SERVICE MANUAL

36
SATELLITE SPEED LOG

11
27 GS-100
02
Model
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly
prohibited to reproduce the document in whole or in part without prior written permission of
FURUNO.
36
11
27
02
24

The paper used in this manual


is elemental chlorine free.
20
an
m

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
jk

Nishinomiya, 662-8580, JAPAN


sl

All rights reserved. Printed in Japan A : SEP . 2017


B : MAR . 23, 2018
Pub. No. SME-72790-B
GS-100
No. : FQ7-2017-006
Date: 2017-09
Information APPROVED BY
Issued by: FURUNO ELECTRIC CO., LTD
SERVICE MANAGEMENT & COMMANDING DEPARTMENT WRITTEN BY

Addenda No. 001 to GS-100 Service Manual Pub. No. SME-72790 ①

SONAR
FNR
Model GS-100 FNZ

Change to Cable Assembly


Incorporating Termination Resisters ②

36
E/S
FCV
[Urgency]

11
When symptom occurs / At installation

27
The installation part: CP20-0350 T-connector of the antenna unit is changed to a cable
assembly incorporating termination resisters in order for the improvement of the installation RADAR
performance.
02
New: Cable assembly incorporating
Old: T-connector
termination resisters
24

NAV
20
an

SSB
m
jk


sl

Note) When retrofitting the T-connector with a cable assembly incorporating


FD
termination resisters, separate termination resisters are unnecessary. FAX
SU
Cable assembly incorporating termination registers
Item Type Code Available time
Cable Assembly 80-580-0008 00019329110 September 2017 ⑦

MF
Revised Operator’s Manual: OME-72790-F DS
CI
GY
[Factory modified set]
100678 and after (May 2017)
After the factory modifications, the package of the CP20-0350 will include a cable ⑧
assembly incorporating termination resisters.
OTHERS

CONFIDENTIAL (internal use only) 1


This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO. FEC SEPT 2017
No. : FQ7-2017-007
Date: 2017-09
Information APPROVED BY
Issued by: FURUNO ELECTRIC CO., LTD
SERVICE MANAGEMENT & COMMANDING DEPARTMENT WRITTEN BY

Addenda No. 002 to GS-100 Service Manual Pub. No. SME-72790 ①

SONAR
Model GS-100 FNR
FNZ
Ver.03.02 Remedy for HDG Stopped

36
[Urgency]
When symptom occurs / At installation E/S
FCV

11
[Symptom]
Alert “240 System fault” appears, and data output of “Heading, Position, and 3-axis speed”
is stopped. The alert list shows the all or part of Table 1.

Alert No. Alert name 27


Table1 Generated alerts
RADAR
02
211 No calculation of position
212 Loss of position
240 System fault
24

430302 Output Stopped (HDG) ④


430311 Output Stopped (Speed)
Note: when a symptom occurs, alert 240 always appears. NAV
20

[Cause]
an

CAN communication is stopped due to software processing failures. ⑤

[Remedy] SSB
m

Update the software of the antenna unit to Ver.03.02.


jk

Table 2 New/Old software versions


New Old ⑥
sl

2051522-03.02 2051522-03.01
FD
Notice) FAX
SU
- Restarting the antenna unit enable you to restore the symptom.
Note: Even if the display unit is restarted, the antenna unit is not restarted.
Therefore, the power supply side to the junction box must be restarted.
- If the symptom is not restored after the antenna unit is restarted, the T-connector ⑦
may cause connection failures. If the connector of the pigtail cable is damaged,
replace the pigtail cable (MJ-A10SPF0016-010C) with the cable assembly MF
incorporating termination resisters (80-580-0008). DS
CI
Relevant FURUNO Info: FQ7-2017-006 (GS-100 Change to Cable Assembly GY
Incorporating Termination Resisters)

[Factory modified sets]
TBA OTHERS

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons.
FEC SEPT 2017
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Contents
Contents

Chapter 1 Overview
1.1 Configuration ················································································· 1-1
1.2 Specifications ················································································ 1-2
1.2.1 GS-1001 (Antenna unit) ····························································· 1-2
1.2.2 GS-1002 (Display unit) ······························································· 1-2
1.2.3 Interface ················································································· 1-3
1.2.4 Power Supply ·········································································· 1-3
1.2.5 Environmental conditions···························································· 1-3

36
Chapter 2 Block Description

11
2.1 Basic structure of GS-100 ································································ 2-1
2.2 Main board functions ······································································· 2-2

27
2.3 Location of Parts ············································································ 2-5
2.3.1 GS-1001 (Antenna unit) ····························································· 2-5
02
2.3.1.1 MAIN (20P8193) ··································································· 2-6
2.3.1.2 GPS-LNA (20P8212C) + ELEMENT (DANB1590CR97T,
20S104740) ········································································· 2-7
24

2.3.2 GS-1002 (Display unit) ······························································· 2-8


2.3.2.1 MAIN (20P8209) ··································································· 2-9
20

2.3.2.2 CAN (20P8213) ··································································· 2-10


2.3.2.3 CAN-FIL (20P8218) ······························································ 2-11
an

2.3.2.4 PNL (20P8210) ··································································· 2-11


2.3.2.5 LCD ·················································································· 2-12
2.3.3 GS-1003 (Junction box) ···························································· 2-13
m

2.3.3.1 TB (20P8221) ····································································· 2-14


jk

Chapter 3 Service Menu


sl

3.1 How to display service menu ···························································· 3-1


3.2 Service menu tree ·········································································· 3-2

Chapter 4 Upgrade Software


4.1 Overview ······················································································ 4-1
4.2 Updating the software for antenna unit (GS-1001) and display unit
(GS-1002) ····················································································· 4-1
4.2.1 Required components ································································ 4-1
4.2.2 Software file ············································································ 4-2
4.2.3 Procedure for updating the software ············································· 4-3

i
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Contents

4.3 Updating the software for remote display (DS-600) ································ 4-7
4.3.1 Required components ································································ 4-7
4.3.2 Software file ············································································ 4-7
4.3.3 Connection ·············································································· 4-8
4.3.4 PC network setting ···································································· 4-8
4.3.5 Procedure for updating the software ············································· 4-9

Chapter 5 Maintenance

36
5.1 Test point ······················································································ 5-1
5.1.1 GS-1001 (antenna unit): MAIN board (20P8193A) ··························· 5-1

11
5.1.2 GS-1002 (display unit): MAIN board (20P8209) ······························· 5-3
5.1.3 CAN (20P8213) ········································································ 5-4
5.2 Replacing the main parts ································································· 5-5

27
5.3 Compatibility of main parts ······························································· 5-8
5.4 Alart ···························································································· 5-8
02
5.5 When “240 System fault” message appears ········································· 5-9
5.6 FURUNO information issue history ····················································· 5-9
24

5.7 Q&A ··························································································· 5-10

Supplement: List of Figures ···················································· AP


20

Internal interconnection diagram ································································· D1


Outline drawing ······················································································· D4
an

Drawing ································································································ D9
m
jk
sl

Windows is a trademark or registered trademark of Microsoft Corporation in the


U.S. and other countries.
Other company names and product names are generally trademarks or
registered trademarks of their respective owners.

ii
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 1. Overview
Chapter 1 Overview

GS-100 (Satellite Speed Log), with a high-resolution 5.7-inch color LCD, can display
various navigation data. The vessel speed accuracy is 0.02 knot (5 satellites or more).
The built-in satellite compass allows for displaying the right- and left-side vessel speeds
at any place on the vessel. The equipment can be connected with an optional 8.4-inch
color LCD (DS-600) to help berthing.

1.1 Configuration
Basically, the equipment is composed of GS-1001 (antenna unit), GS-1002 (display
unit), and GS-1003 (junction box).

36
GS-1001
(antenna unit)

11
Network device,

27
HUB, etc.

Navigation
equipment,
02
DC24V IF-2503, etc.

USB memory
24

Rectifier DS-600
PR-62 or PR-240 (Sub display)
GS-1002 (display unit)
20

GS-1003
(junction box)

Fig. 1.1 Structure of GS-100


an

- The table below shows the software version of each unit.


m

Unit Name Number


GPS 48502630xx
jk

GS-1001 (antenna unit)


ANT 2051522-0.xx
sl

GS-1002 (display unit) MAIN 2051522-0x.xx


Starter 6652000-0x.xx
DS-600 (remote
Booter 6652001-0x.xx
display)
Main 6652002-0x.xx

- The table below shows the fuse types for GS-1003 (junction box) and DS-600 (remote
display).
Unit name Part name Type Code
GS-1003 Fuse FGMB 125V 3A PBF 000-157-481-10
DS-600 Fuse FGMB 125V 2A PBF 000-157-479-10

1-1
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 1 Overview

- Consumable parts are the LCD of GS-1002 (display unit) and the backlight of DS-600
(remote display).
When the end of life is reached, the display cannot provide adequate brightness.
To exchange consumable parts, order the following:
Unit name Part name Model Code Service life
LCD Approx.
GS-1002 GP-170 001-321-290-00
assembly 60,000 hrs
Approx.
DS-600 Backlight DS-600 PNL/LCD 001-098-070-00
30,000 hrs

36
1.2 Specifications
1.2.1 GS-1001 (Antenna unit)

11
Receiving frequency 1575.42 MHz

27
Tracking code CA code
Number of channel GPS: 12 channels parallel, 12 satellites
Position GPS: Approx. 10 m (2 drms, HDOP < 4)
02
measurement SBAS: Approx. 7 m (2 drms, HDOP < 4)
Speed 2.0% or 0.2 knot, whichever is greater (tracking
satellite: 3 or 4)
24

0.02 knot rms (tracking satellite: 5 or more, at


Accuracy antenna position)
0.08 knot rms (tracking satellite: 5 or more, at
20

antenna position)
Trip distance 0.01 NM
Heading/Roll/Pitch 0.5° RMS
an

1.2.2 GS-1002 (Display unit)


m

Screen 5.7-inch LCD, 116.16 × 87.12 mm, 640 × 480 (VGA)


jk

Picture color 262,144 colors


sl

Brilliance 700 cd/m2


Display mode Text screen, graph screen
Ship’s position, Speed, Heading, Satellite information, Date, Time,
Status icon, ROT, Current*, Wind direction/speed*, Depth*,
Display data
Doppler SOG/COG*, Roll, Pitch, Heave, Trip (time/distance),
System information (*:external data required)
Satellite Satellite number, Azimuth, Elevation, Signal level, DOP, Status
information
Own ship’s position lost, Heading data missing, Speed data
Alarm missing, HDOP overshoot, Heading data estimated, System error,
Internal sensor error, AMS communication error
Speed: 4.5 m, Trip distance: 2.2 m, Heading: 5.5 m,
Visible range
Other: 0.625 m

1-2
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 1 Overview

1.2.3 Interface
Serial Input/output: 3 ports, Output: 1 port
No. of Ethernet 1 port (100 Base-TX)
ports USB 1 port (for maintenance)
CAN 1 port (for antenna unit)
IEC61162-1/2 (NMEA0183 V1.5/2.0/4.0)
Data format
IEC61162-450

36
1.2.4 Power Supply

11
Junction box 24 VDC: 0.6 A (supplied to display unit and antenna unit)
PR-240 100-115/200-230 VAC, 1 phase, 50/60 Hz, 24 VDC (backup)
Rectifier
PR-62
27
100/110/115/220/230 VAC, 1 phase, 50/60 Hz
02
1.2.5 Environmental conditions
24

Antenna unit -25ºC to +70ºC


Ambient Display unit/ junction
-15ºC to +55ºC
temperature box
20

Display unit (DS-600) -25ºC to +55ºC


Relative humidity 95% or less (+40°C)
an

Antenna unit IP56

Degree of Display unit IP25, IPX0 (with the USB port opened)
m

protection Junction box IP22


jk

Display unit (DS-600) IP25 (front panel)


Vibration IEC60945 Ed.4
sl

1-3
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2. BlockChapter
Description
2 Block Description

2.1 Basic configuration of GS-100

GS-1001 (Antenna unit)


GPS-LNA
(20P8212 Type C)

ELEMENT

MAIN (DANB1590CR97T)

36
(20P8193A)
GPS-LNA
(20P8212 Type C)

11
ELEMENT

(DANB1590CR97T)

27
02
GS-1002 (Display unit)

(DATA1)
24

CAN

J3
J13
J1

(20P8213)
GS-1003 J2
20

(DATA2)
(Junction
J4
box) TB4 J2

CAN-FIL
TB3
an
J1

TB
(DATA3)

(20P8218) MAIN
J5

(20P8221)
TB2

J1

(20P8209)
m

(DATA4)

TB1
J6
J12

LCD
jk

(NETWORK)
sl

24VDC PNL
J2
J11
J2

(20P8210)
J3
(USB)

Fig. 2.1 Basic configuration of GS-100

2-1
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.2 Main board functions


Table 2.1 Main board functions

Unit Board Function

Power supply
The front stage of primary power block is provided
with reverse connection/EMC protection filters and
undervoltage/overtolgage protection circuits.
In the primary power block, voltage is reduced from

36
9–38 VDC to 5.8 VDC.
Then, the 5.8 VDC voltage is reduced to 3.3 VDC,
and the 3.3 VDC voltage is reduced to 1.8 VDC, to

11
use the power for the digital. Also, a voltage of 5.8
VDC is reduced to 5.0 VDC and 5.2 VDC, so that the
power can be used for the sensors, GPS cores, and
antennas.

27
Antenna unit (GNSS core)
Supplies power to the GNSS-LNA antenna and
02
calculates the “UTC, position, speed, and carrier
phase of GPSL1” from the analog signals from the
MAIN antenna.
(20P8193A) These data are sent to the digital via the serial port.
24

Sensor
GS-1001 It has an IMU (Inertia Measurement Unit) composed
20

(Antenna of a triaxial gyroscope and a triaxial accelerometer.


unit) Sensor information is converted into analog signals
and sent to the digital via the serial port.
an

Digital
Calculates the orientation between the antennas,
pitch, speed, and location, based on the information
m

from the two GNSS cores.


It also calculates the roll, pitch, bearing, speed, and
location from the IMU output in the strap-down
jk

system (with reference to the direction of


gravitational force). These data allow the user to
sl

quickly obtain highly accurate roll, pitch and bearing


information.
These data are sent to the display unit via CAN.
Antenna
Combines radio waves fed at 2 points and inputs
GPS signals to the LNA.
GPS-LNA LNA
(20P8212C) It is composed of a band path filter, 1st AMP, and
2nd AMP. The back stage of antenna element and
the front stage of S.FL2 connector are protected
from surges.

2-2
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

Reference) GS-100 uses 20P8212C.


Type A: Used for GP-170 antenna GPA-20S.
GPS-LNA Type B: Used for GP-170 antenna GPA-21S.
(20P8212C) Type C: Used for SC-30/GS-1001.
GS-1001 Type D: Used for SC-50/110.
(Antenna * SC-70/130 uses GNSS-compatible antennas.
unit) Antenna element mounted on GNSS-LNA
ELEMENT (20P8212). For carrier positioning, the dual-point
(DANB1590CR feed system is used to reduce the effects of
97T) multipath. General GPS and GNSS devices use the
single-feed system.

36
Power supply
The front stage of primary power block is provided
with reverse connection/EMC protection filters and
undervoltage/overtolgage protection circuits. The

11
output stage, where power is supplied to other
blocks, has overvoltage protection circuits.
In the primary power block, 12 - 24 VDC is converted

27
into a single output of 12 VDC. The 12 VDC voltage
is reduced to 5.1 VDC, then the 5.1 VDC voltage is
reduced to 3.3 VDC, and the 3.3 VDC voltage is
reduced to 1.45 VDC and 1.5 VDC, to use the power
02
MAIN for the digital.
(20P8209)
LCD driver
GS-1002
24

Generates a backlight for the LCD using a special


(Display
IC, and supplies the backlight to the LCD. The LCD
unit)
interface (related to drawing) has a CPU function
and controls the brightness.
20

Digital
Communicates with the antenna unit using the
an

built-in CAN module, and displays and outputs


(serial/LAN) obtained data, such as time, position,
speed, roll, pitch, heave, and triaxial speed.
It is composed of a digital isolator, CAN transceiver,
m

switching regulator (3.3 V, for digital).


CAN It is isolated between the CAN Bus side and the
jk

(20P8213) MAIN board (20P8209) side. The MAIN board side


operates at 3.3 VDC. The CAN Bus side operates at
sl

5.0 VDC reduced from 24 VDC.


It is composed of a CAN connector and filter circuit.
CAN-FIL
The filter circuit provides the NMEA2000
(20P8218)
communication line with surge and EMC protection.
It is composed of the following components:
- USB connector and filter
PNL
- Buzzer (CPU control)
(20P8210)
- LEC for operation key (CPU control)
- Operation key signal (CPU detection)

2-3
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

High-resolution 5.7-inch color LCD (116.16 mm ×


GS-1002
87.12 mm)
(Display LCD
- Display color: 262,144 colors
unit)
- Brightness: 700 cd/m2
- Distributes on-board power (24 VDC) to GS-1001
GS-1003
TB and GS-1002 through the filter circuit for EMC
(Junction
(20P8221) protection.
box)
- Overcurrent protection with 3A fuse

36
11
27
02
24
20
an
m
jk
sl

2-4
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3 Location of Parts


2.3.1 GS-1001 (Antenna unit)

36
11
27
02
Antenna
24

Antenna
element
element
20
an
m

Antenna element (rear side)


jk

Connectors
to rate gyro
Rate gyro y
sl

(x axis)
(z axis)
Rate gyro z

(y axis)
Rate gyro x

Fig. 2.2 GS-1001 (Antenna unit)

2-5
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.1.1 MAIN (20P8193)

36
11
to TB: TB4 J1: Not used
27
02
Fig. 2.3 MAIN (20P8193) Side A
24
20
an
m
jk
sl

Fig. 2.4 MAIN (20P8193) Side B

2-6
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.1.2 GPS-LNA (20P8212C) + ELEMENT (DANB1590CR97T, 20S104740)

GPS-LNA ELEMENT
(20P8212) (DANB1590CR97T(20S104740)) to MAIN: J2

36
11
27
02
Fig. 2.5 GPS-LNA + ELEMENT Side A Fig. 2.6 GPS-LNA + ELEMENT Side B
24
20
an
m
jk
sl

Fig. 2.7 GPS-LNA + ELEMENT with the cover attached

Note) Figs. 2.5 through 2.7 show the GPS-LNA for Type D (for SC-50/110).
GS-1001 is Type C. J2 in Fig. 2.6 is an S.FL2 connector.

2-7
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.2 GS-1002 (Display unit)

36
11
27
02
24

CAN-FIL
20

(20P8218)
an

CAN
(20P8213)
m
jk
sl

PNL MAIN LCD


(20P8210) (20P8209)

Fig. 2.8 GS-1002 (display unit)

2-8
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.2.1 MAIN (20P8209)


J8 J7 J13 J16 J12
(Not used) (Not used) (to CAN:J1) (Not used) (to LCD)

DIPSW
(S3)
J10
(to PNL:J1)

J14

36
(to LCD)
J11
(to PNL:J2)

11
Jumper
(J15)

J2 J3 J4 J5 J6
27 J1
02
(NETWORK) (DATA1) (DATA2) (DATA3) (DATA4) (PWR)

Fig. 2.9 MAIN (20P8209) Side A


24

Table 2.2 DIPSW (S3) settings


20

Setting
No. Remarks
value
1 ON
an

2 ON Do not change the


initial settings on the
3 OFF left.
m

4 OFF
jk

Table 2.3 J15 (Termination setting for IEC 61162-2)


sl

Setting value Remarks


Short the circuit
Terminate at 110 Ω (default).
between #1 and #2.
Short the circuit Open
between #2 and #3. (When terminated outside
No short pin. the equipment)

* When terminate the wire outside, change the setting.

2-9
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

36
11
Fig. 2.10 MAIN (20P8209) Side B

2.3.2.2 CAN (20P8213)


27
02
24

J2
(to CAN-FIL:J2) J1
(to MAIN:J13)
20
an
m

Fig. 2.11 CAN (20P8213) Side A


jk
sl

Fig. 2.12 CAN (20P8213) Side B

2-10
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.2.3 CAN-FIL (20P8218)

J2
(to CAN: J2)

J1

36
(to TB: TB3)

11
Fig. 2.13 CAN-FIL (20P8218) Side A Fig. 2.14 CAN-FIL (20P8218) Side B

2.3.2.4 PNL (20P8210)


27
02
24

J3
(to USB)
20
an
m

Fig. 2.15 PNL (20P8210) Side A


jk
sl

J2
(to MAIN: J11)

J1
(to MAIN:J14)

Fig. 2.16 PNL (20P8210) Side B

2-11
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.2.5 LCD

36
11
27
Fig. 2.17 LCD Side A
02
24
20

J1
(to MAIN: J12)
an
m
jk
sl

Fig. 2.18 LCD Side B

2-12
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.3 GS-1003 (Junction box)

36
11
27
02
24
20
an
m
jk
sl

Fig. 2.19 GS-1003 (Junction box)

2-13
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 2 Block Description

2.3.3.1 TB (20P8221)
Termination pin (J1)

TB5
(Backup)

TB4
(to GS-1001/MAIN)

36
TB3
Fuse 3A

11
(to GS-1002/CANFIL: J1)

27
TB1 TB2
(to 24VDC) (to GS-1002/MAIN: J1)
02
Fig. 2.20 TB (20P8221) Side A
24

Table 2.4 Termination setting for CAN Bus (J1)


Setting value Remarks
20

Short the circuit Terminate at 120 Ω


between #1 and #2. (default).
Short the circuit
Open (Not used)
an

between #2 and #3.


m
jk
sl

Fig. 2.21 TB (20P8221) Side B

2-14
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 3. Service3 Service
Menu Menu

3.1 How to display service menu


To display the service menu, follow the procedure below.
Step 1) Display the 3-axis speed graphic screen.

36
11
27
02
24

Fig. 3.1 3-axis speed graphic screen


20

Step 2) Enable the service menu by pressing the panel keys in the following order:
↑↑↓↓←→←→1111
an
m
jk
sl

3-1
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

3.2 Service menu tree


2. Speed / Trip distance
Speed Test Used for speed trial.
See Section 8.7 of the instruction manual.

36
↓ Select 1. Yes. Reboot the equipment. The following

11
screen appears.

27
02
↓ Press the ENT key. The calculation starts.
24
20
an

4. Maintenance
Sound Test
DO NOT CHANGE. For factory use. See Section 7.6 of the instruction manual.
m
jk
sl

Upgrade the software


data Displays the software update menu.
See Chapter 4 Updating the Software of this manual.
Part replacement
Resets the operating time before the replacement of board
or other component.
Enter an offset when the gyroscope is replaced.
See Section 5.2 Replacing the major parts of this manual.

3-2
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

Sensor information
Check it in case of bearing stop or other errors.

1. Accelerometer Status
Displays the state of accelerometer.
OK: Normal
X and Y axes broken down:
There may be a breakdown. The accelerometer is
mounted on the MAIN board 20P8193.
Replace the MAIN board 20P8193.

36
2. Accelerometer Saturation
Displays the state of accelerometer.
OK: Normal

11
X and Y axes saturated:
Signals may be saturated due to vibration. Check the
equipment position.

3. Rate Gyro Status


27
Displays the state of gyroscope.
02
OK: Normal
X and Y axes broken down:
There may be a breakdown. Replace the gyroscope. After
24

replacement, be sure to enter an offset for the gyroscope.

4. Rate Gyro Saturation


20

Displays the state of gyroscope.


OK: Normal
X and Y axes saturated:
an

Signals may be saturated due to vibration. Check the


equipment position.
m

5. Calc
Displays the calculation result of GPS speed.
jk

Normal: OK
In case of error, the following message appears:
sl

1) Cannot calculate vessel speed, etc. due to an


insufficient number of acquired satellites.
Output Status
“Dead-reckoning (< 1 min)”
“Dead-reckoning (< 5 min)”
“Output stopped”
“Not Expected”

3-3
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

2) Cannot calculate data due to an insufficient number of


satellites or the existence of a satellite affected by
multipath.
Ambiguity Status
“Common SV’s are less than 5.”
“No candidates”
“Check Error1”
“Check Error2”
“Not Expected”

36
Ambiguity Check Status
“Baseline check is NG”
“Other check is NG”

11
“Not expected”

6. Inst

27
Determines the equipment location. It determines if GPS
signal shielding due to a ship structure or vibration affects
accelerometer or gyroscope.
02
OK: Normal
In case of error, the following message appears:
“SV’s are Blocked”
24

“GS-1001 is vibrated”

7. GPS
Displays the GPS reception state.
20

If NG is displayed, GPS is not received.


OK: Normal
In case of error, the following message appears:
an

“GPS1 tracking is NG.”


“GPS2 tracking is NG.”
“Both tracking are NG.”
m
jk
sl

3-4
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

5. Data input/output
SFI When there is more than one vessel speed meter or
heading device on the IEC61162-450 system, set whether
the GS-100 outputs data as SDME (Speed and Distance
Measuring Equipment)
or
THD(Transmitting Heading Device)
using a talker and a 4-digit number.
For SDME type approval setting
Talker: VD + 4-digit number
For THD type approval setting

36
Talker: HE + 4-digit number

11
27
02
24

IP setting, etc. Configures IEC61162-450.


20
an
m

Line monitor Configures the output of raw data for fault analysis from
GS-1001 the USB or network port on the display unit. Configure the
jk

setting according to the output destination.


For “USB”
sl

Saves raw data for fault analysis in a USB memory.


For “UDP”
Outputs raw data for fault analysis to a destination
configured in the port setting for maintenance.

3-5
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

GNSS Sentence Output GS-100 is not GPS type approval equipment.


DO NOT CHANGE. Basically do not change the settings.
* When connecting DS-600, set this setting to “Enable”
because an output of GGA is required.
See “8.6.3 Settings for GS-1002” of the instruction
manual.

36
6. Sensor setting

11
HDG Offset Enter an offset for heading.
See Section 8.4.7 of the operator’s manual.

27
02
24

Position Offset Enter an offset for the position.


See Section 8.4.7 of the operator’s manual.
20
an
m
jk
sl

3-6
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

ShipSize/ANT/CALC-SPD Enter the antenna equipment position.


POS See Section 8.4.7 of the operator’s manual.

36
11
SOG Correction 27
Enter a correction value for vessel speed.
02
See Section 8.4.7 of the operator’s manual.
24
20

GPS source A menu for switching the position measurement source


Do not use. using an input from the antenna unit or external input.
an

Planned to be available in the future.


m
jk
sl

3-7
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

7. System setting
Master Sensor A menu used when two antennas are mounted. Planned to
Do not use. be available in the future. Do not use it.

Ethernet Set an IP address.

36
See Section 8.4.9 of the operator’s manual.

11
27
02
Maintenance Port A port for RMS. Do not use it.
24

Do not use.
20
an

Tech Menu A menu for developers. Do not use it.


Do not use.
m
jk
sl

3-8
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
3 Service Menu

Factory Default Used for resetting the equipment to factory default.


The following menu items will not be reset to factory
default:
4. Maintenance
Buzzer sound test
Buzzer sound/frequency
Buzzer sound/voltage
Part replacement
Serial number
Gyroscope offset

36
11
27
02
24
20
an
m
jk
sl

3-9
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4. Upgrade Software
Chapter 4 Upgrade the Software

4.1 Overview
1) To update the software, perform the following procedure:
Antenna unit (GS-1001), Display unit (GS-1002)
Insert a USB memory into the USB port on the front side of display unit (GS-1002).
Remote display (DS-600)
Connect the LAN port located on the rear side of remote display (DS-600) with the
PC via the hub.
2) The software version numbers of the units are as follows:

36
Unit Name Number
GPS 48502630xx
GS-1001

11
ANT 2051522-0.xx
GS-1002 MAIN 2051522-0x.xx
Starter 6652000-0x.xx
DS-600 Booter
Main 27 6652001-0x.xx
6652002-0x.xx
02
* You cannot update the version of GPS software in the field.
24

4.2 Upgrade the software for antenna unit (GS-1001) and


display unit (GS-1002)
20

4.2.1 Required components


1) Software
an

Software is prepared for each unit.


2) USB memory for update
m

The software holder downloaded from the distributor’s web or Technet is compressed
in a zip file. Decompress the file and save it directly under the USB memory.
jk

Notes)
1. The name of decompressed software folder is “gp170” for any unit.
sl

2. You can save only a software holder for one unit under the USB memory.
Since you cannot change the software holder name, if you save more than one unit,
the existing file will be overwritten.

4-1
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4.2.2 Software file


The software holder is composed of the following files:
Do not change the folder structure.

unzip

36
11
27
02
24

Fig. 4.1 Folder of antenna unit (GS-1001)


20

unzip
an
m
jk
sl

Fig. 4.2 Folder of display unit (GS-1002)

4-2
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4.2.3 Procedure for updating the software


1) Press the power key on the front side of display unit (GS-1002) to turn on the power.

2) Insert the USB memory containing the software folder into the USB port located on
the front side of display unit (GS-1002).
* Activate the display unit (GS-1002) before inserting the USB memory.
If the USB memory is inserted before the display unit (GS-1002) is activated,
the software will not be updated successfully.

36
ENT key

11
27
02
Power key
USB port
24

Fig. 4.3 Display unit (GS-1002), front side


20

3) Go to the 3-axis speed graphic screen.


* If the digital navigation data screen is displayed, you can switch the screen by
an

pressing the ENT key.


m
jk
sl

Fig. 4.4 3-axis speed graphic screen

4) Enable the service menu by pressing the panel keys in the following order:
↑↑↓↓←→←→1111

4-3
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

5) Update the software by executing the following menus:

MENU
 1 Maintenance
 4 SW/Data Update
 1 Chk the available software
- For updating the application for display unit (GS-1002)  1 Main:
Application
- For updating the boot for display unit (GS-1002)  2 Main: Boot
- For updating the antenna unit (GS-1001)  3 GPS: Application (GPS:

36
Application)
Reference)

11
If the display unit (GS-1002) cannot read USB memory data in Step 5), the error
messages shown in the table below appear. The error messages disappear when the
MENU key is pressed.
Error message

English: No USB !
27 Description
No USB memory is inserted.
02
Insert a USB memory and repeat from Step 1).
No software is saved in the inserted USB
memory.
24

English: No File ! Save the software in the USB memory, and


insert the USB memory. After that, repeat from
Step 1).
20
an
m

Fig. 4.5 Example of error message: No USB !


jk

6) A popup as shown in the figure below appears. Confirm the software version to be
updated, and select “2. YES.”
sl

* From this step onward, images displayed during the execution of “Main:
Application” are used for the description.

Current version

Updated version

Fig. 4.6 Checking the software version

4-4
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

7) After the screen goes black, an update screen as shown below appears.
The update progress (%) is displayed at the bottom of the screen. When it reaches
100%, a blip sound is heard and the display unit (GS-1002) starts up. The software
update is completed in several minutes.

<USB LOADER> u/ update.ini


FILE : /gp170/main/application/gp170app.bin
BLOCK :MAIN
PROGRAMNE: APPLICATION (2)

36
VERSION : 2051552-02.01
MESSAGE : ver(INT) T2.13 r4060

11
COMMENT : This is the update disk for GS-100

Update
progress

27
73% [******************************************> ]
02
USB LOADER ver.2014-03.01 4521

Fig. 4.7 Software update in progress


24

Reference)
If data cannot be read correctly during update, the following message appears:
20

Error message Error description


A data reading error is occurring.
an

English: Backup data error is Download the software again, save the
detected. software in the USB memory, and insert the
This unit uses default USB memory. After that, repeat from Step 1).
settings. It also occurs if the USB memory is removed
m

during data reading.


jk
sl

4-5
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

8) Confirm the software version in the “Start” or “Automatic Test” screen.

Start screen

36
11
27
02
24
20

Automatic Test
an
m
jk
sl

Fig. 4.8 Checking the software version

4-6
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4.3 Upgrade the software for remote display (DS-600)


4.3.1 Required components
1) PC containing the software (Recommended OS: Windows® XP or Windows® 7)
2) HUB
3) Two LAN cables

Notes)
1. The type of LAN cable to be prepared (straight or cross) differs depending on

36
whether the hub is compatible with the Auto MDI / MDI-X function. See the
following table to prepare proper cables:
Type of hub Type of LAN cable

11
Compatible with Auto MDI / Both straight or cross type can
MDI-X be used.
Not compatible with Auto One each from straight and

27
MDI / MDI-X cross types.

2. If the PC and the unit is connected without using the hub, update may fail due to the
02
PC specifications. To eliminate the problem caused by compatibility between the PC
specifications and DC-60, be sure to connect the PC and the unit via the hub.
3. The software holder downloaded from the distributor’s web or Technet is
24

compressed in a zip file. Decompress the file and save it directly under the C drive
of the PC.
20

4.3.2 Software file


an

The software holder is composed of the following files:


Do not change the folder structure.
m

unzip
jk
sl

Fig. 4.9 Folder of remote display (DS-600)

4-7
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4.3.3 Connection
Turn off the power of remote display (DS-600), and connect the unit as shown
below.

Connect to “NETWORK” on the back


side of DS-600

36
HUB PC

11
LAN LAN

Power

27
Fig. 4.10 Connection for updating the remote display (DS-600) software
02
4.3.4 PC network setting
1) Select “Start”  “Control Panel”  “Network Connection”  “Local Area
24

Connection”. Then open “Properties.”


2) Select “Internet Protocol (TCP/IP)” and open “Properties.”
3) Configure the network setting as shown below, and click “OK.”
20

Reference) The factory set IP address of DS-600 is 172.31.66.3.


an
m

IP address: 172.31.66.200
jk

Subnet mask: 255.255.0.0


Default gateway: Blank
sl

Fig. 4.11 PC network setting

4-8
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4.3.5 Procedure for updating the software


Note)
The software update is completed in about 1 minute.
If the progress rate (%) displayed during the software update does not reach 100%
after a time period much longer than should be necessary to complete the task, or if the
LED on the board that indicates normal operation does not flash, then perform the
update again from the start.

36
1) Open the software folder in the PC, and double-click “DS-600LanLoad.bat.”

11
27
02
24

Fig. 4.12 PC network setting

2) Check that the following screen appears:


20
an

IP address configured on the PC


m

Fig. 4.13 Running “DS-600LanLoad.bat”


jk

3) Turn on the power of DS-600.


sl

The update progress rate (%) is displayed, and the rate increases as writing
progresses.

Update
progress

Fig. 4.14 Screen displayed during software update

4-9
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 4 Upgrade the Software

4) The software update is completed when the update progress reaches 100% and
“Processing complete” appears.
Press a key on the PC reboots DS-600.

36
Completed
Press any key to continue……...

11
Fig. 4.15 Software upgrade completed

27
5) Check the software version on the display Unit TEST.
1. Press the MENU ESC key on the DS-600 to open the menu.
2. Select “TESTS”  “Display Unit TEST.”
02
3. Check the software version on the Self Test screen.
4. Press the MENU ESC key 3 times to close Display Unit TEST.
24
20
an

Software version
m
jk
sl

Fig. 4.16 Display Unit TEST

4-10
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5. Maintenance
Chapter 5 Maintenance

5.1 Test point


5.1.1 GS-1001 (Antenna unit): MAIN board (20P8193A)

36
11
CR20, 19, and

27
18 from the left
02
TP2
24

TP1
20

Fig. 5.1.1 Test points for MAIN board (20P8193A)


an

TP number Signal name Standard value


TP2 Switching frequency 100 kHz to 130 kHz
m

Note) During TP2 measurement, use TP1 for GND.


jk
sl

8.28 μs  120 kHz

Fig. 5.1.2 Example of measurement of test point P2

5-1
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

LED
Description
number
Flashing: The software is working properly.
CR18
Off: The software is not working. Update the software.
Flashing at 200-ms intervals: Two GPS cores are
measuring positions.
CR19
Flashing at irregular intervals: Initialization is in progress.
At this time, CR20 is off.
Flashing at 200-ms intervals: GPS bearing is obtained.
CR20
Off: GPS bearing is not obtained.

36
11
27
02
24
20
an
m
jk
sl

5-2
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.1.2 GS-1002 (Display unit): MAIN board (20P8209)

TP8
(GND) TP10
(GND)

TP501
CR17 and 18 12 V test point

36
from the top
(Only for
developers)

11
1.5 V test pad 1.45 V test pad 3.3 V test pad

27
02
24

Fig. 5.1.3 Test points for MAIN board (20P8209)


20

Test point/pad Standard value


12.0 V (TP501) 11.4 VDC to 12.6 VDC
5.1 V 4.99 VDC to 5.21 VDC
an

3.3 V 3.27 VDC to 3.33 VDC


1.5 V 1.47 VDC to 1.53 VDC
m

1.45 V 1.449 VDC to 1.462 VDC


Note) During voltage measurement, use TP8 or TP10
for GND.
jk
sl

5-3
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.1.3 CAN (20P8213)


5.0 V GND 3.3 V test pad

5.0 V test pad

36
11
3.3 V GND

Fig. 5.1.4 Test points for CAN (20P8213)

Test pad 27
Standard value
02
5.0 VDC 4.76 VDC to 5.24VDC
3.3 VDC 3.1 VDC to 3.5VDC
24

Note) Since 5.0 VDC and 3.3 VDC are isolated,


different GNDs must be used.
20
an
m
jk
sl

5-4
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.2 Replacing the main parts


For replacing the parts, follow the instruction listed in the table below.

Action
Unit Part name
Before replacement After replacement
CPU board Not required
GS-1001 Rate gyro (x) Set a correction value
(Antenna for the rate gyro.
unit) Rate gyro (y)
Reset the operating time of (See Section 5.2.2 of

36
Rate gyro (z) replacement part. this manual.)
LCD (See Section 5.2.1 of this Not required
GS-1002 manual.)

11
Perform the tasks
(Display described in “8.4 Post
unit) CPU board
Installation Setting” of
Operator’s Manual.

5.2.1 Resetting the operation time of replacement part 27


02
Before replacing a part, reset the operating time of the part.
1. Display the service menu. (See Section 3.1 of this manual.)
2. In the main menu, select [4 Maintenance]  [5 Exchange].
24
20
an

Fig. 5.1.5 Part replacement


m

3. Select the unit of the part to be replaced.


Select [1 Display Unit] for GS-1002 (Display unit). Select [2 Sensor Unit] for
jk

GS-1001 (Antenna unit).


4. Select the part to be replaced.
sl

For [1 Display Unit], select [1 LCD] or [2 Main].


For [2 Sensor Unit], select [1 Main].

Fig. 5.1.6 Display Unit, Sensor Unit

5-5
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5. The message “Do you continue to do so?” appears. Select [1. Yes].
6. The message “Please turn off” appears. Press the power key to turn off the power.

Fig. 5.1.7 Do you continue to do so? Please turn off.

36
5.2.2 Setting a correction value for the rate gyro

11
After replacing a rate gyro, set a correction value for the rate gyro.
Notes for replacing the rate gyro
To avoid damage of the equipment, observe the
following instructions:
(1) Insert the connectors into correct positions.
(2) Do not set a correction value for the rate gyro
27
02
before replacing the rate gyro.
(3) Do not input a wrong correction value.
24

1. Display the service menu. (See Section 3.1 of this manual.)


2. In the main menu, open [4 Maintenance]  [5 Exchange]  [2 Sensor Unit].
20
an
m

Fig. 5.1.8 Sensor Unit


jk

3. Select the replaced rate gyro. The correction value input screen appears.
[2 Rate gyro (x)], [3 Rate gyro (y)] or [4 Rate gyro (z)]
sl

Fig. 5.1.9 Entering a correction value

5-6
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

4. Enter a correction value using the numeric keys, as shown below.


* For the correction value, see the label attached to the rate gyro.

36
11
3) Press the 5 key.

27
02
Fig. 5.1.10 Procedure for entering a correction value
24
20
an
m

Fig. 5.1.11 Checking the correction value


jk

5. Move the cursor to [Enter], and press the [ENT] key.


The message “Now processing...” is displayed. When the correction value is
sl

updated successfully, the previous screen appears.


If the correction value is not updated successfully, the following message appears:
- Response Error!!: A response was received from the antenna unit, but an
abnormal termination occurred.
Re-configure the correction value.
- Time Out!!!: No response was received from the antenna unit before time-out
(20 s).
Check the connection with the antenna unit, and re-configure the
correction value.

5-7
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.3 Compatibility of main parts


Components compatible with other models are as follows:

Model name Component name


SC-30 GPS-LNA (20P8212C)

5.4 Alert

36
There are 12 types of alert.
Alarm
Alarm name State Description

11
number
The value of HDOP (horizontal dilution
of precision) exceeds “4.” The threshold
210 HDOP exceeded Caution

27
value for HDOP cannot be changed from
“4.”
No calculation of
position No signal is received for 3 seconds from
02
211 Caution
Abbreviated messages: the core.
No calculation of POSN
212 Loss of position Caution There are no positioning data.
24

Unable to communication with the


antenna unit.
240 System fault Caution See the remedial action described in
20

“5.5 When “240 System fault” message


appears” of this manual.
The bearing is calculated using ROT
430301 Dead-Reckoning Warning
data instead of GPS position data.
an

430302 Output stopped (HDG) Caution The heading output is stopped.


The bearing for three-axis vessel speed
430303 EXT HDG/ROT Caution calculation was switched to the external
m

orientation.
430311 Output stopped (speed) Caution The speed output is stopped.
Three-axis speed is calculated using
jk

external bearing/ROT.
430312 EXT HDG applied Warning As time passes after the warning, the
sl

speed errors in the directions other than


heading increase.
430321 Rate gyro broken down Caution The rate gyro is faulty.
Accelerometer broken
430322 Caution The accelerometer is faulty.
down
Communication error A communication error is occurring in
430950 Caution
with BAM the alert management system.

5-8
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.5 When “240 System fault” message appears


The “240 System fault” warning is displayed if GS-1002 (display unit) cannot
communicate with GS-1001 (antenna unit).
If this warning is displayed even when there is no problem with wire connections or
antenna feed, reboot GS-1001 (antenna unit). Specifically, “remove the antenna cable
connected to GS-1001, and then insert it again”, or “turn OFF the 24 VDC power to
GS-1003 (junction box), and then turn it ON again.”
Note) GS-1001 does not reboot when GS-1002 (display unit) is rebooted.

36
11
27
02
5.6 FURUNO information issue history
Furuno information issued as of March 2017 is as follows:
24

FQ number Title
FQ7-2014-006 SC-30/GS-100 V.02.04 Sharing Software Base
20

FQ7-2014-010 GS-100/SC-30 Cover of Antenna Unit Changed


FQ7-2015-004 GS-100 Notice on Installation of Antenna Unit
an

FQ7-2015-010 GS-100 Remedy for Stop of Speed Data Display/Output


FQ7-2016-001 DS-60/80/GS-100 Speed Trial for EEDI Verification
FQ7-2016-003 GS-100 Service Menu
m
jk
sl

5-9
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

5.7 Q&A
Q1. Can I update the software of the antenna unit? Chapter 4
You cannot update the software of the antenna unit on site.

Q2. Is there any work required before or after software update? Chapter 4
There is no work required.
The setting values remain the same after the software update.

Q3. Software update fails. Chapter 4

36
If you insert a USB into GS-1002 and reboot the equipment before updating the
software, the update will not be executed properly. Also, make sure that the software has
a proper folder structure (see Section 4.2.3 of this manual) before copying it to a USB.

11
Observe the software procedure in Chapter 4.

Q4. How can I move to the service menu? Chapter 3

27
To enable the service menu, press the panel keys in the following order in the 3 axis
speed graphic screen:
02
↑↑↓↓←→←→1111

Q5. Is any backup battery used? Chapter 2


24

No backup battery is used.

Q6. Is there a check sheet that can be used during marine operation (such as those
20

used for DS-30)


Since the operation of the equipment as a speed meter is the same as that of DS series,
you can use the System Setup Data displayed on the Service Division website.
an

Q7. When a sub display (DS-600) is connected, only ROT and Heading are
displayed.
m

- Check the DS-600 setting to make sure that Operation is set to Sub.
Check the GS-100 settings to make sure that the baud rate is 38,400 bps, the sentence
jk

is GGA, VBW, and ZDA are 1s, and HDT and ROT are 0.1 s.
For details, see Section 8.6.2 of GS-100 Operator’s Manual.
sl

* To output GGA, you need to configure GNSS Sentence Output to Enable in the
service menu. (See Chapter 3 Service Menu of this manual.)
- Check that P sentences (PFEC) are output from the DATA port of GS-1002.

Q8. Can I remove “- - -” from the NAVIGATION screen of sub display DS-600?
You cannot remove it.

Q9. The sub display DS-600 sometimes shows “- - -” for the port-stbd speed of the
stern.
Check the settings described in Q7. Then check the connections for any problems.

5-10
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Q10. How can I display the service menu on the sub display DS-600?
While holding down the DISP key, press and hold down the power key until you hear a
beep sound. The screen below appears. In 90 seconds after this screen is displayed, the
serviceman menu appears on the screen.

36
11
27
02
Q11. The 3 axis speed screen does not appear on the sub display DS-600.
24

The 3 axis speed display uses VBW. Check that VBW containing 3 axis speed
information is output from GS-1002 (DATA1 port) to DS-600.
Also note that if DS-600 is set to STW display, the water tracking speed must be
20

externally input to GS-1002 as well.


If the device mode is THD, DS-600 cannot show the berthing screen. In such a case,
change the mode to SDME.
an
m
jk
sl

5-11
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Q12. The sideways speed and its direction are always the same between the
heading and the stern.
Set a new value in CALC-SPD POSN Y1.
CALC-SPD POSN Y1 (heading) and CALC-SPD POSN Y2 (stern) are initially set to
“000.0 m.” If the values are not changed, the sideways vessel speed becomes the same
between the fore and aft positions.

36
[6 Sensor setting]
 [1 Correction]
 [5 Equipment position]

11
27
02
Setting Description
The sideways speed can be measured at 2 positions apart from
the antenna position. Enter the distance between the reference
24

position (0) and the vessel speed measuring position (heading


CALC-SPD POSN Y1 direction).
CALC-SPD POSN Y2 In CALC-SPD POSN Y1 (heading), enter the distance to the
20

vessel speed measuring position. In CALC-SPD POSN Y2


(stern), enter “000.0 m” as the reference position.
The initial value is “000.0 m” for both Y1 and Y2.
This is a setting for weltering correction.
an

CALC-SPD POSN Z
In principle, do not change the initial value (000.0 m).
m
jk
sl

5-12
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Q13. The sideways speed differs between GS-100 and DS-60.


According to the Reference Point setting in DS-60 service menu, configure CALC-SPD
POSN Y1 of GS-100 as shown below.
Also, referring to Q12 above, configure CALC-SPD POSN Y2 and CALC-SPD POSN
Z.
Model DS-60 GS-100
Setting Reference Point CALC-SPD POSN Y1
Bow LOA
Setting
Transducer LOA-L1
value

36
Center LOA/2
* For LOA and L1, see the following figure:

11
27
02
24
20
an

DS-60 Setting Ship’s Data menu

Setting example 1)
m

When Reference Point is set to Bow and LOA is set to 300.0 m on DS-60, then set
CALC-SPD POSN Y1 of GS-100 to 300.0 m.
jk

Setting example 2)
sl

When Reference Point is set to Transducer, LOA is set to 300.0 m, and L1 is set to 15.0
m on DS-60, then set CALC-SPD POSN Y1 of GS-100 to 285.0 m.
Setting example 3)
When Reference Point is set to Center and LOA is set to 300.0 m on DS-60, then set
CALC-SPD POSN Y1 of GS-100 to 150.0 m.

5-13
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Q14. The speeds in the vertical and horizontal directions are different from those
indicated by other sensors.
- Check that the antenna direction is parallel to the heading line.
- Check that the heading offset (HDG Offset) is set.

[6 Sensor setting]
 [1 Correction]
 [1HDG Offset]

36
11
27
Q15. Difference in output sentence due to the difference of device mode
In SMDE, the talker of speed and heading signals is VD.
In THD, the talker of speed and heading signals is HE.
Examples of output sentence in each device mode are shown on the following pages.
02
24
20
an
m
jk
sl

5-14
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Example of output sentence when device mode is SMDE

SDME_IEC ed.3)
$PFEC,GPatt,1.0,9.8,0.0*48
$GPRMC,000149.60,A,3628.2522,N,13526.6550,E,2.3,130.2,011113,,,D*5E
$VDVLW,,N,,N,14034.750,N,0.000,N*5F
$VDZDA,000149.75,01,11,2013,00,00*6C
$VDHDT,1.0,T*31
$VDTHS,1.0,S*21
$PFEC,GPhve,0.000,A*3F

36
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGLL,3628.0261,N,13526.8701,E,000149.90,D,D*6B
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44

11
$GPGGA,000150.00,3627.7981,N,13527.0839,E,2,06,0.7,1.0,M,23.0,M,,*6D
$VDVTG,131.0,T,,M,2.3,N,4.3,K,D*08
$VDVBW,,,V,-1.48,1.76,A,,V,1.76,A*6F

27
$PFEC,ds060,D,C,TMC,G*07
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGNS,000150.20,3627.5683,N,13527.2965,E,D,06,0.7,1.0,23.0,,*07
02
$VDROT,6.0,A*32
$PFEC,GPatt,1.0,9.8,0.0*48
$GPRMC,000150.60,A,3627.2202,N,13527.6130,E,2.3,132.0,011113,,,D*5F
24

$VDVLW,,N,,N,14034.750,N,0.000,N*5F
$VDZDA,000150.75,01,11,2013,00,00*64
$VDHDT,1.0,T*31
20

$VDTHS,1.0,S*21
$PFEC,GPhve,0.000,A*3F
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
an

$GPGLL,3626.8680,N,13527.9266,E,000150.90,D,D*6A
$VDVTG,132.8,T,,M,2.3,N,4.3,K,D*03
$VDVBW,,,V,-1.53,1.72,A,,V,1.71,A*66
m

$PFEC,ds060,D,C,TMC,G*07
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
jk

$GPGGA,000151.00,3626.7497,N,13528.0305,E,2,06,0.7,1.0,M,23.0,M,,*6C
$VDROT,6.0,A*32
sl

$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGNS,000151.20,3626.3922,N,13528.3402,E,D,06,0.7,1.0,23.0,,*07

5-15
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

SDME_ IEC ed.4)


$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGNS,000119.20,3636.8459,N,13446.5802,E,D,06,0.7,1.0,23.0,,,S*7C
$VDROT,6.0,A*32
$VDHRM,0.0,,0.0,0.0,A*06
$PFEC,GPatt,1.0,9.9,0.0*49
$GPRMC,000119.60,A,3637.0873,N,13447.1068,E,2.3,70.2,011113,,,D,V*1E
$VDVLW,,N,,N,14034.750,N,0.000,N*5F
$VDZDA,000119.76,01,11,2013,00,00*6A
$VDHDT,1.0,T*31

36
$VDTHS,1.0,S*21
$PFEC,GPhve,0.000,A*3F
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44

11
$GPGLL,3637.2622,N,13447.5034,E,000119.90,D,D*6B
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGGA,000120.00,3637.3194,N,13447.6359,E,2,06,0.7,1.0,M,23.0,M,,*6F

27
$VDVTG,71.0,T,,M,2.3,N,4.3,K,D*3D
$VDVBW,,,V,0.79,2.16,A,,V,2.16,A*41
$PFEC,ds060,D,C,TMC,G*07
02
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$GPGNS,000120.20,3637.4320,N,13447.9014,E,D,06,0.7,1.0,23.0,,,S*70
$VDROT,6.0,A*32
24

$VDHRM,0.0,,0.0,0.0,A*06
$PFEC,GPatt,1.0,9.9,0.0*49
$GPRMC,000120.60,A,3637.5966,N,13448.3008,E,2.3,72.0,011113,,,D,V*1F
20

$VDVLW,,N,,N,14034.750,N,0.000,N*5F
$VDZDA,000120.76,01,11,2013,00,00*60
$VDHDT,1.0,T*31
an

$VDTHS,1.0,S*21
$PFEC,GPhve,0.000,A*3F
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
m

$GPGLL,3637.7560,N,13448.7015,E,000120.90,D,D*6F
$VDVTG,72.8,T,,M,2.3,N,4.3,K,D*36
jk

$VDVBW,,,V,0.72,2.19,A,,V,2.19,A*4A
$PFEC,ds060,D,C,TMC,G*07
sl

$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44

5-16
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

SDME_ NMEA ver1.5)


$GPRMC,000254,A,3500.834,N,13507.686,E,2.3,260.2,011113,,*1B
$VDVLW,,N,,N
$VDZDA,000254,01,11,2013,00
$VDHDT,1.0,T
$VDDTM,W84,,00.000,N,00.000,E,,W84
$PFEC,GPhve,0.000,A*3F
$GPGLL,3500.747,N,13507.264,E
$GPGGA,000255,3500.720,N,13507.123,E,1,06,0.7,1.0,M,23.0,M
$VDVTG,261.0,T,,M,2.3,N,4.3,K

36
$VDVBW,,,V,-0.40,-2.26,A
$PFEC,ds060,D,C,TMC,G*07
$GPGNS,000255,3500.666,N,13506.840,E,D,06,0.7,1.0,23.0,,

11
$PFEC,GPatt,1.0,9.5,0.0*45
$GPRMC,000255,A,3500.567,N,13506.274,E,2.3,262.2,011113,,*1B
$VDVLW,,N,,N

27
$VDZDA,000255,01,11,2013,00
$VDHDT,1.0,T
$VDDTM,W84,,00.000,N,00.000,E,,W84
02
$PFEC,GPhve,0.000,A*3F
$GPGLL,3500.499,N,13505.849,E
$GPGGA,000256,3500.478,N,13505.707,E,1,06,0.7,1.0,M,23.0,M
24

$VDVTG,263.0,T,,M,2.3,N,4.3,K
$VDVBW,,,V,-0.32,-2.28,A
$PFEC,ds060,D,C,TMC,G*07
20

$GPGNS,000256,3500.436,N,13505.423,E,D,06,0.7,1.0,23.0,,
$PFEC,GPatt,1.0,9.5,0.0*45
$GPRMC,000256,A,3500.379,N,13504.997,E,2.3,264.0,011113,,*11
an

$VDVLW,,N,,N
$VDZDA,000256,01,11,2013,00
$VDHDT,1.0,T
m

$VDDTM,W84,,00.000,N,00.000,E,,W84
$PFEC,GPhve,0.000,A*3F
jk

$GPGLL,3500.327,N,13504.571,E
$VDVTG,264.8,T,,M,2.3,N,4.3,K
sl

$VDVBW,,,V,-0.25,-2.29,A

5-17
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

SDME_ NMEA Ver2.0)


$PFEC,GPatt,1.0,9.7,0.0*47
$GPRMC,000222.60,A,3536.3015,N,13539.7884,E,2.3,196.0,011113,,*31
$VDVLW,,N,,N*5F
$VDZDA,000222.75,01,11,2013,00,00*62
$VDHDT,1.0,T*31
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$PFEC,GPhve,0.000,A*3F
$GPGLL,3535.7992,N,13539.6731,E,000222.90,D*01
$VDVTG,196.8,T,,M,2.3,N,4.3,K*65

36
$VDVBW,,,V,-2.21,-0.63,A*42
$PFEC,ds060,D,C,TMC,G*07
$GPGGA,000223.00,3535.6321,N,13539.6337,E,2,06,0.7,1.0,M,23.0,M,,*67

11
$VDROT,6.0,A*32
$GPGNS,000223.20,3535.1318,N,13539.5126,E,D,06,0.7,1.0,23.0,,*04
$PFEC,GPatt,1.0,9.7,0.0*47

27
$GPRMC,000223.60,A,3534.6332,N,13539.3873,E,2.3,198.0,011113,,*33
$VDVLW,,N,,N*5F
$VDZDA,000223.75,01,11,2013,00,00*63
02
$VDHDT,1.0,T*31
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
$PFEC,GPhve,0.000,A*3F
24

$GPGLL,3534.1363,N,13539.2576,E,000223.90,D*06
$VDVTG,198.8,T,,M,2.3,N,4.3,K*6B
$VDVBW,,,V,-2.19,-0.70,A*4B
20

$PFEC,ds060,D,C,TMC,G*07
$GPGGA,000224.00,3533.9710,N,13539.2134,E,2,06,0.7,1.0,M,23.0,M,,*6A
$VDROT,6.0,A*32
an

$GPGNS,000224.20,3533.4764,N,13539.0781,E,D,06,0.7,1.0,23.0,,*01
$PFEC,GPatt,1.0,9.7,0.0*47
$GPRMC,000224.60,A,3532.9837,N,13538.9385,E,2.3,200.0,011113,,*38
m

$VDVLW,,N,,N*5F
$VDZDA,000224.75,01,11,2013,00,00*64
jk

$VDHDT,1.0,T*31
$VDDTM,W84,,00.0000,N,00.0000,E,,W84*44
sl

$PFEC,GPhve,0.000,A*3F

5-18
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

Example of output sentence when device mode is THD

THD_ IEC ed.3)


$HEROT,6.0,A*2D
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGNS,000501.20,3612.5727,N,13536.7796,E,D,06,0.7,1.0,23.0,,*09
$HETHS,0.9,S*36
$PFEC,GPatt,0.9,8.6,0.0*4F
$GPRMC,000501.60,A,3611.9466,N,13537.0333,E,2.3,154.2,011113,,,D*51
$HEVLW,,N,,N,14034.750,N,0.000,N*40

36
$HEZDA,000501.75,01,11,2013,00,00*7B
$HEHDT,0.9,T*26
$PFEC,GPhve,0.000,A*3F

11
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGLL,3611.4742,N,13537.2189,E,000501.90,D,D*65
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B

27
$GPGGA,000502.00,3611.3162,N,13537.2799,E,2,06,0.7,1.0,M,23.0,M,,*6C
$HEVTG,155.0,T,,M,2.3,N,4.3,K,D*15
$HEVBW,,,V,-2.07,1.00,A,,V,1.00,A*78
02
$PFEC,ds060,D,C,TMC,G*07
$HEROT,6.0,A*2D
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
24

$GPGNS,000502.20,3610.9995,N,13537.4006,E,D,06,0.7,1.0,23.0,,*0F
$HETHS,0.9,S*36
$PFEC,GPatt,0.9,8.6,0.0*4F
20

$GPRMC,000502.60,A,3610.3629,N,13537.6367,E,2.3,156.2,011113,,,D*55
$HEVLW,,N,,N,14034.750,N,0.000,N*40
$HEZDA,000502.75,01,11,2013,00,00*78
an

$HEHDT,0.9,T*26
$PFEC,GPhve,0.000,A*3F
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
m

$GPGLL,3609.8830,N,13537.8091,E,000502.90,D,D*6B
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
jk

$GPGGA,000503.00,3609.7225,N,13537.8657,E,2,06,0.7,1.0,M,23.0,M,,*69
$HEVTG,157.0,T,,M,2.3,N,4.3,K,D*17
sl

$HEVBW,,,V,-2.10,0.93,A,,V,0.93,A*7E
$PFEC,ds060,D,C,TMC,G*07

5-19
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

THD_ IEC ed.4)


$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGGA,000437.00,3638.4656,N,13511.0861,E,2,06,0.7,1.0,M,23.0,M,,*69
$HEVTG,105.0,T,,M,2.3,N,4.3,K,D*10
$HEVBW,,,V,-0.56,2.23,A,,V,2.23,A*7E
$PFEC,ds060,D,C,TMC,G*07
$HEROT,6.0,A*2D
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGNS,000437.20,3638.3742,N,13511.3566,E,D,06,0.7,1.0,23.0,,,S*73
$HETHS,0.9,S*36

36
$PFEC,GPatt,0.9,8.9,0.0*40
$GPRMC,000437.60,A,3638.2327,N,13511.7614,E,2.3,106.0,011113,,,D,V*2B
$HEHRM,0.0,,0.0,0.0,A*19

11
$HEVLW,,N,,N,14034.750,N,0.000,N*40
$HEZDA,000437.75,01,11,2013,00,00*7F
$HEHDT,0.9,T*26

27
$PFEC,GPhve,0.000,A*3F
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGLL,3638.0860,N,13512.1651,E,000437.90,D,D*67
02
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGGA,000438.00,3637.9852,N,13512.4335,E,2,06,0.7,1.0,M,23.0,M,,*63
$HEVTG,107.0,T,,M,2.3,N,4.3,K,D*12
24

$HEVBW,,,V,-0.64,2.21,A,,V,2.21,A*7F
$PFEC,ds060,D,C,TMC,G*07
$HEROT,6.0,A*2D
20

$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$GPGNS,000438.20,3637.8821,N,13512.7014,E,D,06,0.7,1.0,23.0,,,S*75
$HETHS,0.9,S*36
an

$PFEC,GPatt,0.9,8.8,0.0*41
$GPRMC,000438.60,A,3637.6690,N,13513.2354,E,2.3,108.2,011113,,,D,V*2C
$HEHRM,0.0,,0.0,0.0,A*19
m

$HEVLW,,N,,N,14034.750,N,0.000,N*40
$HEZDA,000438.75,01,11,2013,00,00*70
jk

$HEHDT,0.9,T*26
$PFEC,GPhve,0.000,A*3F
sl

$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B

5-20
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

THD_ NMEA Ver1.5)


$GPGNS,000550,3502.828,N,13513.774,E,D,06,0.7,1.0,23.0,,
$PFEC,GPatt,0.8,8.2,0.0*4A
$GPRMC,000550,A,3502.663,N,13513.367,E,2.3,252.0,011113,,*1A
$HEVLW,,N,,N
$HEZDA,000550,01,11,2013,00
$HEHDT,0.8,T
$PFEC,GPhve,0.000,A*3F
$GPGLL,3502.504,N,13512.959,E
$HEDTM,W84,,00.000,N,00.000,E,,W84

36
$HEVTG,252.8,T,,M,2.3,N,4.3,K
$HEVBW,,,V,-0.71,-2.19,A
$PFEC,ds060,D,C,TMC,G*07

11
$GPGGA,000551,3502.453,N,13512.823,E,1,06,0.7,1.0,M,23.0,M
$GPGNS,000551,3502.301,N,13512.413,E,D,06,0.7,1.0,23.0,,
$PFEC,GPatt,0.8,8.2,0.0*4A

27
$GPRMC,000551,A,3502.106,N,13511.865,E,2.3,254.2,011113,,*10
$HEVLW,,N,,N
$HEZDA,000551,01,11,2013,00
02
$HEHDT,0.8,T
$PFEC,GPhve,0.000,A*3F
$GPGLL,3501.966,N,13511.452,E
24

$HEDTM,W84,,00.000,N,00.000,E,,W84
$GPGGA,000552,3501.921,N,13511.314,E,1,06,0.7,1.0,M,23.0,M
$HEVTG,255.0,T,,M,2.3,N,4.3,K
20

$HEVBW,,,V,-0.63,-2.21,A
$PFEC,ds060,D,C,TMC,G*07
$GPGNS,000552,3501.832,N,13511.038,E,D,06,0.7,1.0,23.0,,
an

$PFEC,GPatt,0.8,8.2,0.0*4A
$GPRMC,000552,A,3501.703,N,13510.623,E,2.3,256.0,011113,,*1E
$HEVLW,,N,,N
m

$HEZDA,000552,01,11,2013,00
$HEHDT,0.8,T
jk

$PFEC,GPhve,0.000,A*3F
$GPGLL,3501.539,N,13510.068,E
sl

$HEDTM,W84,,00.000,N,00.000,E,,W84

5-21
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Chapter 5 Maintenance

THD_ NMEA Ver2.0)


$GPRMC,000525.60,A,3531.4700,N,13538.4434,E,2.3,202.0,011113,,*39
$HEVLW,,N,,N*40
$HEZDA,000525.76,01,11,2013,00,00*7E
$HEHDT,0.8,T*27
$PFEC,GPhve,0.000,A*3F
$GPGLL,3530.9857,N,13538.2855,E,000525.90,D*0A
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
$HEVTG,202.8,T,,M,2.3,N,4.3,K*74
$HEVBW,,,V,-2.13,-0.86,A*57

36
$PFEC,ds060,D,C,TMC,G*07
$GPGGA,000526.00,3530.8248,N,13538.2320,E,2,06,0.7,1.0,M,23.0,M,,*63
$HEROT,6.0,A*2D

11
$GPGNS,000526.20,3530.3434,N,13538.0686,E,D,06,0.7,1.0,23.0,,*01
$PFEC,GPatt,0.8,8.4,0.0*4C
$GPRMC,000526.60,A,3529.7049,N,13537.8442,E,2.3,204.2,011113,,*3C

27
$HEVLW,,N,,N*40
$HEZDA,000526.76,01,11,2013,00,00*7D
$HEHDT,0.8,T*27
02
$PFEC,GPhve,0.000,A*3F
$GPGLL,3529.2286,N,13537.6712,E,000526.90,D*0B
$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B
24

$GPGGA,000527.00,3529.0704,N,13537.6126,E,2,06,0.7,1.0,M,23.0,M,,*60
$HEVTG,205.0,T,,M,2.3,N,4.3,K*7B
$HEVBW,,,V,-2.10,-0.94,A*57
20

$PFEC,ds060,D,C,TMC,G*07
$HEROT,6.0,A*2D
$GPGNS,000527.20,3528.7546,N,13537.4940,E,D,06,0.7,1.0,23.0,,*07
an

$PFEC,GPatt,0.8,8.4,0.0*4C
$GPRMC,000527.60,A,3528.1264,N,13537.2514,E,2.3,206.2,011113,,*3D
$HEVLW,,N,,N*40
m

$HEZDA,000527.76,01,11,2013,00,00*7C
$HEHDT,0.8,T*27
jk

$PFEC,GPhve,0.000,A*3F
$GPGLL,3527.8138,N,13537.1275,E,000527.90,D*0B
sl

$HEDTM,W84,,00.0000,N,00.0000,E,,W84*5B

5-22
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons.
It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO.
Contents of Drawings
回路図目次

Name Type Dwg. No. Page


INTERCONNECTION DIAGRAM GS-100 C7279-C01-F D-1
SC-301/GS-1001 C7265-K01-A D-2
SCHEMATIC DIAGRAM
GS-1002 C7279-K01-A D-3
SC-30/GS-1002 C7265-G01-B D-4
GS-1002 (TABLETOP

36
C7279-G01-B D-5
MOUNT)
GS-1002 (FLUSH
OUTLINE DRAWING C7279-G02-B D-6
MOUNT F)

11
GS-1002 (FLUSH
C7279-G03-B D-7
MOUNT S)
GS-1003 C7279-G04-B D-8

DRAWING
GS-1001
GS-1002 27 C7265-E01-B
C7279-E01-A
D-9
D-10
02
GS-1003 C7279-E02-A D-11
24
20
an
m
jk
sl

D0-1
D-1
1 2 3 4

空中線部 *1
ANTENNA UNIT STP(CAT5) CABLE ネットワーク機器
GS-1001 (x7 PORTS) NETWORK EQUIPMENT
表示部 NETWORK *2

10
スイッチングHUB
DISPLAY UNIT 8 MOD-WPAS0001-030+,3m 8 3 NR203PF-VVS1.25
SWITCHING HUB 100-230VAC
GS-1002 または OR STP(CAT5) *1 HUB-100 *2 3.5m
MJ-A10SPF0015-150C/300C MJ-A10SPF0016-010C,1m 1φ,50/60Hz
15/30m,φ10 *1
A または OR DATA1 MJ-A6SPF0003 IV-1.25sq.
J3 MJ-A6SPF -050C,5m,φ6 JB *1 TB2
sl
ANT-DN18WAPVC-300/400/500, インラインターミネーター
30/40/50m,φ16 TD1-A 1 シロ WHT 1 TD1H 指示器
IN-LINE TERMINATOR P *1

RED
BLK
WHT
BLU
TD1-B 2 クロ BLK 2 TD1B DISPLAY UNIT
jk
80-580-0008,0.3m
IEC61162-1 RD1-H 3 キ YEL TTYC(Y)SLA-1 3 RD1A DS-600 *2 または 航法装置
P *3

アカ
クロ
シロ
アオ
RD1-C 4 ミドリ GRN 4 RD1B OR NAV EQUIPMENT

接続箱
m NC
FG
5
6 12-24VDC
*1
DPYC(Y)-1.5
TB1
1 +DC_H
DATA1ポート
のみ接続可
DATA1 PORT ONLY

1
2
3
4
5
JUNCTION BOX DATA2 2 -DC_C
MJ-A6SPF *2 航法装置
GS-1003 J4

TB4
MJ-A6SPF0003-050C,5m,φ6 NAV EQUIPMENT *1
TD2-A 1

NET-S
NET-C
NET-H
NET-L
P IV-1.25sq.

SHIELD
TB3 TD2-B 2 アラートマネジメントシステム
an
TB5 SHIELD 1 M12-05BFFM-060C,6m CAN RD2-H 3 AMS
5 P
1 SHIELD NET-S 2 アカ RED RD2-C 4 インターフェイスユニット
2 NET-S NET-C 3 クロ BLK NC 5 INTERFACE UNIT TB1 *1
3 NET-C NET-H TTYCSLA-1
4 シロ WHT FG 6 IF-2503 *2 TD1-A 7
*2
4 NET-H NET-L 5 アオ BLU DATA3 TD1-B 8
20
MJ-A6SPF0003
5 NET-L TB2 MJ-A3SPF0015-060C,6m POWER FG 9 *1
J5 MJ-A6SPF -050C,5m,φ6 TTYCSLA-1
*1 TB1 (+) 1 シロ WHT 1 (+) TD3-A 1 シロ WHT RD-A TD2-A 10
DPYC-1.5 P 航法装置
RADAR/PLOTTER

24VDC 1 (+) (-) 2 クロ BLK 2 (-) TD3-B 2 クロ BLK RD-B NAV EQUIPMENT TD2-B 11
B 2 (-) SHIELD 3 3 SHIELD MOB-H 3 キ YEL FG 12 *1
P NOT USED TTYCSLA-1
MOB-C 4 ミドリ GRN ALM1-C 18
24
NC 5 ALM1-NO 19
*1
IV-1.25sq. USB FG 6 ALM1-NC 20
4 *1
DATA4 *2 FG 21
ALM2-C 22 TTYCSLA-1
J6 MJ-A7SPF MJ-A7SPF0003-050C,5m,φ6.9 TB1
*1
02
100-115/ TD4-A 1 シロ WHT 1 RD-H ALM2-NO 23
P
220-230VAC DPYC-1.5 7 U AC/DC電源ユニット(+) 3 TD4-B 2 クロ BLK 2 RD-C ALM2-NC 24
1φ,50/60Hz 6 V AC/DC POWER (-) 2 IEC61162-1/2 RD4-H 3 キ YEL 3 FG FG 25 *1
P
ALARM SYSTEM

SUPPLY UNIT E 1 RD4-C 4 ミドリ GRN 4 TD-A ALM3-C 26 TTYCSLA-1


PR-240 *2
*1 NC 5 アカ RED 5 TD-B ALM3-NO 27
P *3
27
または OR IV-2sq. ISOGND 6 アオ BLU 6 FG ALM3-NC 28
FG 7 FG 29 *1
*1 *1 LOC-C 30 TTYCSLA-1Q
100/110/115/ TB1
*1 DPYC-1.5
220/230VAC DPYC-1.5 5 整流器 (+) 1 IV-1.25sq. 12-24VDC 34 V_IN(+) LOC-NO 31
1φ,50/60Hz 6 RECTIFIER (-) 2 17 V_IN(-) LOC-NC 32
11
PR-62 *2 E 3 FG 33
*1 REM-H 13
注記 IV-2sq. REM-C 14
FG 15
*1)造船所手配。
C NC 16
36
*2)オプション。
*1
*3)不使用線はまとめて絶縁する。 IV-1.25sq.
*4)AMS接続可ポート:DATA1/2/4。
DRAWN TITLE
NOTE 12/Jan/2017 T.YAMASAKI GS-100
CHECKED 名 称
*1: SHIPYARD SUPPLY. 12/Jan/2017 H.MAKI サテライトスピードログ
APPROVED
*2: OPTION. 12/Jan/2017 H.MAKI 相互結線図
*3: INSULATE UNUSED WIRES. SCALE MASS NAME
kg SATELLITE SPEED LOG
*4: AMS CONNECTION PORT: DATA1/2/4. DWG.No. REF.No.
C7279-C01- G 20-036-5701-3 INTERCONNECTION DIAGRAM
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-2

36
11
27
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-3

36
11
27
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-4

36
11
27

1/Sep/2014 H.MAKI
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-5

36
11
27

13/Feb/2014 H.MAKI
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-6

36
11
27

13/Feb/2014 H.MAKI
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-7

36
11
27

13/Feb/2014 H.MAKI
02
24
20
an
m
jk
sl

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-8

36
11
27
02
24
20
an
m
jk
sl

13/Feb/2014 H.MAKI

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-9
ケイコクラベル(1)
WARNING LABEL 1
クランプ 86-003-1011-3
CLAMP (100-236-233-10)
MN-2
MAINプリント
シールワッシャセット (000-133-980-10) シールドケース(ウエ) PRINTED CIRCUIT BOARD
SEAL WASHER SET SHIELD CASE(UPPER) カバークミヒン
×11 GS-1001/SC-30 20-030-1108-2 20P8193(LF) COVER ASSEMBLY
SC-30 (001-023-440-00)
(001-288-070-00) (100-340-222-10) SC-30
20P8193A(LF) (001-037-150-00)
各部品出荷単位には、シールワッシャーセットが GS-1001
1個同梱されます (001-287-850-00)

カバー(ウエ)
カクソクドセンサクミヒン COVER(UPPER)
カクソクドセンサクミヒンZ RATE SENSOR ASSEMBLY 20-030-1101-3
RATE SENSOR FOR Z-AXIS SC-30 (センサX3) +ナベコネジ
SC-30 (J5) (001-023-460-00) PAN HEAD SCREW
コウザイ (001-023-490-00)
GS-1001-A M3X6 C2700W MBNI2
INSTALLATION MATERIALS (000-163-430-10)
CP20-03502 エツジサドル
EDGE SADDLE パツキン
コネクタ(NMEA) カクソクドセンサクミヒンY EDS-2 GASKET

36
MINI/MICRO T-CONNECTOR RATE SENSOR FOR Y-AXIS (000-570-298-10) 20-030-1104-1
1 SC-30 (J4) ケーブル(クミヒン)
NC-050505-FMF-TS001 (100-340-181-10)
(001-023-480-00) センサトリツケカナグ COAXIAL CABLE ASSEMBLY
(000-160-507-10) S.FL2-2LP-T1-400RS
SENSOR FIXING PLATE
ロッカクナット 1シュ 20-030-1107-0 (000-166-881-10)

11
HEXAGONAL NUT
M10 SUS316L 8
(000-167-490-10)
+ナベセムスBK
バネザガネ カクソクドセンサクミヒンX WASHER HEAD SCREW *BK* カバー(シタ)
M2.6X5 C2700W MBNI2

27
SPRING WASHER RATE SENSOR FOR X-AXIS COVER(BOTTOM)
M10 SUS316L 4 SC-30 (J3) (000-163-508-10) 20-030-1102-3
GPSアンテナクミヒン
(000-167-389-10) (001-023-470-00) GPS ANTENNA ASSEMBLY
ヒラザガネ SC-30
FLAT WASHER (001-019-730-00)

02
M10 SUS316L 8
MAINプリント GPSケーブルオサエ
(000-167-416-10) GPS CABLE CLAMP
PRINTED CIRCUIT BOARD
コンベックス SC-30 20P8193(LF) 20-030-1116-0
CABLE TIE GS-1001 20P8193A(LF) (100-340-290-10)
3

24
CV-150N
ゴアテツクス
(000-162-186-10)
GORE-TEX
ビニールテープ +ナベセムスBK VFM-12300
VINYL TAPE WASHER HEAD SCREW *BK* (000-165-931-10)
1 M3X8 C2700W MBNI2

20
0.2X19X10000MM クロ only GS-1001-A
(000-172-691-10) (000-163-518-10)
コネクタパツキン(2)
ケーブル(クミヒン)MJ
ケーブルブッシュ CONNECTOR GASKET (2)
CABLE ASSEMBLY
CABLE RUBBER BUSH 14-054-1062-0
1 MJ-A10SPF0016-010C
(100-240-240-10)
20-030-1105-2
(100-340-192-10)
ブチルゴムテープ
SELF-BONDING TAPE
ヨビヒン
SC-30
an
+-ナベセムスA
ケーブル(クミヒン)MJ
CABLE ASSEMBLY
MJ-A10SRMD0001+R
(000-171-228-10) ケーブルトメカナグ
FURUNOマーク
FURUNO MARK
20-030-1112-1
(001-266-040-00)

1 SPARE PARTS (100-340-251-10)


NO.15 WASHER HEAD SCREW *A* CABLE FIXTURE シールワッシャ
m
SP20-01201
(000-174-646-10) M3X20 C2700W MBNI2 20-030-1113-0 SEAL WASHER
ヒューズ (000-163-160-10) ロッカクスリワリ セムスB SWS 4X9
GLASS TUBE FUSE ニツプロツカー ボウシンオサエイタ HEX.HEAD SLOT BOLT-B WASHER (000-166-874-10)
FGB0-A 125V 1A PBF 3 NIP LOCKER RUBBER PLATE M4X12 SUS304
jk

ロッカクアナツキ ボルト
(000-155-847-10) NPL-520V0 20-030-1111-0 (000-162-939-10) HEXAGONAL HEAD BOLT
(000-165-656-10) ゲルブツシユ (100-340-240-10) M4X12 SUS316L
GEL BUSH ラッカボウシバンド
コウザイ GS-1001-N コウザイ (000-166-908-10)
sl

A-1 SAFETY BELT


INSTALLATION MATERIALS INSTALLATION MATERIALS
(000-160-852-10) 20-030-1114-2 ヒラザガネ
CP20-03501 CP20-02901
FLAT WASHER
ロッカクナット 1シュ ケーブルブッシュ コネクタカバークミヒン コネクタカバー M10 SUS316L
HEXAGONAL NUT CABLE RUBBER BUSH CONNECTOR COVER COVER
M10 SUS316L 8 20-030-1105-2 1 SC-30 20-030-1103-1
(000-167-416-10)
(000-167-490-10) (100-340-192-10) (001-023-510-00) バネザガネ
SPRING WASHER
バネザガネ コンベックス M10 SUS316L
CABLE TIE シメツケボルト
SPRING WASHER キバンシヤーシ (000-167-389-10)
4 CV-150N 3 RADOME FIXING BOLT
M10 SUS316L PCB CHASSIS
(000-162-186-10) ワッシャ 20-030-1115-3 トリツケボルト
(000-167-389-10) 20-030-1106-1
WASHER (100-340-283-10) FIXING BOLT
ヒラザガネ ヒラザガネ (100-340-201-10)
20-030-1117-1 20-036-1011-0
FLAT WASHER FLAT WASHER (100-343-491-10) (100-388-230-10)
M10 SUS316L
8 M10 SUS316L 4
(000-167-416-10) (000-167-416-10)
MODEL SC-30
コンベックス バネザガネ
CABLE TIE SPRING WASHER GS-100
CV-150N 3 4
M10 SUS316L
(000-162-186-10) (000-167-389-10)
APPROVED CHECKED DRAWN UNIT SC-30 サテライトコンパス
ケーブルブッシュ ロツカクボルト SATELLITE COMPASS
CABLE RUBBER BUSH
1 HEXAGONAL HEAD BOLT
4 07 Nov.2014 05 Nov.2014 26 Sep.2014 GS-1001 空中線部
20-030-1105-2 M10X25 SUS316L ANTENNA UNIT
(100-340-192-10) (000-162-959-10)
W.Katsube T.Yoshida A.Yabuta DWG.NO. C7265-E01-B

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-10

コネクタ(クミヒン)
CONNECTOR ASSEMBLY
バックカバー
バネザガネ BACK COVER ASSEMBLY
SPRING WASHER GS-1002
LCD M4 SUS304 (001-321-360-00)
PCB(MAIN) J10 J1
NL6448BC18-01F (000-167-405-10)
20P8209(LF)
ミガキマルヒラザガネ
FLAT CABLE FLAT WASHER チョウボルト 2シュ
CN1 J14 SML2CD30X60BD8 PCB(PNL)
M4 SUS304 WING BOLT-2
(000-140-900-10) 20P8210(LF)
(000-167-455-10) M4X12 SUS304 ボウスイキャップ
FLAT CABLE (000-163-934-10) WATERPROOF CAP
SML2CD33X100AD6P.5S4 MJ-AC
(000-177-905-10) J11 J2 (000-154-498-10)
バックカバー
BACK COVER
20-072(6-5P) 20-036-2021-1
(001-244-400-00) ボウスイキャップ
CN2 WATERPROOF CAP
J12
CN3 GPSシャーシ MOD-WPRC+
GPS CHASSIS (000-167-173-10)
CONNECTOR ASSEMBLY 20-035-1042-1
PCB(CAN) PCB(CAN-FIL)

6
PH8-SH8X2-L130 J13 J1 J2 J2 (100-381-671-10)
20P8213 20P8218
(000-177-899-10)

13
20-073(7-7P) 20-074(4-4P) コテイイタ(N-2.5)
+バインドコネジ FIXING PLATE(N-2.5)
(001-265-390-00) (001-265-400-00)
BINDING HEAD SCREW 05-106-5583-1
MAINプリント M3X6 SWCH
PRINTED CIRCUIT BOARD (000-176-673-10)
20P8209A(LF) シールWツキバインドネジ

71
(001-320-390-00) BINDERHEAD SCREW
03-176-1601-0
CAN-FILプリント
(100-349-050-10)
PRINTED CIRCUIT BOARD
CANプリント 20P8218(LF)

22
PRINTED CIRCUIT BOARD (001-320-860-00)
20P8213(LF)
LCDクミヒン (001-320-820-00)
LCD ASSEMBLY
GP170

40
(001-321-290-00)

LCDコテイイタ2
LCD FIXING PLATE 2
20-035-1026-2 メインシャーシ

02
MAIN CHASSIS
LCD 20-035-1031-1
NL6448BC18-01F (100-381-611-10)

2
LCDコテイイタ1
LCD FIXING PLATE 1

パネルクミヒン
ラバーキーオサエイタ
RUBBER KEY CLAMPING PLATE
20-035-1014-1
(100-381-331-10)
an 20-035-1022-2

ケーブル(FPC)
FLAT CABLE
SML2CD33X100AD6P.5S4 ハンガークミヒン
PANEL ASSEMBLY
m
(000-177-905-10) BRACKET ASSEMBLY
GP170 GP170
(001-321-330-00) (001-321-300-00)
パネルパッキン
jk

PANEL GASKET コテイイタB(N-2.5)


20-035-1012-0 FIXING PLATE(N-2.5)
PNLプリント 20-035-1053-1
パネル (100-380-270-10)
sl

PRINTED CIRCUIT BOARD


PANEL
20P8210(LF)
20-035-1011-4
(001-320-340-00) ノブ(N-2.5)
ラバーキー
フィルター KNOB BOLT(N-2.5)
RUBBER KEY
FILTER 24-011-1017-2
20-036-2011-0 フゾクヒン
20-035-1021-0 (100-346-502-10)
E (100-388-270-10) ACCESSORIES ハンガー
FP20-01100 BRACKET
20-036-2012-0
J (100-388-280-10) フィルタークリーナー 20-035-1051-1
LCD CLEANING CLOTH
19-028-3125-2
1
(100-360-672-10)
ブザースポンジ
BUZZER SPONGE コウザイ
20-035-1017-0 INSTALLATION MATERIALS
ブザーシート
BUZZER SHEET
CP20-03401
MODEL GS-100
コンベックス
20-035-1015-1 CONVEX
CV-125N
1
(000-172-164-10)
+トラスタッピンネジ1シュ APPROVED CHECKED DRAWN UNIT GS-1002 表示部
USBボウスイキャップ
SELF-TAPPING SCREW
USB WATERPROOF CAP
03-177-2031-1
5X20 SUS304
4 07 Nov.2014 05 Nov.2014 26 Sep.2014 DISPLAY UNIT
(000-162-608-10)
(100-359-701-10)
W.Katsube T.Yoshida A.Yabuta DWG.NO. C7279-E01-A

CONFIDENTIAL (internal use only)


This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO
D-11

+バインドコネジ
BINDING HEAD SCREW カバー(アナログ)
M4X10 SUS304 COVER(ANALOG)
(000-162-666-10) 24-014-2022-1
(100-367-901-10)

ソウサレバー
OPERATING LEVER
236-331 ケースパッキン(アナログ)
(000-153-700-10) CASE GASKET(ANALOG)
24-014-2052-1
(100-367-961-10)

ケーブルクランプ
CABLE CLAMP
ACKN-10SP
(000-106-285-10)

36
+バインドコネジ ハイセンシール チョウナット 2シュ
BINDING HEAD SCREW WIRING LABEL WING NUT
M3X6 SWCH 20-036-3002-2 M4 SWRM

11
(000-176-673-10) (100-388-312-10) (000-169-556-10)
バネザガネ
SPRING WASHER
M4 C5191W MBNI2
(000-168-238-10)
ミガキヒラザガネ

27
FLAT WASHER
M4 C2680R MBNI2
TBプリント ロッカクナット 1シュ (000-168-235-10)
PRINTED CIRCUIT BOARD HEXAGONAL NUT 1 SYU
20P8221(LF) M4 C3604B MBNI2
02
(001-320-900-00) アッチャクタンシ (000-168-237-10)
バネザガネ
CRIMP-ON LUG SPRING WASHER
FV2-M4 M4 C5191W MBNI2
(000-157-229-10) ミガキヒラザガネ (000-168-238-10)
24

FLAT WASHER
M4 C2680R MBNI2
(000-168-235-10)
ケースパッキン(アナログ)
CASE GASKET(ANALOG)
20

24-014-2052-1
(100-367-961-10) +アプセットUIセムスB
ケース(アナログ) UPSET UI SCREW-B
CASE(ANALOG) M4X20 SUS304
24-014-2021-1 (000-163-756-10)
an

+バインドコネジ クランプオサエイタ2
(100-367-891-10)
BINDING HEAD SCREW CLAMP FIXING PLATE 2
M3X6 SWCH 24-014-2042-0
(000-176-673-10) (100-367-850-10)
クランプオサエイタ
m

CLAMP CLAMPING PLATE


20-036-3012-0
(100-388-330-10)
jk

クランプダイ
sl

CLAMP BASE
20-036-3011-1
(100-390-021-10)
ソトハハツキザガネ
コウザイ EXTERNAL TOOTH LOCK WASHER
INSTALLATION MATERIALS M4 C5191W MBNI2
CP20-03701 (000-168-312-10)
+トラスタッピンネジ1シュ +ナベコネジ
SELF TAPPING SCREW ヨビヒン PAN HEAD SCREW
4X20 SUS304 4 SPARE PARTS M4X20 C2700W MBNI2
(000-158-850-10) SP20-01501 (000-163-439-10)
コンベックス ヒューズ
CABLE TIE GLASS TUBE FUSE
CV-100N, 1 FGMB 125V 3A PBF 1
000-162-167-10) (000-157-481-10)

MODEL GS-100

APPROVED CHECKED DRAWN UNIT GS-1003 接続箱


07 Nov.2014 05 Nov.2014 29 Sep.2014 JUNCTION BOX
W.Katsube T.Yoshida A.Yabuta DWG.NO. C7279-E02-A
CONFIDENTIAL (internal use only)
This confidential document is used only by FURUNO authorized persons. It is strictly prohibited to reproduce the document in whole or in part without prior written permission of FURUNO