ZPH 03
ZPH 03
(Model:ZPH03)
Manual
Version:1.1
Valid From:2020.08.15
This manual copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without the
written permission, any part of this manual shall not be copied, translated, stored in database or
retrieval system, also can’t spread through electronic, copying, record ways.
Thanks for purchasing our product. In order to let customers use it better and reduce the faults
caused by misuse, please read the manual carefully and operate it correctly in accordance with the
instructions. If users disobey the terms or remove, disassemble, change the components inside of
The specific such as color, appearance, sizes &etc, please in kind prevail.
We are devoting ourselves to products development and technical innovation, so we reserve the
right to improve the products without notice. Please confirm it is the valid version before using this
manual. At the same time, users’ comments on optimized using way are welcome.
Please keep the manual properly, in order to get help if you have questions during the usage in the
future.
Profile
This sensor integrates infrared PM2.5 detection technology,
using particle counting principle to detect PM2.5 in the
environment. It can detect the particles (diameter ≥1μm).
Features
*Good Stability for Long Time *Low Consumption *Good Anti-interference Performance
*High Sensitivity *Good Consistency
Applications
*Air purifier *Air refresher *Portable Instrumentation
*HVAC system *Air conditioner *Domestic and Commercial AC
Technical Parameters
Model ZPH03
Working voltage range 5±0.2 V (DC)
Output mode UART、PWM
Output signal voltage 4.5±0.2 V
Detection ability Smallest particles 1 μm diameter
Detection Range 4 ~ 500ug/m
Warm-up time ≤10s
Working Current ≤30mA
Humidity Storage ≤95%RH
range Working ≤95%RH(No condensation)
Temperature Storage -30℃~60℃
range Working 0℃~50℃
Size 46.0×32.0×18.3mm(L×W×H)
Physical interface ZH1.5mm-4P Connector Socket
Dimensions:
Fig 1
Fig 2
Fig 3
Fig 3
Pins Definition
Pins Definition
PIN1 GND
PIN2 VCC
PIN3 RXD
PIN4 TXD/PWM
Remarks
The ZPH03's two mode settings can only be performed before the sensor is normally powered on.
Please make a hardware connection in advance.
Application Circuit
Fig 5
Fig 6
Remarks:
The sensor has two output modes: PWM or UART, which are set in factory.
PWM Mode
In PWM mode, the sensor outputs PWM signal through PWM port (PIN 4). The PWM cycle is 1s,
and the dust concentration value is calculated according to the width of low level. The low pulse
width of PIN output corresponds to the average value of dust concentration. The value of
concentration was processed by software filtering, and the pulsation amplitude was relatively
small.
UART Mode
In serial mode, the sensor outputs serial data through TXD pin (PIN 4), the concentration value will be send
every other one second
The general serial port settings are as follows:
Cautions
1.Terms of Use
1.1 Installation Sketch
Min Φ9.0
3. Installation suggestions
2.1 the sensor should be installed in the air circulation position to avoid contact with organic
solvents;
2.2 recommended air velocity: (1.0 ~ 3) m / s; air volume: 0.004 ~ 0.01 CMM;
2.3 it is recommended to keep the sensor terminal downward;
2.4 it is recommended to add 3-5mm thick black breathable filter cotton at the air inlet side of the
sensor to prevent the accumulation of dust and other large particles;
2.5 it is recommended to keep away from high-frequency and high-voltage generator during
installation to prevent interference to the sensor;
2.6 it is recommended to install it at the backlight to prevent the sensor error from increasing due
to external light;
2.7 the sensor shell is conductive material and connected with circuit GND. GND pin should be
prevented from connecting into the system with voltage higher than the safety voltage of human
body, and it’s definitely it can’t be applied to the system involving human safety.