GBXX Error Specification Nov 2016
GBXX Error Specification Nov 2016
B006-6524-A000
Issue 6
Nov 2016
Copyright and Trademark Information
The products described in this document are copyrighted works of NCR Corporation.
Disclaimer:
It is the policy of NCR Corporation to improve products as technology, components, software and firmware become available. NCR
therefore reserves the right to change specifications without prior notice.
All features, functions and operations described herein may not be marketed by NCR in all parts of the world. In some instances,
photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR
office for information that is applicable and current.
To maintain the quality of our publications, we need your comments on the accuracy, clarity, organisation and value of this book.
A A
C C
D D
E E
This specification describes the error code of Global Bunch Note Acceptor (hereinafter “GBNA”)
and Global Bill Recycle Unit (hereinafter “GBRU”).
XXXX + YY + ZZ
Command code + Category + Detail
When an error occurs, Category and Detail include an error code are displayed on the 7 segments LED display
located in the Upper PCB board as shown in below.
1 second
Y. Y.
Blink 0.5 seconds 2 seconds
1 second
Z. Z.
When the command is received from host, stops to display an error code.
0 1 2 3 4 5 6 7 8 9 A B C D E F H -
code substance
00 generally *
generally *
* : The code is changed when ST swich is pushed for 3 seconds. (Dispense enable switch)
H0 checking sum value of IPL-program
H1 checking inside memory
H2 checking external memory
H3 checking BOOT-program
H4 checking file-system
-0 BOOT-program deficit
-1 Main-program deficit
-2 downloading by USB
-3 downloading by SCI
-4 system down
-5 defect of file-system
-6 parity error
-7 memory error
-8 undefined interrupt
-9 general illegal instructions/illegal slot instructions
-A address error
-B NMI/watch dog error
-C sum error for main-program
-D sum error for BOOT-program
-E send error on USB
-F sum error for IPL-program
1311 <Host Interface>unjust parameter H0(BOOT) A Block number of LD or LE commands was an unexpected value H or C LPCB USB 313,314
in BOOT program.
1500 <Host Interface>Receive invalid command Received an invalid command. H or C LPCB USB 313,314
1600 <Host Interface>unjust data classification of data Classification of data was invalid when receiving a command. H or C LPCB USB 313,314
1601 <Host Interface>unjust data length Frame Length was less than 6 bytes when receiving a command. H or C LPCB USB 313,314
Frame Length exceeded the maximum length when receiving a
command.
Frame Length was smaller than Message Length when receiving a
command.
Message Length was not equal to the sum of Message Header and
Data Block when receiving a command.
1602 <Host Interface>unjust data format Message Header of a received command contained an invalid H or C LPCB USB 313,314
value.
1603 <Host Interface>unjust number of data block Number of data block was invalid when receiving a command. H or C LPCB USB 313,314
1604 <Host Interface>unjust data sum The sum of a command received did not match. H or C LPCB USB 313,314
1620 <Host Interface>unjust parameter A1 Parameter A1 was set to an invlalid value when receiving a S or H LPCB 013
command.
1621 <Host Interface>unjust parameter A2 Parameter A2 was set to an invlalid value when receiving a S or H LPCB 013
command.
1622 <Host Interface>unjust parameter A5 Parameter A5 was set to an invlalid value when receiving a S or H LPCB 013
command.
1623 <Host Interface>unjust parameter A6 Parameter A6 was set to an invlalid value when receiving a S or H LPCB 013
command.
1626 <Host Interface>unjust parameter A9 Parameter A9 was set to an invlalid value when receiving a S or H LPCB 013
command.
1627 <Host Interface>unjust parameter AZ Parameter AZ was set to an invlalid value when receiving a S or H LPCB 013
command.
1628 <Host Interface>unjust parameter H0 Parameter H0 was set to an invlalid value when receiving a S or H LPCB 013
command.
1629 <Host Interface>unjust parameter A0 Parameter A0 was set to an invlalid value when receiving a S or H LPCB 013
command.
162B <Host Interface>unjust parameter P1 Parameter P1 was set to an invlalid value when receiving a S or H LPCB 013
command.
162C <Host Interface>unjust parameter P2 Parameter P2 was set to an invlalid value when receiving a S or H LPCB 013
command.
162D <Host Interface>unjust parameter P3 Parameter P3 was set to an invlalid value when receiving a S or H LPCB 013
command.
162E <Host Interface>unjust parameter P0 Parameter P0 was set to an invlalid value when receiving a S or H LPCB 013
command.
162F <Host Interface>unjust parameter A4 Parameter A4 was set to an invlalid value when receiving a S or H LPCB 013
command.
1630 <Host Interface>unjust parameter AF Parameter AF was set to an invlalid value when receiving a S or H LPCB 013
command.
1640 <Host Interface>abnormalities in download sequence LE command was received prior to LD command. S or H LPCB 013
16F0 <Host Interface>Not available RAS command The specified RAS command is not available. S or H LPCB 013,017,307
1700 <Host Interface>un-setting parameter A1 A1 parameter not specified yet when receiving a command that H LPCB 013
requires A1 parameter.
1800 <Host Interface>Invalid encryption The encryption was invlalid when receiving a command. S or H LPCB 013,017,307
1801 <Host Interface>No parameter AF There was no parameter AF when receiving a command. S or H LPCB 013,017,307
1C00 <Host Interface>Un-setting payment password. Password for dispense not entered when starting RAS. O Operatipon 015
1C01 <Host Interface>Un-setting calculation password. Password for counting not entered when starting RAS. O Operatipon 015
1E00 <USB>USB connector pull out USB VBUS signal was found low during command processing. H or C LPCB USB 313,314,307
1E01 <USB>USB bus reset detect USB bus reset was detected during command processing. H or C LPCB USB 313,314,307
1E02 <USB>Timeout of USB transmission. Could not transmit a response within the specified time. H or C LPCB USB 313,314,307
2*** relate with BV Error
2001 <Firmware>It cannot receipt request data that it is BV task was already in operation when requesting to BV task. S or H BV LPCB 013
under bill validation.
2004 <BV>Timeout of BV response. No response sent from BV within the specified time when H or C BV LPCB BV LAN 315-318,011,307
requesting a command.
2005 <BV>unjust BV data sum The sum of a response received from BV did not match. H or C BV LPCB BV LAN 315-318,011,307
2006 <BV>unjust BV data length Data length invalid when receiving a response from BV. H or C BV LPCB BV LAN 315-318,011,307
2007 <BV>BV reset failure Received a response other than reset command after sent a reset H BV LPCB 315-318,011,307
command to BV.
No response informed by BV within the specified time resulting in
timeout when BV was requested a reset command.
There occured an alarm other than BV cover open/Note remain at
Alarm read command after BV reset command.
2100 <BV>There is no response from BV RR command did not returned from BV after sending TEST H or C BV LPCB BV LAN 315-318,011,307
command. or BPWR
RR command did not returned from BV after sending a command.
Could not send by LAN LSI error when sending a packet to BV.
Lan task was Initialize state when sending a command to BV.
2300 <BV>Over VD from BV. Number of validation data exceeded number of notes detected at H BV 315-318,011
BVIN during note validation.
25** <BV>BV unit failure. ( ** : 2digit in VD error code. xx Received validation data during bill validation that indicates H or S BV 001,002,004,304,31
in VD data'9Exx' ) further validation impossible. 5-318,011
2501 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2502 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2503 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2504 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2505 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2507 <BV>BV system error Internal interface error S BV 001,002,004,304,31
5-318,011
2508 <BV>BV system error No response in discrimination parts S BV 001,002,004,304,31
5-318,011
2509 <BV>BV system error Power error S BV 001,002,004,304,31
5-318,011
250A <BV>BV Check Note Error Error of medium S BV Check Note 001,002,004,304,31
< Only when BV Chcek Note is used, this is detected. > 5-318,011
250F <BV>BV system error Recalibration error S BV BV Check Note 001,002,004,304,31
< Only when BV Chcek Note is used, this is detected. > 5-318,011
2510 <BV>Validation mode specified error During validation S or H BV FW BV 001,002,004,304,31
Download 5-318,011
2511 <BV>Template error Template for notes S or H BV FW BV 001,002,004,304,31
<The discrimination of the test note was directed. > Download 5-318,011
2512 <BV>Template error Template for test notes S or H BV FW BV 001,002,004,304,31
<The discrimination of the note was directed. > Download 5-318,011
2513 <BV>Template error invalid validation parameter S or H BV 001,002,004,304,31
5-318,011
3201 <Cassettes>Temporary cassette is not a recycling type. Deposit cassette was specified as a Temporary cassette at S SW setting 005
reconciliation.
3210 <Cassettes>Temporary cassette cannot be specified to Temporary cassette was specified as a Target cassette at S SW setting 005
be a target cassette. reconciliation.
3300 <Cassettes>There is no Temporary cassette. No temporary cassette was specified at reconciliation. S SW setting 005
3310 <Separator>There is no note in Separator. Separator was empty in RAS-C1,C2,C3 operation. O Operation 015
3400 <Cassettes>The medium remains to temporary cassette. Notes remained in Temporary cassette at reconciliation. S SW setting 005
3411 <Pre-Acceptor>The medium which should be extracted Notes detected in Pre-acceptor after shutter close operation H PA SHT 001,002
remains to pre-acceptor. completed at TO/AP command.
3412 <Cassette Transport>The medium remains to knot URHS sensor remained blocked when clearing jam error after O or H Operation CAS URHS 001,002
portion between upper unit and lower unit (rear). pulling out the lower unit and returning it to the mounting position
again for jam recovery.
3413 <Transport before BV>The medium remains to knot LFHS sensor remained blocked when clearing jam error after O or H Operation BV LFHS 001,002
portion between upper unit and lower unit (front). pulling out the lower unit and returning it to the mounting position
again for jam recovery.
3414 <Cassette Transport>The medium remains to lower Clearing jam error after pulling out the lower unit and returning it O or H Operation LT URHS,LT3S, 001,002
unit. to the mounting position again for jam recovery. LFHS,UFHS
3500 <Separator Transport>Not detect home position of SCDC and SHDC sensors were not cleared within the specified H SEP SCDC,SHDC SEDM 101-108,301-307
deskew lever time when moved deskew roller to home position at MR, MJ
commands.
3501 <Separator Transport>Not detect right position of SCDC sensor was not blocked or SHDC sensor was not cleared H SEP SCDC,SHDC SEDM 101-108,301-307
deskew lever within the specified time when moved deskew roller to right.
3502 <Separator Transport>Not detect left position of SCDC sensor was not cleared or SHDC sensor was not blocked H SEP SCDC,SHDC SEDM 101-108,301-307
deskew lever within the specified time when moved deskew roller to left.
4006 <Cassette 2>Cassette 2 was not set. Cassette 2 was not set at the start of a command. H or O CAS2 LB 005,006,301-
307,309
4007 <Cassette 3>Cassette 3 was not set. Cassette 3 was not set at the start of a command. H or O CAS3 LB 005,006,301-
307,309
4008 <Cassette 4>Cassette 4 was not set. Cassette 4 was not set at the start of a command. H or O CAS4 LB 005,006,301-
307,309
4009 <Transport before BV>Transport before BV was not Transport in front of BV was not set at the start of a command. H or O BV URCN SBLC 004,301-307
set.
400A <Transport under Reject bin>Transport under Reject Transport under Reject bin was not set at the start of a command. H or O UT UGLC 004,301-307
bin was not set.
6103 <Carrier>Carrier drags notes on Bunch transport. When Carrier moved backward, ECCC sensor was blocked and J ESC PAC or SEP SE3 ECCC/EELS/ 101,102,103,104,21
EELS sensor or EERS sensor was blocked. EERS 0,211,213,301-
307,312
6120 <Pre-Acceptor>Tray doesn't move forward. PDPC sensor was not blocked within the specified time when Tray J or H PAC SE7 PDPC/PRPC/ PATM 001,002,010,101-
moved forward. PTPC 108,201,203,216,21
Step-out was detected at PTPC sensor before 8,301-307
PS1S/PS2S/PS3S/PS4S sensors were blocked when Tray was
moving forward.
Step-out was detected at PTPC sensor before PDPC sensor was
blocked when Tray was moving forward.
Step-out was detected at PTPC sensor when Tray was moving
forward by a specified number of steps.
6121 <Pre-Acceptor>Tray doesn't move backward. PLPC sensor was not blocked within the specified time when Tray J or H PAC SEP SE7 PDPC/PRPC/ PATM 001,002,010,101-
moved backward. PTPC 108,201,203,216,21
PRPC sensor was not blocked within the specified time when Tray 8,301-307
moved backward.
Step-out was detected at PTPC sensor before PRPC sensor was
detected when Tray was moving backward.
Step-out was detected at PTPC sensor before PLPC sensor was
detected when Tray was moving backward.
Step-out was detected at PTPC sensor when Tray was moving
backward by a specified number of steps.
6130 <Pre-Acceptor>Belt doesn't move forward. Step-out was detected at PBPC sensor when Belt was rotating H or J PAC Cable SE7 PBPC PABM 001,002,010,101-
forward. 108,201,202,205,21
4-216,220,301-307
6131 <Pre-Acceptor>Belt doesn't move backward. Step-out was detected at PBPC sensor when Belt was rotating H or J PAC Cable SE7 PBPC PABM 001,002,010,101-
backward. 108,2001,202,205,2
14-216,221,301-307
6141 <Pre-Acceptor>Clamp doesn't move upward. PTHC sensor was not cleared within the specified time when J or H PAC SEP SE7 PTHC/POLC PACM 001,002,010,101-
Clamp moved up. 109,214-
216,220,221,301-
307
6150 <Pre-Acceptor>Pre-Acceptor Connector doesn't Pre-acceptor connector removal detected when requesting Pre- S or C PAC and Cable FW version PA1 301,302,307
connect. Acceptor to move. or UPCB
6151 <Pre-Acceptor>Pre-Acceptor type doesn't right. Invalid Pre-Acceptor type signal detected when requesting Pre- S or C PAC and Cable FW version PA1 301,302,307
Acceptor to move. or UPCB
6180 <Separator>Pusher doesn't move downward. SPPC sensor was not cleared within the specified time when J or H SEP Cable or PAC SE5 SPPC/SPCC/ SEPM/PDM 001,002,101-
Separator Pusher moved down. PDAC G 108,111,210-
SPCC sensor was not blocked within the specified time when 212,221,301-307
Separator Pusher moved down.
6181 <Separator>Pusher doesn't move upward. SPUC sensor was not blocked within the specified time when J or H SEP Cable or PAC SE5 SPUC/SPBC SEPM 001,002,101-
Separator Pusher moved up. 108,111,210-
SPBC sensor was not blocked within the specified time when 212,221,301-307
Separator Pusher moved up.
6190 <Separator>Stage doesn't move downward. SSLC sensor was not blocked within the specified time when J or H SEP SE5 SSLC SESM 001,002,101-
Separator Stage moved down. 108,111,210-
212,221,301-307
6191 <Separator>Stage doesn't move upward. SSUC sensor was not blocked within the specified time when J or H SEP SE5 SSUC SESM 001,002,101-
Separator Stage moved up. 108,111,210-
212,221,301-307
61A0 <Shutter>Shutter doesn't open after several retry. Shutter Open sensor was not blocked within the specified time H SHT PAC or cable SHT Shutter Open Shutter motor 001,002,004,008,10
when Shutter opened. 9,116,301-307
61A1 <Shutter>Shutter doesn't close after several retry. Shutter Close sensor was not blocked within the specified time H SHT PAC or cable SHT Shutter Close Shutter motor 001,002,004,008,10
when Shutter closed. 9,116,301-307
61B1 <Shutter>Shutter doesn't close. Shutter was not closed at the start of SK command. H SHT PAC or cable SHT Shutter 001,002,004,008,10
Open/Shutter 9,116,301-307
Close
6210 <Carrier>Two or more sensor change was detected ECHC/ECCC/ECPC/PCEC sensors were following impossible H or J ESC PAC or SEP ES3 ECHC/ECPC 001,002,301-
simultaneously.(ECHC/ECCC/ECPC/PCEC) state at the start of mechanical operating. /ECCC/PCE 307,311,312
ECHC sensor : blocked & ECCC sensor : cleared & ECPC sensor : C
cleared & PCEC sensor : blocked
6211 <Carrier>Two or more sensor change was detected ECHC/ECCC/ECPC sensors were following impossible state at H or J ESC SEP or PAC ES3 ECHC/ECCC 001,002,301-
simultaneously.(ECHC/ECCC/ECPC) the start of mechanical operating. /ECPC 307,311
ECHC sensor : blocked & ECCC sensor : cleared & ECPC sensor :
cleared
6611 <Pre-Acceptor>Media detection outside Tray after PDSS sensor was blocked after moving the media to Pre-Acceptor J or H PAC PA3 PDSS 001,002,010,101-
moving the media to Pre-acceptor and moving Tray forward a little. 108,201,202,205,20
6,218,219,221,301-
307
6612 <Pre-Acceptor>Media detection outside Separator During Pre-acceptor preparation for moving the media from J or H PAC PA3 PDSS 001,002,010,101-
during Pre-acceptor preparation Seprator to Pre-acceptor, PDSS sensor was blocked after moving 108,201,202,205,20
Tray forward a little because D-Stopper did not escape. 6,218,219,221,301-
307
6613 <Pre-Acceptor>Belt slipped and a medium has not PDSS sensor did not become clear within the specified time when J or H PAC SEP (Stage) or PA3 or SE7 PDSS PABM 001,002,010,101-
been moved to Pre-acceptor. notes were transported to Pre-acceptor using Belt. ESC (Carrier) or PA1 108,201,202,205,20
6,218,219,221,301-
307
6614 <Pre-Acceptor>Belt slipped and a medium has not PDSS sensor did not become clear within the specified time when J or H PAC PA3 or SE7 PDSS PABM 001,002,010,101-
been moved to Separator. notes were transported to Separator using Belt. or PA1 108,201,202,205,20
6,218,219,221,301-
307
6615 <Pre-Acceptor>Media detection outside Separator after PDSS sensor was blocked after moving the media to Separator and J or H PAC PA3 or PA1 PDSS PATM 001,002,010,101-
moving the media to Separator moving Tray forward a little. 108,201,202,205,20
6,218,219,221,301-
307
6616 <Pre-Acceptor>Media detection at the front of Pre- PS1S/PS2S/PS3S/PS4S sensor were blocked when Tray was J or H PAC PA3 PS1S/PS2S/P 001,002,010,101-
acceptor before Tray was moved backward moved backward. S3S/PS4S 108,201,202,205,20
6,218,219,221,301-
307
6617 <Pre-Acceptor>Media detection at the front of Pre- PS1S/PS2S/PS3S/PS4S sensor were blocked when Tray was J or H PAC PA3 PS1S/PS2S/P 001,002,010,101-
acceptor before Tray was moved forward moved forward. S3S/PS4S 108,201,202,205,20
6,218,219,221,301-
307
6618 <Pre-Acceptor>Media detection at the front of Pre- PDPC sensor was not blocked though Tray was moved forward a J or H PAC PA3 or PA1 PS1S/PS2S/P PATM 001,002,010,101-
acceptor, or Tray doesn't move forward little because PS1S/PS2S/PS3S/PS4S sensors had blocked. S3S/PS4S 108,201,202,205,20
6,218,219,221,301-
307
661A <Pre-Acceptor>Media remains at Pre-acceptor. PHPC sensor was not blocked when Hook was thrusted in the J or H PAC RV2PH or PHPC PAMG 001,002,010,101-
media remaining check processing. PA1 108,201,202,205,20
6,217,218,219,301-
307
661B <Pre-Acceptor>Media remains at Pre-acceptor. PS1S/PS2S/PS3S/PS4S/PTCS sensors were blocked in the media J or H PAC PA3 PS1S/PS2S/P 001,002,010,101-
remaining check processing. S3S/PS4S/PT 108,201,202,205,20
CS 6,218,219,221,301-
307
661C <Pre-Acceptor>Media remains at Pre-acceptor. PS1S/PS2S/PS3S/PS4S/PTCS sensors were blocked after Hook/D- J or H PAC PA3 PS1S/PS2S/P 001,002,010,101-
stopper escape in the media remaining check processing. S3S/PS4S/PT 108,201,202,205,20
CS 6,217,218,219,221,3
01-307
661D <Pre-Acceptor>Media detection at the rear of Pre- PDSS sensor was blocked after moving the media to Separator J or H PAC PA3 or PA1 PDSS PABM 001,002,010,101-
acceptor after moving the media to Separator (PDSS sensor was cleared) and moving Belt backward a little in 108,201,202,205,20
the retry processing. 6,218,219,221,301-
307
661E <Pre-Acceptor>Media detection at the rear of Pre- PDSS sensor was blocked after moving the media to Separator J or H PAC PA3 PDSS 001,002,010,101-
acceptor after moving the media to Separator (PDSS sensor was cleared) and moving Clamp up in the retry 108,201,202,205,20
processing. 6,218,219,221,301-
307
6700 <Pre-Acceptor>Hook doesn't escape at Pre-acceptor. PHPC sensor was not blocked after waiting the specified time J or H PAC RV2PH PHPC PHMG, 001,002,010,101,10
when PHMG solenoid switched off. PDMG 2,107,217,220,221,3
01-307
6701 <Pre-Acceptor>Hook doesn't thrust at Pre-acceptor. PHPC sensor was not cleared after waiting the specified time J or H PAC RV2PH PHPC PHMG 001,002,010,101,10
when PHMG solenoid switched on. 2,107,217,220,221,3
01-307
6702 <Pre-Acceptor>D-stopper doesn't thrust at Pre- PDAC sensor was not blocked after waiting the specified time J or H PAC PDACor PA1 PDAC PDMG 001,002,010,101,10
acceptor. when PDMG solenoid switched on. 2,107,220,221,301-
307
6703 <Pre-Acceptor>D-stopper doesn't escape at Pre- PDAC sensor was not blocked after waiting the specified time J or H PAC PDACor PA1 PDAC PDMG 001,002,010,101,10
acceptor. when PDMG solenoid switched off. 2,107,220,221,301-
307
6710 <Pre-Acceptor>Hook doesn't escape at Pre-acceptor. PHPC sensor was not cleared after waiting the specified time J or H PAC RV2PH PHPC PAMG 001,002,010,101,10
when PAMG solenoid switched off. 2,107,217,301-307
6720 <Pre-Acceptor>Hook doesn't thrust at Pre-acceptor. PHPC sensor was not blocked after waiting the specified time J or H PAC RV2PH PHPC PAMG 001,002,010,101,10
when PAMG solenoid switched on. 2,107,217,301-307
6730 <Pre-Acceptor>D-stopper doesn't thrust at Pre- PDAC sensor was not cleared after waiting the specified time J or H PAC PDACor PA1 PDAC PHMG 001,002,010,101,10
acceptor. when PHMG solenoid switched on. 2,107,221,301-307
6731 <Pre-Acceptor>D-stopper doesn't thrust at Pre- PDAC sensor was not cleared after waiting the specified time J or H PAC PDACor PA1 PDAC PHMG 001,002,010,101,10
acceptor. when PHMG solenoid switched on.(After moving the media to the 2,107,221,301-307
Separator)
6740 <Pre-Acceptor>D-stopper doesn't escape at Pre- PDAC sensor was not blocked after waiting the specified time J or H PAC PDACor PA1 PDAC PHMG 001,002,010,101,10
acceptor. when PHMG solenoid switched off. 2,107,221,301-307
6750 <Pre-Acceptor>D-stopper fell during the Belt was PDAC sensor was cleared during the Belt was rotated to J or H PAC PDACor PA1 PDAC PHMG 001,002,010,101,10
rorated to backward. backward. 2,108,221,301-307
6800 <Separator>Separator doesn't feed backward. SFPC sensor was not cleared within the specified time when J or H SEP SE5 or SE4 SFPC SEFM 002,101-108,301-
SEFM motor rotated back. 307
6900 <Pre-Acceptor>Note remain in Pre-acceptor. PDSS sensor was not cleared after transport notes to Separator J or H PAC SEP PA3 or PA1 PDSS PDMG 010,104,201,202,21
from Pre-acceptor. 4-218,220,221,301-
307
6C00 <Pre-Acceptor>Note disappear from sensor.(PDSS) PDSS sensor was not blocked when Carrier moved until PCEC J or H PAC SEP or PA3 PDSS 001,010,301-307
sensor was blocked. ESC (Carrier)
6C02 <Pre-Acceptor>Note disappear in Pre-acceptor The medium disappeared at the time of moving to the point of Pre- J or H PAC SEP PA3 or SE7 PDPC/PTCS/ 001,010,301-307
acceptor, and Tray detected the PDPC sensor PS1S/PS2S/P
S3S/PS4S
6C11 <Pre-Acceptor>Notes disappeared from Pre-acceptor. Separator was empty when they were transported to Separator J or H PAC SEP PA3 or SE7 SSEC 001,010,301-307
from Pre-accceptor. or SE5 PTCS/PS1S/
PS2S/PS3S/P
S4S
6C21 <Separator>Notes disappeared from Separator. Separator was empty though there was note in Separator. J or H SEP SE5 SSEC 001,010,301-307
6F70 <Pre-Acceptor>Pre-acceptor fails to draw notes. PASS/PTCS/PS1S/PS2S/PS3S/PS4S sensors were blocked after J or H PAC SHT PA3 or SE7 PBPC/PTPC/ PATM,PAB 001,002,010,101-
drawing notes from Pre-acceptor top. or PA1 PASS/PTCS/ M 108,201-
PDSS 203,205,214-
216,218,301-307
6F71 <Pre-Acceptor>Pre-acceptor fails to prepare for PLPC sensor was not blocked when notes were drawn into Pre- J or H PAC RV2PH or PLPC/PRPC PATM,PAB 001,002,010,101-
drawing notes. acceptor until PRPC sensor was blocked. SE7 or PA1 M 108,201-
203,205,214-
216,218,301-307
6F80 <Separator>Separator doesn't feed note. SSRS/SSLS/SSOS sensors were not blocked within the specified J or H SEP SE5 or SE4 SFPC/SSEC/ SEFM 002,010,101-
time when picked up notes from Separator. SPPC/SPCC 108,203-206,301-
307
6F81 <Separator>Separator doesn't confirm empty. The empty was detected when transporting notes from Separator, J or H SEP SE5 or SE4 SFPC/SSEC/ SEFM 101-109,210-
but it was not empty when operating the mechanism after that. SPPC/SPCC 212,301-307
6F83 <Separator>The number of not recognized notes in The number of not recognized notes reached the maximum H BV SEP 001,002,010,011,01
Separator was exceeded. number while notes were transported from Separator. 2,203-
206,302,303,304,30
7,308
6F84 <Separator>The number of damaged notes in Separator The number of damaged notes reached the maximum number H BV SEP 001,002,010,011,01
was exceeded. when notes were transported from Separator. 2,203-
206,302,303,304,30
7,308
6F86 <Separator>The number of counterfeit notes in The number of counterfeit notes reached the maximum number H BV SEP 010,011
Separator was exceeded. when notes were transported from Separator.
6F88 <Separator>The number of suspect note / counterfeit The number of suspect note / counterfeit notes reached the H BV SEP 010,011
notes in Separator was exceeded. maximum number when notes were transported from Separator.
7*** Mechanical error at Escrow & Reservoir
7100 <Reservoir>Reservoir doesn't move downward. ERLC sensor was not blocked within the specified time when J or H ESC ES1 or ES2 ERLC/ERRC ERSM 001,002,010-
Reservoir Stage moved down. 108,111,114,115,20
ERRC sensor was not blocked within the specified time when 5,206,210-213,301-
Reservoir Stage moved down. 307
7101 <Reservoir>Reservoir doesn't move upward. ERRC sensor was not blocked within the specified time when J or H ESC ES1 or ES2 ERRC/ERUC ERSM 001,002,010-
Reservoir Stage moved up. 108,111,114,115,20
ERUC sensor was not blocked within the specified time when 5,206,210-213,301-
Reservoir Stage moved up. 307
7180 <Escrow>Escrow doesn't move downward. EEUC sensor was not blocked within the specified time when J or H ESC ES3 or ES2 EEUC/ETRS/ EESM 001,002,010-
Escrow Stage moved down. ETLS 108,111,113,205,20
ETRS/ETLS sensors were not blocked within the specified time 6,210-213,301-307
when Escrow Stage moved down.
ETRS/ETLS sensors were not cleared within the specified time
when Escrow Stage moved down.
7181 <Escrow>Escrow doesn't move upward. EERC sensor was not blocked within the specified time when J or H ESC ES1 or ES2 EERC EESM 001,002,010-
Escrow Stage moved up. 108,111,113,205,20
6,210-213,301-307
7200 <Reservoir>Unjust position Escrow. ERUC sensor was already blocked when trying to move Reservoir H ESC ES1 ERUC/ERRC 210-212,301-307
Stage to ERRC sensor.
7201 <Reservoir>Illegal detected sensor. ERLC sensor was blocked when Reservoir Stage moved down to H ESC ES1 ERLC/ERRC 301-307
ERRC sensor.
7202 <Reservoir>Two or more sensor change was detected ERUC/ERRC/ERLC sensors were following impossible state at H or J ESC ES1 ERUC/ERRC 301-307,311
simultaneously.(ERUC/ERRC/ERLC) the start of mechanical operating. /ERLC
ERUC sensor : blocked & ERRC sensor : blocked & ERLC sensor
: blocked
7203 <Reservoir>Two or more sensor change was detected ERUC/ERRC sensors were following impossible state at the start H or J ESC ES1 ERUC/ERRC 301-307,311
simultaneously.(ERUC/ERRC) of mechanical operating.
ERUC sensor : blocked & ERRC sensor : blocked
81FF <Cassette1>Cassette cannot be used. Because the error occurred before, the cassette cannot be operated. H or J CAS1 CM1 or Cable CS1 or LB1 CT1S/CP1C/ BS1M/BF1M 001,002,005,010-
or LPCB NE1C/CF1C 108,111,210-
CV1C 212,301-307
8200 <Cassette1>Detect full sensor at stage press position. CF1C sensor was blocked when Cassette 1 Stage was moved H or J CAS1 Cable CS1 or LB1 CF1C/CP1C BS1M 007,301-307,309
down for Note Empty re-check.
8201 <Cassette1>Two or more sensor change was detected CE1C/NF1C sensors were following impossible state during H or J CAS1 CM1 or Cable CS1 CE1C/NF1C 301-307,309
simultaneously.(CE1C/NF1C) mechanical operation.
CE1C sensor : cleared & NF1C sensor : blocked
8202 <Cassette1>Two or more sensor change was detected NE1C/NF1C sensors were following impossible state during H or J CAS1 CM1 or Cable CS1 NE1C/NF1C 301-307,309
simultaneously.(NE1C/NF1C) mechanical operation at BRU.
NE1C sensor : blocked & NF1C sensor : blocked
8203 <Cassette1>Two or more sensor change was detected NE1C/NF1C sensors were following impossible state during H or J CAS1 CM1 or Cable CS1 NE1C/CF1C 301-307,309
simultaneously.(NE1C/NF1C/CF1C) mechanical operation at BNA.
NE1C sensor : blocked & NF1C sensor : blocked
NE1C/CF1C sensors were following impossible state during
mechanical operation at BRU.
NE1C sensor : blocked & CF1C sensor : blocked
8300 <Cassette1>Feed roller lock release is impossible. CO1C sensor was not blocked after waiting the specified time H or J CAS1 CM1 or Cable CS1 or LB1 CO1C BF1M/C1MG 005,101-108,301-
when C1MG solenoid switched on. 307,309
8400 <Cassette1 Transport>After jam with compulsory After jam is generated on cassette1 transport, the solvent wiping H or J CAS1 CM1 or LB 001,002,012
storing. removal is not done. with compulsory storing.
8E00 <Cassette1>Media remains at Transport of Cassette. CR1S/CL1S sensors were blocking even if BF1M motor was J or H CAS1 CM1 or LB CS1 or LB1 CL1S/CR1S BF1M 001,002,101-
rotated in the storing direction. 108,203-206,301-
307,309
91FF <Cassette2>Cassette cannot be used. Because the error occurred before, the cassette cannot be operated. H or J CAS2 CM2 or Cable CS2 or LB1 CT2S/CP2C/ BS2M/BF2M 001,002,005,010-
or LPCB NE2C/CF2C 108,111,210-
CV2C 212,301-307
9200 <Cassette2>Detect full sensor at stage press position. CF2C sensor was blocked when Cassette 2 Stage was moved H or J CAS2 Cable CS2 or LB1 CF2C/CP2C BS2M 007,301-307,309
down for Note Empty re-check.
9201 <Cassette2>Two or more sensor change was detected CE2C/NF2C sensors were following impossible state during H or J CAS2 CM2 or Cable CS2 CE2C/NF2C 301-307,309
simultaneously.(CE2C/NF2C) mechanical operation.
CE2C sensor : cleared & NF2C sensor : blocked
9202 <Cassette2>Two or more sensor change was detected NE2C/NF2C sensors were following impossible state during H or J CAS2 CM2 or Cable CS2 NE2C/NF2C 301-307,309
simultaneously.(NE2C/NF2C) mechanical operation at BRU.
NE2C sensor : blocked & NF2C sensor : blocked
9203 <Cassette2>Two or more sensor change was detected NE2C/NF2C sensors were following impossible state during H or J CAS2 CM2 or Cable CS2 NE2C/CF2C 301-307,309
simultaneously.(NE2C/NF2C/CF2C) mechanical operation at BNA.
NE2C sensor : blocked & NF2C sensor : blocked
NE2C/CF2C sensors were following impossible state during
mechanical operation at BRU.
NE2C sensor : blocked & CF2C sensor : blocked
9300 <Cassette2>Feed roller lock release is impossible CO2C sensor was not blocked after waiting the specified time H or J CAS2 CM2 or Cable CS2 or LB1 CO2C BF2M/C2MG 005,101-108,301-
when C2MG solenoid switched on. 307,309
9400 <Cassette2 Transport>After jam with compulsory After jam is generated on cassette2 transport, the solvent wiping H or J CAS2 CM2 or LB CS2 or LB1 001,002,012
storing. removal is not done. with compulsory storing.
9E00 <Cassette2>Media remains at Transport of Cassette. CR2S/CL2S sensors were blocking even if BF2M motor was J or H CAS2 CM2 or LB CS2 or LB1 CL2S/CR2S BF2M 001,002,101-
rotated in the storing direction. 108,203-206,301-
307,309
9E01 <Cassette2>Unusual notes remained in cassette. After detecting empty by CE2C sensor, when Cassette 2 Stage J or H CAS2 CM2 or LB CS2 or LB1 CP2C/CE2C/ BS2M 001,002,010,302-
moved down on the specified time, media remains were detected CT2S 306,312
by CT2S sensor.
9E80 <Cassette2>Media remains at Transport of Cassette CR2S/CL2S sensors were blocking even if BF2M motor was J or H CAS2 CM2 or LB CS2 or LB1 CL2S/CR2S BF2M 001,002,101-
with compulsory storing. rotated in the storing direction with compulsory storing. 108,203-206,301-
307,309
9F00 <Cassette2>Cannot pick up note from cassette even CR2S/CL2S sensors were not blocked within the specified time J or H CAS2 CM2 or Cable CS2 or LB1 CP2C/CE2C BF2M 002,007,010,012,20
retry 60-times. when picked up notes from Cassette 2. or LB 3-206,312
9F01 <Cassette2>Unusual notes remained The empty was detected when transporting notes from Cassette 2, H or J CAS2 Cable or LB CS2 or LB1 CP2C/CE2C BF2M 001,002,010,302-
but it was not empty when operating the mechanism after that. 306,312
9F02 <Cassette2>Poor rotation of motor Step-out was detected at CS2C sensor during BF2M motor H or J CAS2 CM2 or Cable CS2 or LB1 CS2C BF2M 002,005,007,010,01
rotating. or LB 2,101-108,203-
206,301-307,309
9F03 <Cassette2>The number of not recognized notes in The number of not recognized notes reached the maximum H or S BV CAS2 or Cable 006,010,011
Cassette2 was exceeded. number while notes were transported from Cassette 2.
A1FF <Cassette3>Cassette cannot be used. Because the error occurred before, the cassette cannot be operated. H or J CAS3 CM3 or Cable CS3 or LB3 CT3S/CP3C/ BS3M/BF3M 001,002,005,010-
or LPCB NE3C/CF3C 108,111,210-
CV3C 212,301-307
A200 <Cassette3>Detect full sensor at stage press position. CF3C sensor was blocked when Cassette 3 Stage was moved H or J CAS3 Cable CS3 or LB3 CF3C/CP3C BS3M 007,301-307,309
down for Note Empty re-check.
A201 <Cassette3>Two or more sensor change was detected CE3C/NF3C sensors were following impossible state during H or J CAS3 CM3 or Cable CS3 CE3C/NF3C 301-307,309
simultaneously.(CE3C/NF3C) mechanical operation.
CE3C sensor : cleared & NF3C sensor : blocked
A202 <Cassette3>Two or more sensor change was detected NE3C/NF3C sensors were following impossible state during H or J CAS3 CM3 or Cable CS3 NE3C/NF3C 301-307,309
simultaneously.(NE3C/NF3C) mechanical operation at BRU.
NE3C sensor : blocked & NF3C sensor : blocked
B1FF <Cassette4>Cassette cannot be used. Because the error occurred before, the cassette cannot be operated. H or J CAS4 CM4 or Cable CS4 or LB4 CT4S/CP4C/ BS4M/BF4M 001,002,005,010-
or LPCB NE4C/CF4C 108,111,210-
CV4C 212,301-307
B200 <Cassette4>Detect full sensor at stage press position. CF4C sensor was blocked when Cassette 4 Stage was moved H or J CAS4 Cable CS4 or LB4 CF4C/CP4C BS4M 007,301-307,309
down for Note Empty re-check.
B201 <Cassette4>Two or more sensor change was detected CE4C/NF4C sensors were following impossible state during H or J CAS4 CM4 or Cable CS4 CE4C/NF4C 301-307,309
simultaneously.(CE4C/NF4C) mechanical operation.
CE4C sensor : cleared & NF4C sensor : blocked
B202 <Cassette4>Two or more sensor change was detected NE4C/NF4C sensors were following impossible state during H or J CAS4 CM4 or Cable CS4 NE4C/NF4C 301-307,309
simultaneously.(NE4C/NF4C) mechanical operation at BRU.
NE4C sensor : blocked & NF4C sensor : blocked
B203 <Cassette4>Two or more sensor change was detected NE4C/NF4C sensors were following impossible state during H or J CAS4 CM4 or Cable CS4 NE4C/CF4C 301-307,309
simultaneously.(NE4C/NF4C/CF4C) mechanical operation at BNA.
NE4C sensor : blocked & NF4C sensor : blocked
NE4C/CF4C sensors were following impossible state during
mechanical operation at BRU.
NE4C sensor : blocked & CF4C sensor : blocked
B300 <Cassette4>Feed roller lock release is impossible CO4C sensor was not blocked after waiting the specified time H or J CAS4 CM4 or Cable CS4 or LB4 CO4C BF4M/C4MG 005,101-108,301-
when C4MG solenoid switched on. 307,309
B400 <Cassette4 Transport>After jam with compulsory After jam is generated on cassette4 transport, the solvent wiping H or J CAS4 CM4 or LB CS4 or LB4 001,002,012
storing. removal is not done. with compulsory storing.
BE00 <Cassette4>Media remains at Transport of Cassette. CR4S/CL4S sensors were blocking even if BF4M motor was J or H CAS4 CM4 or LB CS4 or LB4 CL4S/CR4S BF4M 001,002,101-
rotated in the storing direction. 108,203-206,301-
307,309
BE01 <Cassette4>Unusual notes remained in cassette. After detecting empty by CE4C sensor, when Cassette 4 Stage J or H CAS4 CM4 or LB CS4 or LB4 CP4C/CE4C/ BS4M 001,002,010,302-
moved down on the specified time, media remains were detected CT4S 306,312
by CT4S sensor.
F401 <Over-current>Over-current detection at Upper Base Overcurrent detected. This was caused because FL5VUB bit had H or C UPCB UB1,UB2 UULC,UCFC 302,307
5V line (FL5VUB) been set. ,URFC,UFFC
,UGAS,URH
S,UFHS,UG
DS,URLC,U
LPC,UECS,U
EFS,UERS,U
GLC
F402 <Over-current>Over-current detection at Escrow 5V Overcurrent detected. This was caused because FL5VES bit had H or C UPCB SE2 EECS,ETSS, 302,307
line (FL5VES) been set. EELS,EERS,
EDLS,EDRS,
ERLS,ERRS
F403 <Over-current>Over-current detection at Separator 5V Overcurrent detected. This was caused because FL5VSE bit had H or C UPCB SE1, PS1S,PS2S,P 302,307
line (FL5VSE) been set. S3S,PS4S,PT
CS,PASS,PD
SS,SDIS,SD
OS,SSLS,SS
RS,SSOS
F404 <Over-current>Over-current detection (FL5VRV) Overcurrent detected. This was caused because FL5VRV bit had H or C UPCB RV2S, PHPC,PLPC, 302,307
been set. RV2PH PDAC,ETRS
F405 <Over-current>Over-current detection at Separator 5V Overcurrent detected. This was caused because FL5VSE4 bit had H or C SPCB SE5,SE7, SPUC,SPPC, SEDM, 302,307
line (FL5VSE4) been set. SPWR SPBC,SSUC, SEPM,
SSLC,SSEC, SESM
SFIC,SFOC,S
PCC,SFPC,S
BLC,SCDC,S
HDC
F406 <Over-current>Over-current detection at Escrow 5V Overcurrent detected. This was caused because FL5VES4 bit had H or C SPCB ES1,ES3 ERUC,ERRC EESM, 302,307
line (FL5VES4) been set. ,ERLC,EVPC ERSM
,EELC,EERC
,EEUC,ECR
C,ECPC,EC
CC,ECHC
F408 <Over-current>Over-current detection at Separator 24V Overcurrent detected. This was caused because FL24VSE bit had H or C UPCB SE4,SPWR, SEFM, 302,307
line (FL24VSE) been set. (or SPCB) SE6,SPWR ESCM,
SEPM,
SESM,
SEDM,
SRMG
F411 <Over-current>Over-current detection at Shutter 5V Overcurrent detected. This was caused because FL5VSH bit had H or C LPCB SHT2 SHOC,SHCC 302,307
line (FL5VSH) been set.
F412 <Over-current>Over-current detection (FL5VEX) Overcurrent detected. This was caused because FL5VEX bit had H or C LPCB (EXT) 302,307
been set.
F413 <Over-current>Over-current detection (FL5VRV) Overcurrent detected. This was caused because FL5VRV bit had H or C LPCB (RV1PH) 302,307
been set. (RSVS)
F414 <Over-current>Over-current detection at Cassette Overcurrent detected. This was caused because FL5VCS1 bit had H or C LPCB CS1 302,307
Position 1 5V line (FL5VCS1) been set.
F415 <Over-current>Over-current detection at Cassette Overcurrent detected. This was caused because FL5VCS2 bit had H or C LPCB CS2 302,307
Position 2 5V line (FL5VCS2) been set.
F416 <Over-current>Over-current detection at Cassette Overcurrent detected. This was caused because FL5VCS3 bit had H or C LPCB CS3 302,307
Position 3 5V line (FL5VCS3) been set.
F417 <Over-current>Over-current detection at Cassette Overcurrent detected. This was caused because FL5VCS4 bit had H or C LPCB CS4 302,307
Position 4 5V line (FL5VCS4) been set.
F418 <Over-current>Over-current detection at Lower Base Overcurrent detected. This was caused because FL24VLB1 bit had H or C LPCB LB1 BS1M, 302,307
24V line (FL24VLB1) been set. BF1M,
BS2M,
BF2M
F419 <Over-current>Over-current detection at Lower Base Overcurrent detected. This was caused because FL24VLB2 bit had H or C LPCB LB3,LB4 BS3M, 302,307
24V line (FL24VLB2) been set. BF3M,
BS4M,
BF4M
F41A <Over-current>Over-current detection at Lower Overcurrent detected. This was caused because FL24VLT bit had H or C LPCB LT1 L1MG, 302,307
Transport 24V line (FL24VLT) been set. L2MG,
L3MG,
L4MG
F625 <Pre-Acceptor>Notes remains at PS1S sensor. PS1S sensor was blocked during MR command. J or C PAC remaining UPCB SE1 001,002,010,103-
note checking 108,116,201-206,
214-220,301-307
F626 <Pre-Acceptor>Notes remains at PS2S sensor. PS2S sensor was blocked during MR command. J or C PAC remaining UPCB SE1 001,002,010,103-
note checking 108,116,201-206,
214-220,301-307
F627 <Pre-Acceptor>Notes remains at PS3S sensor. PS3S sensor was blocked during MR command. J or C PAC remaining UPCB SE1 001,002,010,103-
note checking 108,116,201-206,
214-220,301-307
F628 <Pre-Acceptor>Notes remains at PS4S sensor. PS4S sensor was blocked during MR command. J or C PAC remaining UPCB SE1 001,002,010,103-
note checking 108,116,201-206,
214-220,301-307
F629 <Bunch Transport>Notes remains at Bunch transport. EERS/EELS sensors were blocked. J or C ESC remaining PAC or SEP SE1 001,002,010,103-
Media remaining data of Top transport memorized by software had note checking remaining note 108,116,201-206,
been set when a command or note transport started. checking 214-221,301-307
or UPCB
F631 <Separator Transport>Notes stay at SSRS/SSLS/SSOS During jam clear processing, SSRS/SSLS/SSOS sensors did not J or C SEP remaining UPCB SE1 001,002,010,012,10
sensor become clear within the specified time. note checking 3-108,203-206,301-
307
F637 <Escrow Transport>Notes stay at EDRS/EDLS sensor During jam clear processing, EDRS/EDLS sensors did not become J or C ESC remaining UT remaining SE2 001,002,010,103-
clear within the specified time. note checking note checking 108,201-208,301-
or UPCB 307
F638 <Escrow Transport>Notes stay at ERRS/ERLS sensor During jam clear processing, ERRS/ERLS sensors did not become J or C ESC remaining UT remaining SE2 001,002,010,103-
clear within the specified time. note checking note checking 108,201-208,301-
or UPCB 307
F639 <Reject Transport>Notes stay at UGDS sensor During jam clear processing, UGDS sensor did not become clear J or C UT remaining UPCB UB1 001,002,010,103-
within the specified time. note checking 108,201-208,301-
307
F63A <Reject Transport>Notes stay at UEFS sensor During jam clear processing, UEFS sensor did not become clear J or C UT remaining RJ Bin UB2 001,002,010,103-
within the specified time. note checking remaining note 108,201-208,301-
checking 307
F63B <Reject Transport>Notes stay at UERS sensor During jam clear processing, UERS sensor did not become clear J or C UT remaining RJ Bin UB2 001,002,010,103-
within the specified time. note checking remaining note 108,201-208,301-
checking 307
F63C <Reject Transport>Notes stay at UECS sensor During jam clear processing, UECS sensor did not become clear J or C UT remaining RJ Bin UB2 001,002,010,103-
within the specified time. note checking remaining note 108,201-208,301-
checking 307
F63D <Cassette1 Transport>Notes stay at CR1S/CL1S sensor During jam clear processing, CR1S/CL1S sensors did not become J or C CAS1 remaining LT remaining CS1 001,002,010,103-
clear within the specified time. note checking note checking UPCN 108,201-208,301-
or LPCB 307
F63E <CAssette2 Transport>Notes stay at CR2S/CL2S During jam clear processing, CR2S/CL2S sensors did not become J or C CAS2 remaining LT remaining CS2 001,002,010,103-
sensor clear within the specified time. note checking note checking UPCN 108,201-208,301-
or LPCB 307
F63F <Cassette3 Transport>Notes stay at CR3S/CL3S sensor During jam clear processing, CR3S/CL3S sensors did not become J or C CAS3 remaining LT remaining CS3 001,002,010,103-
clear within the specified time. note checking note checking UPCN 108,201-208,301-
or LPCB 307
F64B <Transport before BV>Notes stay at LFHS sensor During jam clear processing, LFHS sensor did not become clear J or C LT remaining LPCB LT1 001,002,009,010,10
within the specified time. note checking 3-108,201-208,301-
307
F64C <BV>Notes stay in BV During jam clear processing, BVIN sensor did not become clear J or C BV remaining UPCB BV LAN 001,002,010,103-
within the specified time. note checking 108,201-
206,224,301-307
F64D <BV>Notes stay in BV During jam clear processing, BVOUT sensor did not become clear J or C BV remaining UPCB BV LAN 001,002,010,103-
within the specified time. note checking 108,201-
206,224,301-307
F64E <Cassette1 Transport>Notes stay at CR1S/CL1S sensor During jam clear processing, CR1S/CL1S sensors did not become J or C CAS1 remaining LT remaining CS1 001,002,010,103-
with compulsory storing clear within the specified time with compulsory storing. note checking note checking 108,201-208,301-
or LPCB 307
F64F <CAssette2 Transport>Notes stay at CR2S/CL2S During jam clear processing, CR2S/CL2S sensors did not become J or C CAS2 remaining LT remaining CS2 001,002,010,103-
sensor with compulsory storing clear within the specified time with compulsory storing. note checking note checking 108,201-208,301-
or LPCB 307
F650 <Cassette3 Transport>Notes stay at CR3S/CL3S sensor During jam clear processing, CR3S/CL3S sensors did not become J or C CAS3 remaining LT remaining CS3 001,002,010,103-
with compulsory storing clear within the specified time with compulsory storing. note checking note checking 108,201-208,301-
or LPCB 307
F651 <CAssette4 Transport>Notes stay at CR4S/CL4S During jam clear processing, CR4S/CL4S sensors did not become J or C CAS4 remaining LT remaining CS4 001,002,010,103-
sensor with compulsory storing clear within the specified time with compulsory storing. note checking note checking 108,201-208,301-
or LPCB 307
F7** Illegal Sensor Error
F700 <Separator Transport>Illegal sensor detect Illegal change of SSRS/SSLS/SSOS sensors detected during H SEP SSRS/SSLS/ 001,002,301-
SSRS/SSLS/SSOS command processing. SSOS 307,311
F701 <Transport after BV>Illegal sensor detect UGAS Illegal change of UGAS sensor detected during command H UT UGAS 001,002,301-
processing. 307,311
F702 <Reject Transport>Illegal sensor detect UGDS Illegal change of UGDS sensor detected during command H UT UGDS 001,002,301-
processing. 307,311
F703 <Escrow Transport>Illegal sensor detect EDRS/EDLS Illegal change of EDRS/EDLS sensors detected during command H ESC EDRS/EDLS 001,002,301-
processing. 307,311
F704 <Escrow Transport>Illegal sensor detect ERRS/ERLS Illegal change of ERRS/ERLS sensors detected during command H ESC ERRS/ERLS 001,002,301-
processing. 307,311
F705 <Reject Transport>Illegal sensor detect UECS Illegal change of UECS sensor detected during command H UT UECS 001,002,301-
processing. 307,311
F706 <Reject Transport>Illegal sensor detect UERS Illegal change of UERS sensor detected during command H UT UERS 001,002,301-
processing. 307,311
F709 <Transport before BV>Illegal sensor detect UFHS Illegal change of UFHS sensor detected during command H UT UFHS 001,002,301-
processing. 307,311
F70A <Cassette3 Transport>Illegal sensor detect LT3S Illegal change of LT3S sensor detected during command H LT LT3S 001,002,301-
processing. 307,311
F70B <Cassette1 Transport>Illegal sensor detect CR1S/CL1S Illegal change of CR1S/CL1S sensors detected during command H CAS1 CR1S/CL1S 001,002,301-
processing. 307,311
F70C <Cassette2 Transport>Illegal sensor detect CR2S/CL2S Illegal change of CR2S/CL2S sensors detected during command H CAS2 CR2S/CL2S 001,002,301-
processing. 307,311
F70D <Cassette3 Transport>Illegal sensor detect CR3S/CL3S Illegal change of CR3S/CL3S sensors detected during command H CAS3 CR3S/CL3S 001,002,301-
processing. 307,311
F70E <Cassette4 Transport>Illegal sensor detect CR4S/CL4S Illegal change of CR4S/CL4S sensors detected during command H CAS4 CR4S/CL4S 001,002,301-
processing. 307,311
F70F <Transport before BV>Illegal sensor detect LFHS Illegal change of LFHS sensor detected during command H LT LFHS 001,002,301-
processing. 307,311
F710 <Upper Unit>Upper unit come off during processing Illegal change of UULC sensor detected during command H UT UULC 001,002,301-
processing. 307,311
F711 <Lower Unit>Lower unit come off during processing Illegal change of ULPC sensor detected during command H UT LT or Cradle ULPC 001,002,301-
processing. 307,311
F712 <Reject bin>Reject bin come off during processing Illegal change of URLC sensor detected during command H UT URLC 001,002,301-
processing. 307,311
F713 <Lower Transport>Lower transport come off during Illegal change of BLLC sensor detected during command H LT BLLC 001,002,301-
processing processing. 307,311
F714 <BV>Illegal sensor detect in BV Illegal change of BVIN sensor detected during command H BV BVIN 001,002,301-
processing. 307,311
F715 <BV>Illegal sensor detect in BV Illegal change of BVOUT sensor detected during command H BV BVOUT 001,002,301-
processing. 307,311
F716 <Shutter>Illegal sensor detect SHCC Illegal change of SHCC sensor detected during command H SHT SHCC 001,002,301-
processing. 307,311
F717 <Transport before BV>Transport before BV come off Illegal change of SBLC sensor detected during command H SEP SBLC 001,002,301-
during processing processing. 307,311
F718 <Transport under Reject bin>Transport under Reject Illegal change of UGLC sensor detected during command H UT UGLC 001,002,301-
bin come off during processing processing. 307,311
F719 <Top Transport>Top transport come off during Illegal change of ETLC sensor detected during command H ESC ETLC 001,002,301-
processing processing. 307,311
FF05 <Pre-Acceptor>Over max light PASS sensor At the time of sensor level adjustment, PASS sensor was not H Sensor cleaning PAC PASS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF06 <Pre-Acceptor>Over max light PDSS sensor At the time of sensor level adjustment, PDSS sensor was not H Sensor cleaning PAC PDSS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF07 <Separator Transport>Over max light SDIS sensor At the time of sensor level adjustment, SDIS sensor was not H Sensor cleaning SEP SDIS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF08 <Separator Transport>Over max light SDOS sensor At the time of sensor level adjustment, SDOS sensor was not H Sensor cleaning SEP SDOS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF09 <Separator Transport>Over max light SSLS sensor At the time of sensor level adjustment, SSLS sensor was not H Sensor cleaning SEP SSLS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF0A <Separator Transport>Over max light SSRS sensor At the time of sensor level adjustment, SSRS sensor was not H Sensor cleaning SEP SSRS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF0B <Separator Transport>Over max light SSOS sensor At the time of sensor level adjustment, SSOS sensor was not H Sensor cleaning SEP SSOS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF0C <Escrow>Over max light EECS sensor At the time of sensor level adjustment, EECS sensor was not H Sensor cleaning ESC EECS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF0D <Escrow>Over max light ETLS sensor At the time of sensor level adjustment, ETLS sensor was not H Sensor cleaning ESC ETLS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF0E <Bunch Transport>Over max light EELS sensor At the time of sensor level adjustment, EELS sensor was not H Sensor cleaning ESC EELS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF10 <Escrow Transport>Over max light EDLS sensor At the time of sensor level adjustment, EDLS sensor was not H Sensor cleaning ESC EDLS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF11 <Escrow Transport>Over max light EDRS sensor At the time of sensor level adjustment, EDRS sensor was not H Sensor cleaning ESC EDRS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF12 <Escrow Transport>Over max light ERLS sensor At the time of sensor level adjustment, ERLS sensor was not H Sensor cleaning ESC ERLS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF13 <Escrow Transport>Over max light ERRS sensor At the time of sensor level adjustment, ERRS sensor was not H Sensor cleaning ESC ERRS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF14 <Transport after BV>Over max light UGAS sensor At the time of sensor level adjustment, UGAS sensor was not H Sensor cleaning UT UGAS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF15 <Cassettes Transport>Over max light URHS sensor At the time of sensor level adjustment, URHS sensor was not H Sensor cleaning UT URHS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF16 <Transport before BV>Over max light UFHS sensor At the time of sensor level adjustment, UFHS sensor was not H Sensor cleaning UT UFHS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF17 <Reject Transport>Over max light UGDS sensor At the time of sensor level adjustment, UGDS sensor was not H Sensor cleaning UT UGDS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF18 <Reject Transport>Over max light UECS sensor At the time of sensor level adjustment, UECS sensor was not H Sensor cleaning UT UECS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF19 <Reject Transport>Over max light UEFS sensor At the time of sensor level adjustment, UEFS sensor was not H Sensor cleaning UT UEFS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF1B <Cassette3 Transport>Over max light LT3S sensor At the time of sensor level adjustment, LT3S sensor was not H Sensor cleaning LT LT3S 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF1C <Cassette4 Transport>Over max light LFHS sensor At the time of sensor level adjustment, LFHS sensor was not H Sensor cleaning LT LFHS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
FF1D <Cassette1>Over max light CL1S sensor At the time of sensor level adjustment, CL1S sensor was not H Sensor cleaning CAS1 CL1S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF1E <Cassette1>Over max light CR1S sensor At the time of sensor level adjustment, CR1S sensor was not H Sensor cleaning CAS1 CR1S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF1F <Cassette2>Over max light CL2S sensor At the time of sensor level adjustment, CL2S sensor was not H Sensor cleaning CAS2 CL2S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF20 <Cassette2>Over max light CR2S sensor At the time of sensor level adjustment, CR2S sensor was not H Sensor cleaning CAS2 CR2S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF21 <Cassette3>Over max light CL3S sensor At the time of sensor level adjustment, CL3S sensor was not H Sensor cleaning CAS3 CL3S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF22 <Cassette3>Over max light CR3S sensor At the time of sensor level adjustment, CR3S sensor was not H Sensor cleaning CAS3 CR3S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF23 <Cassette4>Over max light CL4S sensor At the time of sensor level adjustment, CL4S sensor was not H Sensor cleaning CAS4 CL4S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF24 <Cassette4>Over max light CR4S sensor At the time of sensor level adjustment, CR4S sensor was not H Sensor cleaning CAS4 CR4S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF26 <Cassette2>Over max light CT2S sensor At the time of sensor level adjustment, CT2S sensor was not H Sensor cleaning CAS2 CT2S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF27 <Cassette3>Over max light CT3S sensor At the time of sensor level adjustment, CT3S sensor was not H Sensor cleaning CAS3 CT3S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF28 <Cassette4>Over max light CT4S sensor At the time of sensor level adjustment, CT4S sensor was not H Sensor cleaning CAS4 CT4S 301-304,307,309
cleared even if maximum level. Or a margin was not able to be
gotten.
FF29 <Escrow>Over max light ETRS sensor At the time of sensor level adjustment, ETRS sensor was not H or C Sensor cleaning ESC SE2 ETRS 301-304,307
cleared even if maximum level. Or a margin was not able to be
gotten.
How to check whether fixed : Execute Reset (Mechanical reset & Jam clear) and Deposit / Dispense operation using note.
General error
001 Note remain Is any note or a piece of note remaining on the transport rout? Remove remaining notes or a piece of note if any.
(Visual check)
002 Foreign object remain Is any dust, clips, coins or a piece of paper remaining on the transport rout? Remove remaining foreign object if any.
(Visual check)
003 Improper module setting Check if GBRU/GBNA is properly locked on Cradle having correct clearance When mounting, push the module until it is properly locked.
by moving it manually. If the module does not move smoothly, adjust the lock position to create
clearance of 0.3mm - 0.8mm.
004 Jam clearance areas not fully locked Are jam clearance areas completely closed and fully locked? Close all jam clearance areas until they are locked.
005 Improper cassette setting Is CASSETTE/RJ-BIN properly set? Insert a Cassette into a proper position.
When mounting, push RJ-bin until it is locked.
006 Unit information setting error Are the unit information settings about denomination, maximum number of Check denomination settings and if magnet positions or note width guide
notes or etc. appropriate? positions do not correspond to the settings, correct them.
007 Inappropriate note amount loaded Is the number of notes loaded in a cassette appropriate? (Cassette Full? Load appropriate number of notes.
Cassette Empty?)
Is note denomination correct?
008 Power supply and connection failure Are the power supply and controller connected properly? If they are not, reconnect them properly.
009 Module set unbalanced Are upper and lower modules mounted with a tilt or misalignment (between Adjust the module position and refasten a fixing screw for the slide rail.
upper and lower, left and right, front and back)? Are all the fixing parts
fastened? (Visual check)
010 Bad note quality Check condition of notes to be loaded. Check if notes are seriously damaged or have any adhesion of dirt on the
surface.
011 BV unit error - Reset
012 Pick-up mechanism adjustment failure Check the way how notes are rejected. Frequent errors caused by abnormal Separator: In the case of frequent errors due to abnormal note distance,
note distance, abnormal note length, double feed, skew? double feed and note length, turn the dial by 45 degrees counterclockwise.
Separator: In the case of frequent skew errors, turn the dial by 45 degrees
clockwise.
If the measures above show no improvement or deteriorate the problem, or
cause another problem, it is recommended to replace the modules.
Cassette: Replace cassettes.
013 Software problem - Power off & on
014 Firmware not downloading - Download the firmware.
015 RAS operation miss - -
016 Authentication operation miss - Authenticate communication
017 Authentication level not match - Execute RAS-FA using switch
101 Motor/Solenoid failure or damage Check if motor is rotating and solenoid is activating by a mechanical reset. Replace motors/solenoids.
Check for abnormal sound.
102 Motor/solenoid not fixed securely Is motor/solenoid mounted firmly? Is there any damage and deformation to Fix motor/solenoid properly.
the fixing brackets? (Visual check)
103 Pulley/Gear improper rotation Are pulley/gear properly fixed with a shaft and sliding smoothly without Fix the fixing part of pulley/gear properly again.
interfering surrounding parts? When pulley/gear do not move smoothly, disassemble them and then clean
(Check visually and manually) and remove foreign objects if any. When pulley/gear interfere with
surrounding parts, check for deformation.
104 Belt come off/torn off Visual check. Place a belt to a proper position. If belt still comes off, adjust belt tension.
Replace belts if torn or damaged.
105 Belt tension failure Check belt tension. Readjust belt tension.
106 Inappropriate Gear backlash Check the amount of gear backlash using a manual handle. If gears have a same diameter, try changing phase of gear engagement.
Lubricate gears.
107 Bearing rotation not smooth Check if bearing is deformed, damaged, or catching foreign objects, or if Remove foreign objects if any.
shaft is worn using a manual knob handle.
108 Thrust clearance of shaft insufficient Confirm that thrust clearance of shaft is not 0mm by hand. Remove foreign objects if any. If there is no foreign object, check for parts
deformation.
109 Link mechanism operation failure Is link/stud/hub deformed or catching foreign objects? (Check visually and Remove any foreign objects or lubricate. If the failure still arises, check for
manually) parts deformation.
Is link/stud/hub well lubricated? (Visual check)
110 Carrier drive cam phase missynchronous Check the engagement of cam by moving Carrier back and forth using a To adjust cam phase, align the matching marks on pulleys with those on the
manual handle. frame and then reattach Carrier drive belt.
111 Stage/Pusher belt connection part disengaged Is belt connection part removed from Stage/Pusher? (Visual check) Connect the belt connection part to Stage/Pusher again.
112 Fork operation failure Is Separator fork deformed or damaged? (Visual check) Remove any foreign object or lubricate. If the failure still arises, check for
Check if Solenoid moves smoothly by pushing it by hand. parts deformation.
113 Escrow alignment lever operation failure Is ESC alignment lever deformed or damaged? (Visual check) Remove any foreign object or lubricate. If thrust clearance is needed, bend
Is there appropriate thrust clearance? the bracket slightly as an emergency measure. If the failure still arises, parts
Are notes stored in a proper position in ESC? may have been deformed or damaged to the extent that it is hard to repair.
114 Reservoir alignment lever operation failure Is RSV alignment lever deformed or damaged? (Visual check) Remove any foreign object or lubricate. If thrust clearance is needed, bend
Is there appropriate thrust play? the bracket slightly as an emergency measure. If the failure still arises, parts
Does RSV alignment lever move properly associated with RSV stage may have been deformed or damaged to the extent that it is hard to repair.
movement?
115 RSV storing lever operation failure Is RSV storing lever deformed or damaged? (Visual check) Remove any foreign object or lubricate. If the failure still arises, check for
Does RSV storing lever move properly associated with RSV stage movement? parts deformation.
116 Shutter open/close operation failure Is shutter deformed or damaged? (Visual check) Remove any foreign object or lubricate. If the failure still arises, check for
Check if shutter moves smoothly by opening and closing it by hand. parts deformation.
117
201 Flat belt come off/torn/damaged Visual check Replace flat belts.
202 Flat belt slip Does flat belt slip against flat pulley? (Check manually) Clean flat belt/flat pulley with alcohol. If flat pulley does not rotate smoothly,
disassemble it and clean its hole and the shaft.
203 Transport roller disengaged/worn/damaged Visual check If transport roller is out of position, return it in place.
204 Transport roller slip Does transport roller maintain sufficient transport force? Put a note between Clean roller surface with alcohol if transport force is significantly reduced.
transport rollers and pull it by hand to check transport force.
205 Transport guide deformation, Is transport guide deformed or damaged? Properly mounted? (Visual check) In the case of improper installation, re-mount transport guide properly.
mounting failure
206 Scratch, burr, adhesion of foreign object, protrusion on Is transport surface smooth? Remove any foreign objects adhered on transport surface. Try to plane away
transport surface any scratches and burrs. Smooth surface required.
207 Gate not smooth Confirm that thrust clearance of gate joint is not 0mm by moving it manually. Loosen a gate joint screw so as to generate thrust clearance of axis and fix it
Does gate interfere with surrounding parts? (Visual check) again.
208 Gate angle failure Is point of gate_fin protruding to transport surface? (Visual check) Loosen a gate joint screw and adjust gate position using turning clearance,
and then fix the screw again.
Or adjust the guide that covers the point of gate_fin and fix it again.
209 Rubber fin roller broken, disengaged Is any fin missing? Does rubber fin roller rotate stably? If some fins are lost, replace the module.
Note) The rubber fin roller of cassette is intermittent originally shape.
210 Carrier and Stage/Pusher tilted Are Carrier and Stage/Pusher assembled horizontally? (Visual check)y Level Stage/Pusher by adjusting drive belt phase.
211 Carrier and Stage/Pusher deformed or damaged Visual check Replace them.
212 Carrier and Stage/Pusher stopping position error Perform a mechanical reset to see if wrong positioning of Carrier and In the case of sensor disengagement, fix it.
Stage/Pusher interfere with Carrier movement and causes note collision.
213 Carrier interference Check if Carrier and Reservoir stage rubber interfere each other and also if If stage positioning sensor is disengaged, fix it.
Carrier is deformed or damaged visually.
214 Pre-Acceptor clamp tilted Is clamp flush against bottom transport belt? (check 4 points-left, right, front Readjust clamp using an adjustment screw if it is tilted.
and rear)
215 Pre-Acceptor clamp transport belt tension failure Is transport belt tension for clamp appropriate? Readjust belt tension.
216 Pre-Acceptor clamp up/down movement failure Check if clamp can move up to a required height, stay there and move down Readjust clamp tilt. In the case of sensor disengagement, fix it. Readjust
until it reaches bottom transport belt by performing a mechanical reset. surrounding drive belt tension/transport belt tension if necessary.
(Visual check)
217 Pre-Acceptor hook operation failure Check if hook can stand vertically and also lie down horizontally in RAS Adjust mounting position of hook drive solenoid.
mode.
Check if a standing hook is not easily fallen down when pushed by hand.
218 Pre-Acceptor tray operation failure Is tray deformed or damaged, or interfering with bottom surface? (Visual Replace trays if deformed or damaged.
check) Adjust drive belt tension.
Is there any foreign objects under tray? (Visual check) Remove foreign objects if any.
219 Pre-Acceptor and shutter engagement failure Is Pre-Acceptor transport surface connected to shutter with no gap and Readjust facing with Fascia.
without being pushed too much by Fascia. (Visual check)
220 A-stopper operation failure Check if A-stopper can stand vertically and also lie down horizontally in Readjust a position where A-stopper solenoid is fixed.
RAS mode, and check if a standing hook is not easily fallen down when
pushed by hand.
221 D stopper operation failure Check if D-stopper can stand vertically and also lie down horizontally in Readjust a position where D-stopper solenoid is fixed.
RAS mode.
222 Deskew roller operation failure Check if skew correction rollers and pinch rollers are not worn and can rotate Replace rollers if worn. Remove any foreign objects and clean.
smoothly.
223 Free gate operation failure Check if free gate moves smoothly and is not deformed/damaged. (Check Remove any foreign objects and clean.
manually and visually.)
224 BV does not face to transport guide Check if BV is mounted on Upper base without gap by visual check and if Adjust and fix BV/transport guide again.
transport guide is deformed/damaged.
225 Leaf spring failure at the entrance of reject bin Is the leaf spring located at the entrance of Reject box/Reject bin deformed? Replace leaf springs.
(Visual check)
226 Discharge brush failure Check if discharge brush is attached and is not worn out by visual check. Replace discharge brushes.
Check the continuity using a tester.
227 Reject Full detection lever operation failure Check if Note Full detection lever inside Reject bin moves smoothly by hand. Remove any foreign objects, clean and lubricate.
228
229
230
301 Connector not fully attached/Wrong connection Visual check Connect properly.
302 Breaking of cable/Short-circuit Visual check. Replace cables.
Check the continuity using a tester.
303 Sensor/Prism removal, optical axis misalignment Are sensor/prism/fixing parts removed or deformed? (Visual check) Fix sensor/prism.
304 Sensor/Prism dirty, scratched Check light receiving/emitting face of Sensor/Prism visually. Cleaning required. Or replace them if remarkable scratches found.
305 Sensor block plate deformed Visual check Repair deformed parts or replace.
306 Sensor damaged Check sensor output in RAS mode. Replace sensors.
Replace sensors and then check the output in RAS mode.
307 PCB or ROM failure Replace PCBs and then check the operation. Replace PCBs.
308 Overload detection failure Check cable connection and scratches visually. Refer to 301 - 307.
Check if sensor is damaged or removed.
309 Floating connector failure Is floating connector damaged/deformed or catching any foreign objects? Remove any foreign objects and clean.
(Visual check)
310 Fuse blown Visual check Replace fuses.
311 External noise Check ground connection. Fix earth connection, change cable layout.
312 Lever detection plate operation failure (Note Empty Check if detection plate fulcrum moves smoothly by hand. Repair deformed parts or replace.
check or others) Is lever detection plate deformed/damaged? (Visual check)
313 USB cable pulled out Visual check Connect properly.
314 USB cable damaged Visual check Replace the cable.
315 LAN cable between BRU and BV pulled out Visual check Connect properly.
316 LAN cable between BRU and BV damaged Visual check Replace the cable.
317 Power cable for BV pulled out Visual check Connect properly.
318 Power cable for BV damaged Visual check Replace the cable.