COMMANDER

GENERAL PURPOSE, LOW VOLTAGE AC DRIVES

C300
COMMANDER C300
ENHANCED THROUGHPUT
WITH MACHINE SAFETY
Control Techniques has set the standards in motor control since 1973.

The Commander C300 provides flexible integration with safety and


communications. Commander C300 is ideal for applications that require cost-
effective integration into safety systems. With two Safe Torque Off (STO) inputs,
onboard PLC and an SI interface for industry standard fieldbuses, Ethernet
or extended I/O options, this feature set ensures Commander C300’s flexible
integration with any system.

Other Commander C300 benefits include:


Enhance up-time and system flexibility
• Flexible system integration and remote diagnostics through optional industrial Ethernet
and fieldbus communication
• Flexible I/O that is expandable with SI-I/O option module
• Enhanced functionality and onboard PLC programming provides a low-cost system
solution, minimizing the need for additional equipment such as PLCs
High performance open loop motor control
• RFC-A (Rotor Flux Control) algorithm for exceptional induction motor control
of demanding applications
• Closed loop current control without a position feedback device
• Speed control for conveyors, fans, pumps, and mixers, where their function
is controlled remotely with fieldbus or Ethernet communications
Communications
• Snap-in SI-Modules for industry standard fieldbus, Ethernet or extended I/O options
Two Safe Torque Off (STO) Inputs
Built-in PLC

Diagnostic Software
Our Drive Diagnostics APP allows users to
quickly diagnose faults. In the unlikely event that
you get a drive error, download our complimentary
Diagnostic Tool APP and input the error code from your
drive and you’ll be given a solution.
SOFTWARE
Download our APP at: www.ctdrives.com/diagnostics INCLUDED
*Warranty terms and conditions apply.

WWW.CONTROLTECHNIQUES.COM
COMMANDER C300
ORDERING INFORMATION
115 VAC, Single Phase 50/60 Hz Input, 230 VAC 3-Phase Output 575 VAC, 3-Phase Input & Output, 50/60 Hz Input
Commander C300 Input Normal Duty Heavy Duty Unidrive C300 Input Normal Duty Heavy Duty
Order Code* Phase HP Amps HP Amps Order Code* Phase HP Amps HP Amps
C300-01100017A 1 0.33 1.7 0.33 1.7 C300-05500030A 3 3 3.9 2 3
C300-01100024A 1 0.5 2.4 0.5 2.4 C300-05500040A 3 5 6.1 3 4
C300-05500069A 3 7.5 10 5 6.9
C300-02100042A 1 1 4.2 1 4.2
C300-06500100A 3 10 12 7.5 10
C300-02100056A 1 1.5 5.6 1.5 5.6 C300-06500150A 3 15 17 10 15
230 VAC, Single & 3-Phase Input, 3-Phase Output, 50/60 Hz Input C300-06500190A 3 20 22 15 19
C300-01200017A 1 0.33 1.7 0.33 1.7 C300-06500230A 3 25 27 20 23
C300-01200024A 1 0.5 2.4 0.5 2.4 C300-06500290A 3 30 34 25 29
C300-06500350A 3 40 43 30 34
C300-01200033A 1 0.75 3.3 0.75 3.3
C300-07500440A 3 50 53 40 44
C300-01200042A 1 1 4.2 1 4.2 C300-07500550A 3 60 73 50 55
C300-02200024A 1, 3 0.5 2.4 0.5 2.4 C300-08500630A 3 75 86 60 63
C300-02200033A 1, 3 0.75 3.3 0.75 3.3 C300-08500860A 3 100 108 75 86
C300-02200042A 1, 3 1 4.2 1 4.2 C300-09501040x** 3 125 125 100 104
C300-09501310x** 3 150 150 125 131
C300-02200056A 1, 3 1.5 5.6 1.5 5.6
C300-02200075A 1, 3 2 7.5 2 7.5
C300-03200100A 1, 3 3 10 3 10 Order String - Frame Size Key 690 V products are also available, for
details visit: www.controltechniques.us
C300-04200133A 1, 3 3 13.3 3 13.3 Example: C300-XX_ _ _ _ _ _ _
C300-04200176A 3 5 17.6 5 17.6 XX = Frame Size (01-09 above)
C300-05200250A 3 10 30 7.5 25
C300-06200330A 3 15 50 10 33
C300-06200440A 3 20 58 15 44 OPTIONS AT-A-GLANCE
C300-07200610A 3 25 75 20 61
Option Description Order Code
C300-07200750A 3 30 94 25 75
Configuration software CONNECT
C300-07200830A 3 40 117 30 83
Drive to PC USB cable
C300-08201160A 3 50 149 40 116 CT-USB-CABLE
(requires a 485 adaptor)
C300-08201320A 3 60 180 50 132
Drive Configuration Parameter cloning 4 GB
C300-09201760x** 3 75 216 60 176 AI-SMART-ADAPTOR
& Programming (includes 4 GB SD card)
C300-09202190x** 3 100 266 75 219 Parameter cloning
AI-BACKUP-ADAPTOR
460 VAC, Three Phase Input, 3-Phase Output, 50/60 Hz Input (requires an SD card)
C300-02400013A 3 0.5 1.3 0.5 1.3 8 GB SD card CTSD8GB
C300-02400018A 3 0.75 1.8 0.75 1.8 Remote LCD display REMOTE-KEYPAD
C300-02400023A 3 1 2.3 1 2.3 Remote LCD display
Operator Interfaces REMOTE-KEYPAD-RTC
C300-02400032A 3 1.5 3.2 1.5 3.2 with real-time clock
C300-02400041A 3 2 4.1 2 4.1 Remote display cable UM-LCD-485-XXX****
Input / Output*** Extended I/O SI-I/O
C300-03400056A 3 3 5.6 3 5.6 Modbus RTU AI-485-ADAPTOR
C300-03400073A 3 3 7.3 3 7.3 Modbus RTU with 24 V AI-485-24V-ADAPTOR
C300-03400094A 3 5 9.4 5 9.4 PROFIBUS DP SI-PROFIBUS
C300-04400135A 3 7.5 13.5 7.5 13.5 DeviceNet SI-DEVICENET
C300-04400170A 3 10 17 10 17 CANopen SI-CANOPEN
C300-05400270A 3 20 30 20 27 Communications*** PROFINET RT SI-PROFINET-V2
EtherCAT SI-ETHERCAT
C300-05400300A 3 20 30 20 30
EtherNet/IP, Modbus TCP SI-ETHERNET
C300-06400350A 3 25 38 25 35 Powerlink SI-POWERLINK
C300-06400420A 3 30 48 30 42 SI-INTERBUS-500K,
Interbus
C300-06400470A 3 50 63 30 47 SI-INTERBUS-2M
C300-07400660A 3 60 79 50 66 Application Programming PLC programming MACHINE-CONTROL-STUDIO
C300-07400770A 3 75 94 60 77 Software & Diagnostics Digital oscilloscope CTSCOPE
External EMC filter
C300-07401000A 3 75 112 75 100
Power Accessories Line & load reactors
C300-08401340A 3 125 155 100 134 Dynamic braking resistors
C300-08401570A 3 150 184 125 157 UL Type 1 conduit kits Consult factory
C300-09402000x** 3 150 221 150 180 Environmental Protection Retrofit for
C300-09402240x** 3 200 255 150 211 & Cable Management Commander SK
*Add 10101AB100 to the base order code when ordering standard US (60Hz) default products Fan replacement kits
**x= A or E (9E frame requires an external AC Line Reactor) ***frame sizes 2 and up accept 1 SI option
****Shielded RS485 patch cable, CAT5e, conductive metal RJ45 connectors, XXX=cable length in
Note: Ratings are shown for 3 kHz switching frequency. 5 foot increments (max 330 ft), standard lengths are (005, 010, 015, 025 and 050)

WWW.CONTROLTECHNIQUES.COM
COMMANDER C300
RATINGS & DIMENSIONS
Ratings Dimensions & Weights W

Voltage ratings Dimensions


Frame Size H x W x D (in)
Weight (lbs)
100 V - 120 V ± 10% ü 01 6.3 x 3.0 x5.1 1.7
02 8.1 x 3.1 x 5.9 2.2
200 V - 240 V ± 10% ü 03 8.9 x 3.5 x 6.3 3.3
04 10.9 x 4.5 x 6.9 6.9
380 V - 480 V ± 10% ü 05 15.4 x 5.6 x 7.9 16.3 H
06 15.4 x 8.3 x 9.0 30.9
500 V - 575 V ± 10% ü 07 21.9 x 10.6 x 11.0 61.7
500 V - 690 V ± 10% ü 08
09E
31.7 x 12.2 x 11.4
39.8 x 12.2 x 11.4
114.6
101.4
Control mode 09A 43.6 x 12.2 x 11.4 146.6
Open loop vector or V/Hz control for induction Additional distance should be added to the height
motor control ü dimension (H) when the AI options are fitted. D
Open loop Rotor Flux Control
for induction motor control (RFC-A) ü
Active Front End (AFE) power quality converter ü

Heavy Duty Ratings: 0.33 HP to 150 HP (0.25 kW to 110 kW) How to select a drive
Normal Duty Ratings: 0.33 HP to 200 HP (0.25 kW to 132 kW) (Consult online catalog for complete drive information)
Supply phases: Frame size 1 and 2: 115 V drives 1Ø, 1. Electrical Considerations
230 V drives 1Ø or 3Ø; Frame size 7 and
larger 3Ø; 460, 575 and 690 V drives 3Ø • What is the supply voltage?
Control connections: 3x Analog I/O, 5x Digital I/O, 2x STO, 1x • Single or 3Ø input power?
Relay • What is the motor rating?
• Continuous current – FLA (Full Load Amps)
Drive rating: IP21 / UL open class as standard
• Select the drive based on motor Amps rather than horsepower
Keypad: Fixed LED
Option slots: 1 (frame size 2 and above) 2. Load Type (choose one)
Parameter cloning via: PC tools, SD card • Normal Duty: Peak current is 110% of drive rating (fans, pumps, etc.)
• Heavy Duty: Peak current is 180% (mixers, conveyors, etc.)

3. Drive Mechanical Mounting


• Panel mounting – as standard
Visit www.Drive-Setup.com • Wall mounting – UL conduit kits are available
for step-by-step guides, • Through panel mounting – frames 5 and up
videos, software & product
support documentation.

©2022 Control Techniques a Nidec Motor Corporation business. The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be
guaranteed as Control Techniques has an ongoing process of development and reserves the right to change the specifications of its products without notice.

Control Techniques Americas. Registered Office: 12095 NW 39th Street, Coral Springs, FL 33065 USA
+1 800 893-2321 Part No. FLI-C300 09/22