Analysis Report Apr
Analysis Report Apr
Page 1 of 7 | 05/05/2024
Downtime
Component: Unassigned
900 Pause through local keyboard IEC: Requested Shutdown 81 269h 41m 20s n/a
Customer Loss Allocation: Manufacturer
Component: Gearbox
111 No offline filtrat. For__days IEC: Forced Outage 8 108h 15m 37s n/a
Customer Loss Allocation: Manufacturer
Component: Sensors
159 Ext. RPM guard, ____ RPM S_ IEC: Forced Outage 14 76h 54m 9s n/a
Customer Loss Allocation: Manufacturer
Component: External-Stop
309 Pause over RCS __ IEC: Requested Shutdown 183 56h 59m 27s n/a
Customer Loss Allocation: Utility
Component: Gearbox
214 Low oil level, ____RPM/___°C IEC: Forced Outage 635 197h 45m 12s n/a
Customer Loss Allocation: Manufacturer
Component: Gearbox
150 High temp.Gear bearing _:___°C IEC: Forced Outage 4 44h 55m 44s n/a
Customer Loss Allocation: Manufacturer
Component: Gearbox
147 High gear temp:___°C/air:___°C IEC: Forced Outage 27 33h 48m 30s n/a
Customer Loss Allocation: Manufacturer
Component: Sensors
430 Transm. osc. ____ RPM, __ m/s IEC: Forced Outage 11 47h 33m 55s n/a
Customer Loss Allocation: Manufacturer
Component: Grid
899 Grid volt above stop lim ___% IEC: Out of Electrical Specification 58 22h 2m 1s n/a
Customer Loss Allocation: Utility
Component: Gearbox
80 Low oil pressure:____RPM/___°C IEC: Forced Outage 2 17h 55m 42s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
340 OVP active UDC_____V state __ IEC: Forced Outage 3 5h 10m 0s n/a
Customer Loss Allocation: Manufacturer
Component: Grid
315 ExEx low voltage L_: ___V IEC: Out of Electrical Specification 9 28h 40m 41s n/a
Customer Loss Allocation: Utility
Component: Grid
127 Extr. low voltage L_: ___V IEC: Out of Electrical Specification 2 4h 50m 0s n/a
Customer Loss Allocation: Utility
Page 2 of 7 | 05/05/2024
Code Description Default Allocation Frequency Duration Loss Production (MWh) Overridden
Component: Generator
201 Low temperature Gen_:___°C IEC: Forced Outage 2 20h 10m 0s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
901 DC Overvolt stop:____V state__ IEC: Forced Outage 3 2h 56m 13s n/a
Customer Loss Allocation: Manufacturer
Component: Sensors
212 Error temp.sensor R___, ____°C IEC: Forced Outage 3 23h 16m 20s n/a
Customer Loss Allocation: Manufacturer
Component: Sensors
343 Encoder signal error _:_____ IEC: Forced Outage 11 2h 11m 29s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
334 High cur.grid inv. L_:____A IEC: Forced Outage 1 0h 34m 50s n/a
Customer Loss Allocation: Manufacturer
Component: Brakes
160 High temperature brake disc IEC: Forced Outage 2 0h 58m 8s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
341 OVPHwErr UDC _____V state __ IEC: Forced Outage 2 0h 10m 43s n/a
Customer Loss Allocation: Manufacturer
Component: Grid
703 RT Dip exc.lim.:___%:_____e-2s IEC: Out of Electrical Specification 4 1h 3m 25s n/a
Customer Loss Allocation: Utility
Component: Grid
202 Frequency error 1: ___.__ Hz IEC: Out of Electrical Specification 6 0h 13m 32s n/a
Customer Loss Allocation: Utility
Component: Sensors
176 Error on all wind sensors IEC: Forced Outage 3 0h 6m 49s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
725 No RT, High Rotor Cur L_:____A IEC: Forced Outage 1 0h 1m 10s n/a
Customer Loss Allocation: Manufacturer
Component: Converter
339 Phase L:_ failure IEC: Out of Electrical Specification 2 0h 2m 20s n/a
Customer Loss Allocation: Utility
Component: Generator
219 Thermoerror Ext.Gen.Fan F____ IEC: Forced Outage 1 0h 11m 14s n/a
Customer Loss Allocation: Manufacturer
Component: Rotor
726 No RT, Ex.Hig.Rot.Cur L_:____A IEC: Forced Outage 1 0h 1m 46s n/a
Customer Loss Allocation: Manufacturer
Component: Turbine-Environment
144 High windspeed: __._ m/s IEC: Out of Environmental Specification 1 0h 2m 20s n/a
Customer Loss Allocation: Environmental
Page 3 of 7 | 05/05/2024
Downtime Overview - Component Downtime Overview - Component
1.5 MWh
9.1 MWh
0.0 h 20.4 h
56.8 h
36.6 MWh
152.5 h
402.8 h
13.6 MWh
59.8 h
102.8 MWh
150.0 h 295.2 h
0.0 h 64.0 MWh
21.9 MWh
Brakes Contactor / Circuit Breaker / Relay
Converter Electrical Components Brakes Contactor / Circuit Breaker / Relay
External-Stop Gearbox Converter Electrical Components
Generator Grid External-Stop Gearbox
Heaters / Coolers Pitch / Hyd Generator Grid
Power Supply / Converter Rotor Heaters / Coolers Pitch / Hyd
Sensors Turbine Maintenance Power Supply / Converter Sensors
Turbine-Environment Unassigned Turbine Maintenance Unassigned
Yaw System Yaw System
Page 4 of 7 | 05/05/2024
Turbine performance
500
Bottom 3: Lake Turkana G07
250
Farm Average OEM - VESTAS V52 Bottom 1: Lake Turkana E02 Bottom 2: Lake Turkana D12 Bottom 3: Lake Turkana G07 Bottom 4: Lake Turkana E04
Bottom 5: Lake Turkana E05 Top 1: Lake Turkana M12 Top 2: Lake Turkana K01 Top 3: Lake Turkana M13 Top 4: Lake Turkana M08 Top 5: Lake Turkana M07
30k
26472.6 437.5
170.3 0 0 0 2500.6
25k
23364.1
20k
Loss (MWh)
15k
10k
5k
0
Estimate Downtime Partial Curtailment Derate Degrade Icing Performance Actual
Page 5 of 7 | 05/05/2024
Wind distribution
Wind Distribution
2400 36k
2000 30k
1600 24k
1200 18k
800 12k
400 6k
0 0
2
12
22
7
17
4
14
3
13
16
19
8
18
1
11
21
0
1. 5
.5
.5
10
.5
.5
.5
15
.5
.5
.5
.5
.5
20
.5
.5
.5
0.
2.
3.
4.
5.
6.
7.
8.
9.
12
22
17
14
13
16
19
18
11
21
10
15
20
Wind Speed (m/s)
NNW NNE
40
Windspeed (m/s)
30
WNW ENE < 4 m/s
4-6 m/s
20
6-8 m/s
8-10 m/s
10
10-12 m/s
12-14 m/s
W 0 E 14-16 m/s
> 16 m/s
WSW ESE
SSW SSE
Page 6 of 7 | 05/05/2024