10.control Panel
10.control Panel
10 Control Panel
10-1
Control panel
10-2
Control panel
10-3
Control panel
(ZERO POSITION MODE)Press this key and any manual control key,
then the corresponding axis will return to its reference position. When
this mode is selected, press the axis moving direction key, then the
machine will return to its machine reference position with the speed of
25% of G00(first reference position). The axis travel speed will slow
down when approaching to the reference position. When the reference
position indication lamp lights on, it means the axis has returned to its
reference position.
(JOG MODE)Press this key for moving each axis by using manual
control key.
(HANDLE MODE)Press this key, then you may use MPG handle to
move each axis. The axis direction and magnification are shown on the
handle panel.
Not available.
10-4
Control panel
execution, When this key is in OFF condition, M01 is ineffective.
When this key is pressed, during executing programs , any of M, S,T,
command cannot be executed.
When this switch is turned on, then any axis can not be moved.
When operation mode is set at jog or MPG handle mode, and the
magazine manual indication lamp lights on, press this key once, then
the magazine will clockwisely rotate a tool position. Keep pressing on
this key for continuous rotation of magazine. Release the key, then
the magazine rotation will stop.
When manual rotation of magazine is required, you need to set at jog
or MPG handle mode, and press this key. Then the magazine CW or
CCW manual will be effective.
When operation mode is set at jog or MPG handle mode, and the
magazine manual indication lamp lights on, press this key once, then
the magazine will counter-clcokwisely rotate a tool position. Keep
pressing on this key for continuous rotation of the magazine. Release
the key, then the magazine rotation will stop.
10-5
Control panel
This screen displays the actual tool numbers on the spindle and the
tool pocket. On an armless type magazine, the tool numbers displayed
for the spindle and the pocket are the same. However, on an arm type
magazine, the displayed tool numbers between both will be different.
Under any mode condition, when this key is pressed, the chip
conveyor will start running. Chip conveyor can also be started by
using the M code. For details refer to M code functions list.
Press this key for stopping the chip conveyor.
When this key is pressed, the chip conveyor starts running counter-
clockwisely. Release this key for stopping the chip conveyor. This
function is applied when chip jamming occurs.
Under jog or MPG handle mode, when this key is pressed, the spindle
starts running clockwisely.
Under any mode condition, when this key is pressed, the spindle stops.
Under jog or MPG handle mode, when this key is pressed, the spindle
starts running counter-clockwisely.
10-6
Control panel
Press this key for returning spindle speed to 100%.
Under jog mode, press any key on this area, then the axis will move
according to the speed set on the regulator knob for G01. If the rapid
traverse key is pressed, the axis will move with the speed set on the
regulator knob for G00.
The regulator knob is used for adjusting the G01 value during jog or
automatic operation mode. The adjustment range for G01 is 0-1260
mm/mm. or 0% -150 %. Another adjustment range 0% -200% is
available depending on the type of controller.
Under jog mode, press any key on this area, then the axis will move
according to the speed set on the regulator knob for G01. If the
rapid traverse key is pressed, the axis will move with the speed set
on the regulator knob for G00.
This regulator knob is used for adjusting the G01 value during jog
or automatic operation mode. The adjustment range for G01 is 0 –
1260 mm/mm or 0% - 150%. Another adjustment range 0%-200%
is available depending on the type of controller.
When the operation mode is set at jog mode
10-7
Control panel
During rapid traverse, you may adjust speed by turning this
regulator knob. Speed adjustment range is F0%, F25%, F50%and
F100%.
10-8
Control panel
When this key is pressed, the automatic lubricator shots oil. Release
this key, oil shot stops.
10-9
Control panel
magazine is in ready position.
When the lamp lights on, it means lubrication oil level is too low.
When the lamp lights on, it indicates the reference position for the
4th axis.
When X,Y,Z-axis indication lamps light on, it means axes are
located at the machine reference positions. (Any indication lamp for
X,Y,Z-axis lights on, it means the corresponding axis is located at its
reference position.
When second reference position indication lamp lights on, this
means the Z-axis is located at the tool changing position.
10-10
Control panel
10-11