Rect - Megapower Mc2600

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MegaPower MC2600

Indoor/outdoor power supply


Flexible and scalable to satisfy your present and future needs
Smart battery management gives long battery life-span
Automatic battery test including advanced scheduled test / constant test / fast test
Lower operating cost due to energy saving standby function for rectifier
Powerful hybrid power management function
Log record and statistic with advanced algorithm
Minimized installation time as a result of easily configurable file upload/download

Product description
MC2600 is the new generation DC power controller module developed by MEGMEET. The Controller module adopts ARM 32-bit Cortex-M4 CPU
as primary controller, and RTOS as system platform. MC2600 offers many features and functions, and a more robust, user-friendly, and easy-to-
use interface.

Applications
Indoor/outdoor power supply
In addition to controlling of rectifier modules, AC/DC distribution, MC2600 manages battery charge, discharge, test, maximizes battery capacity and
lifespan. With improved memory, MC2600 can store mass alarm/event and data logs for system performance analysis and fault diagnose.
DI/DO connectors and RS485/Ethernet ports provide flexible extension function and parameters setting, software and logs downloading/uploading,
remote monitor system accessing.

KEY FUNCTIONS
● Eeas rement
◆ Analog value measurement
◆ Digital value measurement
● omm nidation
◆ The Controller can communicate with the host computer in 2 modes: RS485 and Ethernet (WEB and SNMP). It can communicate with rectifier
and solar modules in CAN bus mode.
2 southbound RS485 for battery BMS or extension function boards.
For remote and local monitor system via WEB browser, controlling, parameters upload/download, data load.
SNMP protocol supports GET, SET and TRAP on Ethernet.
● c
◆ 8+1 user digital input interfaces freely configurable
8 groups of dry contact outputs freely configurable

● N anu C
◆ 128*32 LCD screen display running information and local setting interface
◆ Green/Yellow/Red LEDS indicate running status for local instant diagnose.
● Alarm history, event history store
◆ 1000 alarms history and 1000 events history store, FIFO for system analysis.
● ata lo storeIauvandeu versionO
◆ 2000 data logs including bus voltage, load current, battery current and temperature with time tag.
MegaPower MC2600

● ● ●A ●
◆6 ways AC volts ◆ Equalizing and floating charge of ◆ Boost Charge ◆ High/standard efficiency rectifiers
11 ways DC volts battery Temperature Compensation mixture management
4 ways Load currents Voltage regulating of rectifier or Battery Test Rectifiers running cyclic
2 ways Battery currents solar modules Low Voltage Disconnection Rectifiers running dormancy
3 ways Battery temperature Current limiting of rectifier or solar High Temperature
1 ways Ambient modules Disconnection
temperature On/Off control of rectifier or solar Battery Capacity Prediction
Rectifier modules modules
voltage/current 4 ways Load disconnect
Solar modules 1 way Battery disconnect
voltage/current


◆ SPD alarm ◆ Load disconnect ◆ Rectifier on/off status ◆ Battery charge over-current
Configurable digital input alarm Battery disconnect Solar communication fail Battery temperature alarm
Load fuse alarm AC power failure Solar fault Ambient temperature alarm
Battery fuse alarm Rectifier communication fail Solar fan fault Battery imbalance
Manual mode alarm Rectifier AC input failure Solar protect System energy-saving mode
Battery discharge Rectifier fault Solar on/off status Energy-saving fault
Current imbalance Rectifier fan fault AC over voltage and under voltage
Battery test fail Rectifier protect DC over voltage and under voltage

Site Monitoring Solution


Web Browser or Network/Site Management
Supervision SNMP Center
Center

Transmission
Network TCP/IP YDN23
Ethernet RS485 /RS232

DC Power System Distribution & Battery


MC2600
CAN
Site

Rect.1 Rect.2 Solar1 Solar2

You might also like