Sine Wave Inverter
Sine Wave Inverter
Sine Wave Inverter
Battery Battery
Negative Positive
CHARGER INPUT
PROTECTION
DC24V
INVERTER OUTPUT
PROTECTION
fuse
Remote Control
Earth
OUTPUT L N N L
INPUT OUTPUT
1 2
User's manual User's manual
Main domestic battery bank ( 48V ) Low Line Frequency 58±0.3Hz for 60Hz;
Re-connect 45±0.3Hz for 50Hz;
AC I/O Connection
Remove cover plate
++++++
++++++
INVERTER OUTPUT
PROTECT
AC AC
OUTPUT L
INPUT
N N
OUTPUT
L Power in Power out
3 4
User's manual User's manual
HV MODEL HV MODEL
MODEL MODEL
EP-1012 EP-2012 EP-2024 EP-3024 EP-4048 EP-6048 EP-1012 EP-2012 EP-2024 EP-3024 EP-4048 EP-6048
Output Voltage Waveform Sine wave
Nominal Input Voltage 230Vac
Rated Output Power(VA) 1000 2000 3000 4000 6000
Input Voltage Range 180-250Vac
Rated Output Power(W) 1000 2000 3000 4000 6000
Power Factor 0~1.0 Nominal Output Voltage According to the battery type
Output Voltage Regulation ±10%rms Breaker Size Input:10A Input:15A Input:30A Input:35A Input:40A
Output:7A Output:10A Output:15A Output:20A Output:30A
Nominal Efficiency >80%
Over Charge Protection Bat.V≥15.7Vdc/31.4Vdc/62.8Vdc,beeps 0.5s every 1s &fault after 60s
(100%<load<120%)± 10%:Fault (shutdown output)after 2 minutes;
Over-Load Protection
(120%<load<140%)±10% :Fault (shutdown output)after 1 minutes, Charge Algorithm
(SMPS load)
Load>140%±10%:Fault (shutdown output)after 20s
Surge rating (10s) Three stage:
3000VA 6000VA 9000VA 1200VA 18000VA
Algorithm Boost CC (Constant current stage) Boost CV(constant voltage stage)
Capable of starting electric motor 0.5 HP 1 HP 2 HP 2 HP 3 HP Float(constant voltage stage)
Output Short Circuit Protection Current limit (Fault after 10s)
5 6
User's manual User's manual
① ② ③
ENTER
OPERATING STATUS DISPLAY 1
Boost CC Stage:If A/C input is applied,the charger will run at full
SAVE/GRN
currentin CC mode until the charger reaches the boost voltage.
2
Boost CV Stage: In this stage,the charger will keep the boost voltage
ON/MUTI
in Boost CV mode.The charging current will reduce,until less than 2A, ⑤
3
then drop the voltage down to the float voltage. ④ ⑥
CHR/CRT
Float Stage:In float mode,the voltage will stay at the float voltage.
If the A/C is reconnected or the battery voltage drops below 12Vdc/ 4
CHR/MOD
24Vdc/48Vdc,the charger wil reset the cycle above.
5
Charge Stage
FOR 24 VOLTS ⑧⑨ ⑩ ⑦ 11 12 13
Transition Definitions x2
15 C
14.5 1 3 H
A
Instruction of the LCD display
14 100 R
G
13.5 Item Indication Description
V
O 13
2 FLOAT 13.6V
E
R
L
T
S
12.5 1 50 C
%
①
Display of input voltage When the inverter is turned on,the LCD display shows input voltage,the input
and input frequency frequency of the display can be changed by switching the button.
12 4 U
11.5 2 3 R
R It shows the working status of the inverter. It shows "BYPASS"when the inverter
Working Status of
11
10.5
4 0
E
N
T
②
INVERTER
is in AC mode. It shows "INVERTER" when it is in the battery mode. It shows
TIME
"AVR" when it is in the "Boost Voltage" or " Buck Voltage" mode.
③ Display of output voltage When the inverter is turned on, the display shows the real output voltage.
STEP 1=CONSTANT CURRENT CHARGE STEP 2=ABSORPTTON CHARGE AT 14.4V Display of the Max.charging The inverter shows the Max.charging current when it is in the AC mode, It will
STEP 3=FLOAT VOLTAGE AT 13.6 VOLTS STEP 4=LOW VOLTAE RESET TO STEP 1 ④ current and charging mode shows the charging mode by switching the button.
When the inverter is turned on ,the display shows the real battery voltage.
Display of the battery
⑤ When the inverter is low battery,the buzzer beeps 0.5secs in every 5 secs,
voltage
Boost Float the display flashes and shows" LOW "with the beep.
Switch Voltage Voltage The display shows the load percentage. When the inverter is overload, the buzzer
Description beeps 0.5secs in every 1 sec, the display flashes and shows " OVER" with the beep.
setting Display of load
12V 24V 48V 12V 24V 48V ⑥ When the load is 100%-120%, the inverter will shut down after 2 minutes' alarm.
percentage
To be used by When the load is 120%-140%, the inverter will shut down after 1 minute's alarm.
0 When the load is >140%, the inverter will shut down after 20 secs alarm.
factory for set up
1 Gel USA 14.0 28.0 56.0 13.7 27.4 54.84 The display shows the current temperature of the heat sink. When the temperature
Battery Type Setting
2 AGM 1 14.1 28.2 56.4 13.4 26.8 53.6 Display of is ≥100℃, the buzzer will beep 0.5 secs in every 1 minute, the display will flashes
BATTERY TYPE SELECTOR ⑦ Temperature and show " HIGH" with the beep. When the temperature is ≥105℃, the inverter
3 AGM 2 14.6 29.2 58.4 13.7 27.4 54.8
4 Sealed lead acid will shut down for self-protection.
14.4 28.8 57.6 13.6 27.2 54.4
5 Gel EURO 14.4 28.8 57.6 13.8 27.6 55.2 ⑧ The fan is running The fan logo indicating inverter's fan is running.
6 Open lead acid 14.8 29.6 58.2 13.3 26.6 53.2 It shows the inverter is not in the silence mode. The silence function is inactive
⑨ Silence function when it is low battery, over load and over temperature.
7 Calcuim 15.1 30.2 60.4 13.6 27.2 54.4
8 De sulphation 15.5 31.0 62.0 4 hours then off ⑩ The battery is disabled It shows the battery is disabled, it needs to replace the battery.
9 Not used 11 Warning When the battery is over voltage, the buzzer beeps 0.5 secs every 1 second, the
display flashes with the beep.
It shows the “Power saver mode" is working. The inveter shut down the output
12 Power saver mode automatically when in the battery mode and without any load, inverter automaticly
has output when load is more then 40w.
13 Auto re-start It shows the inverter will be start when AC is connected.
7 8
User's manual User's manual
Variable speed fan operation is required in invert and charge mode. This is
to be implemented in such a way as to ensure high reliability and safe unit
and component operating temperatures in an operating ambient temperature
up to 50℃.
Speed to be controlled in a smooth manner as a function of internal
temperature and/or current.
Fan should not start/stop suddenly.
Fan should run at minimum speed needed to cool unit.
Fan noise level target < 60db.
9 10
User's manual
9. APPENDIX
CC
Line Mode CV
Float
Inverter on
Invert Mode
Power saver
Alarm Mode Overload on invert mode Refer to"Instruction of the LCD display"
beep continuous
Fan lock
beep continuous
Inverter mode overload
beep continuous
Over charge
11