M3 - User Manual
M3 - User Manual
Measurement Features
• Patient demographics, measurement data and
trends, acquired and stored in the MMS, can be
transferred to the M-Series (M3/M4)3 and Philips
IntelliVue (MP60/MP70/MP90) patient
monitors.
• Multi-lead Arrhythmia.
PAD
Usability Features Display
The color display has a wide viewing angle, and
• Choice of serial interface for a dedicated external
strip chart recorder (as default), or IrDA interface excellent visibility from a distance, so you can easily
for connecting to a local printer. recognize and see the data you need for decision
making.
• 3-wave or 4-wave displays are available. For applications where a larger display is required, an
• Trend data, with manual and automatic event additional display can be connected to the monitor
storage, together with a range of report styles help via the standard VGA output (consult your Philips
you track and document your patient’s progress. representative for further information).
2
Monitor Environmental Specifications Interfaces
- Server link between monitor and measurement
Temperature Range (without wireless server
network interface)
- Network (RJ45)
Operating: - Infrared Interface to local printer
0 to 45°C (32 to 113°F). - Serial Interface to local recorder (supported
Storage:
recorder: GSI Lumonics XE-50p)
- Nurse Call relay (1/8" phone jack, ≤60W, ≤2A,
-20 to 60°C (-4 to 140°F).
≤36VDC, ≤25VAC, active=closed)
- ECG Output/Marker Input (1/4" stereo phone
Temperature Range (with wireless network
interface)
jack with tip, ring, sleeve)
ECG Output:
Operating:
Signal Gain: 320 to 3200 (depending upon ECG
0 to 35°C (32 to 95°F). display gain)
Storage:
Full Scale on Display: 3.2Vpp
-20 to 60°C (-4 to 140°F).
Gain Error: <20%
Humidity Range
Baseline Offset: <150mV
Operating:
Noise:<20mVRMS at signal gain 1000
95% RH max. @ 40°C (104°F)
Storage: Bandwidth: 1 to 80Hz in ECG Diagnostic mode
85% RH max. @ 50°C (122°F) Output Impedance:
<2.2KΩ ±20% ECG Output (ring)
Altitude Range <2.5kΩ ±20% ECG Output/Marker Input (tip)
Operating: Signal delay: <30ms
-500m to 4,600m
Marker Input Requirements:
(-1,600' to 15,000')
Signal Type: 0 to -12V, negative edge pulse.
Storage:
-500m to 13,100m Pulse Source Impedance: <7kΩ
(-1,600' to 43,000') Pulse Fall Time: <100µs
3
Battery (optional) Ordering Information
Moltech NJ1020HP Smart Battery, 3500mAh
(typical), Nickel-Metal-Hydride (removable). Also
Monitor Options
possible: Toshiba TR36, Duracell DR36 M3046A #A03
M3 with 3 wave channels.
Discharge Time: Supports C02 from M3015A Measurement Server
2.5h minimum [new and fully charged battery, Extension.
with NBP every 15 minutes, ECG, SpO2, and M3046A #A04
automatic reduction of display brightness.] M4 with 4 wave channels.
Supports C02 from M3015A Measurement Server
With a CO2 measurement in use, typically 15 Extension, and the Pressure/Temperature channel from
minutes shorter. M3012A Measurement Server Extension.
M3046A #C01
Charge Time (after connection to AC power):
Add enhanced arrhythmia capability
- typically 24h with monitor on and functioning.
M3046A #C15
- typically 4.5h with monitor off. Add basic network capability
Weight: M3046A #C16
600 g (1.3 lb.) Add full network capability
(requires #C15)
Real-time Clock M3046A #C40
Add battery.
Accuracy: M3046A #C90
<2 seconds per day. Software Revision D (works with M3000A, not with
M3001A). No local recorder support.
Operating Time:
M3046A #C91
6h without battery or AC power, otherwise Software Revision E (works with M3001A, not with
unlimited. M3000A). Support for local recorder M3080A #H20.
M3046A #J14
Active Settings and Stored Data Add IrDA Interface to connect to local printer
(you cannot also order M3046A #J16)
Operating Time:
M3046A #J16
6h without battery or AC power, otherwise Add Serial Interface to connect to local recorder
unlimited. (you cannot also order M3046A #J14; not compatible
with M3046A #C90)
Trends M3046A #J20
Add Wireless Network Interface
Short trend:
(requires #C15).
10 hours with 1 minute resolution. Complies with the requirements of the
Council Directive 1999/5/EEC of 9 0560
Long trend:
March 1999 (Radio and Telecommunications Terminal
48 hours with 5 minutes resolution. Equipment Directive)
Both trends are stored.
Monitor Mounting Options
M3080A #A10
Table Top Mount
M3080A #A11
Universal Hanger (including Table Top Mount)
M3080A #A13
Wall Rail
M3080A #A14
Tilt/Swivel Wall Mount
(includes wall rail)
M3080A #A15
GCX Wall Channel
M3080A #A21
Transport Bed Hanger
M3080A #A22
Roller Top Stand
M3080A #C05
Universal Pole Mount Clamp
M3080A #C06
Mounting Clamp for transport of Measurement Server
and Measurement Server Extension
M3080A #C10
4
Monitor Rail Mount Local Printer Options
M3080A #H05
Measurement Server Mounting Wireless Infrared Printer Connector
Options
M3080A #A01 Local Recorder Options
Measurement Server Mounting Plate For GSI Lumonics XE-50p:
(pack of five plates)
M3080A #H20
M3080A #A02
GSI Lumonics XE-50p Strip Chart Recorder
Rotating Clamp Mount (Software Revision E and Serial Interface connector
required)
Monitor Accessory Options M3080A #A30
Roller Stand Mount
M3080A #C12
Monitor carrying case M3080A #A31
Wall Mount
M3080A #C32
12V Adapter for use with a vehicle 12V power supply M4816A
(for CE countries only) Paper, 10 Rolls
[Original Equipment Manufacturer Product Number: M4817A
NotePower 75/NotePower 75i] Paper, 80 Rolls
M3080A #C40 M3081A #A70
Spare battery 1.0m serial recorder cable
5
Philips Medical Systems is part of Asia
Tel: +852 2821 5888
Royal Philips Electronics
Europe, Middle East, Africa
Interested? Tel: +31 40 27 63005
Would you like to know more about our
imaginative products? Please do not hesitate to Latin America
contact us. We would be glad to hear from you. Tel: +55 11 2125 0764
Via e-mail
© 1995-2005 Koninklijke Philips Electronics N.V.
[email protected] All Rights Reserved.
By postal service
Philips Medical Systems
Global Information Center
P.O Box 1168
5602 BD Eindhoven
The Netherlands
0366