Footing Size OK

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Isolated Footing(F3)

1 Footing Size Design

Load Pu 373 KN
Design Load P 273 KN

Moment in x dir Mux 10 KN-m


Moment in y dir Muy -1 KN-m

Column size cx 300 mm


cy 300 mm

SBC q 150 KN/sqm

Footing Size required A req 1.82 sqmm

L 1.50 meters
Footing Size Provided
B 1.50 meters
Area Provided A prvd 2.25 meters

Zx 0.56
Zx 0.56

Net upward pressure Nup 133 KNm2

Footing Size OK

2 Slab Design
lx 0.600
ly 0.600

Bending Moment in x dir Mx 36 KN-m


Bending Moment in y dir My 36 KN-m

Concrete fck 20 MPa


Steel fy 500 MPa

Minimum Depth Required dmin 116

Depth Provided D 500 mm


Clear Cover c 50 mm
Effective Cover d' 56 mm
Effective Depth d' 444 mm

Spacing c/c in mm
Area of Steel
12# 16# 20#
196 sqmm 578 c/c 1028 c/c 1607 c/c
196 sqmm 578 c/c 1028 c/c 1607 c/c

Ast across x direction 12 mm dia @ 150 mm c/c 754 sqmm


Ast across y direction 12 mm dia @ 150 mm c/c 754 sqmm
3 One Way Shear along x direction

Vu1 47 KN
ζv 0.070 MPa

ζc 0.164 MPa
Vc1 109 KN

One Way Shear Check OK

4 One Way Shear along y direction

Vu1 47 KN
ζv 0.070 MPa

ζc 0.164 MPa
Vc1 109 KN

One Way Shear Check OK

5 Two Way Shear


Vu2 339 KN
ζv 0.256 MPa

ks*ζc 1.118 MPa


Vc1 1477 KN

Two Way Shear Check OK


L= 1.50 meters

300

300
B= 1.50 meters

500 mm
250 mm

12 mm dia @ 150 mm c/c 12 mm dia @ 150 mm c/c