BOLLARD STRUCTURAL DESIGN

POWELL BUS BASE


Portland, OR

June
March27,
7, 2019
2019

Prepared By:

Alejandro Virgen, EIT


Checked by:

Alison Wyatt, PE

6/30/20
CAST IN PLACE ANCHORS- EMBEDDEDED

FILL HSS WITH


CONCRETE AND DOME
TOP
20 in, typ

12 KIPS

2 in, typ

HSS 8X0.25 Base Plate


PLAN VIEW
36 in

PL 20in x 20in 1in

1/4" FILLET 8" Concrete Pavement


WELD, TYP (4) 5/8" Heavy Hex
Head Anchor Bolt, Embed
6 inches.
1 in

6 in
1 in
2 in

REINFCEMENT
PER PLAN
THICKENED SLAB
www.hilti.us Profis Anchor 2.8.0
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: AWS D1.1 GR. B 5/8
Effective embedment depth: hef = 6.000 in.
Material:
Proof: Design method ACI 318-08 / CIP
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in.
Anchor plate: lx x ly x t = 20.000 in. x 20.000 in. x 0.500 in.; (Recommended plate thickness: not calculated
Profile: no profile
Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 10.000 in.
Reinforcement: tension: condition B, shear: condition B;
edge reinforcement: none or < No. 4 bar
Seismic loads (cat. C, D, E, or F) no

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [in.] & Loading [lb, in.lb]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads 3 4

Anchor reactions [lb]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 12,587 3,000 -3,000 0
2 0 3,000 -3,000 0 x
Tension Compression
3 12,587 3,000 -3,000 0
4 0 3,000 -3,000 0

max. concrete compressive strain: 0.23 [‰]


max. concrete compressive stress: 1,000 [psi]
resulting tension force in (x/y)=(-8.000/0.000): 25,174 [lb]
1 2
resulting compression force in (x/y)=(9.161/0.000): 25,174 [lb]

Anchor forces are calculated based on the assumption of a rigid baseplate.

3 Tension load
Load Nua [lb] Capacity f Nn [lb] Utilization bN = Nua/f Nn Status
Steel Strength* 12,587 14,966 85 OK
Pullout Strength* 12,587 20,608 62 OK
Concrete Breakout Strength** 25,174 29,497 86 OK
Concrete Side-Face Blowout, direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


Nsa = Ase,N futa ACI 318-08 Eq. (D-3)
f Nsa ≥ Nua ACI 318-08 Eq. (D-1)

Variables
Ase,N [in.2] futa [psi]
0.31 65,000
Calculations
Nsa [lb]
19,955
Results
Nsa [lb] f steel f Nsa [lb] Nua [lb]
19,955 0.750 14,966 12,587

3.2 Pullout Strength


NpN = y c,p Np ACI 318-08 Eq. (D-14)
Np = 8 Abrg f'c ACI 318-08 Eq. (D-15)
f NpN ≥ Nua ACI 318-08 Eq. (D-1)

Variables
y c,p Abrg [in.2] f'c [psi]
1.000 0.92 4,000
Calculations
Np [lb]
29,440
Results
Npn [lb] f concrete f Npn [lb] Nua [lb]
29,440 0.700 20,608 12,587

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

3.3 Concrete Breakout Strength

Ncbg = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nb ACI 318-08 Eq. (D-5)
f Ncbg ≥ Nua ACI 318-08 Eq. (D-1)
ANc see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b)
ANc0 = 9 h2ef ACI 318-08 Eq. (D-6)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-08 Eq. (D-9)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-08 Eq. (D-11)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-08 Eq. (D-13)
1.5
Nb = kc l √fc hef
'
ACI 318-08 Eq. (D-7)

Variables
hef [in.] ec1,N [in.] ec2,N [in.] ca,min [in.] y c,N
6.000 0.000 0.000 ∞ 1.000

cac [in.] kc l f'c [psi]


0.000 24 1 4,000

Calculations
ANc [in.2] ANc0 [in.2] y ec1,N y ec2,N y ed,N y cp,N Nb [lb]
612.00 324.00 1.000 1.000 1.000 1.000 22,308
Results
Ncbg [lb] f concrete f Ncbg [lb] Nua [lb]
42,138 0.700 29,497 25,174

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

4 Shear load
Load Vua [lb] Capacity f Vn [lb] Utilization bV = Vua/f Vn Status
Steel Strength* 3,000 12,971 24 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 12,000 111,432 11 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength


Vsa = Ase,V futa ACI 318-08 Eq. (D-19)
f Vsteel ≥ Vua ACI 318-08 Eq. (D-2)

Variables
Ase,V [in.2] futa [psi]
0.31 65,000
Calculations
Vsa [lb]
19,955
Results
Vsa [lb] f steel f Vsa [lb] Vua [lb]
19,955 0.650 12,971 3,000

4.2 Pryout Strength

Vcpg = kcp [(AA ) y


Nc
Nc0
ec,N ]
y ed,N y c,N y cp,N Nb ACI 318-08 Eq. (D-31)
f Vcpg ≥ Vua ACI 318-08 Eq. (D-2)
ANc see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b)
ANc0 = 9 h2ef ACI 318-08 Eq. (D-6)

( )
1
y ec,N = 2 e'N ≤ 1.0 ACI 318-08 Eq. (D-9)
1+
3 hef
y ed,N = 0.7 + 0.3 (
ca,min
1.5hef )
≤ 1.0 ACI 318-08 Eq. (D-11)

y cp,N = MAX (
ca,min 1.5hef
cac
,
cac )
≤ 1.0 ACI 318-08 Eq. (D-13)
1.5
Nb = kc l √fc hef
'
ACI 318-08 Eq. (D-7)

Variables
kcp hef [in.] ec1,N [in.] ec2,N [in.] ca,min [in.]
2 6.000 0.000 0.000 ∞

y c,N cac [in.] kc l f'c [psi]


1.000 - 24 1 4,000

Calculations
ANc [in.2] ANc0 [in.2] y ec1,N y ec2,N y ed,N y cp,N Nb [lb]
1,156.00 324.00 1.000 1.000 1.000 1.000 22,308
Results
Vcpg [lb] f concrete f Vcpg [lb] Vua [lb]
159,188 0.700 111,432 12,000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

5 Combined tension and shear loads


bN bV z Utilization bN,V [%] Status
0.853 0.231 5/3 86 OK
bNV = bzN + bzV <= 1

6 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout
Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength. Refer to your local standard.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant
standard!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

7 Installation data
Anchor plate, steel: - Anchor type and diameter: AWS D1.1 GR. B 5/8
Profile: no profile Installation torque: -
Hole diameter in the fixture: df = 0.688 in. Hole diameter in the base material: - in.
Plate thickness (input): 0.500 in. Hole depth in the base material: 6.000 in.
Recommended plate thickness: not calculated Minimum thickness of the base material: 6.813 in.

10.000 10.000

2.000
3 4

10.000
16.000
x

10.000

1 2
2.000

2.000 16.000 2.000

Coordinates Anchor in.


Anchor x y c-x c+x c-y c+y
1 -8.000 -8.000 - - - -
2 8.000 -8.000 - - - -
3 -8.000 8.000 - - - -
4 8.000 8.000 - - - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.8.0
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 3/20/2019
E-Mail:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like