Roof Framing Plan: North Magnetic
Roof Framing Plan: North Magnetic
Roof Framing Plan: North Magnetic
NOTES:
- DIMENSIONS ARE IN MILLIMETERS AND ELEVATION LEVELS ARE IN METERS.
M NOR
- FOR GENERAL NOTES & ABBREVIATIONS REFER TO G-S001
AG TH
01 02 03 04 05 06 07 08 09 10 - FOR GENERAL DETAILS REF. TO G-S002 TO G-S005.
NE
B04 B04 B04 B04 B04 B04 B04 B04 B04 B04 - ±0.00 F.F.L = 67.25 SITE SURVEY LEVEL
TIC
- MINIMUM COVER FOR ABOVE GROUND:
71400 - FOR COLUMNS...........3.0 cm.
8400 4200 8400 8400 8400 8400 8400 8400 8400
- FOR BEAMS................3.0 cm.
N - FOR SLABS.................2.5 cm.
- MINIMUM CONCRETE STRENGTH IS AS THE FOLLOWING:
- Fcu = 40 MPa (FOR BEAMS & SLABS)
- Fcu = 40 MPa (FOR COLUMNS & SHEAR WALLS)
- SIESMIC ADD. RFT ARE INDICATED ON PLANS, AND TO BE ADDED TO THE OTHER
NON-PT RFT RESULTING FROM PT DESIGN.
- ALL MEP WORK TO BE COORDINATED WITH STRUCTURAL ELEMENTS BEFORE
STARTING WORK.
6 6
B04-S301 B04-S301
LEGEND :
D J D DEPRESSED SLAB
B04
B6(250x800) B5(250x800) B5(250x800) B5(250x800) B5(250x800) B5(250x800) B5(250x800) B5(250x800) B5(250x800)
LIGHTWEIGHT CONCRETE
B6(250x800)
B6(250x800)
MACHINE PAD
B5(250x800)
B5(250x800)
CONCRETE STRIP TO SUPPORT STEEL BEAMS FOR HVAC MACHINES
B6(250x800)
B4(250x800)
B5(250x800)
B6(250x800)
UPSTAND
4868
B6(250x800) Ø12@300 ADD. TOP
8400
1149 L=3000
700
Ø12@300 ADD. TOP
200
Ø12@300 ADD. TOP 700
B16(250x1010)
B16(250x1010)
S1 S1 L=3000 Ø12@300 ADD. TOP
L=3000 1600
200
L=3000
6300
4500
4500
EL. 20.45 EL. 20.45
6300
400 900
3301
T.O.S.S. T.O.S.S. 1600 2242
1300
900
400
495 900
1450 500
1950
2900
B6(250x800)
950 500
375
B5(250x800)
H
500
1600
1450
1450
400
B04
950
2462
B6(250x800)
3250
500 500
500 EL. 19.70 500 500
2562
T.O.S.S.
700
950
1375
B6(250x800)
1450
1450
1450
1450
1450
G
500
500
B04
11 900
4361 B04-S301
900
PC3
3550
B5(250x800)
B4(250x800)
PC3
200
B5(250x800)
B2(250x875)
200 THK. 800 1600
B6(250x800)
B6(250x800)
B6(250x800)
B7(250x800)
2400
6300
8400
1700
L=3000
200
6300
Ø12@300 ADD. TOP 400 1600
UPSTAND 1500 mm
B6(250x800)
6 L=3000
B04-S301 2400 3125
1400
7
C B6(250x800) B5(250x800) B5(250x800) B5(250x800) B6(250x800)
B04-S301
C
1450 PC3 B6(250x800) PC3 B6(250x800)
B6(250x800)
F
500
500
B04 950
1450 6
B04-S301
B5(250x800)
260 mm THK.
POST TENSION SLAB
8400
B5(250x800)
E ISSUED FOR CONSTRUCTION AUG. 2022
1600
M NOR
AG TH
NE
TIC
63000
N
1600
B5(250x800)
B5(250x800)
200 B04
8400
DN
DN
1450 1450
B6(250x800) B6(250x800)
D
500
500
B04 CLIENT:
B B
PROJECT NAME:
260 mm THK.
B5(250x800)
B5(250x800)
02 03
B04 B04
6 EL. 19.70
B04-S301
T.O.S.S.
Ø12@300 ADD. TOP
L=3000
700
L=3000 G
400
700
3500
B04
400 6 ADMINISTRATION BUILDING (B04)
B04-S301
B4(250x800)
Ø12@300 ADD. TOP
B6(250x800)
DESIGNER:
B5(250x800)
8400
8400
E-mail: [email protected]
B4(250x800)
B4(250x800)
URL: www.whitespcae.ae
S2
INTERIOR DESIGN CONSULTANT:
EL. 22.75 Gensler architecture, design, and planning firm
T.O.S.S. Alserkal Avenue, Warehouse 12, Al Quoz 1
PO Box: 58527 Dubai, UAE
1450 UPSTAND 1500 mm Tel.: +971 (0)4 356 1300
B5(250x800) B6(250x800)
B
1400
URL: https://www.gensler.com/
500
500
B5(250x800)
CONSULTANT:
8400
A B5(250x800) B5(250x800)
A
B5(250x800)
1 2 3 4 5 20220829