Boq Part 03
Boq Part 03
Boq Part 03
Page 1 of 8
Name of Work: civil, architectural and associated works for sidewalk canopy for MAR bridge (PART - 03) at KIA
Rate in Amount in
Sl.No Description of item Unit Qty
INR INR
A MASONRY WORKS
1 Providing and constructing walls with cement concrete solid blocks of size 400 x SqM 65.00 -
200 x 200 mm west side of the canopy (l,b,h) having block density not less than
1800 kg/m3 having a minimum average compressive strength of 4.00 N/mm2 of
approved make confirming to IS 2185 (Part 1):2005 and constructed with CM 1:4, as
per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing,
hire charges of machineries etc., complete as per specifications.
Drawing No: B01F38-PAA-A_OL-TYP-ZZ-DWG-2001,2002
2 Providing, laying flamed granite flooring for entire length of canopy water cut 20 SqM 250.00 -
mm thick granite of approved colour, shade and size cut and laid as per approved
designs, details and pattern as per drawings including full round nosing as required.
This is to be laid over prepared base cement mortar 1:4 of 25mm thickness with
ordinary Portland cement, fit jointed with / without groove, with white cement /
grout of approved make slurry mixed with pigment to match shade of granite
including all finishing, impregnation of 2 coats all sides, all as required, as per
specifications and drawings and as directed complete for flooring, staircase landing,
etc., complete including the cost of materials, labour, curing, etc., complete as per
specifications. Basic price of granite is Rs 2000/ SqM.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-2001
3 Providing and laying 20 mm thick polished water cut granite for skirting / risers Rmt 144.00 -
of 150 mm high for entire length of canopy of approved colour, shade to match
flooring set in cement mortar of mix 1:3 of 12mm thickness including pointing with
white cement mixed with colour pigment to match the colour of the granite including
chipping walls wherever necessary. The skirting / risers is to be fixed as per the
approved designs and drawings etc., complete including chamfer / bull nosing /
rounding as directed including the cost of all materials, labour, curing etc.,
complete as per specifications. Basic price of granite is Rs 2000/ SqM
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-2001
Page 2 of 8
4 Providing, laying polished granite flooring for entire length of canopy water cut SqM 110.00 -
20 mm thick granite of approved colour, shade and size cut and laid as per approved
designs, details and pattern as per drawings. This is to be laid over prepared base
cement mortar 1:4 of 25mm thickness with ordinary Portland cement, fit jointed with
/ without groove, with white cement / grout of approved make slurry mixed with
pigment to match shade of granite including all finishing, impregnation of 2 coats all
sides, all as required, as per specifications and drawings and as directed complete for
flooring, staircase landing, balconies, etc., complete including the cost of materials,
labour, curing, etc., complete as per specifications. Basic price of granite is Rs 2000/
SqM
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-2001
5 Providing, laying 20 mm thick polished sadarahalli water cut granite ramp near SqM 25.00 -
access 3 transition area of approved colour, shade and size cut and laid as per
approved designs, details and pattern as per drawings. This is to be laid over
prepared base cement mortar 1:4 of 25mm thickness with ordinary Portland cement,
fit jointed with / without groove, with white cement / grout of approved make slurry
mixed with pigment to match shade of granite including all finishing, impregnation of
2 coats all sides, all as required, as per specifications and drawings and as directed
complete for flooring, staircase landing, balconies, etc., complete including the cost
of materials, labour, curing, etc., complete as per specifications.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-2001
6 Providing and laying 20 mm thick polished sadarahalli water cut granite ramp Rmt 50.00 -
skirting / risers of 150 mm high near access 3 transition area of approved colour,
shade to match flooring set in cement mortar of mix 1:3 of 12mm thickness including
pointing with white cement mixed with colour pigment to match the colour of the
granite including chipping walls wherever necessary. The skirting / risers is to be
fixed as per the approved designs and drawings etc., complete including chamfer /
bull nosing / rounding as directed including the cost of all materials, labour, curing
etc., complete as per specifications.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-6001
D PAINTING WORKS
1 Providing and applying synthetic enamel paint matte finish for MS Members and SqM 175.00 -
plastered surfaces (toe wall and block work) with two coats of approved make,
colour and shade on new surface with enamel paint to give even shade including
applying priming coat and putty work after brushing / cleaning with ready mix
enamel priming paint including preparing the surface after thoroughly cleaning the
surface, sand papering and knotting ready mix paint including cost of material,
labour, etc., complete as per specifications.
Drawing No: B01F38-PAA-A_OL-TYP-ZZ-DWG-2001,2002
The structural glazing is to be fabricated as per drawings with partly fixed and partly
openable all as per the detailed drawings. The openable window shutters portion
shall be fabricated with aluminium sections and powder coated to suit the other
sections. The openable portion shall be provided with necessary heavy duty stainless
steel stag and locking arrangements with necessary hinges. All the works should be
completed as a whole item of work for all heights including all lead, lift, scaffolding
etc., complete. The minimum sizes, thickness and weight per unit length of the
aluminium section is to be given by the tenderer. However, nothing extra shall be
payable to the contractors for using larger/ heavier section than those given if found
inadequate as per specifications and design calculations. The Vendor should submit
the design to the client and get approved for the same. The system should take care
of the vibration coming due to vehicular movement on the bridge.
Drawing No: B01F38-PAA-A_AD-TYP-ZZ-DWG-5003,5004
Page 3 of 8
2 Providing and fabricating structural glazing semi unitized system on west facade SqM 125.00 -
of approved make as per design, drawings and specifications using aluminium
extrusions for vertical and horizontal members as frame with powder coating to
specified thickness. The glazing system to be of approved shade, make, colour using
13.52mm thick laminated toughened tinted glass (6mm thick toughened glass +
1.52 PVB + 6mm thick toughened glass) with all necessary accessories like ultra
glass silicon sealant, space tape, masking tape, galvanised anchor bolts, machine
screws, with suitable MS angle, M.S. galvanised L brackets, structural sealant setting
clocks., fasteners, wall connection etc., complete.
The structural glazing is to be fabricated as per drawings with partly fixed and partly
openable all as per the detailed drawings. The openable window shutters portion
shall be fabricated with aluminium sections and powder coated to suit the other
sections. The openable portion shall be provided with necessary heavy duty stainless
steel stag and locking arrangements with necessary hinges. All the works should be
completed as a whole item of work for all heights including all lead, lift, scaffolding
etc., complete. The minimum sizes, thickness and weight per unit length of the
aluminium section is to be given by the tenderer. However, nothing extra shall be
payable to the contractors for using larger/ heavier section than those given if found
inadequate as per specifications and design calculations. The Vendor should submit
the design to the client and get approved for the same. The system should take care
of the vibration coming due to vehicular movement on the bridge.
Drawing No: B01F38-PAA-A_AD-TYP-ZZ-DWG-5003,5004
2 Providing and fixing semi unitized laminated toughened glass roof for the SqM 66.00 -
transition area of thickness 13.52 mm (6mm thick toughened glass + 1.52 PVB +
6mm thick toughened glass) . The glass to be securely fixed on MS box frame section
of required size and powder coated with approved colour and necessary beading,
scaffolding / staging all complete as per drawings. Allow for cutting of holes and box
outs for services etc. and finishing the edges mirror polished smooth etc. complete as
per approved design, shop drawings and as directed by the Engineer. The system
should take care of the vibration coming due to vehicular movement on the bridge.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-2003
Page 4 of 8
G MISCELLANEOUS WORKS
1 Providing and fixing stainless steel railing for west wall as per approved design, Rmt 19.00 -
drawing and specification approximately 815 mm high with matt / glossy finish. The
verticals are of 75 mm width and 6 mm thick stainless steel at 900 mm centre to
centre. This is to be fixed securely to the RCC toe wall with SS flange and SS cover.
The vertical balusters are securely fixed at the lower level in position at the lower
level by welding / anchor bolts to M.S members / RCC toe wall including necessary SS
covers as shown in the drawing or any other method of fixing as approved by the
Engineer in charge like epoxy grout etc. All SS material shall be 16 gauge and 304
grade.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5001
2 Supply and installation of aluminium perforated sheet of 3 mm thickness. The SqM 80.00 -
perforation design to be as per approved drawing. The aluminium sheet to be
securely fixed to the M.S member with the required sub frame. The aluminium sheet
to be finished with exterior grade powder coating of any approved colour not less
than 50 micron thick. This powder coating is of exterior grade will be provided with
a warranty of 15 years. The aluminium sheet will be bent / welded / screwed with
sub frame will be done as and where required.
The aluminium sub frame and bracing for aluminum perforated sheet and similar
works, aluminium section to be of 50 mm X 100 mm and a flange of 10mm on
either side or as required, which is provided on one side of the section. The
aluminium section to be finished with exterior grade powder coating of any
approved colour not less than 50 micron thick. This powder coating is of exterior
grade will be provided with a warranty of 15 years. Aluminium section will be fixed
with the necessary bolt and nut to the existing MS Structure framework.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-3002,5004
3 Providing and fixing GI flashing on west façade, top of crash barrier on east side of SqM 162.00 -
the canopy of 2 mm thickness, powder coated not less than 50 microns of approved
colour and shade fixed with counter sunk screws.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5003,5004
4 Providing and fixing GI Painted Wire Mesh jali work of size 25 x 25 mm with 4 mm SqM 72.00 -
dia (green wall) or openings using GI Sheets and GI angle or tube all-round with
necessary frame work as per approved design, drawing finished including cutting
steel sections and welding or fixing with bolts the same to required pattern with a
cost of materials, fixtures, labour and HOM complete as per specifications.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5002
5 Providing, fabricating and erecting structural steel onto columns / beams / trusses M.T 1.00 -
and other structural members for green wall, life line and similar works consisting
of tubular / rolled / built-up sections profiled to required shape as per design and
drawing. Insert plates with welded hold fasts for supporting structures, internal
threaded sleeves including HSFG bolts tightened by torque wrench and primer coat
and three coats of enamel paint of approved make and colour. (Note: Type and
shape may vary as per detail design and drawing). This includes bending of standard
steel sections and plate sections welded / bolted to built-up sections to required
shape & profile at site.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5002
6 Providing and fixing of lifeline of stainless steel anchorage of 8 mm thickness, life Rmt 66.00 -
line of 7 mm x 19 mm. The wire to be designed to take load in X and Y axis. An end
wire termination for other end of wire rope to be provided (swage less) at every 15
meters in a line. End anchor point to have a minimum breaking strength of 15 kN, A
carriage body which can cross all intermediates without disconnection. Complete
system to be complying with EN795:2012 Type C and CEN/TS16415:2013 to allow
simultaneously 4 persons to work in a line. System to have a valid type certificate
complained to EN795.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5003,5004
7 Providing and installing a baffle comprising of aluminium powder coated section of Rmt 81.00 -
size 50 mm X 350 mm having 3 mm thickness. The baffle to be securely fixed to the
M.S member as per design and drawing. The aluminium sections to be finished with
exterior grade powder coating of any approved colour not less than 50 micron thick.
This powder coating is of exterior grade and will be provided with a warranty of 15
years.
Drawing No: B01F38-PAA-A_KP-TYP-GF-DWG-5003,5004
8 Providing and fixing Aluminium back plate signages, with 3m vinyl sticker on it. Nos 5.00 -
Location as per drawing & site conditions, wall hung / ceiling suspended to be
considered. Basic size of signage to be considered 150 mm x 500mm. Overall signage
scheme to be considered as per drawings,Site location & Engineer in charge
Page 5 of 8
Providing and fixing metalic expansion solutions for installation gap of 50 with Rmt 16.00 -
extruded centre plate and extrusion araangment confirming to ASTM B221, 6063
alloy T-5 (with out using turn bars / gaskets) enabling the system to take movement
& loading as per design in 3 directions. The system exposed width not to exceed
42mm . EPDM Mositure barrier membrane to be layed to avoid water ingress.
9 Providing and fixing EPDM compression seal confirming to BS 4255 with 6 holes to
accomodate compression and expansion to +/- 25mm for an installation gap of
50mm. To be used with epoxy adhesive for bonding with concrete. OVerall system
should be suitable for the area & usage & as per design drawings. THis area is on
ramp & overall system to be laid on mild slope
Page 6 of 8
Name of Work: civil, architectural and associated works for sidewalk canopy for MAR bridge (PART - 03) at KIA
Amount in
Sl.No. Description of item Unit Qty Rate in INR
INR
S.01 EARTHWORK
Earthwork in excavation for all depths for foundation of
structures in all types of soil including strutting, shoring,
planning, dewatering, handling of uncharted/dead utilities
1 and disposal of excavated material upto a lead of 50 m and
with all lifts including dismantling footpath, pavements, etc
as per drawings and specifications complete.
1.1 For open foundation for columns, lift pits, staircase etc Cum 129.60 0.00
Back filling with good quality excavated material including Cum 95.00 0.00
1.2
compaction in layers
Extra over item 1.1 above for excavation and dismantling of Cum 25.92 0.00
1.1
road pavements.
Removing the surplus excavated material, all kinds of soil
2 and malba etc. away from site and disposing as directed by
The Engineer.
2.1 For lead 0 - 5 km Cum 38.68 0.00
2.2 For lead 5 - 10 km Cum 0.00 0.00
2.3 For lead > 10 km Cum 0.00 0.00
Total of S.01 :Earthwork 0.00
S.02 CONCRETE : PLAIN AND REINFORCED CONCRETE
Providing & laying in position, machine batched, machine Cum 20.67 0.00
mixed & machine vibrated concrete of grade given below,
using 20 mm size aggregate including cost of shuttering if
1.1 any etc. for 100 mm thick PCC (Grade M15/20) below
foundations,pilecaps, plinth beams, basement & water tank,
raft slabs under floor etc. at all levels complete.
Providing & laying in position, machine batched, machine Cum 0.00 0.00
mixed & machine vibrated concrete of grade given below,
using 20 mm size aggregate including cost of shuttering if
1.1 any etc. for 100 mm thick PCC (Grade M15/20)
(Reinforcement (if any) being paid separately) at floor level
on concourse, platform, etc . at all levels complete.
Reinforced cement concrete M30 grade in open foundations Cum 9.60 0.00
for compound wall etc using 20mm and down size graded
granite metal in open foundations (excluding cost of steel
reinforcement )as per drawing and technical specifications
2.1 machine mixed concrete laid in layers not exceeding 15
cms ,thick, well compacted including cost of
materials ,labour,HOM (Hire, operation & Maintenance) of
machineries and curing complete as per specifications .
RCC M30 grade for column pedestals ,columns, staircase Cum 2.92 0.00
beams, slabs etc.using 20mm and down size graded granite
metal upto 10m ht as per drgs .,machine mixed ,concrete
2.2 laid in layers not exceeding 15 cm thick ,well compacted
incl cost of materials ,labour,HOM of machineries and curing
complete as per specifications .
2.3 M 25 grade cement concrete for sill and similar works. CuM 2.75 0.00
2.4 Precast
RCC pre sill
castabove
slab -masonry wall
West façade CuM 5.00 0.00
Total of S.02 : Plain Cement and Reinforced Concrete 0.00
S.03 REINFORCEMENT
Providing T.M.T. steel reinforcement of grade Fe 500 for
R.C.C. work including straightening, cutting, bending,
hooking, placing in position, lapping and / or welding
1 wherever required, tying with binding wire and anchoring to
the adjoining members wherever necessary complete as per
design including cost of materials, labour, HOM of
machineries, etc., complete as per specifications.
Using standard rolled sections such as angles, channels etc. MT 47.88 0.00
for purlins, base plates, gusset plates, stiffeners,
connections , cleats, plates -conforming to IS:2062 (Yst-
1.1 250Mpa) etc, or standard tubes, square, rectangular pipe
section conforming to IS: 4923 (Yst-240MPa) and IS:1161
(Yst-240Mpa), OR Standard plate sections, welded & built-up
to required shape & profile