Tools Required
4 ft. level
Hammer
Hammer drill
Misc. screwdriver bits
Hacksaw
Misc. drill bits, including 4mm (5/32”) & 8mm (5/16”)
6mm (1/4”) masonry bit
11mm (7/16”) wrench
13mm (1/2”) wrench
17mm (11/16”) open end wrench
Chalkline
152mm (6”) shim block
6-lobe driver bit for upper hinge pin
Tape measure

General Notes
M E T A L
The following installation instructions are based on the most common unit arrangement.
CEILING HUNG ELITE Other arrangements will be encountered, i.e. units contained between two walls or
between two freestanding panels.
I N S TA L L AT I O N M A N U A L
For dimensional information, refer to your plan layout and dimensional details. Note
in particular the relationship of the panels to the pilasters (panels do not necessarily
fall on the centerline of the pilaster).
Ceiling hung toilet partitions require an overhead structural member (normally a
channel). This member is supplied, installed, and drilled by others.
Hadrian supplies the stud assemblies but does not install them. Stud assemblies should
be in place prior to application of finished ceiling.
Varying site conditions can affect the installation process. To effect a rigid and level installation, it
is important for installers to be aware of and compensate for uneven floor and wall conditions.

It is the distributor’s responsibility to supply end-users TM

w w w . h a d r i a n - i n c . c o m with maintenance and warranty information.


toilet partitions and lockers
CeilingHungElite 4/23/04 3:57 AM Page 2

Ceiling Stud
Nut & 3/8”
spacer

Pilaster

1 2
Establish Ceiling Stud Locations Fasten Ceiling Studs
Establish front centerline by taking the Drill holes for ceiling studs 25mm (1”) in
overall compartment dimension and from edge of pilaster locations as indicated
deducting 16 mm (5/8”). on layout drawing.
Use final layout drawings to determine locations.

3 4
Erect Panel Place Pilaster Channel
Using your centerline locations, fasten Fasten channel to wall at centerline.
wall channel to wall. The bottom of the Bottom of channel should be 159mm
channel should be 159mm (6 1/4”) from (6 1/4”) from floor.
floor.
Rest panel on 152mm (6”) block and
position in channel, leaving 13mm (1/2”)
clearance between wall and panel. Drill one
hole through top of channel and fasten.
CeilingHungElite 4/23/04 3:57 AM Page 3

5 6
Erect Wall Pilaster Prepare Pilaster For Door
Slide shoe onto pilaster. Position pilaster in Fasten upper and lower hinges to wall
pilaster channel and over ceiling studs. Install pilaster.
ceiling bracket hardware, plumb pilaster, and
Place hinge side filler between hinges,
tighten. Attach pilaster to channel.
pre-drill pilaster with 4mm (5/32”) pilot
holes and install fasteners.

7 8
Fasten Channel To Pilaster Erect Pilaster
Place next pilaster on ceiling studs and mark Slide shoe onto pilaster and position on
center line of panel on the back. Bottom of ceiling studs with channel engaging panel.
channel should be 159mm (6 1/4”) from
Drill one hole through top of channel and
floor. Using the channel as a template,
fasten.
mark drill holes.
Remove pilaster from ceiling studs and
fasten channel.
CeilingHungElite 4/23/04 3:57 AM Page 4

9 10
Prepare Door For Hanging Hang Door
Install female cam in the door. Insert male cam into bottom hinge and
lower door onto it. Install threaded upper
Install latch, and coat hook/bumper.
hinge pin. To set doors at the required
angle, loosen the nut of the male cam
assembly, set door at required angle, and
tighten nut.
Place continuous stop on pilaster, ensuring
the top lines up with the locking bar seam
on top of the door. Pre-drill pilaster
with 4mm (5/32”) pilot holes and install
fasteners.

Contact Hadrian:
11 IN CANADA & AREAS
OTHER THAN USA:
Erect Remaining Compartments
Hadrian Manufacturing Inc.,
Ensure all pilasters are fastened to ceiling 965 Syscon Road,
studs, add all remaining fasteners and Burlington, ON L7L 5S3
tel: 905-333-0300
repeat steps 3-11 (as necessary) for all fax: 905-333-1841
remaining compartments. CAN toll free fax: 1-888-817-7701
Note: Hadrian recommends installing one IN THE USA:
compartment (including door) at a time. Hadrian Inc.,
7420 Clover Ave.,
Mentor, OH 44060
tel: 440-942-9118
fax: 440-942-9618
USA toll free fax: 1-800-536-1469

IN EUROPE:
Hadrian Manufacturing Inc.
Optional Item Unit 14 Howard Court
Nerston Industrial Estate
Continuous Hinge East Kilbride, Scotland G74 4QZ
Replaces conventional hinge and hinge tel: 01355-222270
filler fax: 01355-222213

Registered in the UK: BR7194 • Head Office registered in the


Province of Ontario, Canada. Ontario Corporation Number:
1456606