CASH VALVES CRYOGENIC VALVES AND CONTROLS

A broad range of pressure build regulators, pressure reducing valves, final line gas valves and combination
pressure build economizer valves for cryogenic service.

FEATURES

• Six models for pressure reducing or pressure


build-up service.
• Five models for back-pressure service on
economizer circuit.
• Three models for combined pressure building
and economizer functions.
• Low temperature cut-off valves.
• Two models for final line gas service.
• High purity regulating valves for pressure
reducing, back pressure and differential
services.
• All parts commercially cleaned for
cryogenic/oxygen service or high purity gas
compatibility.
• Complementary ‘Y’ pattern strainers reduce
maintenance costs.
• Cryogenic safety and shut-off valves also
available.

GENERAL APPLICATION TECHNICAL DATA

A variety of controls for cryogenic systems Materials: Bronze, brass and


including liquid and gas line-pressure build- stainless steel
up regulators, economizer (heat leak) back Sizes: ¼” to 2” (7 to 50 mm)
pressure valves, temperature safety valves, Connections: Threaded NPTF
combination valves, shut-off valves and final- (BSP optional on some
line/service-line regulators. models)
Max initial pressure: 650 psi (45.7 kg/cm2)

Temperature ranges
Standard range: +150° to -320°F
(339 to 78K)
High purity valves: + 400° to -425°F
(478 to 19K)

Emerson.com © 2019 Emerson. All Rights Reserved. VCTDS-00514-EN 21/09


CASH VALVES CRYOGENIC VALVES AND CONTROLS

LIQUID-GAS DISTRIBUTION SYSTEM SCHEMATIC DIAGRAM

A. Type SY-70C
B. Type B
*
C. Type A-32
Vaporizer inlet valve
Vapor D. Type E-55
Safety Rupture
valve disc Plugged opening E. Type LTC
Annular space G F. Type FR
safety relief Vent valve
** Full trycock G. Type C-776
valve Vaporizer
Liquid
Check
valve
Vapor press
Vapor
Economizer
back press
Safety regulator
valve
Liquid
Liquid line

level gauge
Vacuum gauge equalizer
F
Liquid

connection
Liquid
pressure Safety valve
Bottom fill Top line head
valve valve

Fill Vacuum pump


line Check Fill line connection
valve drain Pressure build-up
regulator

Safety valve E
Temperature
control liquid

Service line
pressure

Strainer C Bypass
A
Pressure
Liquid draw build-up coil
To customer

Liquid withdrawal Press build-up coil


valve inlet valve Service line
regulator Plugged
Liquid Vapor
opening

B D

* C-776 cryogenic safety relief valve - for additional information, write or call for data sheet VCTDS-00515.
** Shut-off valve - for additional information, see page 17.

OVERVIEW

Cryogenics - the science of materials at extremely low temperatures - has become increasingly
important to industry. One important aspect of this field is the liquification of normally gaseous
elements which are used widely throughout the industry, including:

Oxygen - used extensively in BOF furnaces in the steel industry, for metal cutting, as
a rocket fuel and in medicine.
Acetylene - widely used in welding.
Nitrogen - used in refrigeration systems, for metal degassing, in aerosol packaging
and in cryogenic surgery.
Hydrogen - used as a rocket propellant and in the production of several metals.
Argon - widely used in incandescent lamps and fluorescent tubes.
Helium - used for arc welding, in the manufacture of electron tubes and in
cryogenic research.
Carbon Dioxide - used in refrigeration, to make aerosol tanks and in fire fighting.
Other cryogenic fluids include liquefied natural gas, fluorine, krypton, neon, methane and ethane.

The extensive range of Cash valves and controls is suitable for use in all the major areas of
cryogenic converters, or ‘dewars’, which are either stationary or installed in over-the-road
transport vehicles.

2
CASH VALVES CRYOGENIC VALVES AND CONTROLS

THE PRESSURE BUILD-UP CIRCUIT

The build-up circuit in the converter maintains a pressure of approximately 25 psi (1.76 kg/cm2)
above that required to drive the liquid to the final vaporizer and a pressure differential of
approximately 25 psi (1.76 kg/cm2) or higher across the service line regulator. To do this, liquid is
drawn into the pressure build-up coil, where it is warmed by ambient air and vaporized. The gas
then passes through the pressure build-up regulator and into the top of the tank, where it begins
to build up pressure because expansion is limited by the fixed volume.
When this pressure reaches the pressure build-up regulator’s set point, the regulator cuts off,
stopping vaporization and pressure build-up. As liquid is forced from the tank to the final vaporizer,
pressure in the tank begins to drop and the pressure build-up regulator returns to operation.

The pressure build-up regulator may be located in the liquid line before the pressure build-up
coil. As it is now used for liquid rather than gas service, it may have a smaller orifice or be a
smaller-sized valve. Its operation is the same as that of a gas regulator with the exception that it
regulates the liquid flow before the pressure build-up coil rather than the gas flow after the coil.
When pressure in the tank drops, the liquid pressure build-up regulator opens, allowing liquid to
flow through the pressure build-up coil and vaporize.

Pressure build-up regulators are available for most cryogenic system applications. The Type A-32
is a small ¼” (8 mm) pressure build-up valve; the larger Type B, Type G-60 and Type E-55 can be
used for either liquid or gas.

The Type B is available in sizes from ¼” to 2" (8 mm to 50 mm), the G-60 from ¼” to 1½”
(8 mm to 40 mm) and the Type E-55 from 1¼” to 2" (32 mm to 50 mm).

A-32 PRESSURE REDUCING OR PRESSURE BUILD-UP SERVICE

Construction REDUCED PRESSURE RANGES


Brass forged body and spring chamber; bronze Maximum working pressure
trim and diaphragms; PTFE seat disc and psi (kg/sq cm)
diaphragm gasket; stainless steel pressure 2-25 (0.14-1.76)
spring. All parts are commercially cleaned for 15-65 (1.05-4.57)
cryogenic service. 40-100 (2.81-7.03)
50-150 (3.52-10.55)
Note: Also available in stainless steel and special 75-175 (5.27-12.30)
construction for hi-purity service. 100-250 (7.03-17.58)
Contact your sales representative. 200-400 (14.06-28.12)
300-600 (21.09-42.18)
Temperature rating: +150°F to -320°F
(339K to 78K)

Maximum initial pressure: 600 psi


(42.18 kg/cm2)

DIMENSIONS
Dimensions
Size A B C Shipping weight
C
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
¼ (8) 2¼ (57.15) 33/16 (80.96) ⅝ (15.88) 1⅛ (0.51)
A
⅜ (10) 2¼ (57.15) 33/16 (80.96) ⅝ (15.88) 1⅛ (0.51)

3
CASH VALVES CRYOGENIC VALVES AND CONTROLS

A-36 PRESSURE REDUCING OR PRESSURE BUILD-UP SERVICE

Construction
Brass forged body and bronze spring chamber; bronze trim and diaphragms; PTFE seat disc and
gaskets; stainless steel pressure spring. All parts are commercially cleaned for cryogenic service.

Note: Also available in stainless steel and special construction for hi-purity service.
Contact your sales representative.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum initial pressure: 600 psi (42.18 kg/cm2)

REDUCED PRESSURE RANGES


Maximum working ranges
psi (kg/sq cm)
10-30 (0.70-2.11)
20-50 (1.41-3.52)
40-80 (2.81-5.62)
75-150 (5.27-10.55)
B
100-250 (7.03-17.58)
High pressure construction only
200-400 14.06-28.12

DIMENSIONS
Dimensions C
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
A
⅜ (10) 27/16 (61.91) 4½ (114.30) 1 (25.40) 2½ (1.13)
⅜ (10) 27/16 (61.91) 4½ (114.30) 1 (25.40) 2½ (1.13)

A-401 PRESSURE REDUCING OR PRESSURE BUILD-UP SERVICE

Construction
Bronze body and bronze spring chamber; bronze trim and neoprene/nylon diaphragms; FKM seat
disc and gaskets; stainless steel pressure spring. All parts are commercially cleaned for
cryogenic service.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum initial pressure: 600 psi (42.18 kg/cm2)

REDUCED PRESSURE RANGES


Maximum working ranges
psi (kg/sq cm)
20 to 60 (1.41 to 4.22)
40 to 80 (2.81 to 5.62)
75 to 125 (5.27 to 8.79)
100 to 250 (7.03 to 17.58)
B
200 to 400 (14.06 to 28.12)
High pressure construction only
300 to 600 (21.09 to 42.18)

DIMENSIONS
Dimensions C
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
½ (15) 4 (101.6) 4.64 (117.80) 1.95 (49.6) 4½ (1.68) A

4
CASH VALVES CRYOGENIC VALVES AND CONTROLS

MODELS A36, A401 SELECTION GUIDE


Example: A36Z B C S Z S Z T H 01 − E 1
Model
A36Z A36 (Bronze body)
A36G A36 (SST body)
A401 A401
Size
B ⅜" (A36)
C ½” (A401)
Service
C Cyrogenic
F Final line gas (A401)
Body/connection style
S Side inlet/side outlet - straight thru NPT
B Side inlet/side outlet - straight thru BSPT
Spring chamber material
Z Bronze spring chamber
Spring chamber style
S Standard
V Vented
Diaphragm material
G 316 SST (A36)
T Neoprene w/ Teflon liner (A401 final line only)
Z Bronze
Seat material
T Teflon
V Viton (A401 final line only)
Pressure screw style
H Hex
Variations
01 Standard
Design revision
(-) Original design
Spring material
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Type 1 2 3 4 5 6 7
A36 10 - 30 20 - 50 40 - 80 75 - 150 100 - 250 200 - 400 300 - 600*
SST
A401 20 - 60 40 - 80 75 - 125 100 - 250 200 - 400 300 - 600 ----
* Only available for Bronze body.

5
CASH VALVES CRYOGENIC VALVES AND CONTROLS

B PRESSURE REDUCING OR PRESSURE BUILD-UP SERVICE

Construction
Bronze body, spring chamber, trim and diaphragms; PTFE seat and diaphragm gasket; stainless
steel pressure spring; stainless steel bolts and nuts; PTFE bottom-plug gasket; Monel® strainer
screen. All parts are commercially cleaned for cryogenic service. Also available with BSP threads.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum initial pressure: 400 psi (28.12 kg/cm2)

Note: Type B95 available in stainless steel construction ½" thru 1" (15 to 25 mm) size.

REDUCED PRESSURE RANGES


Valve size Maximum working ranges
Inches (mm) psi (kg/sq cm)
¼ (8) 10-30 (0.70-2.11)
25-100 (1.76-7.03)
50-200 (3.52-14.06)
100-250 (7.03-17.58)
⅜ (10) 10-50 (0.70-3.52)
40-150 (2.81-10.55)
100-250 (7.03-17.58)
½ (15) 10-30 (0.70-2.11)
20-75 (1.41-5.27)
25-125 (1.76-8.79)
100-200 (7.03-14.06)
150-250 (10.55-17.58)
¾ (20) 10-30 (0.70-2.11)
20-70 (1.41-4.92)
30-100 (2.11-7.03)
50-150 (3.52-10.55)
100-225 (7.03-15.82)
150-250 (10.55-17.58)
1 (25) 10-35 (0.70-2.46)
20-60 (1.41-4.22)
50-100 (3.52-7.03)
100-250 (7.03-17.58)
1¼ (32) 10-30 (0.70-2.11)
20-40 (1.41-2.81)
35-80 (2.46-5.62)
75-150 (5.27-10.55)
1½ (40) 10-30 (0.70-2.11)
20-40 (1.41-2.81)
35-80 (2.46-5.62)
75-150 (5.27-10.55)
2 (50) 5-20 (0.35-1.41)
10-50 (0.70-3.52)
20-100 (1.41-7.03)

DIMENSIONS B
Dimensions
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
¼ (8) 3 (76.2) 2⅞ (73.03) 1¾ (44.45) 3 (1.35)
⅜ (10) 3⅞ (98.43) 4⅛ (104.78) 1¾ (44.45) 5½ (2.47)
½ (15) 4½ (114.3) 4½ (114.3) 2⅛ (53.98) 8 (3.6)
C
¾ (20) 5⅛ (130.18) 4⅝ (117.48) 2⅛ (53.98) 10 (4.5)
1 (25) 5⅞ (149.23) 5⅜ (136.53) 2⅝ (66.68) 16 (7.2)
1¼ (32) 6¾ (171.45) 6⅛ (155.58) 2⅝ (66.68) 20 (9.0)
1½ (40) 6¾ (171.45) 6⅛ (155.58) 3¼ (82.55) 20 (9.0) A
2 (50) 9¼ (234.95) 8½ (215.9) 3½ (88.90) 37 (16.65)

6
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE B SELECTION GUIDE


Example B Z A C S S Z T S 01 − E 1
Model
B B valve
Material of construction
Z Bronze
Valve size
A ¼”
B ⅜”
C ½”
D ¾”
E 1”
F 1¼”
G 1½”
H 2”
Service
C Cryogenic
F Final line gas (O2 clean adder required)
Body style/connection style
S Side inlet/side outlet - straight thru w/ NPT connections
B Side inlet/side outlet - straight thru w/ BSPT connections
C Side inlet/side outlet - straight thru w/ copper tube connections (⅜" only)
Spring chamber style
S Standard
D w/ pressure screw cap and differential connection
Diaphragm material
B Buna-N (final line)
Z Bronze (cryo)
Seat material
B Buna-N (final line)
T Teflon (cryo)
Pressure screw style
S Standard
Variation
01 Standard
Design revision
(-) Indicates original design
Spring material
D Steel (final line gas)
E SST (cryo)
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Size 1 2 3 4 5 6
¼” 10 - 30 25 - 100 50 - 200 100 - 250 ---- ----
⅜" 10 - 50 40 - 150 100 - 250 ---- ---- ----
½” 10 - 30 20 - 75 25 - 125 100 - 200 150 - 250 ----
SST ¾” 10 - 30 20 - 70 30 - 100 50 - 150 100 - 225 150 - 250
1" 10 - 35 20 - 60 50 - 100 50 - 150 100 - 250 ----
1¼”, 1½” 10 - 30 20 - 40 35 - 80 75 - 150 ---- ----
2" 5 - 20 10 - 50 20 - 100 ---- ---- ----
¼” 2 - 25 20 - 60 30 - 100 50 - 150 ---- ----
⅜" 2 - 30 20 - 70 40 - 110 90 - 150 ---- ----
½” 2 - 30 10 - 50 30 - 125 50 - 150 ---- ----
Steel ¾” 2 - 20 10 - 35 30 - 75 50 - 110 105 - 150 ----
1" 2 - 20 10 - 45 20 - 60 55 - 100 90 - 150 ----
1¼”, 1½” 2 - 15 10 - 30 20 - 50 45 - 100 90 - 150 ----
2" 2 - 20 10 - 60 20 - 100 90 - 150 ---- ----

7
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE B95 SELECTION GUIDE


Example: B95 G C C S S G T S 01 - E 1
Model
B95 B95 valve
Material of construction
G 316 SST body and chamber
Valve size
C ½"
D ¾"
E 1"
Service
C Cryogenic
Body style/connection style
S Side inlet/side outlet - straight thru w/ NPT connections
Spring chamber style
S Standard
D w/ pressure screw cap and differential connection
Diaphragm material
G 316 SST (cryo)
Seat material
T Teflon (cryo)
Pressure screw style
S Standard
Variation
01 Standard
Design revision
(-) Indicates original design
Spring material
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring
Material Size 1 2 3 4 5 6 7
½” 10 - 30 20 - 75 25 - 125 100 - 200 150 - 250 250 - 400 200 - 600
SST ¾” 10 - 30 20 - 70 30 - 100 50 - 150 100 - 225 150 - 250 ----
1" 10 - 35 20 - 60 50 - 100 50 - 150 100 - 250 200 - 400 ----

8
CASH VALVES CRYOGENIC VALVES AND CONTROLS

G-60 PRESSURE REDUCING OR PRESSURE BUILD-UP SERVICE

Construction
Threaded ends; bronze body, spring chamber, diaphragms and trim; stainless steel pressure
spring and body seat; PTFE seat and gaskets; stainless steel bolts. Closing cap over screw
provided.
Also available with all system exposed internal parts in stainless steel. All parts are commercially
cleaned for cryogenic service. Also available with BSP threads.

Note: Also available in stainless steel and special construction for hi-purity service.
Contact your sales representative.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum initial pressure: 600 psi (42.18 kg/cm2)

REDUCED PRESSURE RANGES


Valve size Maximum working ranges
Inches (mm) psi (kg/sq cm)
¼&⅜ (8 & 10) 5-30 (0.35-2.11)
15-65 (1.05-4.57)
30-110 (2.11-7.73)
75-200 (5.27-14.06)
100-400* (7.03-28.12*)
100-600* (7.03-42.18*)
½ (15) 0-7 (0-0.49)
5-70 (0.35-4.92)
50-150 (3.52-10.55)
50-250 (3.52-17.58)
200-500 (14.06-35.16)
¾ (20) 0-10 (0-0.70)
5-75 (0.35-5.27)
50-200 (3.52-14.06)
100-600* (7.03-42.18)
1 (25) 10-50 (0.70-3.52)
50-200 (3.52-14.06)
100-600* (7.03-42.18)
1¼ & 1½ (32 & 40) 5-15 (0.35-1.05)
10-50 (0.70-3.52)
30-75 (2.11-5.27)
50-120 (3.52-8.44)
75-150 (5.27-10.55)
100-400* (7.03-28.12)

* Note: higher ranges are attained by modifying standard valve and/or using a different pressure spring.
Contact your sales representative.

DIMENSIONS
Dimensions
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
¼ (8) 4 (101.60) 6⅝ (168.28) 23/16 (55.55) 9 (4.05)
⅜ (10) 4 (101.60) 6⅝ (168.28) 23/16 (55.55) 9 (4.05) C
½ (15) 4¾ (120.65) 7⅝ (193.68) 25/16 (58.72) 16 (7.20)
¾ (20) 5⅝ (142.88) 10 (254.00) 2⅝ (66.68) 24 (10.80)
1 (25) 6½ (165.10) 10¾ (273.05) 2⅞ (73.03) 35 (15.75)
A
1¼ (32) 8 (203.20) 125/16 (312.74) 39/16 (90.49) 63 (28.35)
1½ (40) 8 (203.20) 125/16 (312.74) 39/16 (90.49) 63 (28.35)

9
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE G60 SELECTION GUIDE


Example: G60Z A W S S Z Z B H 00 - E 1
Model
G60Z G60 w/ bronze body
G60G G60 w/ 316 stainless steel body
Valve size
A ¼" E 1"
B ⅜" F 1¼"
C ½" G 1½"
D ¾"
Service
C Cryogenic service
F Final line gas (O2 clean but not used in cryo service)
Body/connection style
S Side inlet/side outlet - straight thru w/ NPT connections
Spring chamber style
S Standard
C w/ pressure screw cap
D w/ pressure screw cap and differential connection
V Vented
W Vented w/ pressure screw cap
Spring chamber material
Z Bronze
G 316 stainless steel
Diaphragm material
B Buna-N (final line gas)
Z Bronze (cryo)
G 316 stainless steel (cryo)
L Buna-N w/ Teflon liner (final line gas)
Seat material
T Teflon (cryo)
V Viton (final line gas)
Pressure screw style
S Standard
Variation
01 Standard (303 stainless steel trim)
(303 SST seat ring, 303 SST pusher post button, 303 SST pusher post, 303 SST guide bushing, 303 SST piston and 316 SST bottom cap)
31 Brass trim
(303 SST seat ring, brass pusher post button, brass pusher post, 303 SST guide bushing, brass piston and bronze bottom cap)
Design revision
(-) Indicates original design
Spring material
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Size 1 2 3 4 5 6
¼”, ⅜" 5 - 30 15 - 65 30 - 110 75 - 200 100 - 400 100 - 600
½” 0-7 5 - 70 50 - 150 50 - 250 100 - 400 200 - 500
SST ¾" 0 - 10 5 - 75 50 - 200 100 - 400 100 - 600 ----
1" 10 - 50 50 - 200 100 - 400 100 - 600 ---- ----
1¼", 1½" 5 - 15 10 - 50 30 - 75 50 - 120 75 - 120 100 - 400

10
CASH VALVES CRYOGENIC VALVES AND CONTROLS

E-55 PRESSURE REDUCING, PRESSURE BUILD-UP OR FINAL-LINE GAS SERVICE

Construction - for pressure reducing or pressure build-up service


Bronze body, spring chamber, trim; stainless steel body seat and pressure spring; PTFE seat,
O-rings and bottom plug gasket; Monel® diaphragms and strainer screen; stainless steel bolts.
All parts are commercially cleaned for cryogenic service. Also available with BSP threads.

Size range: 1¼", 1½", 2" (32, 40, 50 mm)


Temperature rating: +150°F to -320°F (339K to 78K)
Maximum initial pressure: 400 psi (28.12 kg/cm2)

Construction - for final-line gas service


Bronze body, spring chamber and trim; stainless steel body seat and pressure spring; FKM seat
disc and PTFE bottom plug gasket; FKM O-ring and neoprene diaphragm with FKM liner; Monel®
strainer screen. All parts are commercially cleaned for oxygen service. Also available with
BSP threads.

Size range: ½", ¾", 1", 1¼", 1½", 2" (15, 20, 25, 32, 40, 50 mm)
Temperature rating: +150°F to 0°F (339K to 255K)
Maximum initial pressure: 400 psi (28.12 kg/cm2)

Note: Specification for final-line gas service is not for use on cold gas or liquid (less than 0°F).

REDUCED PRESSURE RANGES


Valve size Maximum working ranges
Inches (mm) psi (kg/sq cm) C
½”, ¾”, 1” (15, 20, 25) 10-35 (0.70-2.46)
20-75 (1.41-5.27)
75-125 (5.27-8.79)
125-175 (8.79-12.30) A
75-250 (5.27-17.58)
1¼”, 1½”, 2” (32, 40, 50) 20-70 (1.41-4.92)
50-150 (3.52-10.55)
75-200 (5.27-14.06)
150-300 (10.55-21.09)

DIMENSIONS
Dimensions
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
½ (15) 4 (101.6) 7¼ (184.15) 2¼ (57.15) 6 (2.7)
¾ (20) 4 (101.6) 7¼ (184.15) 2¼ (57.15) 6 (2.7)
1 (25) 4 (101.6) 7¼ (184.15) 2¼ (57.15) 6 (2.7)
1¼ (32) 5⅝ (142.88) 11⅛ (282.58) 3¼ (82.55) 17 (7.7)
1½ (40) 5⅝ (142.88) 11⅛ (282.58) 3¼ (82.55) 17 (7.7)
2 (50) 5¾ (146.05) 11⅜ (288.93) 2⅞ (73.03) 17 (7.7)

11
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE E-55 SELECTION GUIDE


Example: E55 C C S G T 01 - E 1
Model
E55 E-55 valve w/ bronze body and spring chamber
Valve size
C ½" F 1¼"
D ¾" G 1½"
E 1" H 2"
Service
C Cryo (1¼" - 2")
F Final line gas (all sizes)
Body style/connection style
S Side inlet/side outlet - straight thru w/ NPT connections
B Side inlet/side outlet - straight thru w/ BSPT connections
C Side inlet/side outlet - straight thru w/ NPT connections (enlarged port) 1" E-55 only
D Side inlet/side outlet - straight thru w/ BSPT connections (enlarged port) 1" E-55 only
Diaphragm material
G 316 SST (cryo) (1¼" - 2")
N Neoprene w/ Viton diaphragm liner (final line gas)
L Neoprene w/ Teflon diaphragm liner (final line gas)
Seat material
T Teflon (cryo)
V Viton (final line gas)
Variation
01 Standard
Design revision
(-) Indicates original design
Spring material
E SST
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Size 1 2 3 4 5
½", ¾", 1" 10 - 35 20 - 75 75 - 125 125 - 175 75 - 250
SST
1¼", 1½", 2" 20 - 70 50 - 150 ---- 75 - 200 150 - 300

12
CASH VALVES CRYOGENIC VALVES AND CONTROLS

THE ECONOMIZER CIRCUIT

The economizer back pressure regulator is set from 10 to 25 psi (.70 to 1.76 kg/sq cm) above the
set pressure of the pressure build-up regulator. When no gas is being used and heat leakage in
the tank causes a gas pressure build-up, the excess pressure is by-passed into the final vaporizer
line to conserve gas rather than allow the safety valve in the pressure build-up circuit to relieve
the excess gas into the atmosphere.

Five types of back pressure valves are available for this circuit: the Type FRM, low flows,
max. 600 psi (42.18 kg/cm2); FRM-2, medium flows, max. 250 psi (17.58 kg/cm2); FRM-2 (HP) high
pressure, medium flows, max. 400 psi (28.12 kg/cm2); FR, large flows, max. 400 psi (28.12 kg/ cm2)
and the FR-6, max. 600 psi (42.18 kg/cm2).

FRM BACK PRESSURE OR ECONOMIZER SERVICE

Construction
Threaded ends; 2-way, side inlet-side outlet; 2-way, side inlet-bottom outlet; 3-way, 2 side inlets-
bottom outlet; forged bronze body; bronze diaphragms; stainless steel seat disc, seat ring and
pressure spring; PTFE diaphragm gasket. All parts commercially cleaned for cryogenic service.

Note: Also available in stainless steel and special construction for hi-purity service.
Contact your sales representative.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum set pressure: 600 psi (42.18 kg/cm2)

PRESSURE RANGES
Maximum working ranges
psi (kg/sq cm)
2-25 (0.14-1.76)
15-65 (1.05-4.57)
40-100 (2.81-7.03)
75-175 (5.27-12.30)
100-250 (7.03-17.58)
200-400 (14.06-28.12)
300-600 (21.09-42.18)

3⅜”
(85.73 mm)
DIMENSIONS
Size Shipping weight
Description inches (mm) lbs (kgs)
Side inlet, side outlet ¼ (8) 1⅛ (0.51)
Side inlet, side outlet ⅜ (10) 1⅛ (0.51)
Side inlet, bottom outlet ¼ (8) 1⅛ (0.51)
Side inlet, bottom outlet ⅜ (10) 1⅛ (0.51)
2 Side inlets, bottom outlet ¼ (8) 1⅛ (0.51)

* Use valve numbers for pressures to 175 psi only. Consult factory for other numbers. ½” 2¼”
(12.7 mm) (57.15 mm)

13
CASH VALVES CRYOGENIC VALVES AND CONTROLS

FRM-2, FRM-2 (HP) BACK PRESSURE OR ECONOMIZER SERVICE

Construction
Threaded ends; 2-way, side inlet-side outlet; 2-way, side inlet-bottom outlet; 3-way, 2 side inlets-
bottom outlet; forged bronze body; cast bronze spring chamber; stainless steel seat disc, seat
ring and pressure spring; bronze diaphragms; PTFE diaphragm gasket. All parts commercially
cleaned for cryogenic service.

Note: FRM-2 available in stainless steel and special construction for hi-purity service.
Contact your sales representative.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum set pressure
FRM-2: 250 psi (17.58 kg/cm2)
FRM-2HP: 400 psi (28.12 kg/cm2)

PRESSURE RANGES
Maximum working ranges
Size psi (kg/sq cm)
FRM-2
B
All sizes 0-30 (0-2.11)
All sizes 20-50 (1.41-3.52)
All sizes 40-80 (2.81-5.62)
All sizes 75-150 (5.27-10.55)
All sizes 100-275 (7.03-19.34)
FRM-2HP
All sizes 200-400 (14.06-28.12) C

DIMENSIONS
Dimensions
Size A B C Shipping weight
Description inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
FRM-2
Side inlet, side outlet ¼ (8) 211/16 (68.26) 4½ (114.3) ¾ (19.05) 2½ (1.13)
Side inlet, side outlet ⅜ (10) 211/16 (68.26) 4½ (114.3) ¾ (19.05) 2½ (1.13)
Side inlet, side outlet ½ (15) 2⅞ (73.03) 4½ (114.3) 1⅛ (28.58) 3½ (1.58)
Side inlet, bottom outlet ¼ (8) 211/16 (68.26) 4½ (114.3) ¾ (19.05 2½ (1.13)
Side inlet, bottom outlet ⅜ (10) 211/16 (68.26) 4½ (114.3) ¾ (19.05) 2½ (1.13)
Side inlet, bottom outlet ½ (15) 2⅞ (73.03) 4½ (114.3) 1⅛ (28.58) 3½ (1.58)
2 Side inlets, bottom outlet ¼ (8) 211/16 (68.26) 4½ (114.3) ¾ 19.05) 2½ (1.13)
2 Side inlets, bottom outlet ⅜ (10) 211/16 (68.26) 4½ (114.3) ¾ (19.05) 2½ (1.13)
2 Side inlets, bottom outlet ½ (15) 2⅞ (73.03) 4½ (114.3) 1⅛ (28.58) 3½ (1.58)
FRM-2HP
Side inlet, side outlet ¼ (8) 211/16 (68.26) 4½ (114.3) 25/32 (19.84) 2½ (1.13)
Side inlet, bottom outlet ¼ (8) 211/16 (68.26) 4½ (114.3) 25/32 (19.84) 2½ (1.13)
Side inlet, side outlet ⅜ (10) 211/16 (68.26) 4½ (114.3) 25/32 (19.84) 2½ (1.13)
Side inlet, bottom outlet ⅜ (10) 211/16 (68.26) 4½ (114.3) 25/32 (19.84) 2½ (1.13)
Side inlet, side outlet ½ (15) 211/16 (68.26) 4½ (114.3) 1⅛ (28.585) 3½ (1.58)
Side inlet, bottom outlet ½ (15) 211/16 (68.26) 4½ (114.3) 25/32 (19.84) 3½ (1.58)

14
CASH VALVES CRYOGENIC VALVES AND CONTROLS

FRM, FRM-2 SELECTION GUIDE


Example: FRM- A W Z S A S B F 02 − D 1
Model
FRM- FRM
FRM2 FRM-2
Size
A ¼” (all)
B ⅜” (all)
C ½” (FRM-2)
Service
C Cryogenic (FRM, FRM-2)
Material of construction
Z Brass
G 316 SST (FRM, FRM-2)
E 303 SST (FRM)
Body/connection style
S Side inlet/side outlet (all) NPT
R 2 side inlets/bottom outlet (FRM, FRM-2) NPT
E Side inlet/bottom outlet (FRM, FRM-2) NPT
B Side inlet/side outlet (BSPT)
P Side inlet/side outlet ¼” NPS - .082 wall pipe (FRM-2)
T Side inlet/side outlet ⅜” NPS - .035 wall pipe (FRM-2)
V Side inlet/side outlet ⅝" NPS - .049 wall pipe (FRM-2)
Spring chamber material
Z Brass spring chamber
G SST spring chamber (FRM-2)
C Chrome plated
Spring chamber style
S Standard
W Without vent hole
Diaphragm material
G 316 SST
Z Bronze
Pressure screw style
F Fillister (FRM only)
H Hex
T T-handle (FRM)
Variations
03 303 Stainless steel trim w/ Teflon diaphragm gasket (metal diaphragms only)
04 303 Stainless steel trim w/ 6 x 0.005 thick bronze diaphragms
05 303 Stainless steel trim w/ nylon inserted locknut
13 316 Stainless steel trim w/ Teflon diaphragm gasket (metal diaphragms only)
23 Monel trim w/ Teflon diaphragm gasket (metal diaphragms only)
32 Remote sensing
Design revision
(-) Original design
Spring material
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Model 1 2 3 4 5 6 7 8 9
FRM 2 - 25 15 - 65 40 - 100 50 - 150 75 - 175 100 - 250 200 - 400 200 - 600 300 - 600
SST
FRM-2 0 - 30 20 - 50 40 - 80 75 - 150 100 - 275 200 - 400 300 - 600 ---- ----

15
CASH VALVES CRYOGENIC VALVES AND CONTROLS

FR, FR-6 BACK PRESSURE OR ECONOMIZER SERVICE

Construction
Threaded ends; 3-way, 2 side inlets-bottom outlet; bronze body, spring chamber and diaphragms;
brass body seat; stainless steel seat disc, seat ring and pressure spring; PTFE O-ring and
diaphragm gasket; stainless steel bolts; pressure-tight closing cap. All parts are commercially
cleaned for cryogenic service. Also available with BSP threads.

FR Series valves are available in various pressure control and temperature ranges and are
designated as follows:
• Type FR has a bronze body as standard, is suitable for pressure of 0 to 400 psig (0 to 27.6 barg)
and maximum temperatures 200°F to 600°F (93°C to 316°C)*.
• Type FR-6 incorporates a diaphragm ring mounted above the diaphragm to accomodate
higher back pressure ranges: 200 to 600 psig (13.8-41 barg); 200°F to 600°F (93°C to 316°C)*.

Note: Also available in stainless steel and special construction for hi-purity systems.
Contact your sales representative.

Temperature rating: +150°F to -320°F (339K to 78K)

MAXIMUM INITIAL PRESSURE


Type psi kg/cm2
FR 250 17.58
FR-½” 400 28.12
FR-¾” 265 18.64
FR-1”-2” 250 17.58
FR-6 400 28.12 B
600 42.18 on ½”

Maximum set pressure: See below. For higher pressures, contact your sales representative.

DIMENSIONS
Dimensions
Size A B C Shipping weight
C
in. (mm) in. (mm) in. (mm) in. (mm) lbs (kgs)
½ (15) 4¾ (120.65) 6¾ (171.45) 1⅝ (41.28) 9½ (4.27)
¾ (20) 5⅝ (142.88) 8 (203.20) 2 (50.80) 14¾ (6.64) A
1 (25) 6½ (165.1) 105/16 (261.94) 2¼ (57.15) 23½ (10.58)
1¼ (32) 6½ (165.1) 10⅞ (276.23) 2⅜ (60.33) 24½ (11.03)
1½ (40) 7½ (190.5) 10¾ (273.05) 2⅝ (66.68) 33 (14.85)
2 (50) 7½ (190.5) 11 (279.40) 2⅝ (66.68) 35½ (15.98)

PRESSURE RANGES
Valve size Maximum working ranges Valve size Maximum working ranges
inches (mm) psi (kg/sq cm) inches (mm) psi (kg/sq cm)
½ (15) 0-20 (0-1.41) 1¼ (15) 0-15 (0-1.06)
10-50 (0.70-3.52) 20-85 (1.41-5.98)
40-90 (2.81-6.33) 40-125 (2.81-8.79)
75-200 (5.27-14.06) 50-250 (3.52-17.58)
100-400 (7.03-28.12) 200-400* (14.06-28.12)*
300-600 (21.09-42.18) 1½ (40) 0-15 (0-1.06)
¾ (20) 0-10 (0-.70) 10-55 (0.70-3.87)
10-70 (0.70-4.92) 30-100 (2.11-7.03)
50-175 (3.52-12.30) 40-160 (2.81-11.25)
100-265 (7.03-18.63) 100-250 (7.03-17.58)
200-400* (14.06-28.12*) 200-400* (14.06-28.12)*
1 (25) 0-15 (0-1.06) 2 (50) 0-15 (0-1.06)
20-75 (1.41-5.27) 10-55 (0.70-3.87)
40-200 (2.81-14.06) 30-100 (2.11-7.03)
50-250 (3.51-17.58) 40-160 (2.81-11.25)
200-400* (14.06-28.12*) 100-250 (7.03-17.58)
200-400* (14.06-28.12)*
* Note: requires special diaphragm ring and pressure plate.

16
CASH VALVES CRYOGENIC VALVES AND CONTROLS

FR SERIES SELECTION GUIDE


Example FR- Z A W S S Z Z B H 01 − E 1
Model
FR- FR
FR6 FR-6
Material of construction
Z Bronze (FR, FR-6)
G 316 SST (FR, FR-6)
Valve size
C ½”
D ¾”
E 1”
F 1¼”
G 1½”
H 2”
Service
C Cryogenic service
Body/connection style
S 2 side inlets/bottom outlet - w/ NPT connections
Spring chamber style
S Standard
C w/ pressure screw cap
D w/ differential connection
V Vented
W Vent in wall / no cap
Spring chamber material
Z Bronze
G 316 Stainless steel
Diaphragm material
Z Bronze (cryo)
G 316 Stainless steel (cryo)
Body seat material
E 303 Stainless steel
G 316 Stainless steel
Z Brass
Pressure screw style
S Standard
Variation
04 303 Stainless steel trim w/ Teflon O-ring and teflon diaphragm gasket (ball seat, seat ring)
14 316 Stainless steel trim w/ Teflon O-ring and teflon diaphragm gasket (ball seat, seat ring)
Design revision
(-) Indicates original design
Spring material
E Stainless steel
Spring range
Refer to tables below

STANDARD SPRING RANGES (psig)


Spring Material Type Size 1 2 3 4 5 6
½” 0 - 20 10 - 50 40 - 90 75 - 200 100 - 300 100 - 400
¾” 0 - 10 0 - 15 10 - 70 50 - 175 100 - 265 ----
FR 1" 0 - 15 10 - 35 20 - 75 40 - 200 50 - 250 ----
SST 1¼" 0 - 15 10 - 30 20 - 85 40 - 125 50 - 250 ----
1½”, 2" 0 - 15 5 - 20 10 - 55 30 - 100 40 - 160 100 - 250
½” 200 - 600 ---- ---- ---- ---- ----
FR-6
¾”, 1",1¼",1½", 2" 200 - 400 ---- ---- ---- ---- ----

17
CASH VALVES CRYOGENIC VALVES AND CONTROLS

COMBINATION PRESSURE BUILDER-ECONOMIZER

PBE Series regulators combine the pressure building and economizer functions into one unit.
The economizer phase starts at the point at which the pressure build level is reached, assuring a
smooth transition between the two functions. For sizing information, please request engineering
data sheets 1074 (PBE-1A) and 1077 (PBE-2).

PBE-1A COMBINATION PRESSURE BUILDER-ECONOMIZER

Construction PRESSURE RANGES


Forged brass body and spring chamber; brass Max. working pressure
and stainless steel trim; PTFE/Armalon or psi (kg/sq cm)
bronze diaphragm; stainless steel pressure 50-175 (3.52-12.32)
spring. All parts are commercially cleaned for 150-350 (10.55-24.61)
oxygen service.

Temperature rating: +150°F to -320°F


(339K to 78K)
Maximum initial pressure: 600 psi
(42.18 kg/cm2)

DIMENSIONS
Dimensions
Size A B C Shipping weight B
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kg)
¼ (8) 2¼ (57.15) 3⅛ (79.38) ⅞ (22.29) 1.4 (0.65)
Low pressure - ranges to 175 psig
High pressure - ranges 150-350 psig C

CAPACITY INFORMATION
Air (SCFM)
Inlet - psig Outlet - psig 10% Droop 20% Droop
25 15 4.1 5.8
45 20 4.3 7.0
30 4.6 7.6
75 50 7.0 11.1
65 8.0 12.0
125 50 8.3 14.7
75 9.4 17.4
175 50 9.6 19.4
75 11.2 21.6
100 11.9 22.8
225 150 39.3 56.7
200 31.1 48.0
275 150 42.4 66.7
225 40.2 64.5
325 150 46.1 75.5
275 44.0 75.3
475 275 47.8 79.2
400 47.8 73.9
575 275 55.2 96.0
500 54.6 89.6

18
CASH VALVES CRYOGENIC VALVES AND CONTROLS

PBE-2 COMBINATION PRESSURE BUILDER-ECONOMIZER

Construction PRESSURE RANGES


Bronze body, spring chamber, trim and Max. working pressure
diaphragms; PTFE seat and diaphragm gasket; psi (kg/sq cm)
stainless steel economizer seat; stainless 10-30 (0.70-2.11)
steel spring, nuts and bolts. All parts are 20-75 (1.41-5.27)
commercially cleaned for oxygen service. 25-125 (1.76-8.79)
100-200 (7.03-14.06)
Temperature rating: +150°F to -320°F 150-250 (10.55-17.58)
(339K to 78K) 200-400* (14.06-28.12)
Maximum initial pressure: 400 psi *Only for stainless steel body
(28.12 kg/cm2)

DIMENSIONS
Dimensions
B
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
½ (15) 4½ (114.30) 5¼ (133.35) 3 (76.20) 9 (4.08)

CAPACITY INFORMATION A
Air (SCFM)
Inlet - psig Outlet - psig 10% Droop 20% Droop
15 10 8.7 11.0
30 10 9.7 14.9
20 12.4 22.3
25 13.7 21.3
55 25 25.8 38.4
50 25.5 41.9
75 25 27.3 41.2
65 37.6 55.5
100 50 41.7 64.3
75 48.5 77.1
125 50 42.5 66.0
75 54.9 87.2
100 61.5 95.1
150 125 77.5 114.5
200 125 90.8 140.2
150 96.4 149.5
250 175 103.1 176.1
225 119.3 197.0

19
CASH VALVES CRYOGENIC VALVES AND CONTROLS

PBE-5 COMBINATION PRESSURE BUILDER-ECONOMIZER

Construction PRESSURE RANGES


Forged brass body, bronze spring chamber; Max. working pressure
brass and stainless steel trim; bronze psi (kg/sq cm)
diaphragms; stainless steel pressure spring; 0 - 30 (0.00 - 2.11)
graduated adjustment screw. All parts are 20 - 50 (1.41 - 3.52)
commercially cleaned for oxygen service. 40 - 80 (2.81 - 5.62)
75 - 150 (5.27 - 10.55)
Temperature rating: +150°F to -320°F 100 - 275 (7.03 - 19.33)
(339K to 78K) 200 - 350 (14.06 - 24.61)
Maximum initial pressure: 650 psi 300 - 600 (21.09 - 42.18)
(45.7 kg/cm2)

NPTF
DIMENSIONS B
Dimensions
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kg)
C
NPTF
½ (15) 5.19 (131.8) 5.23 (132.9) 2.76 (70.2) 7 (3.2)
½ (15) 5.19 (131.8) 5.23 (132.9) 2.76 (70.2) 7 (3.2)
Note: 300 to 600 psi range, high pressure A
Ranges to 350 psi, low pressure
Bullnose Bullnose
0.839 (21.3) 9.81 (149.2) 5.13 (130.3) 4.48 (113.8) 8 (3.6)
B
0.839 (21.3) 9.81 (149.2) 5.13 (130.3) 4.48 (113.8) 8 (3.6)
Note: 300-600 psi range, high pressure
Ranges to 350 psi, low pressure

CAPACITY INFORMATION
A
Air (SCFM)
Inlet - psig Outlet - psig 10% Droop 20% Droop
10 2 0.4 0.5
5 0.4 0.5
30 20 2.7 3.6
50 20 3.1 4.4
25 3.4 4.8
40 8.6 11.5
75 40 10.4 13.7
60 11.3 16.5
100 75 20.9 28.9
150 75 29.4 40.9
100 39.4 55.6
125 32.9 48.8
200 100 50.5 67.8
125 53.3 76.5
150 55.9 80.4
250 125 65.5 90.1
150 71.2 99.6
200 78.5 118.4
300 200 94.1 133.3
250 94.5 136.8
600 300 169.9 258.1
500 183.1 298.9

20
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPES PBE-1, PBE-2, PBE-5 SELECTION GUIDE


Example: PBE1 A Z 3 S 01 − E 1
Model
PBE1 PBE-1A valve
PBE2 PBE-2 valve
PBE5 PBE-5 valve
Valve size
A ¼” (PBE-1A)
C ½” (PBE-2; PBE-5)
Body and spring chamber
Z Brass/bronze (all)
G 316 SST (PBE-2)
Economizer outlet side (see diagram below)
2 Left hand (PBE-1A)
3 Right hand; PB out l/h (PBE-1A)
B Bottom (PBE-2; PBE-5)
Option
S Standard
C with check (PBE-2, PBE-5)
Variation
01 Standard
02 With tube end connections (PBE-5)
Design revision
(-) Indicates original design (PBE-2; PBE-5)
B With active economizer (PBE-1A)
Spring material
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGE (psig)


Spring Material Type 1 2 3 4 5 6 7
PBE-1A 15 - 65 50 - 175 150 - 350 300 - 600 ---- ---- ----
SST PBE-2 10 - 30 20 - 75 25 - 125 100 - 200 150 - 250 200 - 400* ----
PBE-5 0 - 30 20 - 50 40 - 80 75 - 150 100 - 275 200 - 350 300 - 600
* Only available with PBE-2 SST body

21
CASH VALVES CRYOGENIC VALVES AND CONTROLS

LOW TEMPERATURE CUT-OFF VALVES

The temperature control valve between the vaporizer and service line regulator is designed
to cut off the gas flow if the gas temperature drops below a pre-determined point, usually
-20°F (144.4K), often caused by a rapid or quick gas draw. If the temperature drops below the
temperature control valve’s setting, the valve closes to prevent excessively cold gas from reaching
the service end of the system. In particular, the cold gas is prevented from contacting the final-
line regulator, which is not constructed or intended for such low-temperature conditions. The
valve opens automatically when gas temperature rises above the set point.

The Type LTC temperature control valve is a double-port valve with a range of 0°F to -40°F
(255K to 233K) for low temperature cut-off. As it is subject to ambient temperature under normal
conditions, it will normally be in a wide-open position. A copper well is recommended for each
installation, which allows the removal of the capillary bulb without depressurizing the system.

Note: Valve seat closure may take several seconds under normal operating conditions. In addition, Type LTC
fails in the closed position.

LTC REVERSE-ACTING TEMPERATURE REGULATOR FOR CRYOGENIC SERVICE


Dia.
Construction D 6 ft. approx.
Brass union ends; bronze body and trim; copper capillary armor and bellows; PTFE gasket and
packing; stainless steel spring; copper bulb and capillary.
Copper bulb is ½” x 5.82" (15 mm x 147.83 mm). All parts are commercially cleaned for oxygen
service. A copper well is available as an option and is recommended for each cryogenic 5.82” ½”
application. C NPTF

Maximum operating limits


Operating temperature range is 0°F to -40°F (255K to 233K); standard setting is -20°F (244K).
Maximum temperature limit is 300°F (408K); minimum temperature limit is -320°F (78K).
B
Maximum body pressure on all sizes is 400 psi (28.12 kg/cm2); however, for proper operation,
maximum pressure differentials as shown on page 21 must be observed.
E A

DIMENSIONS
Dimensions
Size A B C D E
in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm)
½ (15) 6.04 (153.42) 2.08 (52.84) 9.80 (248.92) 4.31 (109.48) 2.50 (63.50)
¾ (20) 6.04 (153.42) 2.08 (52.84) 9.80 (248.92) 4.31 (109.48) 2.50 (63.50)
1 (25) 6.04 (153.42) 2.08 (52.84) 9.80 (248.92) 4.31 (109.48) 2.50 (63.50)
1¼ (32) 7.61 (193.30) 2.75 (69.85) 10.47 (265.94) 4.31 (109.48) 3.56 (90.43)
1½ (40) 7.61 (193.30) 2.75 (69.85) 10.47 (265.94) 4.31 (109.48) 3.56 (90.43)
2 (50) 8.58 (217.43) 3.12 (79.25) 10.84 (275.34) 4.31 (109.48) 4.31 (109.48)
Note: Also available: Separable well - ask for part number 17960.
Thermal system repair kit - ask for part number 18052.

22
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE LTC MAXIMUM PRESSURE DIFFERENTIALS


Temperature setting
Valve size 0°F (255°K) -20°F (244.4°K) -40°F (233°K)
inches (mm) psi (kg/sq cm) psi (kg/sq cm) psi (kg/sq cm)
½-¾ (15-20) 400 (28.12) 400 (28.12) 400 (28.12)
1 (25) 275 (19.33) 400 (28.12) 400 (28.12)
1¼ - 1½ (32-40) 275 (19.33) 350 (24.61) 350 (24.61)
2 (50) 275 (19.33) 275 (19.33) 300 (21.09)
Note: It requires approximately 15°F change in temperature to fully close valve.

TYPE LTC CAPACITY INFORMATION (SCFH) OXYGEN SERVICE - 50 PSI AND 100 PSI LEVELS
50 psi level 100 psi level
Size Cv 1 psid 2 psid 5 psid 10 psid 1 psid 2 psid 5 psid 10 psid
½” 9.0 4109 5788 9044 12530 5480 7734 12147 16986
¾” 9.0 4109 5788 9044 12530 5480 7734 12147 16986
1” 13.0 5935 8361 13064 18100 7916 11171 17546 24535
1¼” 37.5 17122 24119 37684 52211 22835 32223 50612 70775
1½” 37.5 17122 24119 37684 52211 22835 32223 50612 70775
2” 52.5 23970 33767 52757 73095 31969 45113 70857 99085

TYPE LTC CAPACITY INFORMATION (SCFH) OXYGEN SERVICE - 150 PSI AND 200 PSI LEVELS
150 psi level 200 psi level
Size Cv 1 psid 2 psid 5 psid 10 psid 1 psid 2 psid 5 psid 10 psid
½” 9.0 6572 9280 14605 20495 7506 10602 16705 23485
¾” 9.0 6572 9280 14605 20495 7506 10602 16705 23485
1” 13.0 9492 13404 21096 29603 10842 15315 24129 33922
1¼” 37.5 27382 38665 60853 85394 31274 44177 69604 97853
1½” 37.5 27382 38665 60853 85394 31274 44177 69604 97853
2” 52.5 38334 54130 85195 119552 43784 61847 97445 136994

Note: psid values are pressure drops across valve.

TO DETERMINE CAPACITY

Determine operating pressure level at the valve and the maximum allowable pressure drop
across the valve. Then refer to table above reading down the appropriate column to the selected
pipe size. As an example: you are operating at a 150 psi pressure level and the maximum
allowable pressure drop across the valve is 2 psi. Look at the second table under the 150 psi
level and 2 psid column. For a 1¼” pipe size, the capacity would be 38,665 SCFH. Note: the values
shown in the table are for oxygen gas; all capacity figures are standard cubic feet per hour. To
determine capacity figures for other gases, consult the conversion chart below and multiply the
chart capacities by the factor given.

GAS CONVERSION FACTORS


Gas Oxygen Nitrogen Hydrogen Helium Argon
Factor 1.000 1.075 4.000 2.860 0.893

23
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE LTC SELECTION GUIDE


Example: LTC C S − 01 A
Model
LTC LTC valve
Valve size
C ½”
D ¾”
E 1"
F 1¼”
G 1½”
H 2"
Connection type
S NPT threaded union ends
B BSPT threaded union ends
Design revision
(-) Indicates original design
Variation
01 Catalog standard
02 With Thermowell
Temperature range
A -40°F to 0°F

24
CASH VALVES CRYOGENIC VALVES AND CONTROLS

FINAL LINE CIRCUIT (HOUSE LINE)

Liquid is forced into the vaporizer through the liquid line by the action of the vapor pressure
in the tank. The liquid in the vaporizer is warmed by ambient air (or sometimes by steam) and
changed into gas, which is then distributed through the final-line regulator. As the gas is at or
near ambient temperature, the diaphragm and seat in the regulator can be furnished in standard
rubber materials.

A-31 PRESSURE REDUCING VALVE FOR FINAL-LINE GAS SERVICE

Construction
Brass forged body, brass piston; NBR seat disc and diaphragm; aluminum spring chamber;
stainless steel spring. All parts are commercially cleaned for oxygen service. Standard valve has
side inlet-side outlet connections. Also available with side gauge connections.

Temperature rating: +150°F to 0°F (339K to 255K)


Maximum initial pressure: 400 psi (28.12 kg/cm2)

REDUCED PRESSURE RANGES


Maximum working ranges
psi (kg/sq cm)
2-25 (0.14-1.76)
15-65 (1.05-4.57)
B
40-100 (2.81-7.03)
50-150 (3.52-10.55)
75-175 (5.27-12.30)

DIMENSIONS
Dimensions
C
Size A B C Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
¼ (8) 2¼ (57.15) 33/16 (80.96) ⅝ (15.88) 1⅛ (0.51) A

25
CASH VALVES CRYOGENIC VALVES AND CONTROLS

A16, A31, A31S, A31VR, A32, A32S SELECTION GUIDE


Example: A16- A W S A S B B F 02 - D 1
Model
A16- A16 A32Z A32 w/ bronze body
A31- A31 A32E A32 w/ stainless steel body
A31S A31S A32S A32S
A31V A31VR
Size
Y ⅛” (A31, A31S)
A ¼" (A16, A31, A31S, A31VR, A32, A32S)
B ⅜" (A16, A31, A31S, A32)
Service
W Water/air
C Cryogenic (A32Z, A32E)
F Final line gas (A31)
V Vacuum service (A32VR)
Body/connection style
S Side inlet/side outlet - straight thru (A16, A31, A32)
R Side inlet/side outlet - straight thru w/ right side gauge port (A31S)
L Side inlet/side outlet - straight thru w/ left side gauge port (A16, A31S)
B Side inlet/bottom outlet w/ straight thru gauge connection (A31VR)
Spring chamber material
A Aluminum spring chamber (A16, A31, A31S, A32, A32S)
Z Brass spring chamber (A31, A32, A31VR only)
C Brass chrome plate spring chamber (A32 only)
B Brass bead blasted spring chamber (A32Z only)
Spring chamber style
S Standard
N Non-vented
P Panel mount
Diaphragm material
B Buna-N (A16, A31, A31S, A32S) T Neoprene w/ Teflon liner (A31, A31S)
L Buna-N w/ Teflon liner (A31, A31S) Z Bronze (A32 only)
G 316 SST (A32) R EPR (A31VR, A32S)
N Neoprene (A31, A31S) F EPR w/ Teflon liner (A31VR)
Seat material
B Buna-N (A16, A31, A31S, A32S) S Silicone (A31VR)
T Teflon (A31, A32, A32S) K Kalrez (A31VR)
V Viton (A31, A31S)
Pressure screw style
F Fillister (A16, A31, A31S, A32, A32S) K Knurled (A31VR)
T T-handle (A31, A31S) W Handwheel plastic (A21)
H Hex (A31, A31S, A32)
Variations
01 Standard 11 Standard variation w/ inlet screen (A31, A32)
02 Balanced piston (A31, A31S) 12 Balanced piston w/ inlet screen (A31)
Design revision
(-) Original design
Spring material
D Carbon steel (Industrial or final line gas service only)
E Stainless steel
Spring range
Refer to table below

STANDARD SPRING RANGES (psig)


Spring Material Type 1 2 3 4 5 6 7 8 9
A16 2 - 30 10 - 50 25 - 90 80 - 120 100 - 180 ---- ---- ---- ----
Steel A31, A31S, A32 2 - 30 10 - 50 30 - 90 80 - 120 100 - 180 ---- ---- ---- ----
A31VR (in/hg) 0 - 15 10 - 30 ---- ---- ---- ---- ---- ---- ----
A31 2 - 15 2 - 25 15 - 65 40 - 100 50 - 150 75 - 175 100 - 250 ---- ----
SST A32 2 - 15 2 - 25 15 - 65 40 - 100 50 - 150 75 - 175 100 - 250 200 - 400 300 - 600
A31S 2 - 15 ---- ---- ---- ---- ---- ---- ---- ----

26
CASH VALVES CRYOGENIC VALVES AND CONTROLS

HIGH PURITY REGULATING VALVES

A line of high purity regulating valves for electronic grade and other high purity gases is also
available. This includes pressure reducing valves, back pressure valves and valves suitable for
differential service.
Valve bodies are investment cast 316L stainless steel, with internal trim 316L bar stock.
Interior (wetted) surface finish is 15 micro inch or better. The finish is electropolished. Also, all
maintenance may be carried out without removing the valve from the line.

Sizes are ½” to 1½”, butt weld ends, 0.065 wall (½” size, 0.049 wall). Spring ranges are typically up
to 400 psig (28.12 kg/cm2) control.

Temperature limits are 400°F [478K] to -425°F [19K]. All valves are cleaned for high purity gas
compatibility.

Contact your sales representative for additional information and pricing.

Reference:
G60HP-pressure build service
FRHP-economizer service

C-776 SAFETY VALVE

Type C-776 cryogenic safety valves are available in sizes from ½” thru 2" (15 to 50 mm).

Request data sheet VCTDS-00515 for details.

2300 SHUT-OFF VALVE

Type 2300 is a brass shut-off globe style valve with ¼”, ⅜", and ½” (7, 10.5 and 15 mm) NPTF
connections. It offers the option of a stainless steel stub end inlet connection with a ⅜" (10.5 mm)
NPTF outlet connection.

Temperature rating: +150°F to -320°F [339K to 78K]


Maximum inlet pressure: 700 psig (49.2 kg/cm2)

27
CASH VALVES CRYOGENIC VALVES AND CONTROLS

TYPE 2300 SELECTION GUIDE


Example: 2300 A S P − 01
Model
2300 2300 shut-off valve
Valve size
A ¼”
B ⅜”
C ½”
Body connection
S Side in/side out w/NPT connections
B Side in/side out w/BSPP connections
1 Inlet ⅜" sch.10 x 1.125 long pipe/outlet ⅜" NPT
2 Inlet ⅜" sch.10 x 2.125 long pipe/outlet ⅜" NPT
3 Inlet ⅜" sch.10 x 3.375 long pipe/outlet ⅜" NPT
4 Inlet and outlet ⅜" sch.10 x 1.125 long pipe
5 Inlet ½” sch.5S x 2.125 long pipe/outlet ½” NPT
Handwheel colors
P Plain
B Blue
G Green
R Red
Design revision
(-) Indicates original design
Variation
01 Standard
02 With 4" extended stem

28
CASH VALVES CRYOGENIC VALVES AND CONTROLS

SY-70C ‘Y’ PATTERN STRAINERS

These strainers are suited for most cryogenic applications. Installed in the line ahead of automatic
regulators, they protect valve seats, gauges, meters, regulators and other equipment from most
foreign material to reduce maintenance costs and replacement expense.

Construction
ASTM B62 high-tensile cast bronze body, 100 mesh Monel® strainer screen; a brass blowoff plug
is shipped with each strainer. All parts are commercially cleaned for cryogenic service.

Temperature rating: +150°F to -320°F (339K to 78K)


Maximum set pressure: 400 psi (28.12 kg/cm2)
A

DIMENSIONS
Dimensions
Strainer size Blow off plug size A B Shipping weight
inches (mm) inches (mm) inches (mm) inches (mm) lbs (kgs)
½ (15) ¼ (8) 215/16 (74.68) 127/32 (46.99) 0.6 (0.27)
¾ (20) ¼ (8) 3⅝ (91.95) 115/16 (49.53) 1.3 (0.59)
1 (25) ⅜ (10) 4½ (114.30) 2¾ (69.85) 2 (0.91)
1¼ (32) ⅜ (10) 5⅛ (130.30) 311/32 (85.09) 3.1 (1.41)
1½ (40) ½ (15) 513/16 (147.58) 3¾ (95.25) 4.1 (1.86)
2* (50) ¾ (20) 613/16 (172.58) 413/16 (122.68) 9 (4.08)

Capacity information
Capacity information is available on request. Write to the factory supplying full valve and
application specifications.

NOTE
NPTF, also referred to as ‘Dryseal’ thread, is designed to provide a more leak-free seal without the use of PTFE
tape or other sealant compound. NPTF threads are interchangeable with NPT threads and are standard on all
Cash Valve products.

29
CASH VALVES CRYOGENIC VALVES AND CONTROLS

30
CASH VALVES CRYOGENIC VALVES AND CONTROLS

31
VCTDS-00514-EN © 2016, 2021 Emerson Electric Co. All rights reserved 09/21. Cash Valve is a mark owned by one of the companies in the Emerson Automation
Solutions business unit of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their
prospective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without
notice.

Emerson Electric Co. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of
any Emerson Electric Co. product remains solely with the purchaser.