SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM

SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

FC16 - <offline>
"FCcepl_greas_pump"
Name: Family:
Author: Version: 0.1
Block version: 2
Time stamp Code: 11/21/2013 02:33:49 PM
Interface: 09/30/2006 10:41:48 AM
Lengths (block/logic/data): 00798 00662 00002

Name Data Type Address Comment


IN 0.0
OUT 0.0
IN_OUT 0.0
TEMP 0.0
RETURN 0.0
RET_VAL 0.0

Block: FC16

Network: 1 Greas&Ceplatyn intial start during mixer start

M11.2
Greas&Cepl T26
atyn G & C
intial pump
M11.1 start start
Pedge during during
M22.2 Mixer mixer Intial
Rotor+Pan Start start start up
RC Intial "m11.2" "T26"
"m22.2" "m11.1" SR S_ODT
P S Q S Q

T26 S5T#40S TV BI
G & C
pump R BCD
start
during
Intial
start up
"T26" R

Page 1 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 2 Calculation of greasing pulse time.

2340

Q1.2
Q1.3 Rotor I2.4 M22.2 M8.5
Pan Start I2.1 Start Pan drive Rotor+Pan M8.4 "AlarmGrea
"25M01Star Rotor RC "37M01Star RC RC "Alarmgrea singCntrlT M3.0
t" "37M01Rc" t" "25M01Rc" "m22.2" singRC" ime" "SEC_1"
#

DB1.DBW48 2.A
"timer".
GreasingPu
lseAct

M7.5
"GreasingC
ntrlTimeCo
ADD_I CMP >=I mplet"
EN ENO R
2.A DB1.DBW48 DB1.DBW48 MOVE
"timer". "timer". EN ENO
GreasingPu GreasingPu
IN1 OUT lseAct lseAct IN1 0 IN DB1.DBW48
"timer".
IN2 2340 IN2 GreasingPu
OUT lseAct

Network: 3 Calculation of greasing control time.

55

M22.2 M7.5 M8.5 M7.5


Rotor+Pan "GreasingC M8.4 "AlarmGrea "GreasingC
RC ntrlTimeCo "Alarmgrea singCntrlT M3.0 ntrlTimeCo
"m22.2" mplet" singRC" ime" "SEC_1" ADD_I CMP >=I mplet"
EN ENO S

DB1.DBW50 DB1.DBW50 DB1.DBW50


"timer". "timer". "timer".
GreasingCn GreasingCn GreasingCn
trlAct IN1 OUT trlAct trlAct IN1

1 IN2 55 IN2
I4.5
greasing
distributo
r
"89M01Rc" M6.7
N

Page 2 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 4

M7.5
"GreasingC
ntrlTimeCo
mplet" MOVE
EN ENO

0 IN DB1.DBW50
"timer".
GreasingCn
OUT trlAct

Network: 5 Greasing pump start

When Rotor starts the Greasing pump start.


When Greasing distributor ckt ok ("89S01_iOK") = 1
then Greasing pump stops running.

DB5.DBX1.3 Q1.5
M22.2 M7.5 GREASING M8.5 Grease
Rotor+Pan "GreasingC M8.4 OVERLOAD "AlarmGrea pump ON
RC ntrlTimeCo "Alarmgrea "alarms". singCntrlT "89M01Star
"m22.2" mplet" singRC" GREAS_OL ime" CMP >I t"

DB1.DBW50
"timer".
GreasingCn
trlAct IN1

0 IN2
T0 I1.5 DB5.DBX1.3
Control Greasing GREASING
Voltage ON start OVERLOAD
"tseE010CV "89M01BtnS "alarms".
" tart" GREAS_OL

M11.2
Greas&Cepl
atyn
intial
start
during
mixer
start
"m11.2"

Page 3 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 6 Alarm Greasing pump RC.

M21.1 Q1.5 T28 DB5.DBX1.4


M30.1: Grease I4.3 "DelayAlar M8.4 GREASING
M0.0 R201 Auto pump ON Hydraulic M8.4 mGresingRC "Alarmgrea RC
False Mode "89M01Star pump RC "Alarmgrea " singRC" "alarms".
"log0" "AutoMode" t" "17M01Rc" singRC" S_ODT SR GREAS_RC
S Q S Q

S5T#3S TV BI M20.1
Acknowledg
R BCD ement
disorder
"mAcknAlar
m" R

Network: 7 Greasing pump control time alarm.

DB5.DBX1.5
Q1.5 I4.5 T29 M8.5 GREASING
M22.2 Grease I4.3 greasing M8.5 "DelayAlar "AlarmGrea CKT OK
Rotor+Pan pump ON Hydraulic distributo "AlarmGrea mGreasCntr singCntrlT "alarms".
RC "89M01Star pump RC r singCntrlT iTime" ime" GREAS_CKT_
"m22.2" t" "17M01Rc" "89M01Rc" ime" S_ODT SR OK
S Q S Q

S5T#2M TV BI M20.1
Acknowledg
R BCD ement
disorder
"mAcknAlar
m" R

Network: 8 Grease OVERLOAD

M20.1 DB5.DBX1.3
Acknowledg GREASING
ement OVERLOAD
disorder "alarms".
"mAcknAlar GREAS_OL
m" RS
R Q

I4.4
Greasing
pump
overlaod
"89M01Mps" S

Network: 9

Page 4 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 10 Calculation of cyplattyn pulse time.

348/60=5.8min

M22.2 M8.2 M7.4


Rotor+Pan M8.1 "AlarmCypl "CyplatCnt
RC "AlarmCypl tControlTi M3.0 rlTimeComp
"m22.2" attynRC" me" "SEC_1" ADD_I CMP >=I lete"
EN ENO R

DB1.DBW44 DB1.DBW44 DB1.DBW44 MOVE


"timer". "timer". "timer". EN ENO
CyplattynP CyplattynP CyplattynP
ulseAct IN1 OUT ulseAct ulseAct IN1 0 IN DB1.DBW44
"timer".
1 IN2 348 IN2 CyplattynP
OUT ulseAct

Network: 11 Calculation of cyplattyn control time.

26 sec

M22.2 M7.4 M8.2 M7.4


Rotor+Pan "CyplatCnt "AlarmCypl "CyplatCnt
RC rlTimeComp tControlTi M3.0 rlTimeComp
"m22.2" lete" me" "SEC_1" ADD_I CMP >=I lete"
EN ENO S

DB1.DBW46 DB1.DBW46 DB1.DBW46


"timer". "timer". "timer".
CyplattynC CyplattynC CyplattynC
tnrlAct IN1 OUT tnrlAct tnrlAct IN1

1 IN2 26 IN2
I5.4
Ceplattyn
distributo
r
"88M01Rc" M6.6
N

Network: 12

M7.4
"CyplatCnt
rlTimeComp
lete" MOVE
EN ENO

0 IN DB1.DBW46
"timer".
CyplattynC
OUT tnrlAct

Page 5 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 13 Ceplettyn valve and pump start

When Rotor starts the Greasing pump and Ceplettyn pump start.
Valve Ceplettyn Circuit also starts with the Ceplettyn pump.

When Ceplettyn distributor ckt ok ("87S01_iOK")= 1 &


Greasing distributor ckt ok ("89S01_iOK") = 1
then Greasing pump and Ceplettyn pump stops running.

T52 Q2.7
M22.2 M8.2 M7.4 Delay Ceplattyn
Rotor+Pan M8.1 "AlarmCypl "CyplatCnt valve ON pump ON
RC "AlarmCypl tControlTi rlTimeComp "T52" "88M01Star
"m22.2" attynRC" me" lete" CMP >I S_ODT t"
S Q

DB1.DBW46 S5T#5S TV BI
"timer".
CyplattynC R BCD
tnrlAct IN1
Q3.0
0 IN2 Spray
valve ON
T0 I5.5 "88K01open
Control Ceplattyn "
Voltage ON start
"tseE010CV "88M01BtnS
" tart"

M11.2
Greas&Cepl
atyn
intial
start
during
mixer
start
"m11.2"

Network: 14 Cyplattyn pump control time alarm.

Q2.7 I5.4 T19 Q2.7 M8.2


M22.2 Ceplattyn Ceplattyn M8.2 "DelayAlar Ceplattyn "AlarmCypl
Rotor+Pan pump ON distributo "AlarmCypl mCypltCntr pump ON tControlTi
RC "88M01Star r tControlTi lTime" "88M01Star me"
"m22.2" t" "88M01Rc" me" S_ODT t" SR
S Q S Q

S5T#1M TV BI DB2.DBX0.6
Alarm
R BCD Fault
Reset
"WORKING".
flt_res R

Page 6 of 7
SIMATIC AU7020199_SRMPL_RV15\ 02/24/2016 07:44:24 PM
SIMATIC 300(1)\CPU 313C\...\FC16 - <offline>

Network: 15 CEPLETTYN CKT OK

Page 7 of 7