C-1550 Hydraulics - Rev0
C-1550 Hydraulics - Rev0
C-1550 Hydraulics - Rev0
HYDRAULIC ORIENTATION
Rev-00
Date: 17/05/2011
Subject to change without notice
OVERVIEW
Engine Power-unit
Hydraulic
Tank
Cone Lubrication
Tank & Pump
Power-unit Hydraulic
Controls
Danfoss PVG
Valve Bank Auxiliary Block
Transfer Conveyor
Pressure Switch
Geared Flow
Track Block Divider
Return Manifold
Variable Pump High
Pressure Filter
Ventable Relief
Side Conveyor & Pre Valve
Screen Solenoids
ENGINE AND DRIVE
CAT C15 ENGINE & PT TECH CLUTCH
AUX Drives
An arrangement of
internal cogs deliver
power to the auxiliary
drive points.
Crusher Drive
PT TECH CLUTCH
PT TECH CLUTCH OPERATION
Clutch Port
Clutch Pack
Engine Side
Pressure
Swash Plate Output
& Pump
Pressure
Bias Spring Control (PC)
Spool
Servo
Piston Load Sensing (LS)
Spool
30 Bar
Pressure
PUMP OPERATION 3
PUMP OPERATION Pump swash plate position with a function selected and LS feedback active – When
a function is selected, the LS spool detects a pressure drop on the 30 bar and allows the
bias spring to move the swash plate to pump more oil. The LS line feeds back the
operating pressure to the LS spool on the pump. The pump swash plate will keep adjusting
until it has generated 30BAR pressure difference again between the pump output and the
LS line.
Pump Output - 30 Bar
greater than LS line
Pressure
Tank
Load Sensing LS
PVG FUNCTION 1 & 2
PVG VALVE FUNCTIONS 1 & 2
The variable flow output is used to drive the feeder and the control lever /
feeder slide function. The variable flow reduces the amount of unwanted oil
Feeder Slide Solenoid
being pumped around the machine helping to reduce heat generation.
TRACKING AND PVG FUNCTION 3
PVG VALVE FUNCTION 3 & TRACKING
The 3rd PVG output is used for fast tracking. The system is set to
deliver maximum output and the oil is split equally through a geared
flow divider before entering the track control block.
Track Block
Tank Line
Tank line
210 BAR
Relief
The speed of the Pre Screen is set using a valve which is bolted on
the screen subframe. CT1 regulates the oil flow to 67LPM driving the
screen at 1200RPM.
CT2 acts as an anti-cavitation valve should the screen overrun or
the oil supply is blocked when the screen is running.
Flow Regulator
PT TECH CLUTCH CONTROL
CLUTCH CONTROL
Control
Block
Oil Cooler
Tank
Pressure Filter
CLUTCH CONTROL PIPING
CLUTCH CONTROL PIPING
CLUTCH CTRL SOLENOIDS & SENSORS
CLUTCH CONTROL BLOCK
Proportional Solenoid
On / Off Solenoid
Temperature
Switch
With the engine running oil is pumped continuously into the clutch
control block from the single 20cc fixed displacement pump. This
steady supply of oil is being used to lubricate the clutch.
Drain Connection
Pressure Connection
Return Connection
Loop Pipe
AUXILIARY HYDRAULICS
AUXILIARY BLOCK LAYOUT
Tank
Suction Lines:
Gear Pumps
Suction Line:
Tank Breather Drain Lines Variable Pump
AIR FILTER AND RETURN INDICATOR
Figure 1 Figure 2
When the cone is crushing at normal operating pressures, the control system is pressurized as shown in Figure 1.
If an un-crushable falls into the chamber and sends the pressure up to the pre-set Tramp Relief Pressure, 158
BAR, (shown in Figure 2) or you press the Tramp Test button, the solenoid valve will close and dump all
pressurized oil in the top side of the cylinders. But the cavity below the piston on each of the main chamber
cylinders requires extra oil to fill up, thus the suction pressure induced by the rams being ‘pulled’ up, opens the
check valve sucks oil in directly from the tank.
CONE CLAMP CYLINDERS CHECK VALVE
Cone Clamping
Cylinder Suction Check
Valve
Cone Control
Block Tank
Return
CONE HYDRAULIC CONTROL CIRCUIT
1) Crushing Pressure Gauge
CONE CONTROL BLOCK
2) Raise / Lower Solenoid
3) Crushing Pressure Transducer
4) Tramp Relieve Solenoid
1 2 3 4 5 6 7 8
5) Dumpy Jack Pressure Transducer
6) Normally Open (N/O) Needle Valve
7) Incoming Oil Pressure Gauge
8) Dumpy Jack Pressure Gauge
9) Normally Closed (N/C) Needle
Valve
C-1550 Main Control
Cabinet 10) Filter - Tramp Relief Cylinder
Return
11) Dumpy Jack Relief
12) Incoming Relief (not shown)
13) Filter – Incoming Oil
14) Pressure Reducing Valve – Raise
/ Lower
14 15 9 10 11 12 13 15) Pressure Reducing Valve –
Dumpy Jack
CONE HYDRAULIC CONTROL CIRCUIT
STICKER LOCATION AND MEANING CHARGE PRESSURE
CRUSHING PRESSURE
Dumpy
Jacks
Supply
166 Bar
171
Bar
• Normally Open, NO, Needle Valve for the Dumpy Jacks’ Circuit
• Pressure Transducer, for the Dumpy Jack Circuit. This pressure signal is being constantly fed to the
PLC – If the pressure drops to 120 BAR, then the circuit will automatically be recharged & if the
pressure drops to 82 BAR, for 30 secs, then the crusher will be shut down due to ‘Low Dumpy Jack
Pressure’.
• Normally Closed, NC, Needle Valve for the Dumpy Jacks’ Circuit – used to manually dump all
pressure out of the circuit i.e. When removing the upper frame for maintenance etc.
• Dumpy Jacks’ Circuit Pressure Gauge
CONE HYDRAULIC CONTROL CIRCUIT
SHUTOFF VALVES
Three shutoff valves are fitted to the
outputs of the cone control block.
During testing these valves are closed to
set the pressures of the cone block.
If problems occur during operation they can
be closed to do troubleshooting to determine
if the problem is with the block or the
cylinders on the cone.
CONE LUBE OIL COMPONENTS
In-Line Filters:
Kobold Flow Meter: With Clog Indicator & By-
Pass Valve
The flow of the cone lubrication oil is constantly being
read by the PLC and if the flow is below 4 Lt/min when
the oil is below 30oC, or below 8 Lt/min when the oil is
above 31oC, you will not be able to operate the cone.
In-Line Filters:
With Clog Indicator & By-Pass Valve
When the filters are registering a large enough
restriction, pressure drop across the filters, the cone
will be stopped by the PLC.
CONE LUBE SCHEMATIC
LUBE COMPONENTS
Lube oil suction filter #(15) changed at 1st 500Hrs then every 1000Hrs. 3) Lube Oil Supply Line
4) Lube Oil Tank
Lube oil pressure filters x2 changed at 1st 100Hrs and then every 500 Hrs.
5) Tank Level Indicator
1 9 10 11 12
6) Lube Pump Low Pressure Relief
2 Valve 5 BAR
7) Lube Pump High Pressure Relief
3 Valve 25 BAR
8) Drain Port
4 9) Level Indicator
10) Breathable Filler Cap
5
11) Bulls Eye Level Gauge
13
12) Lube Oil Return Line (gravity
6
14 return)
13) Lube Oil Temperature Transducer
7
15 14) Tank Sediment Tray
8 15) Lube Oil Suction Strainer
TANK ASSEMBLY - EXTERNAL
Solenoid
Tank
Sediment 25 BAR High Pressure
Tray Relief
TANK ASSEMBLY - INTERNAL
LUBE TANK SUCTION STRAINER
The lube oil suction strainer is 90 micro and should be 1st changed at 500 Hrs then every 1000 Hrs.
5 BAR
LUBE OIL COOLER & PRESSURE GUAGE