Brosur Monitor f15

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

F15 Multi-parameter Monitor

(15 inches)
Features
♦ 15' color TFT LED screen supports display 9~13 waveforms, support HDMI output
♦ Support 7 channel ECG waveform display simultaneously
♦ Newly advanced ARM A8 microcontroller, calculating speed is 4 times faster than traditional products
♦ Generate ID automatically when register a new patient and complete patient information management. Support medical
history search by patient ID, name and mobile number
♦ Support data control / input by mouse / keypad
♦ Three-level acousto-optic alarm and support alarm review.
♦ Multi-display mode to meet different clinical requirement, standard interface, big font, OxyCRG, trend graph, NIBP review and
full leads ECG interface.
♦ 21 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
♦ Suitable for monitoring adult, pediatric and neonatal patient
♦ Support online software upgrading by net/USB
♦ Support wired/ wireless CMS based on TCP/IP (built-in WIFI module)

Standard Configuration:
♦ Anti-glare screen, Large capacity rechargeable battery, 3/5-Lead ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
F15 Multi-parameter Monitor Specification

HDMI & Net Interface Control Panel & Color LED Display 50 mm Thermal Printer
(7 hotkeys & Japan SHARP LED) (Japan SEIKO Printer Head)

Interface

ECG Full Lead Standard Display

Big Font Display Oxy CRG

Trend Table NIBP Review


F15 Multi-parameter Monitor Specification
Dimension and Weight - Resolution: 1 bpm

- Dimension: 380mm*360mm*160mm - CMRR: Diagnostic Mode >90 dB


- Weight: 4.5 Kg Monitor Mode >105 dB

Power Supply Surgery Mode >105 dB


- Voltage: AC100~240V, 50/60HZ, Power≤60W - Input impedance: ≥5.0 Mohm

Display - ECG signal range: ±6 mV


- 15" color TFT LED - Leakage Current: < 10 μA

- Resolution: 1024*768 pixels - Baseline Recovery: < 5 s After defibrillation (MOR or OPS mode)

Battery - Bandwidth
- Type: Rechargeable lithium battery 14.8V, 2200mAH Surgery 1 ~ 25 Hz
- Charge Cycle: 500 times Monitor 0.5 ~ 40 Hz
- Working time: 2 hours (larger battery for 4-5 hrs) Diagnostic 0.5 ~ 130 Hz

Recorder (Option) HR
- Method: Thermal printer - Range Adult: 15 ~ 300 bpm,
- Paper width: 50 mm Neo/ Ped: 15~ 350 bpm
- Paper speed: 25/50 mm/s - Resolution: 1 bpm
- Trace: Max. 3 tracks - Accuracy: ± 1% or ± 1bpm, which greater
- Recording way: Real-time Recording, Review printing ST Segment
Alarm
- Range -2.0 ~ +2.0 mV
- Level: Low, medium and high
- Indication: Auditory and visual - Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater

Input device - Other range: unspecified


- Touch screen (option) Respiration
- Knob (Standard) - Method: Impedance between RA-LL, RA-LA
- Keypad input (Standard) - Gain: ×0.25,×0.50,×1,×2
- Mouse/ Keyboard input (option) - Respiration Rate: Adult: 0 ~ 120 BrPM

System Output & Extensible Interface Neonatal / Pediatric: 0 ~ 150 BrPM


- Ethernet Network: 1* RJ45 - Resolution: 1 BrPM
- 1* USB port - Accuracy: ±2 BrPM or ±2%, whichever is greater
- Video Output: 1*HDMI port (option) - Apnea Alarm: 10 ~ 40 s

Trend & Reviewing: NIBP


- Trend: 1440 hours - Method: Oscillometric
- Waveform review: 2 hours - Measure mode Manual, Auto, STAT
- NIBP measurement reviewing: 1000 groups - Measure Interval in AUTO Mode 1~ 480 min
- Alarm event: 2000 groups - Measure Range: Adult: SYS: 30 ~ 270 mmHg

Operating Environment DIA: 10 ~ 220 mmHg


- Temperature: 5 ℃~ 40℃ MEAN: 20 ~ 235 mmHg
- Humidity: 15% ~ 80% (non-condensing) Pediatric: SYS: 40 ~ 235 mmHg
- Atmosphere pressure: 86 KPa ~ 110 KPa DIA: 10 ~ 220 mmHg

Transportation and Storage Environment MEAN: 20 ~ 225 mmHg


- Temperature: -20℃~50℃ Neonate: SYS: 30 ~ 135 mmHg
- Humidity: 10%~90% (non-condensing) DIA: 10 ~ 110 mmHg
- Atmosphere pressure: 86 KPa ~ 110 KPa MEAN: 20 ~ 125 mmHg

Safety: - Static pressure accuracy: ±3mmHg


- IEC60601-1 Approved, CE marking according to MDD93/42/EEC - Resolution: 1mmHg
- With reference to RoSH Directive 2011/65/EU recasting - Accuracy: Maximum Mean deviation ±5mmHg

Performance: Maximum Standard deviation ±8mmHg


ECG - - Dual-overpressure Protection for hardware and software

- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V TEMP
12 Leads (option), I, II, III, AVR, AVL, AVF, V1~V6 - Channel: Dual-channel, provide T1; T2; △T1
- ECG waveform: 3 channels - Measuring and Alarm Range: 0 ~ 50 ℃
- Gain: × 2.5mm/mV (× 0.25), × 5.0mm/mV (× 0.5), × 10mm/mV (× 1), - Resolution: 0.1℃
×20mm/mV (× 2), Auto - Accuracy: ± 0.1℃

- Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s SpO₂


- ECG waveform: 3 channels - Measurement and Alarm Range: 0 ~ 100 %
- Accuracy: ±1bpm or ±1%, whichever is greater - Resolution: 1%
- Accuracy: 70% ~ 100%, ±2 % IBP (Option)
0% ~ 69%, unspecified - Max Channel: 2
- Support Pitch tone - Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
PR - Measurement way: Thermal resistance way
- Measuring and Alarm Range: 0~250 bpm - Press Sensor: Sensitivity 5 uV/V/mmHg, ±2%
- Resolution: 1 bpm Impedance 300-3000Ω
- Accuracy: ± 2bpm - Resolution: 1 mmHg

Nellcor-SpO₂ (option) - Unit: mmKg, kPa


- Measurement Range: 0 ~ 100 % - Measuring and alarm range:
- Resolution: 1 % ART 0 ~ 300 mmHg
- Accuracy: 70% ~ 100%, ±2 % (adult) PA -6 ~ 120 mmHg
70% ~ 100%, ±3 % (Neonate) CVP/RAP/LAP/ICP -10 ~ 40 mmHg
70% ~ 100%, ±2 % (Low Perfusion) P1/P2 -10 ~ 300 mmHg
0% ~ 69%, unspecified - Actualization interval: about 1 Sec.

PR Depth of Anesthesia (BIS) (Option)


- Measurement range: 25 ~ 300 - EEG sensitivity: +/- 475μV
- Resolution: 1bpm - Noise: < 2uVp-p (1-150 Hz)
- Accuracy: 20 ~ 250 bpm, ±3 bpm - CMRR: > 100 dB

Masimo SpO2 (option) - Input impedance: > 50 Mohm


- Measurement Range: 0 ~ 100 % - Sample rate: 1024 samples/s, 16 bits
- Resolution: 1 % - Index and display update: 0-100, filter 1-47 Hz, 1 sec. display update
- Accuracy: 70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions) - EEG waveform: ± 500 μV scaleable, filter 1–30 Hz, 3 sec. window length.
70% ~ 100%, ±3 % (neonate, non-motion conditions) - ESR: 0-100%
70% ~ 100%, ±3 % (motion conditions) - EMG 0-100 arbitrary unit: Curve and bar
0% ~ 69% unspecified - Index trend: 5 min and 60 min
PR - Alarms: IoC high and low user selectable limits
- Measurement range: 25 ~ 240 - Artifact rejection: Automatic: user can disable.
- Resolution: 1bpm - Sensor impedance range: 0 - 14 kohm
- Accuracy: ±3 bpm (non-motion condition) Multi-gas/O2 (AG) (Option)
±5 bpm (motion conditions) - Method: Infrared absorption

EtCO₂ ( Mainstream/ Sidestream/ Micro-stream) (Option) - Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo,
- Measure method: Infrared spectrum Hal, O2 (Optional paramagnetic sensor)
- Measure Range: 0 - 19.7% (0 - 150 mmHg) - Measurement range: CO2: 0~30%, N2O : 0~105%
- Resolution: 0.1 mmHg O2, :0~105%, Enf, Iso, Hal: 0~30%,
- CO2 Accuracy: 0 ~ 40 mmHg, ±2 mmHg Sevo: 0~30%, Des:0~30%
41 ~ 70 mmHg, ±5% of reading - Data output: Fi and ET values
71 ~ 100 mmHg, ±8% of reading - Respiration rate: ±1BrPM (2~60BrPM)
101~ 150 mmHg, ±10% of reading 61~100BrPM (unspecified)
at 760 mmHg, ambient temperature of 35℃) - Other: Up to 4 waveforms displayed
- Breath Rate: 3 - 150 bpm Agent mixture detection

MAC value displayed


* Specifications subject to change without prior notice.

Configuration

3/5 EtCO2 Nellcor/ Central


Feature SpO2 Dual Dual Depth of Multi-gas Printer Wall-mount Touch
Lead NIBP TEMP RESP Main-stream/ MASIMO HDMI Monitoring
/PR TEMP IBP Anesthesia (AG) 50mm /Trolley Screen
ECG Side-stream SpO2 Station

F15 √ √ √ √ √ Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt

Shenzhen Unicare Electronic Co., Ltd.


Add: 3D, Building4, Tian-an Industrial Zone, Nan You, Distributor:
Nanshan District, Shenzhen, 518054, P.R. China
Tel: +86-(0)755-3336 9088 Fax: +86-(0)755-3336 6818
Email: [email protected] www.unicare-med.com