Sine Wave Inverter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

This manual is important instruction that you should follow

during installation and maintenance of the inverter. Please


read all instructions before operating the equipment and save
this manual for future reference.
1. PRODUCTS SKETCH MAP
1
2. EP SERIES BASIC WIRING
2
3. LINE MODE SPECIFICATION
4
4. INVERTER MODE SPECIFICATION
5
5. CHARGE MODE SPECIFICATION
6
6. CHARGE MODE SPECIFICATION
7
7. DISPLAY & CONTROL
8
8. GENERAL SPECIFICATION
10
9. APPENDIX
11
User's manual User's manual

1. PRODUCTS SKETCH MAP 2. EP SERIES BASIC WIRING

Warning:High voltage,do not open


unless qualified to do so;
Please read instructions
before working on this
product.

Figure 1 top view


fuse

Main domestic battery bank ( 12V )

Figure 2 side view

Battery Battery
Negative Positive

CHARGER INPUT
PROTECTION

DC24V

INVERTER OUTPUT
PROTECTION
fuse
Remote Control

Earth
OUTPUT L N N L
INPUT OUTPUT

Figure 3 DC side Figure 4 AC side Main domestic battery bank ( 24V )

1 2
User's manual User's manual

3. LINE MODE SPECIFICATION

MODEL EP-1012 EP-2012 EP-2024 EP-3024 EP-4048 EP-6048

Input Voltage Waveform Sinusoidal(utility or generator)

Nominal lnput Voltage 230Vac

Low Line Disconnect 180Vac±4%

Low Line Re-connect 190Vac±4%

High Line Disconnect 265Vac± 4%

High Line Re-connect 255Vac±4%

Nominal lnput Frequency 50Hz/60Hz (Auto detection)

Main domestic battery bank ( 48V ) Low Line Frequency 58±0.3Hz for 60Hz;
Re-connect 45±0.3Hz for 50Hz;

Low Line Frequency 57±0.3Hz for 60Hz;


Disconnect 45±0.3Hz for 50Hz;
2
WHAT CABLE TO USE in mm :
High Line Frequency 64±0.3Hz for 60Hz;
Battery
Negative
Battery
Positive
Earthing A charger or inverter cable run distance cable run distance Re-connect 54±0.3Hz for 50Hz;
0-1.5m 1.5-4.0m
DC24V

125-180A 50 mm2 70 mm2 High Line Frequency 65±0.3Hz for 60Hz;


Disconnect 55±0.3Hz for 50Hz;
180-330 A 70mm2 90mm2
Remote Control

Output Voltage Waveform As same as lnput Waveform


Please note that if there is a problem obtaining for example
Earth
90 mm2 cable,use 2*50mm2,or 3*35mm2,One cable is always Over-Load Protection
Circuit breaker
best but,cables simply copper and all you require is the copper, (SMPS load)
Boat’s earth or bonding so it does not matter if it is one cable or 10 cables as long as Output Short Circuit
Circuit breaker
system or vehicle chassis the square area adds up.Performance of any product can Protection
be improved by thicker cable and shorter runs,so please
Efficiency(Line Mode) >95%
round up and keep the length as short as possible.
Transfer Time(AC to DC) ≤10ms(typical)

Input Output Transfer Time(DC to AC) ≤10ms(typical)


E L N N L E
CHARGER INPUT
PROTECT

AC I/O Connection
Remove cover plate
++++++
++++++
INVERTER OUTPUT
PROTECT

AC AC
OUTPUT L
INPUT
N N
OUTPUT
L Power in Power out

3 4
User's manual User's manual

4. INVERTER MODE SPECIFICATION 5. CHARGE MODE SPECIFICATION

HV MODEL HV MODEL
MODEL MODEL
EP-1012 EP-2012 EP-2024 EP-3024 EP-4048 EP-6048 EP-1012 EP-2012 EP-2024 EP-3024 EP-4048 EP-6048
Output Voltage Waveform Sine wave
Nominal Input Voltage 230Vac
Rated Output Power(VA) 1000 2000 3000 4000 6000
Input Voltage Range 180-250Vac
Rated Output Power(W) 1000 2000 3000 4000 6000
Power Factor 0~1.0 Nominal Output Voltage According to the battery type

Nominal Output Voltage(V) 230Vac Nominal Charge Current 45A(Max.)


Nominal Output Frequency(Hz) 50Hz±0.3Hz Charge Current Regulation ±5Adc
Yes(Following Main first connection)
Auto tracking Main Frequency(Hz) 50Hz@45-54Hz Charger Short Circuit
Circuit breaker
60Hz@55-64Hz Protection

Output Voltage Regulation ±10%rms Breaker Size Input:10A Input:15A Input:30A Input:35A Input:40A
Output:7A Output:10A Output:15A Output:20A Output:30A
Nominal Efficiency >80%
Over Charge Protection Bat.V≥15.7Vdc/31.4Vdc/62.8Vdc,beeps 0.5s every 1s &fault after 60s
(100%<load<120%)± 10%:Fault (shutdown output)after 2 minutes;
Over-Load Protection
(120%<load<140%)±10% :Fault (shutdown output)after 1 minutes, Charge Algorithm
(SMPS load)
Load>140%±10%:Fault (shutdown output)after 20s
Surge rating (10s) Three stage:
3000VA 6000VA 9000VA 1200VA 18000VA
Algorithm Boost CC (Constant current stage) Boost CV(constant voltage stage)
Capable of starting electric motor 0.5 HP 1 HP 2 HP 2 HP 3 HP Float(constant voltage stage)
Output Short Circuit Protection Current limit (Fault after 10s)

Inverter Breaker Size Input:10A Input:15A Input:30A Input:35A Input:40A


Output:7A Output:10A Output:15A Output:20A Output:30A
Nominal DC lnput Voltage 12V 12V 24V 24V 48V 48V

Min DC Start Voltage 10V/20V/40V


10.5Vdc±0.3Vdc for 12V battery
Low Battery Alarm 21.0Vdc±0.6Vdc for 24V battery
42.0Vdc±0.6Vdc for 48V battery
10.0Vdc±0.3Vdc for 12V battery
Low DC lnput Shut-down 20.0Vdc±0.6Vdc for 24V battery
40.0Vdc±0.6Vdc for 48V battery
16Vdc±0.3Vdc for 12V battery
High DC lnput Alarm &Fault 32Vdc±0.6Vdc for 24V battery
64Vdc±0.6Vdc for 48V battery
15.5Vdc±0.3Vdc for 12V battery
High DC lnput Recovery 31.0Vdc±0.6Vdc for 24V battery
62.0Vdc±0.6Vdc for 48V battery
Power saver <
Load =25W(Enabled on“P/S auto”setting of Remote control)

5 6
User's manual User's manual

6. CHARGE MODE SPECIFICATION 7.DISPLAY & CONTROL

① ② ③
ENTER
OPERATING STATUS DISPLAY 1
Boost CC Stage:If A/C input is applied,the charger will run at full
SAVE/GRN
currentin CC mode until the charger reaches the boost voltage.
2
Boost CV Stage: In this stage,the charger will keep the boost voltage
ON/MUTI
in Boost CV mode.The charging current will reduce,until less than 2A, ⑤
3
then drop the voltage down to the float voltage. ④ ⑥
CHR/CRT
Float Stage:In float mode,the voltage will stay at the float voltage.
If the A/C is reconnected or the battery voltage drops below 12Vdc/ 4
CHR/MOD
24Vdc/48Vdc,the charger wil reset the cycle above.
5
Charge Stage
FOR 24 VOLTS ⑧⑨ ⑩ ⑦ 11 12 13
Transition Definitions x2
15 C
14.5 1 3 H
A
Instruction of the LCD display
14 100 R
G
13.5 Item Indication Description
V
O 13
2 FLOAT 13.6V
E
R
L
T
S
12.5 1 50 C
%

Display of input voltage When the inverter is turned on,the LCD display shows input voltage,the input
and input frequency frequency of the display can be changed by switching the button.
12 4 U
11.5 2 3 R
R It shows the working status of the inverter. It shows "BYPASS"when the inverter
Working Status of
11
10.5
4 0
E
N
T

INVERTER
is in AC mode. It shows "INVERTER" when it is in the battery mode. It shows
TIME
"AVR" when it is in the "Boost Voltage" or " Buck Voltage" mode.
③ Display of output voltage When the inverter is turned on, the display shows the real output voltage.
STEP 1=CONSTANT CURRENT CHARGE STEP 2=ABSORPTTON CHARGE AT 14.4V Display of the Max.charging The inverter shows the Max.charging current when it is in the AC mode, It will
STEP 3=FLOAT VOLTAGE AT 13.6 VOLTS STEP 4=LOW VOLTAE RESET TO STEP 1 ④ current and charging mode shows the charging mode by switching the button.
When the inverter is turned on ,the display shows the real battery voltage.
Display of the battery
⑤ When the inverter is low battery,the buzzer beeps 0.5secs in every 5 secs,
voltage
Boost Float the display flashes and shows" LOW "with the beep.

Switch Voltage Voltage The display shows the load percentage. When the inverter is overload, the buzzer
Description beeps 0.5secs in every 1 sec, the display flashes and shows " OVER" with the beep.
setting Display of load
12V 24V 48V 12V 24V 48V ⑥ When the load is 100%-120%, the inverter will shut down after 2 minutes' alarm.
percentage
To be used by When the load is 120%-140%, the inverter will shut down after 1 minute's alarm.
0 When the load is >140%, the inverter will shut down after 20 secs alarm.
factory for set up
1 Gel USA 14.0 28.0 56.0 13.7 27.4 54.84 The display shows the current temperature of the heat sink. When the temperature
Battery Type Setting
2 AGM 1 14.1 28.2 56.4 13.4 26.8 53.6 Display of is ≥100℃, the buzzer will beep 0.5 secs in every 1 minute, the display will flashes
BATTERY TYPE SELECTOR ⑦ Temperature and show " HIGH" with the beep. When the temperature is ≥105℃, the inverter
3 AGM 2 14.6 29.2 58.4 13.7 27.4 54.8
4 Sealed lead acid will shut down for self-protection.
14.4 28.8 57.6 13.6 27.2 54.4
5 Gel EURO 14.4 28.8 57.6 13.8 27.6 55.2 ⑧ The fan is running The fan logo indicating inverter's fan is running.
6 Open lead acid 14.8 29.6 58.2 13.3 26.6 53.2 It shows the inverter is not in the silence mode. The silence function is inactive
⑨ Silence function when it is low battery, over load and over temperature.
7 Calcuim 15.1 30.2 60.4 13.6 27.2 54.4
8 De sulphation 15.5 31.0 62.0 4 hours then off ⑩ The battery is disabled It shows the battery is disabled, it needs to replace the battery.
9 Not used 11 Warning When the battery is over voltage, the buzzer beeps 0.5 secs every 1 second, the
display flashes with the beep.
It shows the “Power saver mode" is working. The inveter shut down the output
12 Power saver mode automatically when in the battery mode and without any load, inverter automaticly
has output when load is more then 40w.
13 Auto re-start It shows the inverter will be start when AC is connected.

7 8
User's manual User's manual

Function of the button

Item Function of the button Description 8. GENERAL SPECIFICATION


“OK” button for confirming the Max. Charging current or the charging
1 Enter button voltage mode .
When the inverter is working, the "Green mode button" can be opened Safety Certification CE(EN62040-1)
2 Green mode button or closed by short pressing on the button.
The inverter can be turned on or turned off by pressing the button for 3 EMC Classification En62040 - 2,C2
Start / silence function/ secs. In battery mode, the " silence function" can be ON/OFF by shortly
3 input frequency pressing the button. In AC mode, The input frequency will be displied by
shortly pressing the button. Operating Temperature
0℃ to 40℃
When the AC is normal, shortly press the button, the display will Range
Choosing the Max. keep flashing of "The maximum charging current value". Press
4
Charging current "ENTER” button for confirming this setting. If you did not press
"ENTER" button within 5 seconds, it will automatically return to the
Storage temperature -15℃ ~ 60℃
original setting of "maximum charging current value."
Operatio humidity 5% to 95%
5 Choosing the charging When the AC is normal, shortly press the button, the display will
keep flashing of "The charging voltage" for different tye of batteries.
voltage mode Press "ENTER” button for confirming this setting.If you did not press
"ENTER" button within 5 seconds, it will automatically return to the Audible Noise 60dB max
original setting of "charging voltage".
Cooling Forced air,variable speed fan

Fault recovery By restart the machine EP-1012,EP-2012,EP-2024,EP-3024:461mm*217mm*178mm


Size
EP-4048, EP-6048:636mm*217mm*179**mm
FAN Operation

Variable speed fan operation is required in invert and charge mode. This is
to be implemented in such a way as to ensure high reliability and safe unit
and component operating temperatures in an operating ambient temperature
up to 50℃.
Speed to be controlled in a smooth manner as a function of internal
temperature and/or current.
Fan should not start/stop suddenly.
Fan should run at minimum speed needed to cool unit.
Fan noise level target < 60db.

The fan logic as below:


Fan Operation
Condition Enter condition Leave condition Speed
T≤60℃ T>65℃ OFF
HEAT SINK T≤60℃ or T≥80℃ 50%
TEMPERATURE 65℃≤T<85℃
T>85℃ T≤80℃ 100%
T≤15% T≥20% OFF
Charge T≤15% or T≥50% 50%
Current 20%<T≤50%
T>50% T≤40% 100%
Load<30% Load≥30% OFF
Load%
(lnvert mode) 30%≤Load<50% Load≤20% or Load≥50% 50%
Load≥50% Load≤40% 100%

9 10
User's manual

9. APPENDIX

1.Indicator and Buzzer setting.

Status Item Buzzer

CC
Line Mode CV
Float

Inverter on
Invert Mode
Power saver

Battery Low beep 0.5s every 5s

beep 0.5s every 1s


Battery High

Alarm Mode Overload on invert mode Refer to"Instruction of the LCD display"

OverTemp on invert mode beep 0.5s every 1s

OverTemp on line mode beep 0.5s every 1s

beep 0.5s every 1s


Over charge

beep continuous
Fan lock

Battery High beep continuous

beep continuous
Inverter mode overload

Fault Mode beep continuous


OverTemp

beep continuous
Over charge

Back Feed Short beep continuous

11