Master Plumber Practice Test MPLE Reviewer
Master Plumber Practice Test MPLE Reviewer
(https://www.tests.com/)
2024 EDITION
Master Plumber Practice Test
This Free Master Plumber Practice Test will give you an idea of the types of questions and sections
on your actual exam.
1. As a master plumber you will be allowed to apply for plumbing permits. Which of the following
data will you be required to provide on a plumbing permit application?
a. Your full name and address (/master-plumber-practice-
exam)
b. A full description of the plumbing work you propose to do
c. The zoned use of the property where the plumbing will be installed Master Plumbing Test Guide
d. All of the above Plumbing State Guides
2. For the issuance of a plumbing permit, which of the following is normally required?
a. Design plans
b. Complete specifications
c. A description of the use of the building
d. All of the above
e. Both a and b only
3. If alterations are made in an existing plumbing system, the work is required to bring the entire
existing plumbing system up to current code requirements.
True
False
4. Your job requires you to schedule maintenance on a large commercial building for one of your
customers. What is the required frequency for the inspection of backflow preventers?
a. Once a month
b. Once every 3 months
c. Once every 4 months
d. Once every year
Fixtures
7. What is the maximum distance that employees can be required to walk in order to reach a
restroom?
a. 150 feet
b. 300 feet
c. 400 feet
d. 500 feet
https://www.tests.com/practice/Master-Plumber-Certification 1/5
5/20/24, 2:15 PM Master Plumber Practice Test
8. What is the minimum allowable height for a handicap toilet? Plumbing Practice Test
Sample Questions
a. 14 inches
b. 16 inches
c. 18 inches
d. 22 inches
9. Accessible lavatories are required to be installed so that the distance from a finished floor to the
top of a lavatory is no more than ______ inches.
a. 18
b. 24
c. 35
d. 42
10. Discharge tubing connected to a relief valve does not require traps for which of the following?
a. A water heaters
b. A boiler
c. An expansion tank that serves a boiler
d. All of the above
11. You are in charge of a rough-in installation. The specifications given to you indicate the need for
an indirect waste receptor. Upon further reflection, you notice a code violation in the
specifications. The specs call for a fixture that is not normally allowed in a room with an indirect
waster receptor. You are going to investigate this with the person who created the specifications.
What type of fixture is it that you are questioning?
a. Floor drain
b. Food preparation equipment
c. Toilet
d. Kitchen sink
12. What is the maximum allowable water temperature that can be used with a commercial
dishwashing machine?
a. 115 degrees F
b. 120 degrees F
c. 140 degrees F
d. None of the above
13. When multiple fixtures discharge into a wet vent they must do so upstream of the wet vent.
True
False
14. What type of vent is only allowed to convey air and sewer gas?
a. A wet vent
b. A stack vent
c. A vent stack
d. An island vent
15. What is the minimum allowable diameter for a vent that will serve a sump for a sewer pump that
has a discharge capacity of 500 gpm?
a. 2 inch
b. 3 inch
c. 4 inch
d. 6 inch
16. Drain pipes that are not building drains or horizontal branches that are installed in second-story
framing are _________.
a. required to have accessible cleanouts
b. required to have no less than one cleanout at the end of the run of piping
c. not required to be equipped with cleanouts
d. not required to be equipped with cleanouts when the building drain is four inches, or larger, in
diameter.
17. What type of drain requires the installation of a cleanout when two eighth bends are used to create
a 90-degree change in direction?
a. A drain serving a water closet or urinal
b. Cleanouts are not required when changes in direction are made with eighth bends.
c. A drain that is below the main floor level of habitable space
d. A drain that receives the waste from a garbage disposer
https://www.tests.com/practice/Master-Plumber-Certification 2/5
5/20/24, 2:15 PM Master Plumber Practice Test
18. Only brass or plastic plugs can be used for sealing cleanout openings. (/practice/plumbing-practice-
test)
True
False
19. Which of the following do you need in order to size water piping for a water distribution system?
a. The rate at which the water will flow
b. The minimum quantity of water that a pipe of a specific material can deliver
c. The outside diameter of the pipe being used to deliver water
d. The amount of pitch that will be installed on the supply piping
e. Both a and d Quality starts with who
wrote the material.
20. A minimum distance of 100 feet is required between a pasture and a potable water well.
Our practice exam writer s :
True
False Dodge Woodson was a
master plumber and gas fitter
for over 30 years. He built his
21. Carbonated beverage dispensers require the installation of ______________ on the incoming water
... more
supply.
a. a vacuum breaker Charles Redecker is a
b. a butterfly-style backflow preventer master plumber instructor and
education director with the
c. a pneumatic backflow preventer National ... more
d. a vented backflow preventer that is not affected by carbon dioxide gas if the fixture does not have
an internal backflow preventer. Terry Lunt is a plumbing and
master craft instructor with
Associated Builders ... more
Sanitary Drainage Systems
Joseph Cromwell is a
master plumber in Illinois and
22. Sizing procedures for sewers is done with the same practices and principles that are used when Indiana. He was a continuing
sizing ________________. ... more
a. horizontal branches
b. soil stacks
c. vent stacks
d. building drains
23. Assume you are installing drainage piping in and around a food service area. Which of the
following locations are not allowed to have exposed drainage piping installed above them?
a. Areas used for storage
b. Surfaces provided for eating
c. Work areas
d. All of the above
e. B and c only
24. Suppose you want to turn a vertical drain to a horizontal position. Which of the following fittings
cannot be used for this purpose?
a. Quarter bend
b. Short-sweep fittings
c. Short-turn elbow
d. Sanitary tee
25. All fixtures and fittings installed in rooms housing psychiatric patients must be ________. (http://www.bbb.org/washington-
dc-eastern-pa/business-
a. supplied with only cold water reviews/test-publishers/tests-
b. firmly bolted to a fixed location com-in-lititz-pa-
c. protected from possible vandalism 235991163/#bbbonlineclick)
d. hospital approved
Find Other Tests GO
26. Suction equipment that is supplied with water falls under the same regulations of the plumbing
code that pertains to aspirators. (/#email) (/#facebook) (/#twi
True (https://www.addtoany.com/share#url=
False Plumber-Certification&tit
27. Drains from sterilizers must be connected to a drainage system through an indirect-waste Bookmark Page
connection.
True
False
https://www.tests.com/practice/Master-Plumber-Certification 3/5
5/20/24, 2:15 PM Master Plumber Practice Test
Water Heaters
28. Imagine that you are called upon to install a water heater for a triplex rental property. The water
heater will be used for domestic purposes. Which of the following is required for the satisfactory
installation?
a. An indirect waste and drain pan
b. An indelibly stamped metal plate that is permanently attached to the water heater in a clear and
conspicuous location that shows the maximum working pressure of the water heater
c. Pipe insulation on the inlet and outlet piping that extends a minimum of 18 inches above the water
heater
d. A stop and waste valve on the cold-water inlet pipe
e. Both b and d
29. Vacuum breakers are to be installed in conjunction with the inlet piping that serves a water heater.
True
False
30. The installation of an electric water heater requires which of the following to be in close proximity
to the fixture?
a. An ABC-type fire extinguisher
b. An electrical disconnect switch that is dedicated to only the water heater
c. A ventilation fan
d. A minimum of two light sources to allow for service work to be completed
e. Both a and b
31. Fifteen-pound roofing felt is the preferred cover material for aggregate installed in a seepage pit or
trench.
True
False
32. All gray water reservoirs are required to be fitted with a drain at the lowest point of the reservoir.
This drain is required to discharge to _____________.
a. a catch basin
b. a gravel bed for dissipation into approved soil
c. a sanitary drainage system
d. Any of the above
33. To avoid confusing gray water with potable water you must dye gray water. What color dye are you
required to use to identify water as gray water?
a. Blue or green
b. Green or yellow
c. Red or blue
d. Orange or green
Storm Drainage
34. Storm-water drainage systems have the same requirements for cleanouts as sanitary drainage
systems.
True
False
35. Which of the following types of valves are likely to be found in a storm-drainage system?
a. Stop valves
b. Flapper valves
c. Backwater valves
d. Stop-and-waste valves
36. Assume that you are drawing a piping diagram for the installation of a sump pump. Which of the
following are you going to show installed in the discharge piping?
a. Check valve
b. Stop valve
c. Backwater valve
d. Butterfly valve
Fuel Gas
37. What is the maximum allowable pressure for plastic gas piping that conveys natural gas?
a. 60 psig
b. 80 psig
c. 100 psig
d. 125 psig
https://www.tests.com/practice/Master-Plumber-Certification 4/5
5/20/24, 2:15 PM Master Plumber Practice Test
38. Unions installed on gas piping are required to ______________.
a. be dielectric unions
b. have a minimum diameter of 0.5 inches
c. be tested bi-annually for leaks
d. be visible
39. The maximum allowable pressure to be used when testing gas piping is ________.
a. 38 psig
b. 42 psig
c. 100 psig
d. 125 psig
About Us (/about) | Contact (/contact-us) | Terms of Sale / Refunds (/Terms-Of-Sale) | Sitemap (/sitemapv2)
Copyright © 2009-2024 Tests.com LLC - All Rights Reserved Terms of Use (/terms) / Privacy (/privacy)
https://www.tests.com/practice/Master-Plumber-Certification 5/5