MEP

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


WHAT MEP STANDS FOR?
• M - Mechanical
• E - Electrical
• P - Plumbing

It is also known as
• ME
• MEPD

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


WHY MEP IS IMPORTANT ?

• Building – Human Body


• MEP – Similar to Organs

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ROLES / RESPONSIBILITIES OF A MEP QUANTITY
SURVEYOR
Pre Contract Stage
• Manage Tender process, review & analyze
• Production of a detailed BOQ for Tender
• Preparation of the various documents required to submit the
final quote

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ROLES / RESPONSIBILITIES OF A MEP QUANTITY
SURVEYOR
Post Contract Stage
• Assist in preparing the Interim PC’s based on the work completion
• Identifying the out of scope works and pricing for the same
• Advice on MEP issues to carryout Contract Administration
• Cost Control & Monitoring the project
• Subcontract Management

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ROLES / RESPONSIBILITIES OF A MEP QUANTITY
SURVEYOR
Liaise with various departments
• Queries
• Follow-up
• Clarifications
• Design changes / updates
• Any other discussions related to project

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MEP EQUIPMENT, APPARATUS /
APPLIANCES AND ACCESSORIES

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL
• HVAC – Heat Ventilation and Air Condition 6 Hrs
• Fire Fighting 3 Hrs
• LPG System – (Liquefied Petroleum Gas) 2 Hrs

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


PLUMPING
• Water Supply 3 Hrs
• Cold Water supply
• Hot Water supply
• Drainage 3 Hrs
• Waste
• Storm / Rain
• Sewage 3 Hrs
• Soil

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL
• Power 4 Hrs
• Lighting 2 Hrs
• Low current system 10 Hrs
• Telephone & Intercom
• Fire Alarm System
• CCTV
• Access Control
• SMATV
• Public Address
• Home Automation System

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Different Types of Air Conditioning


• Window A/C (0 – 3 Ton)
• Split A/C (0 – 3 Ton)
• Package unit (4 – 15 Ton)
• Cassette unit (4 – 15 Ton)
• Ceiling mounted unit (4 – 15 Ton)
• Central air condition system (21 Ton and more)

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Window A/C (0 – 3 Ton)

Windows air conditioners are one of the


most widely used types of air conditioners
because they are the simplest form of the
air conditioning systems. Window air
conditioner comprises of the rigid base on
which all the parts of the window air
conditioner are assembled. The base is
assembled inside the casing which is fitted
into the wall or the window of the room in
which the air conditioner is fitted.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Window A/C (0 – 3 Ton) – Components

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Split A/C (0 – 3 Ton)


The split air conditioner comprises of two parts:
the outdoor unit and the indoor unit. The outdoor
unit, fitted outside the room, houses components
like the compressor, condenser and expansion
valve. The indoor unit comprises the evaporator
or cooling coil and the cooling fan. For this unit
you don’t have to make any slot in the wall of
the room. Further, present day split units have
aesthetic appeal and do not take up as much
space as a window unit. A split air conditioner
can be used to cool one or two rooms.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Split A/C (0 – 3 Ton) – Components

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Package unit (4 – 20 Ton)


An HVAC designer will suggest this type of air conditioner if you
want to cool more than two rooms or a larger space at your
home or office. There are two possible arrangements with the
package unit. In the first one, all the components, namely the
compressor, condenser (which can be air cooled or water
cooled), expansion valve and evaporator are housed in a single
box. The cooled air is thrown by the high capacity blower, and it
flows through the ducts laid through various rooms. In the second
arrangement, the compressor and condenser are housed in one
casing. The compressed gas passes through individual units,
comprised of the expansion valve and cooling coil, located in
various rooms.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Package unit (4 – 20 Ton) – Components

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Cassette Unit (4 – 20 Ton)


The 4-Way Cassette is unobtrusive and flexible. It blends with any
room interior and offers the ideal solution for small commercial
applications where space is limited.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Ceiling mounted unit (4 – 20 Ton)


Unlike ceiling cassette' units which are placed within a false ceiling,
under ceiling AC units are usually mounted near a wall and just
below ceiling height.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air condition (21 Ton and more) with cooling towers
Central air conditioning is used for cooling big
buildings, houses, offices, entire hotels, gyms, movie
theaters, factories etc. If the whole building is to be
air conditioned, HVAC engineers find that putting
individual units in each of the rooms is very
expensive making this a better option. A central air
conditioning system is comprised of a huge
compressor that has the capacity to produce
hundreds of tons of air conditioning. Cooling big
halls, malls, huge spaces, galleries etc is usually only
feasible with central conditioning units.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) with cooling towers

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components

FAHU / AHU
- Outside

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components

FAHU / AHU
- Inside

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components

FAHU / AHU
- Diagram

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components

COOLING
TOWER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components DUCTS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components REFREGERENT


PIPE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components INSULATION

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components ALU CLAD FOR
DUCT

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components VCD

dampers regulate airflow through duct work by


opening and closing their blades
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components FD

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components NRD

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components MD

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components SOUND


ATTENUATOR

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components ACCESS


COVER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components AIR DIFFUSER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components AIR REGISTER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components LENEAR GRILL

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components ELECTROSTATIC


FILTER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components BELL MOUTH

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Central air Condition (21 Ton and more) - Components EXHAUST FAN

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition


AXIAL FAN
Central air Condition (21 Ton and more) - Components Cylindrical
case

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

HVAC – Heat Ventilation and Air Condition

Standards

• ASHRAE - American Society of Heating, Refrigerating and Air-


Conditioning Engineers
• SMACNA - Sheet Metal and Air Conditioning Contractors' National
Association

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL
• HVAC – Heat Ventilation and Air Condition
• Water Supply
• Cold Water supply
• Hot Water supply
• Drainage
• Sewage
• Waste
• Drain
• Fire Fighting
• LPG System – (Liquefied Petroleum Gas)
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

Water Supply

Cold Water Supply


• Supply & Distribution pipe network
• uPVC pipe
• PPR pipe
• PEX pipe
• Fixtures / Sanitary ware accessories
• Water Tank

• Pumps
• Booster pump
• Transfer pump
• Water Meter
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

Water Supply

Hot Water Supply


• Distribution pipe network
• Copper pipe
• PPR pipe
• PEX pipe

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components uPVC pipes

Pipes Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components

PPR COPPER PEX

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components Pipe sizes

Pipe Size (Imperial) Pipe Size (Metric Pipe Size (Imperial) Pipe Size (Metric
3/8” 10 mm 3” 80 mm
½” 15 mm 4” 100 mm
¾” 20 mm 5” 125 mm
1” 25 mm 6” 150 mm
1 ¼” 32 mm 8” 200 mm
1 ½” 40 mm
2” 50 mm
2 ½” 65 mm

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components PUMPS

x
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

Water Supply - Components WATER METER


AND CABINET
WATER METER WATER HEATER WATER HAMMER ARRESTER

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components WATER TANKS

PLASTIC WATER TANK FIBRE WATER TANK GRP PANELLED WATER TANK

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components VALVES

GATE VAVLE BALL VALVE CHECK VALVE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Water Supply - Components VALVES

FLOAT VAVLE ANGLE VALVE SOLENOID VALVE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL
• HVAC – Heat Ventilation and Air Condition
• Water Supply
• Cold Water supply
• Hot Water supply
• Drainage
• Sewage
• Waste
• Drain
• Fire Fighting
• LPG System – (Liquefied Petroleum Gas)
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

Drainage - Components uPVC pipes

Pipes Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components Pipe sizes

Pipe Size (Imperial) Pipe Size (Metric Pipe Size (Imperial) Pipe Size (Metric
1 ½” 40 mm 9” 225 mm
2” 50 mm 12” 300 mm
2 ½” 65 mm 15” 375 mm
3” 80 mm 18” 450 mm
4” 100 mm 24” 600 mm
5” 125 mm 36” 900 mm
6” 150 mm 42” 1050 mm
8” 200 mm 48” 1200 mm

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components PUMPS

USED AS ;

• SUBMERSIBLE PUMP
• SUMP PUMP
• SEWAGE PUMP
• DRAINAGE PUMP

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components RAIN WATER OUTLET

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components
RAIN WATER FREE VENT COWL CATCH BASIN
DISCHARGE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components
SAND TRAP FLOOR TRAP GREASE TRAP

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components
GULLEY TRAP CLEAN OUT BALCONY DRAIN

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components
CHANNEL DRAIN BALCONY DRAIN

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Drainage - Components MANHOLE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL
• HVAC – Heat Ventilation and Air Condition
• Water Supply
• Cold Water supply
• Hot Water supply
• Drainage
• Sewage
• Waste
• Drain
• Fire Fighting
• LPG System – (Liquefied Petroleum Gas)
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

Fire Fighting - Components Pipes

Hose reel / Cabinet Fire Blanket


Pipes

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components EXTINGUISHER

CO2 Dry Powder Form

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components EXTINGUISHER

Deluge System Foam Bladder

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components FM 200

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components


PRE ACTION

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components PUMP

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components SPRINKLERS

Downright Upright Wall mounted

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

Fire Fighting - Components VALVES

Zone Control Valve Auto air vent

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL
• HVAC – Heat Ventilation and Air Condition
• Water Supply
• Cold Water supply
• Hot Water supply
• Drainage
• Sewage
• Waste
• Drain
• Fire Fighting
• LPG System – (Liquefied Petroleum Gas)
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
MECHANICAL (CONT’D)

LPG System - Components TANKS

LPG Tank LPG Cylinders

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

LPG System - Components Pipes

Gas Distribution Pipe Gas On/off Switch

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

LPG System - Components Accessories

Gas Meter Gas Detector

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


MECHANICAL (CONT’D)

LPG System - Components Accessories

Gas control panel 2nd stage regulator

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL

• Power
• Lighting
• Low current system
• Telephone & Intercom
• Fire Alarm System
• CCTV
• Access Control
• SMATV
• Public Address
• Earthing System
• Lightning Protection System

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Transformer


What is meant by power transformer?

Power Transformer is an electrical device that converts inbound


electricity to a higher or lower value of voltage for specific purposes.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components
Capacitor bank UPS
Capacitor Bank is a
combination of
numerous capacitors
of similar rating that
are joined in parallel
or series with one
another to collect
electrical energy. The
resulting bank is then
used to counteract or
correct a power
factor lag or phase
shift in an AC power
supply.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
ELECTRICAL (CONT’D)

Power - Components LV Panel


What is a LV panel?

Low voltage panel is a component of an


electrical distribution system that divides
an electrical power feed into branch
circuits while providing a protective fuse
or circuit breaker for each circuit in a
common enclosure.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components LV Panel / Switch Gear / MDB

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components
SMDB DB
The MDB then feeds SMDBs Distribution Board is a
which are installed midway component of an electricity
through the power supply system that divides
distribution system at the electrical power feed
a point where the large into subsidiary circuits whilst
distribution cable providing a protective fuse
terminates and several or circuit breaker for each
smaller sub-circuits begin. circuit, in a common
These switchboards are enclosure. They receive their
larger than a final feed from the SMDB.
distribution board circuit
although they have similar
construction process.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components
MCC ATS
Motor Control Centers (MCC) is an Automatic Transfer Switch
assembly of one or more enclosed sections (ATS) is a device that
having a common power bus and automatically transfers a
principally containing motor control units. power supply from its
Also, MCC could include variable- primary source to a backup
frequency drives (VFD), programmable source when it senses a
controllers and metering. failure or an outage in the
primary source. When a
failure occurs in the primary
power system, the ATS
invokes a standby power
source such as an
uninterruptable power
supply.
MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com
ELECTRICAL (CONT’D)

Power - Components Cable Tray

Tray without cover Tray with cover

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Bus Bar


An electrical bus bar is defined as a conductor or a group of conductor used for collecting electric power from the
incoming feeders and distributes them to the outgoing feeders. In other words, it is a type of electrical junction in
which all the incoming and outgoing electrical current meets. Thus, the electrical bus bar collects the electric power at
one location.

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Cable & Wires


A wire is a single conductor(material most commonly being copper or aluminium) while cable is two or more insulated
wires wrapped in one jacket. Multiple conductors that have no insulation around would be classified as a single
conductor.

Wire Cable

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Power Accessories

Socket Outlet Spur Fused Outlet

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Power Accessories

DP Switch Push Bell

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Power Accessories


Flex Outlet Switches

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Light Accessories


Lights

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Power - Components Light Accessories


Lighting Control Panel

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Telephone & Intercom - Components


Telephone & Data Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Telephone & Intercom - Components


Data Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Fire Alarm Systems - Components


Fire Alarm Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Access Control Systems - Components


Access Control
Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

CCTV Systems - Components


CCTV Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

SMATV Systems - Components


SMATV Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Lightning Protection Systems - Components


Lightning Protection
Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Earthing Systems - Components


Earthing Accessories

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


ELECTRICAL (CONT’D)

Authorities

UAE QATAR
DEWA / SEWA / FEWA /ADEWA
DM
ETISALAT/DU
NAKHEEL

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


RATE ANALYSIS FOR MEP WORKS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


RATE ANALYSIS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


OBTAIN VENDER QUOTATIONS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


QUOTATIONS
• Send inquiry with required documents
• Follow-up
• Receive quotation

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


COMPARISSION SHEET

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


COMPARISION SHEET

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


INTERIM VALUATION

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


INTERIM VALUATION

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


INTERIM VALUATION

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


VARIATION PROCEDURE

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


TESTING & COMMISSIONING

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


SUPPLY OF SPARE PARTS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com


CLOSEOUT DOCUMENTS

MEP QUANTITY SURVEYING | HANDOUTS | NISWER M HANEEFA - BSc (QS) Com

You might also like