structure, with curtain made of single
skinned galvalume steel laths with natural finish, Pressed galvalume steel hood
10.13 Nos 180,301.00 180,301.00
and Motor cover with natural finish, CE Certified CRS Compact Gear P.R.C Make
Indirect Drive Operator, One Flashing Light, Three station push button with
deadman control, including labour charges, priming coat, transportation cost
complete. (Rolling Shutter -RS1(4mX5 m))
ALUMINIUM COMPOSITE PANEL: - ACP cladding work - Supply and
installation of aluminium composite panel of approved make and colour for main
10.14 Sqm 3,766.00 3,766.00
door entrance canopy with all neccessry frame work with suitable aluminium
sections, accessories, sealant etc. Complete including provision for lighting etc.
Supply & installation of special lift table capacity-2000kgs, deck length-3000mm,
10.15 deck width-2500mm, SH-425MM, LH-1800MM, RH-2225 MM,PP-7.5 HP Nos 650,000.00 650,000.00
(SCISSOR LIFT)
Design, fabrication, supply and erection of PEB Structures as per the standards and
below details including 1.Supply and installation of anchor bolts and third party
accessories 2.Providing design details one set of handcopy and a set of softcopy.
3.Stability certificate for the building as a whole for statutory need in required
11.1 form. 4.Guarantee/Waranty for the building as a whole for a minimum of 20 years. Sqm 7,759.46 7,759.46
5.Rate Shall include all loading, unloading, transportation, erection, machinaries,
tools, manpower, consumables etc. 6. Erection: to follow safe and standard
procedures during erection, bolt tightening to be made with torque wrench to
suitable presence.
THERMAL INSULATION SHEET: Supplying and Laying of reflective insulation
material shall be made up of high resistance anti corrosive both side pure
aluminium foils with 10mm closed cell non -toxic fibre free PE bubbles in
11.2 between, consists low emissivity 3%(ASTM 1371), Reflectivity 97%(ASTM 408), Sqm 110.00 110.00
Fire retardant(BS Part 6, Part 7), Aluminum foil thickness -12 microns, Roll size
-1.25 x 30 Mtr, temperature Range (- 50 c to 110 c ) . Finished surface area only
considered for measurement.
Providing & fixing of glass wool (50mm thick) ,density of glass wool-24kg/cum
11.3 Sqm 190.00 190.00
(for PEB works only)
GROUTING: Fosroc conbextra GP2 Grout shall be used for grouting below base
11.4 plate of column. The grout shall be high strength grout having a minimum Cum 47,187.65 47,187.65
characteristic compressive strength of min 30 N/mm2 at 28 days.
Providing and constructing dry lean cement concrete mix CC 1:5:10 base with
OPC 25mm and down size graded granite metal coarse aggregate at 0.86 cum and
fine aggrageta @ .58cum over a prepared sub base, coarse and fine aggregate
conforming to IS: 383-2016 aggragete cement ratio not to exceed 15:1 aggregate
13.1 grading after bleading to as per Table 600-1, optimum moisture content to be Cum 3,754.30 3,754.30
deteremined during trial length construction, concrete strength not to be less than
10Mpa at 7days mixed in a batching plant, transported to site, laid with a paver,
compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per
specifications clause 601 of MORTH V revision and IS 456 Table-5
Construction of granular sub base Grading V as sub base and drainage layer by
providing coarse graded crushed stone aggregate of granite/trap/basalt material,
mixing in a mechanical mix plant at OMC, carriage of mixed material to work site,
13.2 Cum 1,761.73 1,761.73
spreading in uniform layers with motor grader on prepared surfaces and
compacting with vibratoty power roller to achieve th 98% proctor density,
complete as per specifications. Clause 401 of Morth V revision.
Providng, laying, spreading and compacting crushed stone aggregate of granite /
trap / basalt to wet mix mackdam specification including pre mixing the materaila
with water at OMC in mechanical mix plant carraige of mixed materials by tipper
13.3 Cum 1,935.18 1,935.18
to site, laying in uniform layers with paver in sub-base/base course on welll
prepared surface and compacting with vibratory roller to achive the desired density
complete as per specification. MORTH specification No 406.
13.4 Construction of cement concrete kerb stone with top and bottom width 115 and Rmt 357.63 357.63
165 mm respectively, 250 mm high in M20 grade PCC on M-10 grade foundation
150mm thick, foundation having 50mm projection beyound kerb stone, kerb stone
laid with kerb laying machine, foundation concrete laid manually, including cost of
all material, labour, HOM, form work, scaffolding & centering complete as per
about:blank 8/9
10/31/23, 3:21 PM RFC Register
specification all complete as per clause 400.8 complete as per specification A using
concrete mixer MORTH specification No 408
Providing and laying heavy duty interlock pavers, using cement and course sand
for manufacture of block of approved size, shape and colour with minimum
compressive strength of 281 kg per sqm over 50mm thick sand bed (average
thickness) and compacting with plate vibrator having 3 tons compaction force
13.5 Sqm 701.28 701.28
thereby forcing part of the sand underneath to come up in between joints, final
compaction of paver surface joints into its final level, including cost of material,
labour and HOM complete as per specifications. a) Hevay duty cobble stones
75mm to 80mm
Control & Construction Joints: Providing and filling grooves with PU (Shore A
Hardness 28 - 45) based sealant of BASF MasterFlex 474 / Sika/ Fosroc or
Equivalent in construction joints & controlled joints top 10 mm of section filled by
13.6 Rmt 106.00 106.00
sealant and below followed backer rod. The rate includes the cost of all ancillary
works as required, as per specifications and as recommended by manufacturer of 4
x 50 mm sectional control joint size & 4 X 15 mm Construction Joints
PLASTIC SHEET: Providing and laying of polythene sheet of 100 microns for
13.7 Sqm 9.50 9.50
curing of concrete floor surface for a minimum curing period of 10 Days.
GARDEN SOIL: Supply and spreading of good Garden Soil without stones/lumps
13.8 Cum 222.33 222.33
etc. (soil within the site)
about:blank 9/9