Manual DMR21
Manual DMR21
AS
Y
CONTENTS
Installation Guide..........................................................................2
Modules. .......................................................................................4
Camera Module.........................................................................4
CONFIGURATIONS......................................................................19
9 0 * # 9 0 * #
A B A B
DESCRIPTION TERMINALS
POW
GND
GND
GND
CTR
DAT
STR
CLK
12V
VIO
design with a flexibility to combine modules.
C2
C1
ON DIP
SET
For example,the video entry module can be assembled with card JP-LK CN/KMB CN/T-COIL
1 2 3 4 5 6
reader module and/or with keypad module.
WG1
WG0
GND
12V
GND
GND
GND
RST
5DA
RX3
RX1
5CL
TX3
TX1
12V
INT
CN-LK
Additional combinations are available: TFT Screen Module with L1 L2
CN/FUN CN/WGN
EB+
EB-
NO
LK+
LK-
+12V
Proximity Reader Module or Keypade Module. Calling to apartments
will be performed by Name List visible on the screen
A B
1 2 3 4 5 6
Connection port
L1 L2
Status Indicator
ID Card Window • Bus(L1,L2): Non-polarity bus line, connect to power supply
316 mm
RF CARD
Nameplate
Call button
Screw hole
133 mm
PLACE NAMEPLATE
Calo
vid
Da
Standard mounting
A B C D
DBC4A
Code=30 Code=29
Cut a hole and install the wall box Connect and plug bus line connector with cable
Code=8 Code=7
3 4 Impedance
switch
OFF ON
A B C D
DBC4A
Code=6 Code=5
Code=4 Code=3
Impedance OFF ON
A B C D
DBC4A
Code=2 Code=1
PC6
BUS(IM) BUS(DS)
Cut a hole and install the wall box Connect and plug bus line connector with cable
3 4 RF CARD
Bit-3 is for single or double row button door station selection. If the Cut off the line Cut off the line
- -
door station is a double row button, such as DMR21-D8, set this bit to +
+12V
+
+12V
+ LK - (GND)
0. For single row button door station,set to 1.
LK - (GND)
LK+(COM) + LK+(COM)
N.O.
- N.O.
EB- - EB-
EB+
Exit button EB+
Bit-4 is for button code selection. if use the default codes for each 1 2 3
Exit button
Take off the Jumper 1 2 3
button of the door station, set to 0. If use the programmed codes, set JP_LK Take off the Jumper
JP_LK
to 1.(the code for each button can be programmed by software, detail
information refer to DT system technical guide)
Bit-5 is for unlocking time quick setting. 0 is the default setting,and the
default time is 1 second. If set to 1,the unlock time is 5 seconds(the
unlock time can be modified by door station or software) SPECIFICATIONS
Bit-6 is for activating the key A and key B. Normally key A and key B
is not activated(about the functions of key A and key B,please refer to
DT system technical guide ),Just when it set to 1,the key A and key B
is activated.
1. The door lock is limited to 12Vdc, and holding current must be less
than 250mA when using internal power supply mode
12V 300mA
+12V
- - +12V
LK -
LK+ LK -
+ LK+
N.O.
12V 300mA EB- + N.O.
EB+ EB-
Exit button EB+
1 2 3 Exit button
Jumper position in 2-3 1 2 3
JP_LK Jumper position in 1-2
JP_LK
Invisible key B
Invisible key A
Status indicator
Talk indicator
• Tune Volume Setting
Unlock indicator
When the door station with Camera Module is standby:
(3)Press B to exit
2. Settings via touch button If TFT Module is connected, the current Volume will be displayed on
screen
Please know that the DIP6 switch must be set to ON while the others
are set to OFF to carry on the following settings.
(1)Press Key A, the Unlock indicator turns on with the warning sound
of BP+, BP;
• Talk Volume Setting
(2)Press Key A again to set the Unlocking Mode to Normally Open (1)During conversation, press and hold Key B for 3 seconds to
or Normally Closed. (Normally Open: the Status indicator blinks enter the Talk Volume Setting. The Talk indicator turns on with the
ones with the warning sound of BP+; Normally Closed:the Status warning sound of BP+,BP
indicator blinks twice with the warning sound of BP+, BP)
(2)Press Key A to increase/decrease volume
If TFT Module is connected, the info will be displayed on screen
(3)Press Key B to exit
The counting of Unlocking Time is the times that Status indicator When in standby mode, short out the Exit Button Port(EB+,EB-),
blinks (the units is second). For example,the Status indicator blinks then continuously toggle the DIP-6 switch for 4 times with a warning
for four times,that means the unlocking time is 4 seconds sound of BP+, and the three Indicators will blink at the same time,
that means the Restore Factory Setting is in progress; If the three
Indicators turn off with a warning sound of BP+,it means the Restore
Factory Setting is finished
KEYPAD MODULE
Interference resistant
• Password Unlocking Valid keys:0 ~ 5 2 09
grade settings
Input password +”#” to unlock the door. SPK Adjustment Valid keys:0~9 5 11
1 ~ 12 digits
• Parameters Setting Setting the code
Number of codes:40 - 20~59
for user group1
This section explains the settings of each function, please refer to the
Valid keys:0~9
tables 1 ~ 12 digits
Setting the code for
Number of codes:40 - 60~99
About the setting mode: user group2
Valid keys:0~9
Input the master code to switch to the setting mode, and input the cor-
responding setting code to perform the settings for the function you
want. After settings have been made, input the following setting codes
to continue the setting operation. Press " " to exit the setting mode
1.Reset all settings 2.Setting the master code 3.Setting the key 4.Setting the
(Default 1234) illumination time unlock time
(Default 10s) (Default 1s)
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
00+# 01+# 02+# 03+#
Inputting of code Inputting of new master code Inputting of code (ex.: 10) Inputting of code (ex.: 09)
(ex.: 4321)(1~12 digits) range:00 or 10~99 range:01~99
1234+# 4321+# 10+# 09+#
- When the “
* cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode
- When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode Beep, Beep+
- All settings will restore to their - The master code is allowed 1~12 - If the key illumination time is set - The unlock time can be set on
default value. digits. The same code cannot be to 00,the key illumination will light both monitor and door station,
and the valid value is the number
- When power on or activate set for both the user code and the up all the time when power on. you set last
the reset all setting item,the master code. It is recommended - If the key illumination time is set to
keypad checking will carry out, that you change the default master 10~99,the key illumination will light
during this time,the key code up for 10~99 seconds.At this mode,
illumination will blink and the the key illumination lights off in
touching operation is forbidden, standby mode, touching any digital
after finish checking,the key key can illuminate,but this is the
illumination will stop blinking invalid digit.
and sent out a long sound of beep
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
04+# 05+# 06+# 07+#
- When the “
* cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
- When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode. Beep, Beep+
- The unlock mode can be set on - When the operation tone is - Cancel all the passwords except - When the item is set to 0,press
both monitor and door station, set to 0,pressing the digital the master code. the button to cancel the input,
*
and the valid value is the number keypad will sent out a sound - Restore the master code to and press the # button to confirm
you set last of beep. default value(1,2,3,4) the input.
- When the operation tone is - When the item is set to 1,press
set to 1,pressing the digital the # button to cancel the input,
keypad will blink one time. and press the * button to confirm
the input .
9. Call tone setting 10.Interference resistant 11.SPK volume adjust 12.Night light level
(Default enable) grade setting setting setting
(Default 2) (Default:4) (Default 4)
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
08+# 09+# 11+# 13+#
0/1
Inputting of code (ex.: 1) Inputting of code (ex.: 3) Inputting of code (ex.: 5) Inputting of code (ex.: 3)
range:0(enable)/1:(disable) range:0~5 range:0~9 range:0~5
1+# 3+# 5+# 3+#
- When the “
* cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
- When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode. Beep, Beep+
- If the item is set to 0,the unit will - The larger you set the - Unlock via password is still - Night Light Level:0~5. -
respond a call tone when pressing interference resistant grade, available even when the door The higher the number, the
the “CALL” button. the stronger it will be,but the station is talking state. brighter the lights
- If set to 1, the unit will have no sensitivity of the keypad will - When door station is talking,
respons when pressing the be more lower. you can enter the Master code
“CALL” button - The interference resistant (the LED turns white upon that)
grade setting also will activate to activate the volume adjusting
the keypad checking function:
Speaker adjustment: 3 (up),
6 (down)
16.Setting the code 17.Setting the code 18.Setting the code 19.Setting the code
forTemporary1 forTemporary2 for user group1 for user group2
20~59 60~99
Input the setting code. Input the setting code. Input the setting code. Input the setting code.
(ex.:21) (ex.:60)
18+# 19+# 21+# 60+#
Inputting of code (ex.: 1006) Inputting of code (ex.: 2011) Inputting of code (ex.: 2011) Inputting of code (ex.: 2012)
1~12 digits 1~12 digits 1~12 digits 1~12 digits
1006+# 2010+# 2011+# 2012+#
- When the “
* cancel” key is pressed, the indicator will show its standby color, the buzzer beeps, and the system
exits the setting mode.
- When there isn’t any operation in 10s, the buzzer beeps, and the system exits the setting mode. Beep, Beep+
- When input the correct temporary password to release the door, - The user code group1 is used to release the first lock,and the user
the system will clear the temporary password after 60 seconds code group2 is used to release the second lock (the second lock
automatically.But you should know that the password is valid within need external device to support).
60 seconds after inputing the correct temporary password - The user code group1 and user code code group2 can contain 40
- The temporary1 is used to release the first lock,and the temporary group passwords
2 is used to release the second lock(the second lock need external - If the password length exceeds 12 digits, the system will sent out
device to support). the sound of “beep,beep,beep,beep”,and the digitals you input
- If the password length exceeds 12 digits, the system will sent out before will be cleared at the same time.
the sound of “beep,beep,beep,beep”,and the digitals you input before - The user code can not be set the same as the master code and
will be cleared at the same time. temporary code.
- The temporary code can not be set the same as the master code
and user code.
• Calling Display
TFT DISPLAY MODULE
This is the user interface of calling process. (Know that if the name
list is created, the resident’s name will be showed on screen)
1. Parts and functions
Press * (Keypad Module) to cancel the call.
Mounting
screw
Touch sensor
button
• Conversation
3. Functions
• Standby
• Keypad operation
iii) When input admin code,a Setting Code will be asked on TFT CARD READER MODULE
screen.
Mounting
screw
Swiping card
area
LED indicator
• Combination with ID module
2. Features
• Up to 320 user cards can be registered by door station
• Easy management with indicators and sound hints
• Two Master Cards are supplied, one MASTER CARD ADD
and one MASTER CARD DELETE
• The distance of card reading is from 3 to 5 cm
• The Master Cards are necessary when you add or delete user
cards. Please keep them safe for future use
It is possible to create new Master Cards, the old ones are invalid
This is the user interface of adding card, please know that the user automatically
interface of delete card or initialization is similar as the following pic-
ture shows.
3. Card Operation
Power on and short out EB+,EB- , a sound of “BP+” will be sent out,
and the Unlock indicator will turn on
Toggle DIP4 switch for four times, a sound of “BP+,BP” will be sent
out , the Talk indicator and the Unlock indicator will turn on
Show the ADD CARD, a sound of “BP+” will be sent out, the Unlock
indicator is turned on.
Show the DELETE CARD, a sound of “BP+” will be sent out, and all
indicators will be turned off. After 10 seconds, it will exit the Master
Card Setting automatically
Power on and short out EB+,EB- , a sound of “BP+” will be sent out, In standby mode, show the MASTER CARD DELETE, it will sound
and the Unlock indicator will turn on “BP+,BP”, and the Unlock indicator will turn on
i) Add User Card Show the MASTER CARD ADD, it will sound “BP+,BP”, and the Talk
indicator and the Unlock indicator will turn on
In standby mode, show the MASTER CARD ADD, it will sound
“BP+,BP”, the Talk indicator will turn on
Show the MASTER CARD ADD, it will sound “BP”, the Talk indicator
Input the room number you need to set (0 is default). Show User and the Unlock indicator will blink, and after 10 seconds, it will
Cards, it will sound “BP+”, and the Talk indicator blinks ones. You return to standby mode
can continuously show User Cards
i) By PC
ii) By SD Card
Show the MASTER CARD ADD to exit out Add User Card Setting,
it will sound “BP,BP+”, and all indicators are turned off. (without any
operation for 10 seconds, it will return to standby mode)
4. Combination
1234
56 78
9 0 * #
A B
In Delete Card Mode :
--Delete by room number: Input the room code, it will sound “BP+”,
and the Unlock indicator blinks one time,all associated cards will be
RF CARD
deleted..
--Delete by User Card: Show the User Cards which you need to
delete. It will sound “BP+”, and he Unlock indicator blinks one time.
(You can continuously show user cards that you need to delete)
Show the MASTER CARD DELETE to exit out Delete Card Mode. The informations will be displayed on screen when some operations
It will sound “BP,BP+”, and all indicators are turned off. (without any are carried on, such as Master Card Setting, Add User Card and
operation for 10 seconds, it will return to standby mode) Delete User Card etc.
For example,swipe the user card, the info of “Door Open” will be dis-
played on screen.
Mounting
screw
Call button
Name plate
Mounting
screw
1) Master Card Setting(Reserve)
Name plate
2. Call codes
* Examples:
ON
09 10
11 12
13 14
15 16
01 02 17 18
03 04 RF CARD 19 20
05 06 21 22
07 08 23 24
01 02 09 10 01 02 25 26
03 04 11 12 03 04 27 28
05 06 13 14 05 06 29 30
07 08 15 16 07 08 31 32
ON
• DIP3 switch set Off
1 2 3 4 5 6
10
12
14
16
02 18
RF CARD 04 RF CARD 20
06 22
08 24
02 10 02 26
04 12 04 28
06 14 06 30
08 16 08 32
ON
05
06
07
08
01 09
RF CARD 02 RF CARD 10
03 11
04 12
01 05 01 13
02 06 02 14
03 07 03 15
04 08 04 16
3. Address description
NO. Functions
01 Call apartment 01
02 Call apartment 02
03 Call apartment 03
04 Call apartment 04
05 Call apartment 05
06 Call apartment 06
07 Call apartment 07
08 Call apartment 08
1 2
• Video entry module
INPUT
1 2 3 4 5
OUTPUT
3
6 7 8
INPUT
OUTPUT
CONNECTIONS
• DMR21/D16 • DMR21/T4/D8
CN/KMB
CN/KMB
CN/FUN
INPUT
INPUT
OUTPUT
OUTPUT
INPUT
INPUT
OUTPUT
• DMR21/ID/S4 • DMR21/ID/KP
CN/KMB
INPUT INPUT
OUTPUT OUTPUT
INPUT
INPUT
1 2 3
4
RF CARD 7 8
5 6
9 * #
0
A B OUTPUT
RF CARD
• DMR21/S8+F3
INPUT
CN/KMB
CN/FUN CN/WGN
OUTPUT
INPUT
INPUT
OUTPUT
OUTPUT
INPUT
INPUT
1 2 3 4
5 6 7 8
9 0 * # OUTPUT
A B OUTPUT
RF CARD
• DMR21/ID/KP
INPUT
CN/KMB
CN/WGN
OUTPUT
INPUT
INPUT
OUTPUT OUTPUT
INPUT
INPUT
RF CARD
OUTPUT
OUTPUT
ii) Open the Namelist.txt file, and input 5 [ ] symbols. Each [ ] symbol
has its meaning, see the following picture.
Description:
Name: It will be displayed on TFT module. i) Press touch sensor button to show the name list
Definition:
[001][Alan_1][08][00][01]
Press the first button, it would call the monitor 01 in BDU 1, and it is • Calling By Keypad Module
displayed Alan_1 on TFT module.
Input the Aprt number on keypad (with keypad module) and press
touch sensor button to call the corresponding monitor
3.Namelist Update:
2. Copy the Update DMR21.bin file to SD card by computer. 2. Copy the Update Ring.bin file to SD card by computer.
i) Power on the DMR21, and set DIP6 switch to ON, as the following i) Power on the DMR21, and set DIP6 switch to ON, as the following
picture shows: picture shows:
DIP6=ON DIP6=ON
ON ON
1 2 3 4 5 6 1 2 3 4 5 6
CN/KMB CN/KMB
CN/WGN CN/WGN
INPUT INPUT
iii) A long warning sound of “BP+” will be sent out, and the Status
indicator is turned on.
iii) A long warning sound of “BP+” will be sent out, and the Talk indi-
cator is turned on.
iiii) After 20 seconds, a long sound of “BP+” will be sent out, and the
Talk indicator is turned off, It means Tone update is finished.
iiii) After 20 seconds, a long sound of “BP+” will be sent out, and all
indicators are turned off.It means Software update is finished.
NAMELIST UPDATE
• Update by SD card
1. Format SD card
3.Update namelist:
i) Power on the DMR21, and set DIP6 switch to ON, as the following
picture shows:
DIP6=ON
ON
1 2 3 4 5 6
CN/KMB
CN/WGN
INPUT
iii) A long warning sound of “BP+” will be sent out, and the Talk indi-
cator is turned on.
iiii) After 20 seconds, a long sound of “BP+” will be sent out, and the
Talk indicator is turned off, It means Namelist update is finished.