A B C D E F G H I J K L M N O P

NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE NOTED.
1 2. MATERIAL 1
W1
- BOLT : ASTM F1554 GRADE 36 WITH UNC-CLASS 2A THREADS

W1 W1 - PLATE WASHER , ANCHOR PLATE : ASTM F436 / ASTM A36


- HEAVY HEX NUTS : ASTM A563 GRADE A
STANDARD NUT(TYP.) STANDARD NUT(TYP.)

W1
3. UNLESS OTHERWISE SPECIFIED, ALL ANCHOR RODS, ANCHOR PLATES,
PLATE WASHER (W1XW1Xt1) PLATE WASHER (W1XW1Xt1)
WASHERS AND NUTS SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION

PROJECTION
AS PER ASTM F2329/F2329M.
2 2
4. BOLT LENGTH SHALL CONFORM TO THE SCHEDULE ON THIS DRAWING
a

a
t1

t1
TOP OF TOP OF HOLE (d1)
UNLESS OTHERWISE NOTED ON THE DESIGN DRAWINGS.
ROUGH CONC. ROUGH CONC. d1
5. COMPRESSIVE STRENGTH OF GROUT SHALL BE AS PER STANDARD
DWG. NO. 1050-STSTD-000001.

t1
BOLT LENGTH "H"
BOLT LENGTH "L"
6. 2 NUTS SHALL BE USED ON ANCHOR BOLTS FOR STRUCTURAL STEEL

h(2 NUTS ONLY)


PLATE WASHER DETAIL COLUMNS EXCEPT FOR MINOR STRUCTURES SUCH AS STAIRS, LADDERS
3 AND PLATFORMS UNLESS OTHERWISE NOTED ON DESIGN DRAWINGS. 3

d 7. THIS STANDARD SHALL BE APPLIED TO PIPE RACKS, EQUIPMENT


W2 STRUCTURES, SHELTERS, BUILDINGS, LOCAL STRUCTURES & PLATFORM.
d W2
R = 3d BOLT SUPPLIED BY EQUIPMENT VENDORS SHALL NOT APPLIED THIS
STANDARD UNLESS OTHERWISE NOTED.
SQ. ANC.

t2
5d

PLATE 8. ANCHOR BOLTS ON THIS STANDARD SHALL BE SUPPLIED BY CONSTRUCTION

W2
(W2XW2Xt2) CONTRACTOR.

b
4 4
9. THE ANCHOR BOLT DIAMETER SHALL BE NOT LESS THAN 20mm, EXCEPT
TACK WELD NUT TOP WHERE EQUIPMENT DATA SHEETS REQUIRE SMALL DIAMETER BOLTS AND
& BOLT AT THREE POINTS (TYP.)
HOLE (d2) FOR THE ANCHORAGE OF MISCELLANEOUS STEEL ITEMS SUCH AS LADDER
STANDARD NUT d2 SUPPORTS, SMALL PIPING SUPPORTS, STAIR STRINGERS.
(TYP.)
10. ANCHOR BOLT DESIGN SHALL COMPLY WITH ACI318M-14, CHAPTER-17.

t2
11. LATERAL FORCES CAN BE TRANSFERRED EQUALLY TO ALL ANCHOR RODS,
5 OR TO SELECTIVE ANCHOR RODS, BY USING A PLATE WASHER WELDED TO 5
TYPE "J" TYPE "H" SQ. ANC. PLATE DETAIL
THE BASE PLATE BETWEEN THE ANCHOR ROD NUT AND THE TOP OF BASE
PLATE. (IF NECESSARY)
12. PROJECTION OF ANCHOR BOLT SHALL BE CONSIDERED ABOVE TOP OF
CONCRETE.
STANDARD ANCHOR BOLT SCHEDULE
13. FOR GENERAL POST FOUNDATION INSTALLATION OF ANCHOR BOLTS,
REFER TO DETAILED DESIGN DRAWINGS FOR 'HILTI' OR SIMILAR
6 APPROVED CHEMICAL ANCHORS. 6
EMBEDDED EDGE
BOLT BOLT LENGTH THREAD LENGTH PLATE WASHER SQ. ANC. PLATE NUT ALLOWANCE PROJECTION 14. SCOPE OF ANCHOR BOLT
LENGTH DISTANCE
CASE STANDARD DWG FOR ANCHOR BOLT BY
DIA d TYPE "J" TYPE "H" a b W1 t1 d1 W2 t2 d2 N1 (ONE NUT) N2 (TWO NUT) h (TWO NUT) ONE NUT TWO NUT C(MIN.)
CASE I ANCHOR BOLT FOR STEEL STRUCTURE FDN ISSUED BY ARCH
16 400 90 45 10 18 55 260 100 100
CASE II ANCHOR BOLT FOR EQUIPMENT FDN (STATIONARY) ISSUED BY STATIC
20 645 100 50 60 10 22 65 10 22 75 455 140 150 CASE III ANCHOR BOLT FOR EQUIPMENT FDN (ROTATING) DEVELOPED BY VENDOR
7 7
24 720 115 50 70 10 26 65 10 26 90 515 155 150

30 780 130 50 80 12 33 90 12 33 110 555 175 165

36 1000 160 65 90 12 39 90 12 39 135 725 210 170

42 1160 180 65 110 16 45 115 16 45 155 865 230 180

48 1235 195 70 130 20 52 115 20 52 175 915 250 190


8 8
1 52 1335 200 75 140 25 56 115 25 56 190 1000 260 210

56 1400 220 75 150 25 60 115 25 60 200 1050 275 225


NUT ALLOWANCE

DISTANCE
9 50mm MIN. 9

NUMBER OF ANCHOR BOLT


PROJECTION*
(N1 / N2)

BASE PLATE
ANCHOR BOLT TYPE 1 17-JUL-2023 ISSUED FOR CONSTRUCTION J.S. LIM I.S. YIM J. LEE
0 23-MAR-2023 ISSUED FOR CONSTRUCTION J.S. LIM I.S. YIM J. LEE
BOLT DIAMETER (d) NUMBER OF NUTS TOP OF BASE PLATE
AA 12-JAN-2023 ISSUED FOR REVIEW J.S. LIM I.S. YIM J. LEE
TOP OF GROUT ::::::: :::: ::: :: :
::::: ::::: ::::: ::::: ::::: REV DATE DESCRIPTION PREP'D CHK'D APP'D
TOP OF ROUGH CONC. ::::: ::::: :::::
10 AB N-H-M24-155-600-(2) 10

BOLT LENGTH
CONTRACT NO.
SQ. ANC. PLATE
PROJECTION CW66327
(FOR TYPE - H)

RAS LAFFAN PETROCHEMICALS


11 Ras Laffan Petrochemicals Project 11
RLIC, Qatar
FORMAT FOR ANCHOR BOLT CALL OUT ON DRAWINGS PROJECTION DETAIL MINIMUM EDGE DISTANCE
DOCUMENT TITLE
PROJECTION* : GROUT THK. + BASE PLATE THK. + NUT ALLOWANCE
STANDARD DRAWING
ANCHOR BOLTS
12 CONTRACTOR DWG. NO. SCALE SHEET 12
SC7062-EQ2D-STD-1050-0007 NONE 01/01
DWG. NO. SIZE REV.
CONFIDENTIAL AND PROPRIETARY INFORMATION: SECL-CTCI JOINT VENTURE ("CONTRACTOR") HEREBY TRANSFERS TITLE TO THIS DRAWING TO RAS LAFFAN PETROCHEMICALS (“COMPANY”), IN ACCORDANCE WITH THE ETHYLENE EPC CONTRACT BETWEEN CONTRACTOR AND COMPANY. COMPANY HAS THE FREE AND UNRESTRICTED RIGHT TO USE THIS DRAWING WITHOUT REGARD TO ANY PATENTS OR COPYRIGHTS OWNED OR CONTROLLED BY CONTRACTOR. 1050-STSTD-000007

File Name :
THIS DOCUMENT IS NOT INTENDED OR REPRESENTED TO BE SUITABLE FOR ANY PURPOSE OTHER THAN AS SET FORTH IN THE EPC CONTRACT. CONTRACTOR SHALL NOT DISCLOSE THIS DOCUMENT TO OTHERS NOR USE THIS DOCUMENT FOR ANY PURPOSE OTHER THAN AS PROVIDED IN THE ETHYLENE EPC CONTRACT WITHOUT COMPANY'S PRIOR WRITTEN PERMISSION. A1 1