CellCrete 2080 MBS SCS
CellCrete 2080 MBS SCS
CellCrete 2080 MBS SCS
2. HAZARDS IDENTIFICATION
Classification of substance or mixture:
Eye Irritation Category 2A Serious Eye Irritant
Label elements: This material requires a hazard warning label in accordance with GHS criteria
Pictogram:
Hazard statement(s):
H319: Causes serious eye irritation.
Precautionary statement(s):
P264: Wash hands, arms and face thoroughly after handling.
P280: Wear protective gloves and eye/face protection.
5. FIREFIGHTING MEASURES
Suitable extinguishing media: Use extinguishing media suitable for surrounding fire
Unsuitable extinguishing media: Water jet
Specific hazards in case of fire: carbon dioxide, carbon monoxide, harmful vapors, nitrogen oxides,
fumes/smoke, carbon black
Special protective equipment required for firefighting: Wear self-contained breathing apparatus (SCBA)
Additional information for firefighters: None
Components with limit values that require monitoring at the workplace: None
Physical properties:
• pH value (@70°F): 6.00 – 9.00
• Specific gravity (@70°F): 1.010 – 1.050
• Bulk density: Not available
• Boiling point: 212°F / 100°C
• Freezing point/Melting point: 32°F / 0°C
• Decomposition temperature: Not available
• Vapor pressure: Not available
• Vapor density: Not available
• Evaporation rate: Not available
• VOC (w/w): 0%
• Solubility in / Miscibility with water: 100%
• Partition Coefficient (n-octanol/water): Not available
• Auto ignition: Material is not self-igniting
• Flash point: Material is non-flammable
• Lower / Upper Flammability Limits: Not applicable
• Viscosity: Not available
• Danger of explosion: material does not present an explosion hazard
Chronic toxicity: This product has not been tested for toxicity. Based on the properties of the individual
components, the classification criteria are not met.
• Repeated dose: based on available data, the classification criteria are not met
• Genetic: based on available data, the classification criteria are not met
• Carcinogenicity: based on available data, the classification criteria are not met
• Reproductive: based on available data, the classification criteria are not met
• Teratogenicity: based on available data, the classification criteria are not met
This information is based on our current knowledge and is furnished without warranty, representation,
or license of any kind, except that this information is accurate to the best of RussTech’s knowledge, or is
obtained from sources believed by RussTech to be accurate. No warranty is expressed or implied
regarding the accuracy of this information or the results to be obtained from its use thereof. RussTech
assumes no responsibility for injuries proximately caused by use of the Material if reasonable safety
procedures are not followed as stipulated in this Data Sheet. Additionally, RussTech assumes no
responsibility for injuries caused by abnormal use of the Material even if reasonable safety procedures
are followed. Buyer assumes the risk in its use of the Material.