SM101 (+) Service Manual V2.0
SM101 (+) Service Manual V2.0
Manual
Service Manual
Model : SM-101(+)
1st Version
1 / 194
SM101+ Service
Manual
FAX:+86-021-57234090
2 / 194
SM101+ Service
Manual
Table of Content
1. GENERAL INFORMATION...................................................................................................8
1.1 Overall View......................................................................................................................................8
1.2 Display Panel......................................................................................................................................9
1.2.1 SM-101 Display..........................................................................................................................9
1.2.2 SM-101+ Display........................................................................................................................9
1.3 Key Panel...........................................................................................................................................9
1.4 Features............................................................................................................................................10
1.5 Specifications...................................................................................................................................11
1.5.1 Display..........................................................................................................................................11
1.5.1.1 SM-101 Display.....................................................................................................................11
1.5.1.2 SM-101+ Display...................................................................................................................11
1.5.2 Operating Conditions................................................................................................................11
1.5.3 Dimensions................................................................................................................................11
1.6 Key Functions..................................................................................................................................12
1.7 Indicators..........................................................................................................................................14
1.8 Label type.........................................................................................................................................15
2. SETUP......................................................................................................................................16
2.1 Indication of Assemble.....................................................................................................................16
2.2 Location of Switches and Connectors..............................................................................................17
2.3 Mode Change...................................................................................................................................18
2.4 Specification Setting........................................................................................................................18
2.4.1 Specification Entry(141)...........................................................................................................18
2.4.2 Specification Entry(142)...........................................................................................................19
2.4.3 Specification List......................................................................................................................20
2.5 Password Setting..............................................................................................................................60
2.5.1 Procedures of Password Setting................................................................................................60
2.5.2 Password Using.........................................................................................................................61
2.6 Clear Files........................................................................................................................................62
2.7 Default Specification Setting...........................................................................................................62
2.8 Calibration........................................................................................................................................64
2.8.1 Calibration Operation................................................................................................................64
2.8.2 Exit Calibration.........................................................................................................................65
2.9 Span Switch Status...........................................................................................................................65
2.10 Thermal Head Usage......................................................................................................................65
2.11 IP Address......................................................................................................................................66
2.12 Server IP Address...........................................................................................................................66
2.13 Subnet Mask...................................................................................................................................66
3 / 194
SM101+ Service
Manual
2.14 MAC Address.................................................................................................................................67
2.15 Serial No.........................................................................................................................................67
2.16 ASCII Character.............................................................................................................................67
3. PROGRAM MODE.................................................................................................................69
3.1 Programmable Files.........................................................................................................................69
3.2 General Explanation.........................................................................................................................70
3.3 Department Files..............................................................................................................................71
3.3.1 Program Department File..........................................................................................................71
3.3.2 Delete Department File.............................................................................................................72
3.4 Main Group Files.............................................................................................................................72
3.4.1 Program Main Group File.........................................................................................................73
3.4.2 Delete Main Group File............................................................................................................74
3.5 Program / Skip Item Data.................................................................................................................74
3.6 PLU Programming...........................................................................................................................76
3.6.1 Program PLU File(weighing item)...........................................................................................83
3.6.2 Program PLU File(non-weighing item)....................................................................................86
3.6.3 PLU [COPY] Function.............................................................................................................90
3.6.4 Delete PLU File........................................................................................................................91
3.6.5 Volume Discount & Mark Down print function.......................................................................91
3.7 Memory Status.................................................................................................................................93
3.8 Key Assignment...............................................................................................................................93
3.8.1 PLU Assignment.......................................................................................................................93
3.8.2 Function Key Assignment.........................................................................................................94
3.8.3 Delete Preset Key Assignment..................................................................................................95
3.9 Shop Name File................................................................................................................................95
3.9.1 Program Shop Name File..........................................................................................................95
3.9.2 Delete Shop Name File.............................................................................................................96
3.10 Advertisement File.........................................................................................................................97
3.10.1 Program Advertisement File...................................................................................................97
3.10.2 Delete Advertisement File.......................................................................................................98
3.11 Vender File.....................................................................................................................................98
3.11.1 Program Vender File...............................................................................................................98
3.12 Program Date And Time................................................................................................................99
3.13 Special Message File....................................................................................................................100
3.13.1 Program Special Message File..............................................................................................100
3.13.2 Delete Special Message File.................................................................................................101
3.14 Ingredient File..............................................................................................................................101
3.14.1 Program Ingredient File........................................................................................................102
3.14.2 Delete Ingredient File...........................................................................................................103
3.15 Text File.......................................................................................................................................103
4 / 194
SM101+ Service
Manual
3.15.1 Program Text File..................................................................................................................103
3.15.2 Delete Text File.....................................................................................................................104
3.16 Free Format File...........................................................................................................................105
3.16.1 General Information..............................................................................................................105
3.16.2 Print Area, Print Position and Print Angles...........................................................................106
3.16.3 Programming Parameter Of Print Items...............................................................................108
3.16.4 Free Format Entry.................................................................................................................110
3.16.5 Free Format Copy Function..................................................................................................114
3.16.6 Free Format Delete Function................................................................................................114
3.16.7 Sample of program a format by modifying the existing format...........................................115
3.17 Place File......................................................................................................................................118
3.17.1 Program Place File................................................................................................................118
3.17.2 Delete Place File...................................................................................................................118
3.18 Machine Setting............................................................................................................................119
3.19 Logo File......................................................................................................................................119
3.19.1 Pre-programming Logo Data................................................................................................119
3.19.2 Program Display & Keys Function.......................................................................................120
3.19.3 Programming Order..............................................................................................................121
3.19.4 Program Logo File................................................................................................................121
3.19.5 Delete Logo File...................................................................................................................122
3.20 Tax File........................................................................................................................................122
3.20.1 Program Tax File...................................................................................................................123
3.20.2 Delete Tax File......................................................................................................................123
3.21 Scroll Message File......................................................................................................................124
3.21.1 Program Scroll Message File................................................................................................124
3.21.2 Delete Scroll Message File...................................................................................................124
3.22 Scroll Sequence File.....................................................................................................................125
3.22.1 Program Scroll Sequence File...............................................................................................125
3.22.2 Enable or Disable Scroll Sequence File................................................................................126
3.22.3 Delete Scroll Sequence Number...........................................................................................127
3.23 Flexi Barcode File....................................................................................................................127
3.23.1 Program Flexi Barcode File..................................................................................................127
3.23.2 Program Flexi Barcode in PLU File.....................................................................................129
3.23.3 Delete Flexi Barcode.............................................................................................................129
3.24 ASCII Character Input Method....................................................................................................130
3.25 ASCII Code Input Method...........................................................................................................131
4. REGISTRATION MODE.....................................................................................................132
4.1 ON/OFF..........................................................................................................................................132
4.2 Reset and Weighing Check............................................................................................................132
4.3 Tare Subtraction.............................................................................................................................133
5 / 194
SM101+ Service
Manual
4.3.1 One touch Tare Subtraction.....................................................................................................133
4.3.2 Digital tare Subtraction...........................................................................................................133
4.4 PLU Call Up...................................................................................................................................133
4.4.1 Manual PLU Call Up..............................................................................................................133
4.4.2 PLU Call Up by Preset Key....................................................................................................134
4.4.3 PLU Call by Numeric Key (Auto PLU Call)..........................................................................134
4.5 Fix Operation..................................................................................................................................134
4.5.1 Fix Tare by FIX Key...............................................................................................................134
4.5.2 Fix PLU by FIX Key...............................................................................................................135
4.5.3 Fix Unit Price by FIX Key......................................................................................................135
4.6 Operation Mode Change................................................................................................................135
4.7 Item Label Printing in Manual Mode.............................................................................................136
4.7.1 Label Printing for PLU Item...................................................................................................136
4.7.2 Label Printing for NON-PLU Item.........................................................................................137
4.8 Total Label Printing in Manual Mode............................................................................................137
4.8.1 Sales Transaction....................................................................................................................137
4.8.2 [PRICE DISCOUNT] Function Key in Add Mode................................................................138
4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode............................................................138
4.9 Data Correction..............................................................................................................................139
4.9.1 On The Spot Correction..........................................................................................................139
4.9.2 Void by Item Correction..........................................................................................................140
4.10 Item Label Printing in Pre-pack Mode.........................................................................................141
4.10.1 Item Label Issue for PLU Item.............................................................................................141
4.10.2 Item Label Issue for NON-PLU Item...................................................................................142
6 / 194
SM101+ Service
Manual
6. RESET REPORT MODE.....................................................................................................152
6.1. Reset Report..................................................................................................................................152
6.1.1 Sales Daily / Monthly/Term Reset Report..............................................................................152
6.1.2 Traceability Reset Report........................................................................................................152
6.1.3 Clerk Log File Reset Report...................................................................................................152
7. ADJUSTMENT......................................................................................................................153
7.1 Peel Sensor Voltage and Label Sensor Sensitivity Adjustment.....................................................153
7.1.1 Peel Sensor Voltage.................................................................................................................154
7.1.2 Label Sensor Sensitivity.........................................................................................................154
7.2 Adjustment of Printing Position.....................................................................................................156
7.3 Voltage CheckPoint........................................................................................................................157
8. SOFTWARE SETTING........................................................................................................158
8.1 Software Version Upgrade.............................................................................................................158
8.1.1 Cable & Connection................................................................................................................158
8.1.2 PC Setting & Programmer Version.........................................................................................159
8.1.3 Updating Steps........................................................................................................................159
8.1.4 Cable Connection....................................................................................................................165
8.1.5 Update Steps...........................................................................................................................166
8.2 Facility Tool...................................................................................................................................170
8.2.1 Program Setup.........................................................................................................................170
8.1.2 Run the Program.....................................................................................................................172
8.1.3 File Edit...................................................................................................................................172
8.1.4 File Save and Exit Program....................................................................................................175
9. INTERFACE..........................................................................................................................176
9.1 PC Interface....................................................................................................................................176
9.2 Scale Ethernet Address...................................................................................................................176
9.3 Scale IP Address.............................................................................................................................177
9.4 Connection Method........................................................................................................................178
9.5 Wire Configuration........................................................................................................................179
9.5.1 Ethernet Wire - Straight Cable and Crossover Cable..............................................................179
9.5.2 RS232C Wire..........................................................................................................................181
9.5.3 Cash Drawer Connector..........................................................................................................181
10. MISCELLANEOUS............................................................................................................182
10.1 Flexible Barcode Setting Guide...................................................................................................182
10.2 SM-101+ Traceability Setting Guide...........................................................................................184
10.3 SM-101+ Nutrition Fact Setting Guide........................................................................................189
10.4 SM101+ Server/Client Manual....................................................................................................190
7 / 194
SM101+ Service
Manual
10.4.1 Summary...............................................................................................................................190
10.4.2 Spec.......................................................................................................................................190
10.4.3 Setting...................................................................................................................................191
10.4.5 Effect.....................................................................................................................................191
8 / 194
SM101+ Service
Manual
1. GENERAL INFORMATION
1.1 Overall View
Bench Type
Elevated Type
9 / 194
SM101+ Service
Manual
Elevated Type
10 / 194
SM101+ Service
Manual
11 / 194
SM101+ Service
Manual
1.4 Features
Digital printing scale consists of electronic cash registers function and label
printing function.
High-speed, high reliability thermal head printer.
Easy paper handing achieved special designed mechanism.
Built-in clock automatically updates date and time.
Quick response to weight changes.
Capacity : 3kg, 6kg, 12kg, 15kg, 30kg, 6lb, 12lb, 15lb and 30lb.
Resolution : Display Resolution 1/3,000.
: Internal Resolution 1/90,000.
Calibrating by software.
Customer and operator displays (optional customer pole display).
25 digits x 19 segments TN type LCD (SM-101) / 202 x 32 pixels FSTN type
LCD
(SM-101+), with back-light for numeric digit and character display.
67 (bench and pole) / 101 membrane keys
a. ON/OFF key.
b. 10 Numeric keys, to key in numeric data.
c. 40 / 74 Preset keys, to preset PLU or function into the key.
d. 16 Operational keys, to perform various functional operations.
18 data files for Department, Main Group, PLU, etc.
Various reports.
Ethernet function.
Optional wireless Ethernet card.
RS232C interface for data communication and barcode scanner connection.
Optional cash drawer.
Compact housing.
12 / 194
SM101+ Service
Manual
1.5 Specifications
1.5.1 Display
1.5.1.1 SM-101 Display
25 digits x 19 segments TN type LCD with back-light.
Tare Weight display : 4 digits.
Weight display : 5 digits.
Unit Price display : 6 digits.
Total Price display : 7 digits.
1.5.3 Dimensions
Platter size : 386(W) x 270(D) mm.
Overall size
a) Bench 386(W) x 416(D) x 128(H) mm.
b) Pole 386(W) x 478(D) x 480(H) mm.
c) Elevated 386(W) x 416(D) x 550(H) mm.
13 / 194
SM101+ Service
Manual
PRESET KEY
NUMERIC KEYS
TARE KEY
CLEAR KEY
RE-ZERO KEY
PREPACK KEY
CHANGE KEY
14 / 194
SM101+ Service
Manual
MULTIPLLE KEY
CLERK KEY
VOID KEY
PLU KEY
FEED KEY
PRINT KEY
15 / 194
SM101+ Service
Manual
︽,︾ Decrease/Increase Only used when Setting SPEC 141 & 142
<<,>> Select parameter data such as SPEC data. Move cursor left or right.
1.7 Indicators
ZERO : On when zero point is adjusted and weight is stable.
NET : On when tare subtraction is performed.
FIX T : On when tare weight is fixed.
FIX P : On when PLU or unit price is fixed.
P : On when pre-pack mode is chosen; indicate capital letter is use in PLU
programming.
M : On when manual mode is chosen.
V1 ~ V4: On when vendor transaction entries (department entry or PLU entry) are
performed.
LABEL: On when label printing mode is chosen.
R : On when in R (normal operation) mode.
X : On when in X (read report) mode.
16 / 194
SM101+ Service
Manual
S : On when in S (programmable item setting) mode.
Z : On when in Z (reset report and system maintenance) mode.
17 / 194
SM101+ Service
Manual
Note: Labels must be winding outwards (on top backing paper) and not inwards (under backing
paper) within the core (see diagram above). If labels are wound wrongly, printing problem may
result. We do not recommend the use of varnish labels.
18 / 194
SM101+ Service
Manual
2. SETUP
2.1 Indication of Assemble
19 / 194
SM101+ Service
Manual
20 / 194
SM101+ Service
Manual
Bubble Adjustment
Bubble
Place the scale on the flat surface and adjust the four legs until the bubble on the level is in the
centre as shown above.
21 / 194
SM101+ Service
Manual
2.2 Location of Switches and Connectors
Power
Switch
Ethernet
Port
Span
Switch
22 / 194
SM101+ Service
Manual
2.3 Mode Change
DISPLAY
OPERATION REMARK
PT kg $/kg $
0.000 0.000 0.00 0.00 Weight mode.Lamp R turns on.
[MODE],[MODE] Enter X mode.Lamp X turns on.
XMODE
(within 3 seconds)
[MODE] S1 → PLU FILE Enter S mode.Lamp S turns on.
[MODE] Z1.0 RESET SALES DAILY Enter Z mode.Lamp Z turns on.
[MODE] PWD X 0 SET Enter Password Set mode.Lamp X flicker
[MODE] 0.000 0.000 0.00 0.00 Back to Weight mode.Lamp R turns on.
23 / 194
SM101+ Service
Manual
* Note 1 escape to Z mode.
* Remark: The Weight in the display window will display the SPEC number. The Unit Price
window will display the new value setting entered. The Total Price window will display
the old value setting. The selection you have made will be highlighted in the dot matrix
display. Please use [︾] to increase spec count, [︽] to decrease spec count, [*] to store a
new value and [PLU] to save spec setting.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Press SPAN
Z1.0 RESET SALES DAILY SPAN SWITCH is on(ENABLE).
SWITCH
Enter [1][4][2] while depressing
XXX XXX
[Rezero]+[1][4][2] SPEC 600 [Rezero].
(setting) (former)
XXX:SPEC data
[ ︾ ]key only increase specification
[︾] SPEC 601 XXX XXX
count, it does not update SPEC data.
[ ︽ ]key only decrease specification
[︽] SPEC 600 XXX XXX
count, it does not update SPEC data.
It goes to a designed specification
[6][1][5] SPEC 600 615 XXX
count.
[X] SPEC 615 XXX XXX
(600~719 is enabled)
[>>] key select SPEC data.
[>>] SPEC 615 XXX XXX
Move cursor right.
[<<] key select SPEC data.
[<<] SPEC 615 XXX XXX
Move cursor left.
[1] SPEC 615 001 XXX [*] key to update specification,
[*] SPEC 616 XXX XXX increase specification count.
[2] SPEC 616 002 XXX
[C] SPEC 616 000 XXX Clear the enter data.
[PLU] Store the updated specification and
Z1.0 RESET SALES DAILY
* Note 1 escape to Z mode.
Note 1: If press [T] key, it does not store the updated specification and escape to Z mode.
* Remark: The Weight in the display window will display the SPEC number. The Unit Price
window will display the new value setting entered. The Total Price window will
display the old value setting. The selection you have made will be highlighted in the
24 / 194
SM101+ Service
Manual
dot matrix display. Please use [︾] to increase spec count, [︽] to decrease spec count,
[*] to store a new value and [PLU] to save spec setting.
25 / 194
SM101+ Service
Manual
07 Total Barcode
0 F1F2 CCCCC XCD XXXX CD 16 F1F2 CCC XXXXXXX CD All are 13 digits non-
1 F2 CCCCCC XCD XXXX CD 17 F1F2 CC XXXXXXXX CD PLU barcode unless
2 F1F2 CCCCC 0 XXXX CD 18 CCC WWWW PPPPP CD otherwise stated.
3 F1F2 CCCCCC XXXX CD 19 No Barcode #1 13 digits PLU
4 F1F2 CCCCC XXXXX CD 20 F1F2 CCCCC PCD XXXX CD barcode
5 F2 CCCCCC XXXXX CD 21 F1F2 RRRRR XXXXX CD #4 #2 8 digits PLU
6 F2 CCCCC XXXXXX CD 22 F2 CCCCC XXXXXX CD barcode
7 F1F2 CCCCCCCCCC CD #1 23 FFF CCCC PPPPP CD #3 8 digits non-PLU
8 F1F2 CCCC XXXXXX CD 24 F1F2 CCCCC WWWWW CD barcode
#4 For SF
9 F1F2 CCCC CD #2 25 F2 CCCCC WWWWW 0 CD
#5 Non Barcode
10 F2 CC XXXX CD #3 26 F1F2 CCCCCC WWWW CD
11 No Barcode 27 CCCCCCC XXXXXX #5
12 F1X2 CCCCC XCD XXXX CD 28 F1F2 CCC XXXXXXX CD
13 F1X2 CCCCCC XXXX CD 29 F2 CCCCCCC WWWW CD
14 F1F2 CCCC XCD XXXXX CD 30 F1F2 CC NNN PPPPP CD
15 F2 CCCCC XCD XXXXX CD 31 F1F2 C NNNN PPPPP CD
26 / 194
SM101+ Service
Manual
27 / 194
SM101+ Service
Manual
08 Left Side Data of Total Label
0 Scale No. 3 Clerk No.
1 Last Accumulated Item Code 4 Fixed No.
2 Receipt No. 5 Total Label No.
13 Print Readable Character of F1 for Item and Total Barcode (for EAN only)
0 No Print 1 Print
28 / 194
SM101+ Service
Manual
4 T5 (U2) [U3] 16 F1 (T10) [F1] Formats in [ ] are for
5 T6 (U3) [U4] 17 F2 (F1) [F2] CA only.
6 T7 (U4) [U5] 18 F3 (F2) [F3]
7 T8 (U5) [U6] 19 F4 (F3) [F4] F1 to F8 are Free
8 T9 (U6) [U7] 20 F5 (F4) [F5] Format.
9 T10 (U7) [U8] 21 F6 (F5) [F6]
10 T11 (U8) [T5] 22 F7 (F6) [F7]
11 T12 (T5) [T6] 23 F8 (F7) [F8]
24 - (F8) -
30 Selection of CDV
0 Inhibit 1 Allow For SF.
31 CDV Type
0 CDV 1 Tear-off For SF.
32 CDV Modulus
0 Modulus 10 1 Modulus 11 For SF.
Effective when
SPEC30 and 31 = 1.
33 On Spot Correction
0 Allow 1 Inhibit
34 Search Correction
0 Allow 1 Inhibit
29 / 194
SM101+ Service
Manual
0 Low 2 High-mid
1 Mid 3 High
39 Calling of PLU
0 Manual 2 Time-out Related to SPEC40.
1 Auto 3 Intelligent
41 Unit Price of Weigh PLU Can Use for Price of Non-weigh PLU and Vice Versa
0 Allow 1 Inhibit Effective when
SPEC643 = 0.
43 Main Usage for Commodity Name, Shop Name and Special Message
0 Receipt 1 Label
44 Tare Override
0 Allow 1 Inhibit
45 Item Printing
0 Allow 1 Inhibit
30 / 194
SM101+ Service
Manual
0 7 Bits 1 8 Bits Apply to both RS-
232C and RS-485
ports setting for SM-
300.
61 Floating Clerk
0 Inhibit 1 Allow
31 / 194
SM101+ Service
Manual
63 SM-90 and DI-10 RS-232C Communication
0 No 1 Yes
83 Selection of Markdown
0 No Markdown 2 Total Price Markdown
1 Unit Price Markdown 3 Unit and Total Price Markdown
32 / 194
SM101+ Service
Manual
84 Sub-total Function Key Enable
0 Allow 1 Inhibit
87 Label Type
0 Gap 1 No Gap
90 Sub-total Markdown
0 No Markdown 1 Markdown
98 Quantity and Unit Symbol Print Out for Non-weigh Item in Manual Mode
0 Allow 1 Inhibit
33 / 194
SM101+ Service
Manual
0 Enable 1 Disable
34 / 194
SM101+ Service
Manual
122 Prepare Mode after Power On
0 Manual Mode 1 Prepack Mode Always set to 0 for
SM-200.
133 Change All PLU Default Format when Default SPEC Change
0 Yes 1 No
35 / 194
SM101+ Service
Manual
141 Year Format
0 YY 1 YYYY
151 Change Sell by Date or Used by Date when Packed Date Changed
0 No 1 Yes
36 / 194
SM101+ Service
Manual
162 Item Code Function Key Enable
0 Enable 1 Disable
168 GB Code
0 GB Code 1 Shift GB Code For CN and MS only.
175 30 lb to 15 kg Conversion
0 Disable 1 Enable For UK.
37 / 194
SM101+ Service
Manual
183 PLU Clear after 10 seconds Time-out
0 No 1 Yes
185 Weigh PLU Can Use for Non-weigh PLU and Vice Versa Function Key Enable
0 Disable 1 Enable
38 / 194
SM101+ Service
Manual
202 Printing of Item Label when Barcode Data Overflow
0 Print 1 No Print
207 Weight Decimal Point Position for Barcode and Label Printing
0 Same as SPEC607 1 0.000 Effective when
SPEC607 = 2.
218 Zero Unit Price for Unit Price Change Function Key
0 Inhibit 1 Allow
39 / 194
SM101+ Service
Manual
0 Disable 1 Enable Effective when
SPEC1 = 0 or 2.
231 Zero Unit Price for PLU and Unit Price Override
0 Inhibit 1 Allow
40 / 194
SM101+ Service
Manual
240 Voucher Payment Function Key
0 Inhibit 1 Allow
245 Print Sell by Date or Used by Date when Date Equals Packed Date
0 Yes 1 No
41 / 194
SM101+ Service
Manual
259 Auto Print Sub-total Label in Prepack
0 No 1 Yes
42 / 194
SM101+ Service
Manual
277 Real Time Buffer
0 No 4 5 Days
1 2 Days 5 6 Days
2 3 Days 6 7 Days
3 4 Days 7 Unlimited
279 U1 Self-service
0 Disable 1 Enable For U1 only.
43 / 194
SM101+ Service
Manual
0 6 Lines 1 12 Lines
44 / 194
SM101+ Service
Manual
313 Price Change Log File
0 Disable 1 Enable For CA.
45 / 194
SM101+ Service
Manual
331 Default ITF for Barcode
0 Disable 1 Enable
46 / 194
SM101+ Service
Manual
0 Print 1 No Print
47 / 194
SM101+ Service
Manual
For image 0 and 180
0 Disable 1 Enable
degree only
48 / 194
SM101+ Service
Manual
0 Allow 1 Inhibit
49 / 194
SM101+ Service
Manual
428 PRINT Tax List on Receipt
0 Allow 1 Inhibit Effective when
SPEC603 = 1
442 Change Main Group Code for Auto Plu Call Function Key Enable
0 Allow 1 Inhibit
443 Prefix Fixed Code to PLU Code for Auto PLU Calling
0 No 2 2 Digits Effective when
1 1 Digit 3 3 Digits Spec39 = 1, Spec40
=0
50 / 194
SM101+ Service
Manual
0 Allow 1 Inhibit
51 / 194
SM101+ Service
Manual
467 India Code128
0 Inhibit 1 Allow For ID.
471 Print Unit Price and Total Price on Label when Price is 0
0 Allow 1 Inhibit
474 Item Barcode on Item Label for Total Price in 2nd Currency
0 Inhibit 1 Allow For FR only.
485 Change from Receipt Mode to Label Mode while Data in Vender Memory
0 Allow 1 Inhibit
52 / 194
SM101+ Service
Manual
489 Identification Digit for Flexi-Barcode
0 No 1 Yes For KE.
500 Wait for ‘ACK’ when record size is larger than 1460 Bytes
0 Allow 1 Inhibit For AR.
502 Continue Adding and Voiding Last Receipt Function Key Enable
0 Inhibit 1 Allow For SN.
53 / 194
SM101+ Service
Manual
2 6
518 Quantity Entry Type for Average Price and Weight Label Function
0 Quantity 1 Percentage
54 / 194
SM101+ Service
Manual
0 Inhibit 1 Allow
55 / 194
SM101+ Service
Manual
[REZERO] + [1][4][2] WEIGHT AND MEASUREMENT SPECIFICATION
(Span Switch must be ENABLE when accessing this mode.)
SPEC
SPECIFICATION DESCRIPTION SM-100 SM-101
NO.
603 Tax
0 No Tax 1 Tax
614 Zero Setting Range when Weight Reset Switch is On or Zero Tracking
0 +/- 10% of Capacity 2 +/- 2% of Capacity
(Power on Start Point +/- 6000 IR) (Power on Start Point +/- 1200 IR)
1 +/- 5% of Capacity 3 +/- 0.6% of Capacity
(Power on Start Point +/- 3000 IR) (Power on Start Point +/- 360 IR)
Zero Setting Range when Weight Reset Switch is On or Zero Tracking
0 ±2% F.S. 1 Combination (for Sri Lanka)
56 / 194
SM101+ Service
Manual
1 2 3 10
57 / 194
SM101+ Service
Manual
0 Inhibit 1 Allow
640 Price Accumulation with Weight Change More than +/- 10d
0 Inhibit 1 Allow
641 Accumulation Available Only after Scale Shows Weight is Equal Zero
0 Inhibit 1 Allow Effective when
SPEC640 = 0.
58 / 194
SM101+ Service
Manual
0 Function Key Precede Numeric 1 Numeric Key Precede Function
Key Key
59 / 194
SM101+ Service
Manual
0 Normal 2 High
1 Slow 3 Very High
676 Right Side Barcode Data Shifting for Item and Total Barcode
0 No 3 Left Shift Twice (left shift valid for
1 Right Shift Once 4 Left Shift 3 Times quantity only)
2 Right Shift Twice 5 Left Shift Once
680 Tare Clear when Exit From Z mode, Password Mode, Changing of Customer, and
Weight and Measure Specification
0 No 1 Yes
60 / 194
SM101+ Service
Manual
683 Foreign Code for Standard Countries
0 Inhibit 2 Korean Code Not effective for AA,
1 GB Code CN, HK, KE, MS and
TW.
692 RESERVED
697 RESERVED
61 / 194
SM101+ Service
Manual
1 Truncation
62 / 194
SM101+ Service
Manual
63 / 194
SM101+ Service
Manual
64 / 194
SM101+ Service
Manual
65 / 194
SM101+ Service
Manual
Mode change
DISPLAY
OPERATION REMARK
PT kg $/kg $
Z mode.
Z1.0 RESET SALES DAILY
Lamp Z turns on.
[Rezero]+[2][3][0] CLEAR PLU FILE PLU file.
[︾] CLEAR VENDER DATA Vender transaction data.
[︾] CLEAR REPORT FILES Report files.
[︾] CLEAR MEMORY DATA All files in memory.
[*] CLEAR MEMORY Y-C N-T [C] to clear file data,[T] to quit.
[C] or [T] Z1.0 RESET SALES DAILY Return to Z mode.
Country Set
DISPLAY
OPERATION REMARK
PT kg $/kg $
Z1.0 RESET SALES DAILY Z mode.Lamp Z turns on.
[Rezero]+[8][8] COUNTR Set country setting.
SPEC 2-STD
[2][2] Y
66 / 194
SM101+ Service
Manual
COUNTR [>>],[<<] or [X] to select country.
[>>] SPEC 3-CN
Y [*] to update country setting.
DEFAUL [C] to load default SPEC setting,
[*] LOAD SPEC Y-C N-T
T [T] to skip.
TYPE Set scale type.
[C] SCALE POLE
→
TYPE [X],[ - ] to select type,[*] to
[X] SCALE BENCH
→ update type setting.
[*] SCALE CAP. → 3KG Set scale capacity.
[X],[ - ] to select capacity,[*] to
[X] SCALE CAP. → 6KG
update capacity setting.
[*] SCALE RES. → 1/3000S Set resolution.
[X],[-] to select resolution,[*] to
[X] SCALE RES. → 1/3000M
update resolution setting.
MEMO [C] to clear memory,[T] to skip.
[*] CLEAR Y-C N-T
RY
[C] Z1.0 RESET SALES DAILY Return to Z mode.
Note 1: For the first using of SM-101+,Please take this operation for initialization.
Note 2: Enter a number that represent a country in the country list (refer to the table
below) to initialise and country set.
COUNTRY LIST
No. Country Code Country No. Country Code Country
0 AA Japan 27 CA (LB) Canada (Lb)
1 U1 U.S.A. 28 AG Argentina
2 STD Standard 29 MX Mexico
3 CN China 30 BZ Brazil
4 HK Hong Kong 31 CE Chile
5 TW Taiwan 32 EA Egypt
6 EX Export 33 JD Jordan
7 KE Korea 34 LN Lebanon
8 AR Australia And New Zealand 35 IRN Iran
9 SF South Africa 36 CR Canary Islands
10 CS Cyprus 37 TL Thailand
11 GC Greece 38 EC European Community
12 TU Turkey 39 NL Netherlands
13 CV Czech Republic 40 BG Belgium
14 HG Hungary 41 SA Saudi Arabs
15 PL Poland 42 IC Iceland
16 UR Russia 43 IE Indonesia
17 AS Austria 44 CB Cuba
18 DM Denmark 45 KY Kenya
67 / 194
SM101+ Service
Manual
19 FL Finland 46 IR Israel
20 NW Norway 47 VY Slovenia
21 SD Sweden 48 MS Malaysia
22 PG Portugal 49 SN Spain
23 UK United Kingdom 50 VZ Venezuela
24 IL Ireland (Kg) 51 CO Croatia
25 IL (LB) Ireland (Lb) 52 MA Macedonian
26 CA Canada (Kg)
2.8 Calibration
Prior to Calibration, please refer that the specification indicating weight capacity,
minimum graduation, and load cell sensitivity are correctly set.
Caution:
It can only work when SPAN SWITCH is on (ENABLE).
Before Calibrating, please enter Z mode.
DISPLAY
OPERATION REMARK
PT kg $/kg $
SPAN SWITCH is on
Press SPAN SWITCH Z1.0 RESET SALES DAILY
(ENABLE).
Enter [8][7][1][5] while
[Rezero]+[8][7][1][5] CAL 00
depressing [Rezero].
Ensure no weight on Calibrating zero point.
------
platter,[*]
After storing the zero
CAL SP
Point ‘IR’ count
Put full capacity Calibrating Span.
------
weight on platter.[*]
Go back to Z mode. Lamp Z
After calibration Z1.0 RESET SALES DAILY
always light.
68 / 194
SM101+ Service
Manual
69 / 194
SM101+ Service
Manual
2.8.2 Exit Calibration
DISPLAY
OPERATION REMARK
PT kg $/kg $
SPAN SWITCH is
Press SPAN SWITCH Z1.0 RESET SALES DAILY
on(ENABLE).
Enter [8][7][1][5] while
[Rezero]+[8][7][1][5] CAL 00
depressing [Rezero].
Escape to Z mode. Lamp Z
[T] Z1.0 RESET SALES DAILY
always light
[Rezero]+[8][7][1][5] CAL 00 The ‘IR’ count will be taken as
[*] ------ the zero point ‘IR’ count.
After storing the zero Calibrating Span.
CAL SP
Point ‘IR’ count
Escape to Z mode. Lamp Z
[T] Z1.0 RESET SALES DAILY
always light.
70 / 194
SM101+ Service
Manual
2.11 IP Address
To check and modify the scale IP address.
71 / 194
SM101+ Service
Manual
2.15 Serial No
To check the serial NO
72 / 194
SM101+ Service
Manual
73 / 194
SM101+ Service
Manual
3. PROGRAM MODE
3.1 Programmable Files
In Programming Mode, there are two ways to select the Programming File by using
different keys such as:
Enter the Number key.
Press [︽] key or [︾] key to select the Data File.
[3] Main Group Programming [1] [9] Program or Skip Item Data
74 / 194
SM101+ Service
Manual
75 / 194
SM101+ Service
Manual
DEPARTMENT FILE
DEPARTMENT file is the largest category whose items are like MEAT, FISH,
VEGETABLE or DELICATESSEN etc.
PLU FILE
76 / 194
SM101+ Service
Manual
PLU File is the smallest category including items such as BEEF SLICE, BEEF
SHOULDER and BEEF SIRLOIN. You can link the PLU to a Main Group in the
77 / 194
SM101+ Service
Manual
set the department name.
Enter DEPT. name(use letter
keys)(Ex. “MEAT” for Dept. No
1)
[M][E][A][T] S2.1 DEPT MEAT NAME 4
The methods of ASII letter input
refer to 2.16 ASSII Character
Input Method.
Store the department file, back to
[PLU] S2 → DEPT FILE
S mode.
Note1: Number after "NAME" in Total display shows the position of the cursor.
Note2: The DEPT. No.1 to No.99 are available for programming.
(No.97 is default No. for PLU programming, and the PLUs which are not linked
to
any DEPT No. are assigned to No.97)
(Non-PLU files (Weighing items) are assigned to DEPT code No.98)
(Non-PLU files (Non-weighing items) are assigned to DEPT code No.99)
Note3: The Department names programmed are not printed on the label/receipt but are
for reporting.
Note1: When the MAIN GROUP FILE exists under the Department File, the
Department Number cannot be deleted. In addition, the Department Number 97, 98
and 99 cannot be deleted.
78 / 194
SM101+ Service
Manual
79 / 194
SM101+ Service
Manual
number 1.
Store the Main Group file, back to
S mode. If you want to exit without
[PLU] S3 → MGROUP FILE
saving data, press [◇] key and then
follow by [C] key
Note1: For tax rate programming, refer to 3.20 Tax File in S Mode. if not necessary
to link the Tax Number, press [*] key to enter next selection. This procedure
will skip if SPEC 603 is set to "NO TAX".
Note2: Number after "NAME" in Total display shows the position of the cursor.
Note3: The Main Group No.1 to No.997 are available for PLU programming.
(No.997 is default No. for PLU programming, and the PLUs which are
not linked to any Main Group No. are assigned to No.997)
(Non-PLU files (Weighing items) are assigned to Main Group code
No.998)
(Non-PLU files (Non-weighing items) are assigned to Main Group
code No.999)
Note4: The Main Group names programmed are not printed on the
label/receipt but are for reporting.
Note5: Each Main Group No. must be linked to the exiting Dept. No..
80 / 194
SM101+ Service
Manual
Delete M.G. file 111,back to S
[C] S3 → MGROUP FILE
mode.
Note1: When the PLU FILE exists under the Main Group File, the Main Group
Number cannot be deleted. In addition, the Main Group Number 997, 998 and 999
cannot be deleted.
81 / 194
SM101+ Service
Manual
30 [NUTRI] 30. Nutrition NUTRI
31 [ITFSEL] 31. ITF Selection ITFSEL
32 [REFPLU] 32. Reference PLU No. REFPLU
33 [SECPLU] 33. Security PLU SECPLU
34 [COUPLU] 34. Coupled PLU COUPLU
35 [DAY WK] 35. Discount day of the week DAYWK
36 [ADD-ON] 36. EAN 5 Digit ADD-ON ADDON
37 [TAX] 37. TAX No. TAX
38 [PRICE2] 38. 2nd Price PRICE2
39 [% TARE] 39. Proportional Tare PROTARE
40 [CUSDIS] 40. Customer Discount CUSDIS
41 [RESDIS] 41. Restaurant Discount RESDIS
42 [STADIS] 42. Staff Discount STADIS
43 [TRACE] 43. Traceability Discount TRACE
44 [TEMP] 44. Storage Temperature TEMP
45 [PACK.I] 45. Pack. Indicator PACKI
46 [M1BARC] 46. Multi Barcode 1 M1BARC
47 [M2BARC] 47. Multi Barcode 2 M2BARC
48 [TM1BAR] 48. Total Multi Barcode 1 TM1BAR
49 [TM2BAR] 49. Total Multi Barcode 2 TM2BAR
50 [U.PRIC] 50. Unit Price Selection UPRIC
51 [PLUSCR] 51. PLU Scroll (U1 only) PLUSCR
52 [PLUTEX] 52. PLU Linked Text Field PLUTEX
Note1: Press [*] key to next parameter or [] key to previous parameter and press [X]
key to select PROGRAM or SKIP for each parameter, if necessary.
Note2: If you want to exit without saving, press [◇] key follow by [C] key.
82 / 194
SM101+ Service
Manual
PLU file for weighing item and non-weighing item listed below can be programmed
according to the following order.
Weighing Item
Step PLU File (weighing Item) Remarks
P1.0 PLU No.
P1.1 Unit Price (6 digits)
P1.2 Label Format for the 1st label Refer to Label Format List.
P1.3 Label Format for the 2nd label Free format No.1~99 only.
P1.4 Commodity Name Font Size
P1.4 Commodity Name
P1.5 Selection of ITF Barcode Format
P1.6 Bar Code Selection
P1.7 Flag data * Digits of Flag and Item data can be selected in the
P1.8 Item Code No. barcode type selection in P1.6.
P1.9 Item Code No. (Lower 4 digits) Only when Item Code is more than 6 digits.
P1.10 Right Side Data of Item Barcode Only when Spec02 set to 3.
P1.11 Selection of EAN ADD-ON
P1.12 Main Group No.
P1.13 Select whether to print Sell by date
83 / 194
SM101+ Service
Manual
* If No Print is selected, Sell- by Date in P1.12 is
P1.14 Sell by date (Days after the current date)
skipped.
* If No Print is selected, Key in selection in P1.14 Sell-
P1.15 Select whether to print Sell by time
by time in P1.15 is skipped.
P1.16 Select key-in data or present time * If P1.14 select CLOCK TIME, Key in selection in
P1.17 Sell by Time (If Key-In is selected) P1.15 is skipped.
P1.18 Select whether to print Used by date * If No Print is selected, Used- by Date in P1.17 is
P1.19 Used by date (days after Packed date) skipped.
P1.20 Select whether to print Packed date * If No Print is selected, Packed Date in P1.19 is
P1.21 Packed Date (days after actual packed date) skipped.
84 / 194
SM101+ Service
Manual
85 / 194
SM101+ Service
Manual
86 / 194
SM101+ Service
Manual
Non-Weighing Item
Step PLU File (Non-weighing Item) Remarks
P1.0 PLU No.
P1.1 Unit Price (6 digits)
P1.2 Label Format for the 1st label Refer to Label Format List.
P1.3 Label Format for the 2nd label Free format No.1~99 only.
P1.4 Commodity Name Font Size
P1.4 Commodity Name
P1.5 Selection of ITF Barcode Format
P1.6 Bar Code Selection
P1.7 Flag data * Digits of Flag and Item data can be selected in the
P1.8 Item Code No. barcode type selection in P1.6.
P1.9 Item Code No. (Lower 4 digits) Only when Item Code is more than 6 digits.
P1.10 Right Side Data of Item Barcode Only when Spec02 set to 3.
P1.11 Selection of EAN ADD-ON
P1.12 Main Group No.
P1.13 Select whether to print Sell by date * If No Print is selected, Sell- by Date in P1.12 is
P1.14 Sell by date (Days after the current date) skipped.
* If No Print is selected, Key in selection in P1.14 Sell-
P1.15 Select whether to print Sell by time
by time in P1.15 is skipped.
P1.16 Select key-in data or present time * If P1.14 select CLOCK TIME, Key in selection in
P1.17 Sell by Time (If Key-In is selected) P1.15 is skipped.
P1.18 Select whether to print Used by date * If No Print is selected, Used- by Date in P1.17 is
P1.19 Used by date (days after Packed date) skipped.
P1.20 Select whether to print Packed date * If No Print is selected, Packed Date in P1.19 is
P1.21 Packed Date (days after actual packed date) skipped.
* If No Print is selected, Key-in selection in P1.21
P1.22 Select whether to print Packed time
Packed time in P1.22 are skipped.
P1.23 Select to print Key-In data or actual time * If P1.21 select CLOCK TIME, Key in selection in
P1.24 Packed Time (if key-In is selected) P1.22 is skipped.
P1.25 Cost price
Unit Symbol (PCS / FOR / kg / lb / g / NO
P1.27
SYMBOL)
P1.28 Quantity
P1.29 Type of Volume Discount * Depends on SPEC: 100 SETTING.
st
P1.30 The 1 target of volume discount
P1.31 The discount value for the 1st target * If No Volume discount is selected, the parameters in
P1.32 The 2nd target of volume discount P1.27 ~ P1.36 are skipped.
P1.33 The discount value for the 2nd target
P1.34 Print type of Discount price (Mark Down) *Entering by Number keys (0~3)
87 / 194
SM101+ Service
Manual
88 / 194
SM101+ Service
Manual
89 / 194
SM101+ Service
Manual
If the selected 1st or 2nd label format does not have print area for the PLU items, the
item will be skipped automatically or not printed on label.
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Enter PLU programming mode.
[*] S1.0 PLU 0 NO SET
$/kg window displays PLU number.
[1][0][0] S1.0 PLU 100 NO SET Enter new PLU Number (Ex. 100) you want.
Enter PLU programming.
[*] S1.1 PLU 0.00 PR-KG
Enter unit price.(Ex.5.80$/kg)
Select Label format for 1st Label by press [<<]
[5][8][0][*] S1.2 PLU DFT 0 LAB FR1 or [>>] key.
(T1~T12,S,A,B,C,F1~F8 is available)
Set the Label format (Ex.T6) by press [6]
[<<] or [>>] S1.2 PLU T6 6 LAB FR1
or[>>] key.
Select Label format for 2nd Label by press [<<]
[*] S1.3 PLU NO 0 LAB FR2 or [>>]key.
(F1~F8 only)
[<<] or [>>]
S1.4 C01.01 S1 A 100 Enter commodity name.(Ex. “SLICE”)
[*]
[S][L][I][C][E]
S1.4 C02.01 S1 A 100 Enter the 2nd line of commodity name.
[*]
Select the type of BARCODE by press [X] or
[*] S1.5 PLU EAN BARCODE
[>>].(EAN or ITF)
Select barcode format by press [<<] or [>>]
[*] S1.6 PLU DFLT BARCODE
key.(Ex.2f5c4i4wD)
Set flag data.(Ex.29)
The Default Flag Data can be set at SPEC 3 ~
[<<] or [>>]
S1.7 PLU 20 FLAG 6 and the Flag data consists of one or two
[*]
digits, which depends on the selected Barcode
type.
[2][9] S1.8 PLU 00000 IT CODE Enter item code.(Ex.10010)
90 / 194
SM101+ Service
Manual
[*]
91 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
[1][0][0][1][0]
S1.9 PLU 00000 EX CODE No appended item code of PLU 100.
[*]
ADD Select EAN ADD-ON or EAN ADD-OFF.(Ex.
[*] S1.10 PLU EAN
OFF EAN ADD-OFF)
Set the Main Group number.(default MG 997)
[*] S1.12 PLU 997 MG NO Enter Main Group No.(Ex.111)
Link PLU 100 to Main Group 111.
Press [<<] or [>>] key to change whether print
[1][1][1]
S1.13 PLU NPRINT SELL DT sell-by-date.
[*]
(Ex. Print sell by date)
[<<] or [>>] Set sell-by-date.(Ex.3 days)
S1.14 PLU 0 SELL DT
[*] 3 digits can be set.(0~999)
Press [<<] or [>>] key to change whether print
[3]
S1.15 PLU NPRINT SELL TM sell-by-time.
[*]
(Ex. No print sell by time)
Press [<<] or [>>] key to change whether print
[*] S1.18 PLU NPRINT USED DT used by date.
(Ex. No print used by date)
Set used-by-date, Setting way of used-by-date, used-by-time are
… … … …
used-by-time same as setting sell-by-date and sell-by-time.
Press [<<] or [>>] key to change whether print
[*] S1.20 PLU NPRINT PACK DT
packed date.
If necessarily, packed date can set the day after
[<<] or [>>]
S1.21 PLU 0 PACK DT present date.
[*]
(Ex. 1 day after present day)
Press [<<] or [>>] key to change whether print
[1][*] S1.22 PLU NPRINT PACK TM
packed time.
[<<] or [>>] Press [<<] or [>>] key to change key-in time
S1.23 PLU TIME PRESENT
[*] or present time.
[<<] or [>>] Set the packed time.
S1.24 PLU 0000 PACK TM
[*] (Ex. 18:00)
[1][8][0][0]
S1.25 PLU 0.00 COST
[*]
[*] S1.26 PLU 0.000 TARE Enter Preset Tare of PLU 10.(Ex.0.100kg)
92 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
6 kinds discount type can be selected by press
[1][0][0]
S1.29 PLU NO DISCONT [<<] or [>>] key.
[*]
(Ex. UNIT PRICE discount)
[<<] or [>>]
S1.30 PLU 0.000 1ST LMT Set 1st limit weight is 0.1kg.(Ex.0.100kg)
[*]
[1][0][0]
S1.31 PLU 0.00 1ST AMT Set 1st amount of discount is $0.30.
[*]
[3][0]
S1.32 PLU 99.999 2ND LMT Set 2nd limit weight is 1.000kg.
[*]
[1][0][0][0]
S1.33 PLU 0.00 2ND AMT Set 2nd amount of discount is $0.50.
[*]
Change selection by [<<] or [>>]:
[5][0] MARK
S1.34 PLU NO No mark down/Unit price mark down
[*] DOWN
/Total price mark down/all mark down
[1][0][0][1][0][4]
S1.36 PLU 0000 ST TIME Set discount start time.(Ex. 09:00, HH-MM)
[*]
[0][9][0][0] 00000
S1.37 PLU ED DATE Set discount end date.(Ex.11-01-04)
[*] 0
[1][1][0][1][0][4]
S1.38 PLU 0000 ED TIME Set discount end time.(Ex. 09:00)
[*]
93 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
After finish setting, save it.
[PLU] S1 → PLU ITEM
Back to S mode.
Note1: Press [*] key to next parameter or [] key to previous parameter.
Note2: The letter before "A" in Total Price display shows the letter font size of the
commodity name, and the number after "A" in Total Price display shows the
number of letters can be programmed for commodity name.
Note3: The 2 digits after "C" in Weight display shows the line of the commodity name,
and the next 2 digits in Weight display shows the position of the cursor.
Note4: The PLU No.1 to No.999999 are available for PLU programming.
Note5: The programmed PLU commodity name are printed on the label or receipt.
Note6: Max.100 letters for commodity name per file are available.
Note7: Each PLU No. must be linked to the exiting Main Group No..
DISPLAY
OPERATION REMARK
PT kg $/kg $
94 / 194
SM101+ Service
Manual
PT kg $/kg $
Set the Label format (Ex.T6) by
[<<] or [>>] S1.2 PLU T6 6 LAB FR1
press [6] or[>>] key.
Select Label format for 2nd Label
[*] S1.3 PLU NO 0 LAB FR2 by press [<<] or [>>]key.
(F1~F8 only)
[<<] or [>>] Enter commodity name.(Ex.
S1.4 C01.01 S1 A 100
[*] “CAKE”)
[C][A][K][E] Enter the 2nd line of comm95ddity
S1.4 C02.01 S1 A 100
[*] name.
Select the type of BARCODE by
[*] S1.5 PLU EAN BARCODE
press [X] or [>>].(EAN or ITF)
Select barcode format by press
[*] S1.6 PLU DFLT BARCODE
[<<] or [>>] key.(Ex.2f5c4i4wD)
Set flag data.(Ex.29)
The Default Flag Data can be set
[<<] or [>>] at SPEC 3 ~ 6 and the Flag data
S1.7 PLU 20 FLAG
[*] consists of one or two digits,
which depends on the selected
Barcode type.
[2][9]
S1.8 PLU 00000 IT CODE Enter item code.(Ex.20020)
[*]
[2][0][0][2][0] No appended item code of PLU
S1.9 PLU 00000 EX CODE
[*] 100.
Select EAN ADD-ON or EAN
[*] S1.10 PLU EAN ADD OFF
ADD-OFF.(Ex. EAN ADD-OFF)
Set the Main Group number.
(default MG 997)
[*] S1.12 PLU 997 MG NO Enter Main Group No.(Ex.222)
Link PLU 200 to Main Group
222.
Press [<<] or [>>] key to change
[2][2][2]
S1.13 PLU NPRINT SELL DT whether print sell-by-date.
[*]
(Ex. Print sell by date)
[<<] or [>>] Set sell-by-date.(Ex.3 days)
S1.14 PLU 0 SELL DT
[*] 3 digits can be set.(0~999)
95 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
Press [<<] or [>>] key to change
[3]
S1.15 PLU NPRINT SELL TM whether print sell-by-time.
[*]
(Ex. No print sell by time)
Press [<<] or [>>] key to change
[*] S1.18 PLU NPRINT USED DT
whether print used by date.
Setting way of used-by-date,
Set used-by-date,
… … … … used-by-time are same as setting
used-by-time
sell-by-date and sell-by-time.
Press [<<] or [>>] key to change
[*] S1.20 PLU NPRINT PACK DT
whether print packed date.
If necessarily, packed date can set
[<<] or [>>]
S1.21 PLU 0 PACK DT the day after present date.
[*]
(Ex. 1 day after present day)
Press [<<] or [>>] key to change
[1][*] S1.22 PLU NPRINT PACK TM
whether print packed time.
[<<] or [>>] Press [<<] or [>>] key to change
S1.23 PLU TIME PRESENT
[*] key-in time or present time.
[<<] or [>>] Set the packed time.
S1.24 PLU 0000 PACK TM
[*] (Ex. 18:00)
[1][8][0][0]
S1.25 PLU 0.00 COST
[*]
Press [<<] or [>>] to select unit
[*] S1.27 PLU PCS USYMBOL symbol.
Selection: PCS/FOR/kg/lb/g/NO
[<<] or [>>] 4 digits can be set.(0~9999).
S1.28 PLU 0 QTY
[*] (Ex. 10 pcs/PLU)
6 kinds discount type can be
[1][0] selected by press [<<] or [>>]
S1.29 PLU NO DISCONT
[*] key.
(Ex. UNIT PRICE discount)
Change selection by [<<] or [>>]:
No mark down/Unit price mark
[<<] or [>>]
S1.34 PLU NO MARK DOWN down
[*]
/Total price mark down/all mark
down
96 / 194
SM101+ Service
Manual
[<<] or [>>] Set discount start day.(Ex.10-01-
S1.35 PLU 000000 ST DATE
[*] 04, MM-DD-YY)
97 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
[1][0][0][1][0][4] Set discount start time.(Ex. 09:00,
S1.36 PLU 0000 ST TIME
[*] HH-MM)
[1][1][0][1][0][4]
S1.38 PLU 0000 ED TIME Set discount end time.(Ex. 09:00)
[*]
Note1: Press [*] key to next parameter or [] key to previous parameter.
Note2: The letter before "A" in Total Price display shows the letter font size of the
commodity name, and the number after "A" in Total Price display shows the
number of letters can be programmed for commodity name.
Note3: The 2 digits after "C" in Weight display shows the line of the commodity name,
and the next 2 digits in Weight display shows the position of the cursor.
Note4: The PLU No.1 to No.999999 are available for PLU programming.
Note5: The programmed PLU commodity name are printed on the label or receipt.
98 / 194
SM101+ Service
Manual
Note6: Max.100 letters for commodity name per file are available.
Note7: Each PLU No. must be linked to the exiting Main Group No..
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Enter PLU programming mode.
[*] S1.0 PLU 0 NO SET
$/kg window displays PLU number.
[1][2][4] S1.1 PLU 124 NO SET Select PLU 124,enter PLU programming.
[X] S1.1 PLU 0 COPY Press [X] key to enter PLU copy function.
[1][0][0]
S1.1 PLU 5.80 PR-KG Copy PLU 100 data to PLU 124.
[*]
[4][8][0]
S1.2 PLU T6 6 LAB FR1 Unit price of PLU 124 is 4.80$/kg.
[*]
[*] S1.3 PLU NO 0 LAB FR2 The 1st Label format is T6.
[*] S1.4 C01.01 SLICE S1 A 95 Commodity Name of PLU 124 is “SLICE”.
Press [*] key 5
S1.8 PLU 10100 IT CODE Item code of PLU 124 is 10124.
times
[1][0][1][2][4] S1.8 PLU 10124 IT CODE
[*] S1.9 PLU 00000 EX CODE
[PLU] S1 → PLU FILE Store the PLU 124 file, back to S mode.
99 / 194
SM101+ Service
Manual
Shop manager can select a discount type from 5 types of volume discount. The
formulas of 5 discount type are shown in the following table.
Formula of Discount price
100 / 194
SM101+ Service
Manual
Unit Price Discount (1) Unit Price = Original Unit Price - Original Unit Price = $ 10.00
Unit Price discount amount.
To select Formula (1) Unit Price discount amount = $2.00
or Formula (2) can be (2) Unit Price = Unit Price discount
decided by SPEC 124 amount. (1) Unit Price = $10.00 - $2.00 = $8.00
Setting.
(2) Unit Price = $2.00
Unit Price % Discount Unit Price = Original Unit Price x Original Unit Price = $ 10.00
(100% - % Discount)
% Discount = 20%
Total Price Discount Total Price = Original Price - Price Original Total Price = $10.00
Discount Amount
Price Discount Amount = $2.00
Total Price % Discount Total Price = Original Total Price x Original Total Price = $10.00
(100% - % Discount)
% Discount = 20%
Fixed Price Discount Total Price = Fixed Price Amount Original Total Price = $10.00
Mark Down Print function is used to print the discount price as well as the original
price with double lines crossed when item is discounted. Mark Down Print function
101 / 194
SM101+ Service
Manual
can be selected from the following 4 types, No Mark down / Unit Price Mark down/
Price Mark down / Unit Price & Price Mark down.
Note 1: Since discount unit price cannot be calculated if Total Price discount is used,
it is not able to use Unit Price Mark Down function, when using Total Price discount
and Free item discount.
102 / 194
SM101+ Service
Manual
3.8.1 PLU Assignment
PLU Number can be assigned to a preset key to call up PLU data by pressing the
assigned preset key on Registration Mode.
103 / 194
SM101+ Service
Manual
status.
Select PRICE DISCOUNT
[X][X] S4.0 FN AS 2 -PRICE
function
PRICE DISCOUNT function had
[PRESET 25] S4.2 FN AS 0 CLEAR been assigned to Preset Key
number 25.
[◇][C] S4 → KEY ASSIGNMENT Back to S mode.
At Programming Mode, select Shop Name programming mode and then enter new
Shop Name number (Ex. 1) programming mode.
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Shop name File mode is MENU 5
[5] or [︾] four times S5 → SHOP NAME FILE
in S mode.
Enter Shop Name File
[*] S5.0 SHOP 0 NO SET
programming mode.
[1][*] S5.1 S01.01 S1 A 100 Enter shop name code.(Ex.No.1)
Press [SIZE] key to change font
[SIZE][D][I][G][I] size of the shop name.
S5.1 S01.10 SHOP S2 A 76
[SP][S][H][O][P] Enter the shop name .(Ex. “DIGI
SHOP”)
Program 2nd line of this shop
[*] S5.1 S02.01 S1 A 100
name.
Enter shop name for the 2nd line.
[T][E][L][:]…… S5.1 S02.13 S1 A 88
(Ex. “TEL:57234888”)
Store Shop Name File 1,Back to S
[PLU] S5 → SHOP NAME FILE
mode.
105 / 194
SM101+ Service
Manual
Shop name File mode is MENU 5
[5] or [︾] four times S5 → SHOP NAME FILE
in S mode.
Enter Shop Name File
[*] S5.0 SHOP 0 NO SET
programming mode.
[1] S5.0 SHOP 1 NO SET Enter shop name file 1.(Ex. No.1)
Enter deleting mode.
[-] S5.0 SHOP DEL ? Y-C N-T
[C] for Yes, [T] for No.
Delete Shop Name File 1,back to
[C] S5 → SHOP NAME FILE
S mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Shop Name File can not be deleted.
106 / 194
SM101+ Service
Manual
107 / 194
SM101+ Service
Manual
[*] S6.1 A02.01 S1 A 100 Program 2nd line of this advertisement file.
Store Advertisement File 1,back to S
[PLU] S6 → ADVER MESSAGE
mode.
Note1: Max.2 line per file are available, max.100 letters per line are available. (letters
per line depends on font size)
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Select advertisement file
[6] or [︾] five times S6 → ADVER MESSAGE
programming mode.
Enter advertisement File
[*] S6.0 ADVER 0 NO SET
programming mode.
Enter advertisement File 1.(Ex.
[1] S6.0 ADVER 1 NO SET
No.1)
Enter deleting mode.
[-] S6.0 ADVER DEL ? Y-C N-T
[C] for Yes, [T] for No.
Delete advertisement File 1,back to
[C] S6 → ADVER MESSAGE
S mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Advertisement File can not be deleted
108 / 194
SM101+ Service
Manual
3.11.1 Program Vender File
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Select Vender file
[7] or [︾] six times S7 → VENDER FILE
programming mode.
Enter Vender File
[*] S7.0 CLERK 0 NO SET
programming mode.
Select vender key.(Ex. V1)
[1][*] S7.1 CLERK 1 NAME 0 Program operator name for
Vender 1.
Enter operator name for V1.
[M][I][K][E] S7.1 CLERK MIKE NAME 4
(Ex. “MIKE”)
Store Vender File V1,back to
[PLU] S7 → VENDER FILE
S mode.
109 / 194
SM101+ Service
Manual
Store Date and Time, back to
S mode.
110 / 194
SM101+ Service
Manual
3.13 Special Message File
Special Message can be used as a description on the label such as receipt, which can
be assigned in each PLU. Since standard format does not have a print area set for
Special Message, Special Message cannot be printed when using these formats. To
print Special Message on the label, it is required to use a Free Format with a Special
Message print area programmed. Maximum 16 special messages can be programmed
with each up to 8 programmable lines. Number of line is depends on the size of the
print area or Character Size entry. The default Special Number print on Receipt can be
set at SPEC 112 and printing position can be set at SPEC 125.
Note: If SPEC 43 set to RECEIPT, maximum 8 lines can be programmable for each
Special Message Number and without select a required Free Format.
111 / 194
SM101+ Service
Manual
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Special Message File can not be deleted.
Note: Maximum 39 lines can be programmed for each Master Ingredient data when
SPEC 43 set to 0.
112 / 194
SM101+ Service
Manual
3.14.1 Program Ingredient File
At Programming Mode, select Ingredient programming mode and then enter new
Ingredient number (Ex. 1) programming mode. *For edit, enter existing Ingredient number.
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
[10] or [ ︾ ] nine Select Ingredient file
S10 → INGR FILE
times programming mode.
Enter Ingredient File
[*] S10.0 INGR 0 NO SET
programming mode.
Enter the Ingredient File No.1.
[1][*] S10.1 G01.01 S1 A 100
(Ex.No.1)
Enter the Ingredient File as the
same procedures as Commodity
[S][U][G][A][R] S10.1 G01.06 SUGAR S1 A 100
Name Entry.
(Ex. “SUGAR”)
Press [SIZE] key to change font
[SIZE] S10.1 G01.06 SUGAR S2 A 95
size of the Ingredient File.
Program 2nd line of this
[*] S10.1 G02.01 S1 A 100
Ingredient File.
[F][L][O][U][R] S10.1 G02.06 FLOUR S1 A95
Store Ingredient File 1,back to S
[PLU] S10 → INGR FILE
mode.
113 / 194
SM101+ Service
Manual
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Ingredients File can not be deleted.
114 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
Select Text file programming
[11] or [︾] ten times S11 → TEXT FILE
mode.
Enter Text File programming
[*] S11.0 TEXT 0 NO SET
mode.
Enter the Text File No.1.
[1][*] S11.1 T01.01 S1 A 100
(Ex.No.1)
Enter the Text File as the same
[P][A][C][K][A][G] procedures as Commodity Name
S11.1 T01.08 CKAGE S1 A 93
[E] Entry.
(Ex. “PACKAGE”)
Press [SIZE] key to change font
[SIZE] S11.1 T01.08 CKAGE S2 A 78
size of the Ingredient File.
Change font size to S5.
[SIZE]…[SIZE] S11.1 T01.08 CKAGE S5 A 53
(S1~S5; M1~M5; L1~L5)
Program 2nd line of this
[*] S11.1 T02.01 S1 A 56
Ingredient File.
[D][A][T][E] S11.1 T02.05 DATE S1 A 52
Store Text File 1,back to S
[PLU] S11 → TEXT FILE
mode.
115 / 194
SM101+ Service
Manual
[C] for Yes, [T] for No.
Delete Text File 1,back to S
[C] S11 → TEXT FILE
mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Text File can not be deleted.
Up to 99 Free Formats can be stored in the memory, apart from the other 16
standard formats.
Standard format can be used as a basic format for creating a new format.
116 / 194
SM101+ Service
Manual
One Item label or one Total label is available for each Free Format number
(F1~F99).
4 Print Angles can be set for all item data: 0, 90, 180 and 270 degrees.
117 / 194
SM101+ Service
Manual
The print position of each item is determined by setting the interval from "0" point
(X=0, Y=0) to the base position of the programmed item. X and Y values need to be
entered by "mm".
Print Area
The item data cannot be printed at the bottom 10 mm of labels. Pre-print data such as
shop name or logo data is programmed at the bottom 10mm. Also the item data
should not be printed within 1mm from the left edge or the right edge of the label as
the following drawing shows.
118 / 194
SM101+ Service
Manual
119 / 194
SM101+ Service
Manual
Print Position
The printing position of each item data is decided by setting the distance from 0 point
(X=0, Y=0) to the base position (X value, Y value).
Print Angle
Print angle of each Print Item can be selected from 4 different angles, 0 degree, 90
degree, 180 degree, and 270 degree. A whole format base or each Item Data-base
may set print angle. According to the selected print angle, the status of print position
differs as the following samples.
120 / 194
SM101+ Service
Manual
121 / 194
SM101+ Service
Manual
122 / 194
SM101+ Service
Manual
Ty Ty
Item Data Display Item Data Display
pe pe
47 ~ 56.IMAGE 1 ~ IMAGE 10 2 IMG?? 90. Reserved
57. AVERAGE PRICE 1
Remarks: No.82 for Item Label is the test print mode for checking the
programmed print format.
Note: When SPEC 158 set to "ENABLE" the Screen of Item no.2 will change to
"DISCOUNT PRICE" & item Number 3 change to "DISCOUNT UNIT
PRICE", and Item Number of 45 & 46 will appears.
123 / 194
SM101+ Service
Manual
124 / 194
SM101+ Service
Manual
(0,90,180,270 degree)
Label angle is turned 90
[*] S12.4 LABEL ITEM LABEL
degree.
Select label type.
[<<] or [>>] S12.4 LABEL TOTAL LABEL
(Item Label; Total Label)
Enter item setting.
[*] S12.5 PLUno ← 1 F ITEM Refer to Base Type 1 to 4
setting.
Base Type 1:
Item data in Data Base Type1 are Numeric data or Fixed data. The print position of
item data can be programmed by setting X / Y value, Print angle and Character size.
Item Label: PLU No., Price, Unit Price, Weight, Quantity, Packed date, Packed
Time, Quantity Symbol, Sell by date, Sell by time, Discount Price, Used by date,
MG No., Dept. No., Scale No., Tare Weight, Clerk No., and Text data.
Total Label: PLU No., Packed date, Total Weight, Total quantity, Quantity symbol,
Total Price, Packed time, Letter of TOTAL, Clerk No., and Text data.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Continued from the procedure Basic Setting: (width, height, angle and label type)
S12.5 PLUno ← 1 F ITEM Item setting: PLU No.
[*] S12.5 PLUno 0 X MM Enter X value.(Ex.1mm)
[1][*] S12.5 PLUno 0 Y MM Enter Y value.(Ex.1mm)
[1][*] S12.5 PLUno 0 DG ANGLE Select print angle.(Ex.90 degree)
[>>][*] S12.5 PLUno 0 STATUS Enter print status.(Ex. All item print)
[7][*] S12.5 PLUno S1 CHAR SIZE Select the character size.(Ex. S5)
[<<] or [>>] key can change the
[>>] four times S12.5 PLUno S5 CHAR SIZE selection of the character size.
(S1~S5; M1~M5; L1~L5)
[*] S12.5 PLUno ← 1 F ITEM Enter next item setting.
Base Type 2
Item data in Base Type 2 are Alpha-numeric data. The print position of item data
can be programmed by setting the max. print area , X / Y value, width of print area
from X value, height of print area from Y value and print angle.
Item Label : Commodity Name, Shop Name, Logo, Ingredient, and Special Message.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Continued from the procedure Basic Setting: (width, height, angle and label type)
S12.5 SHOPN ← 13 F ITEM Item setting: Shop name.
[*] S12.5 SHOPN 0 X MM Enter X value.(Ex.10mm)
[1][0][*] S12.5 SHOPN 0 Y MM Enter Y value.(Ex.1mm)
[1][*] S12.5 SHOPN 0 DG ANGLE Select print angle.(Ex.180 degree)
Enter width value.
[>>][>>][*] S12.5 SHOPN 0 WT MM The width of shop name printing area is
20mm.(Ex. 20mm)
Enter height value.
[2][0][*] S12.5 SHOPN 0 HT MM The height of shop name printing area is
15mm.(Ex. 15mm)
[1][5][*] S12.5 SHOPN 0 STATUS Enter print status.(Ex. All item print)
The status of shop name printing area is
[7] S12.5 SHOPN 7 STATUS
all item printing.
[*] S12.5 SHOPN ← 13 F ITEM Enter next item setting.
Base Type 3
126 / 194
SM101+ Service
Manual
Item data in Data Base 3 is Barcode data. The print position of bar-code data can be
programmed by setting X / Y value, width of Barcode from X value, height of
Barcode from Y value and print angle.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Continued from the procedure Basic Setting: (width, height, angle and label type)
S12.5 BARCD ← 12 F ITEM Item setting: Barcode.
[*] S12.5 BARCD 0 X MM Enter X value.(Ex.5mm)
[5][*] S12.5 BARCD 0 Y MM Enter Y value.(Ex.20mm)
[2][0][*] S12.5 BARCD 0 DG ANGLE Select print angle.(Ex.90 degree)
Enter height value.
[>>][*] S12.5 BARCD 0 HT MM The height of shop name printing area is
25mm.(Ex. 25mm)
[2][5][*] S12.5 BARCD 0 STATUS Enter print status.(Ex. All item print)
The status of BARCODE printing area is
[7] S12.5 BARCD 7 STATUS
all item printing.
[*] S12.5 BARCD ← 12 F ITEM Enter next item setting.
Base Type 4
Item data in Data Base 4 is Frame data. The print position of Frame data may be
programmed by setting X value, Y value, X1 value, Y1 value [the opposite point
against the point (X,Y) on a diagonal line], and line weight.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Continued from the procedure Basic Setting: (width, height, angle and label type)
S12.5 FRM 1 ← 22 F ITEM Item setting: Frame 1.
[*] S12.5 FRM 1 0 X MM Enter X value.(Ex.10mm)
[1][0][*] S12.5 FRM 1 0 Y MM Enter Y value.(Ex.1mm)
Enter X1 value.
[1][*] S12.5 FRM 1 0 X1 MM The X1 of frame 1 printing area is
20mm.(Ex. 20mm)
Enter Y1 value.
[2][0][*] S12.5 FRM1 0 Y1 MM The Y1 of frame 1 printing area is
15mm.(Ex. 15mm)
127 / 194
SM101+ Service
Manual
[1][5][*] S12.5 FRM 1 0 STATUS Enter print status.(Ex. All item print)
Enter line weight.
[7][*] S12.5 FRM 1 0 T MM The line weight of frame 1 printing area
is 2mm.(Ex. 2mm)
[2][*] S12.5 FRM 1 ← 22 F ITEM Enter next item setting.
128 / 194
SM101+ Service
Manual
Note1: Another way to select the existing label format to copy by press [<<] Key or
[>>] Key.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter Free Format
S12.0 FREE 0 1-99
programming mode.
Enter free format file number
[1] S12.0 FREE 1 1-99
1.
Enter delete mode.
[-] S12.0 FREE DEL ? Y-C N-T
[C] for Yes,[T] for No.
Delete free format file 1, back
[C] S12.0 → FREE FORMAT
to S mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Free Format File can not be deleted.
129 / 194
SM101+ Service
Manual
130 / 194
SM101+ Service
Manual
Following is the example on how to customize standard format T8 to your needs. E.g.
Add an ingredient text and remove the PLU # from the standard Item Label Format
DISPLAY
OPERATION REMARK
PT kg $/kg $
S12 → FREE FORMAT At Free Format program mode
Enter Free Format setting
[*] S12.0 FREE 0 1-99 programming mode.
Select Free Format File Number.
Enter the Free Format File No.1.
[8] S12.0 FREE 8 1-99
(Ex.No.8)
Press [X] key to enter free
[X] S12.0 FREE NO 0 COPY
format copy function.
Press [8] or [<<] and [>>] to
[8] or
S12.0 FREE T8 8 COPY select the existing label format
[<<] and [>>]
you want to be copy.(Ex. T8)
131 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter TTL Height setting mode,
change the height from 21 mm
[*][*][1][5] S12.5 COMM 15 HT MM
to 15 mm and go to next
selection.
132 / 194
SM101+ Service
Manual
3.17 Place File
PLACE file is used for programming a short text describing the place of production.
The number of Characters possible to enter depends on the PLACE print area size
and the character size used. Place will be printed in the free room of Commodity
Name print area if selected label format without Place print area. Maximum 99 places
(Place number 1 ~ 99) can be programmed, each with 1 line.
133 / 194
SM101+ Service
Manual
mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Place File can not be deleted.
Logo data can be programmed up to 4 logos. When using 4 logos for label, assign the
LOGO KEY to preset key in advance. A logo data is formed by a pattern of dots
(128 horizontal dots and 64 vertical dots.) However, since the Label logo data is
printed within the limits, which are programmed in label formats, program the logo
data within the limits of print area on the format.
Note: All standard formats have 37 dots x 30 dots for logo print area.
2) When programming Label Logo, draw the limit of the Logo print area.
134 / 194
SM101+ Service
Manual
3) Draw the desired logo design in the section paper by filling the section with dot.
(The dots are necessary to seize the image of the actual logo before
programming.)
135 / 194
SM101+ Service
Manual
2) When the programming status reached to the last dot (128 horizontal dots), or [*]
key is depress, the programming status moves to the first left section on the next
upper line automatically.
DISPLAY
OPERATION REMARK
PT kg $/kg $
S1 → PLU FILE Enter S mode.
136 / 194
SM101+ Service
Manual
NO Enter Logo File programming mode.
[1][7][*] S17.0 LOGO 0
SET Enter Logo File number.(Ex. 1)
[1][*] S17.1 LOGO 0 X-POS Enter X position.(Ex. 7 dots)
[7][*] S17.2 LOGO 0 Y-POS Enter Y position.(Ex. 1dots)
Set Fill or Clear dots you want and the save
[1][*] S17.3 LOGO 000000 007-01 the setting and go to next upper line (Y 02).
(Ex.11101110001)
[1][1]……[0][1][*] S17.3 LOGO 000000 001-02 Press [>>] key to move the cursor to next dot.
If necessary to change the position of the
Press[>>]key 6 times S17.3 LOGO 000000 007-02 cursor been set, the following procedure is
required.
Change the Horizontal start position (Ex. 5
[-][-] S17.3 LOGO 7 X-POS
dots).
Change the Vertical start position (Ex. NO
[5][*] S17.3 LOGO 2 Y-POS
CHANGE).
[*] S17.3 LOGO 000000 005-02 After complete program Logo data, save it.
[PLU] S17 → LOGO FILE Store the Logo 1 data, back to S mode.
Note1: If you want to exit without saving, press [◇] key follow by [C] key.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter Logo File programming
S17.0 LOGO 0 NO SET
mode.
[1] S17.0 LOGO 1 NO SET Enter Logo File number 1.
Enter delete mode.
[-] S17.0 LOGO DEL ? Y-C N-T
[C] for Yes,[T] for No.
Delete Logo File 1, back to S
[C] S17 → LOGO FILE
mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Logo File can not be deleted.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Tax File can not be deleted.
139 / 194
SM101+ Service
Manual
3.21.2 Delete Scroll Message File
When the Scroll message number is linked to Scroll Sequence, it can’t be deleted.
At Scrolling Message program mode, enter existing Scroll Message Number (Ex. 1)
to be deleted.
DISPLAY
OPERATION REMARK
PT kg $/kg $
SC Enter Scrolling Message
S13.0 0 NO SET
MG programming mode.
SC Enter Scrolling Message number.
[1] S13.0 1 NO SET
MG (Ex. 1)
SC Enter delete mode.
[-] S13.0 DEL ? Y-C N-T
MG [C] for Yes,[T] for No.
Delete Scrolling Message File 1,
[C] S13 → SCROLL MESSAGE
back to S mode.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Scroll Message File can not be deleted.
140 / 194
SM101+ Service
Manual
3.22.1 Program Scroll Sequence File
At Programming Mode, select Scrolling Sequence programming mode and then enter
new Scroll Sequence number (Ex. 1) programming mode. *For edit, enter existing
Scroll Sequence Number.
DISPLAY
OPERATION REMARK
PT kg $/kg $
S1 → PLU FILE Enter S mode.
Enter Scrolling Sequence
[1][4][*] S14.0 SC SQ 0 NO SET
programming mode.
Enter Scrolling Sequence file
[1][*] S14.1 SC SQ MSG NO 000
number.(Ex. 1)
Enter existing Scrolling
[1][2][3][*] S14.2 SC SQ ATTRIB 123 000
Message Number.(Ex. 1, 2, 3)
Select Scrolling pattern for
each Scrolling Message.
[1][2][3][*] S14.2 SC SQ SPEED 123 000
(Ex. MSG#1=1, MSG#2=2 &
MSG#3=3)
Select Scrolling Rate.
(Ex.
[1][2][0] S14.2 SC SQ SPEED 123 120 MSG#1=1:NORMAL,MSG#2
=2:FAST and
MSG#3=0:SLOW)
Store the Scroll message 1
[PLU] S14 → SCROLL SEQUENC
data, back to S mode.
141 / 194
SM101+ Service
Manual
time. The Scroll Message, Scrolling Pattern and Speed will follow Scroll Sequence
Number setting.
Note1: If you want to change the Scroll Sequence number, enter new sequence
number follow by press [PLU] key.
Note1: If you want to cancel the deletion, press [T] key to exit.
Note2: Non-existing Scroll Sequence File can not be deleted.
DISPLAY
OPERATION REMARK
PT kg $/kg $
[MODE][MODE] Enter S mode.
S1 → PLU FILE
[MODE] Lamp S turns on.
143 / 194
SM101+ Service
Manual
Enter Data1 Type # (Ex.6)
[6][*] S46.3 F BAR 0 DATA 1
(0~6 only))
Enter Data1 Digit # (Ex.6)
[6][*] S46.4 F BAR 0 DIGIT
(0~9 only)
Enter Data1 Shift # (Ex.5)
[5][*] S46.5 F BAR 0 SHIFT
(0~5 only)
Enter Data2 Type # (Ex.6)
[6][*] S46.6 F BAR 0 DATA 2
(0~6 only))
Enter Data2 Digit # (Ex.6)
[6][*] S46.7 F BAR 0 DIGIT
(0~9 only)
Enter Data2 Shift # (Ex.5)
[5][*] S46.8 F BAR 0 SHIFT
(0~5 only)
[X] or
S46.9 F BAR NO MIDDLE CD Select Middle Check Digit
[<<] and [>>] [*]
[×] or
S46.1 F BAR NO LAST CD Select Last Check Digit
[<<] and [>>] [*]
[×] or
Select Barcode Type (ITF or
[<<] and [>>] S46.1 F BAR ITF BARCODE
EAN)
[PLU]
DISPLAY
OPERATION REMARK
PT kg $/kg $
[X] or [>>] [*] S1.5 PLU ITF BARCODE Select ITF Barcode
[<<] S1.6 PLU DELT BAR CODE Select Flexi-barcode
[*] or [PLU] S1.6 PLU F BAR 2 Ex. Flexi-barcode #2
144 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter Flexi Barcode
S46.0 F BAR 0 NO SET
programming mode.
Enter Flexi Barcode file
[1] S46.0 F BAR 1 NO SET
number.(Ex. 1)
Enter delete mode.
[-] S46.0 F BAR DEL ? Y-C N-T
[C] for Yes,[T] for No.
Delete Flexi Barcode Number
[C] S46 → FLEXI BARCODE
1, back to S mode.
Note: If you want to cancel the deletion, press [T] key to exit.
145 / 194
SM101+ Service
Manual
? /? ¨ ¹/¨ ¹ ? /? ¨ ¦/¨ ¦ ? /? ? /? ¨¤
/¨ ¢ ? /¨ ª
+ ? < . > , € ¨® ← →
146 / 194
SM101+ Service
Manual
Note1: Decimal digital from 32 to 255 can be entered. Each Decimal digital figures
one ASCII Character.
Note2: Different Countries can refer to the local ASCII Code List.
147 / 194
SM101+ Service
Manual
4. REGISTRATION MODE
4.1 ON/OFF
1 - ZERO 2 - NET 3 - FIX T
4 - FIX P
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4
Power on. [ON/OFF] 0000 00000 000000 0000000
1111 11111 111111 1111111
2222 22222 222222 2222222
1333 33333 333333 3333333
4444 44444 444444 4444444
5555 55555 555555 5555555
6666 66666 666666 6666666
7777 77777 777777 7777777
8888 88888 888888 8888888
9999 99999 999999 9999999
**** ***** ****** *******
. . . . . . . . . . . . . . . . . . . . . .
, , , , , , , , , , , , , , , , , , , , , ,
^^^^ ^^^^^ ^^^^^^ ^^^^^^^
148 / 194
SM101+ Service
Manual
151 / 194
SM101+ Service
Manual
0.0 0 0 0.0 0 0 0.0 0 0.0 0
Set to receipt mode. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
152 / 194
SM101+ Service
Manual
Check whether the Label Size fits the programmed one in PLUs when label is
used.
For example: Sell one pack of SMOKED SAUSAGE (Ex. PLU #: 30) and sell five
packs of SLICED BACON (Ex. PLU #: 40). (Non-weighing Item)
1 - ZERO 2 - NET 3 - FIX T 4 - FIX P 5-
MANUAL 6 - LABEL
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Smoked Sausage. [3] [0] 0.0 0 0 0.0 0 0 0.3 0 0.0 0
Press PLU key. [PLU] 2.5 0 PR-PCS
Press [*] key to print label. [*] 0.0 0 0 0.0 0 0 0.0 0 1.2 0
Enter the PLU No. of the Sliced Bacon. [4] [0] 0.0 0 0 0.0 0 0 0.4 0 0.0 0
Press PLU key. [PLU] 3.2 0 PR-PCS
Multiply. [X] QTY 1 3.2 0 3.2 0
5 packs. [5] QTY 5 3.2 0 1 6.0 0
Print out one item label. [*] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
153 / 194
SM101+ Service
Manual
For example: Enter the Price for Non-PLU item (Ex. 5.00) by numeric key.
Note: For Non-weight Item, just press [*] key to issue out a label or press [X] key to
enter multiply mode, then enter sale quantity and press [*] key to issue label.
1 - ZERO 2 - NET 3 - FIX T 4 - FIX P 5-
MANUAL 6 - LABEL
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the unit price [5] [0] [0] 0.0 0 0 0.0 0 0 5.0 0 0.0 0
Multiply. [X] QTY 1 5.00 5.00
5 packs. [5] QTY 5 5.0 0 25.0 0
Print out one item label. [*] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
For example: Sells 1.5 kg of HERB CHEESE(Ex. PLU #: 3) and 2 packs of SKIM
MILK(Ex. PLU # 302) for customer A.
154 / 194
SM101+ Service
Manual
1 - ZERO 2 - NET 3 - V1 4 - V2
5 - V3 6 - V4
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the HERB CHEESE [3][PLU] 0.0 0 0 0.0 0 0 5.0 0 0.0 0
Place the product on the platter. (1.5kg) 0.0 0 0 1.5 0 0 5.0 0 7.5 0
Register sales item to Vender1. [V1] -V1- TOTAL 1PCS 7.5 0
[C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the SKIM MILK [3][0][2][PLU] 3.0 0 PR-PCS
Enter the sell Qty (Ex. 2 packs) [X][2] QTY 2 3.0 0 6.0 0
Register sales item to Vender1. [V1] -V1- TOTAL 3PCS 13.5 0
Print out one total label. [*] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
155 / 194
SM101+ Service
Manual
4.8.3 [PRICE % DISCOUNT] Function Key in Add Mode
This function key is used to get the desirable discounted total price in Add Mode by
setting the discount % value from the original total price when issuing total label or
receipt. The formula is shown as follows
PRICE TO PAY = ORIGINAL TOTAL PRICE x (100% - DISCOUNT %
VALUE)
Note: Prior to this operation, [PRICE % DISCOUNT] Function should be assigned
to Preset Key in advance (Ex. Assign to Preset Key No.3).
1 - ZERO 2 - NET 3 - V1 4 - V2
5 - V3 6 - V4
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Beef steak. [1] [0] 0.0 0 0 0.0 0 0 0.1 0 0.0 0
Press PLU key. [PLU] 0.0 0 0 0.0 0 0 1.20 0.0 0
Place the product on the platter. (e.g. 1kg) 0.0 0 0 1.0 0 0 1.20 1.2 0
Register sales item to Vender1. [V1] -V1- TOTAL 1PCS 1.2 0
Press [P3] key. [P1] -V1- DISC RATE 0.00
Enter discount rate. (Ex.10%) [1] [0] [0] [0] -V1- DISC RATE 10.00
Confirm. [*] -V1- TOTAL 1PCS 1.08
[C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
156 / 194
SM101+ Service
Manual
4.9.1 On The Spot Correction
This function is to void the last item data of an accumulating operation, when an
operator noticed it was a mistake or a customer canceled purchase before issuing a
Receipt or Total Label. It is effective for either weighed or non-weighted item in the
last transaction.
Transaction Example Vender 1: (1) 1kg of BEEF STEAK.
But customer canceled 5kg of BEEF STEAK accumulated in the last operation.
1 - ZERO 2 - NET 3 - V1 4 - V2
5 - V3 6 - V4
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0
Place the product on the platter. (e.g. 1kg) 0.0 0 0 1.0 0 0 1.2 0 1.2 0
Register sales item to Vender1 [V1] -V1- TOTAL 1PCS 1.2 0
Remove the product from the platter. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Smoked [3] [0] [PLU] 2.5 0 PR-PCS
Sausage.
Register sales item to Vender1 [V1] -V1- TOTAL 2PCS 3.7 0
Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0
Place the product on the platter. (e.g. 5kg) 0.0 0 0 5.0 0 0 1.2 0 6.0 0
Register sales item to Vender1 [V1] -V1- TOTAL 3PCS 9.7 0
Delete the last item entry. [-] -V1- TOTAL 2PCS 3.7 0
[C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
But customer canceled One pack of Smoked Sausage in the 2nd transaction.
157 / 194
SM101+ Service
Manual
1 - ZERO 2 - NET 3 - V1 4 - V2
5 - V3 6 - V4
OPERATION KEYS PT kg Kg $/kg $ 1 2 3 4 5 6
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0
Place the product on the platter. (e.g. 1kg) 0.0 0 0 1.0 0 0 1.2 0 1.2 0
Register sales item to Vender1 [V1] -V1- TOTAL 1PCS 1.2 0
Remove the product from the platter. [C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter the PLU No. of the Smoked Sausage. [3] [0] [PLU] 2.5 0 PR-PCS
Register sales item to Vender1 [V1] -V1- TOTAL 2PCS 3.7 0
Enter the PLU No. of the Beef Sirloin. [1] [0] [PLU] 0.0 0 0 0.0 0 0 1.2 0 0.0 0
Place the product on the platter. (e.g. 5kg) 0.0 0 0 5.0 0 0 1.2 0 6.0 0
Register sales item to Vender1 [V1] -V1- TOTAL 3PCS 9.7 0
[C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Enter into Item Correction mode. [-] ITEM VOID
Select Vender1. [V1] VD 1 1PCS 1.2 0
[<<] or [>>] to search the item. [>>] VD 2 1PCS 2.5 0
Delete the selected item. [*] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Check Vender1 sale total. [V1] -V1- TOTAL 2PCS 7.2 0
[C] 0.0 0 0 0.0 0 0 0.0 0 0.0 0
158 / 194
SM101+ Service
Manual
(1) For weighing item, label is automatically issued (without pressing [*] key)
after the weight of the item gets stable. The machine keeps the PLU data
until [C] key is pressed.
(2) For non-weighing item, the next label is automatically issued (without
pressing [*] key) after a label is taken away. The machine keeps the PLU
data until [C] key is pressed.
159 / 194
SM101+ Service
Manual
Print out the first label… [*] LABEL COUNT 20
Print out the second label… *Note LABEL COUNT 19
……
Print out the last label. LABEL COUNT 1
Stand-by-status. 0.0 0 0 0.0 0 0 0.0 0 0.0 0
Note1: To cancel printing, depress C key.
For example: At Pre-pack Mode, enter the Price for Non-PLU item (Ex. 5.00) by
numeric key.
Note1: For Non-weight Item, just press [*] key to start issuing out a label and
registered to PLU # 999999.
Note2: For Weighing of Non-PLU Item will be registered to PLU # 999998.
160 / 194
SM101+ Service
Manual
PRINT LIMIT
For setting the report range, Department Number, Main Group Number or PLU
Number to start and finish is to be entered.
LOWER LIMIT: DEPARTMENT: No.1 - No.99
162 / 194
SM101+ Service
Manual
163 / 194
SM101+ Service
Manual
164 / 194
SM101+ Service
Manual
[*] X2.4 1 ST NUM Enter starting PLU Number.(Ex.3)
165 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter ending PLU Number.
[3][*] X2.4 3 ED NUM
(Ex.999996)
[9][9][9][9][9][6] Print PLU Term Read Report t
- REPORT PRINTING -
[*]
X2.4 READ PLU PERIOD Display back to X mode.
166 / 194
SM101+ Service
Manual
[︽] or [︾] or [X] X4.4 READ SALES TERM Select Sales Term Read Report.
[*] - REPORT PRINTING - Print Sales Term Read Report.
X3.4 READ DEPT TERM Display back to X mode.
167 / 194
SM101+ Service
Manual
*Even if the accumulated share exceeds 95%, the last PLUs will be included in
Rank B.
For example: Printing report order for ABC Daily/Term Read Report:
PLU NUMBER LOWER LIMIT: 1
PLU NUMBER UPPER LIMIT: 999
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter X mode X1.1 READ MG DAILY Lamp X turns on.
[︽] or [︾] or [X] X6.1 READ ABC DAILY Select ABC Daily Read Report.
[*] X6.1 1 ST NUM Enter starting PLU NO.(Ex.1)
[1][*] X6.1 2 ED NUM Enter ending PLU NO.(Ex.999)
[9][9][9][*] - REPORT PRINTING - Print ABC Daily Read Report.
X6.1 READ ABC DAILY Display back to X mode.
[︽] or [︾] or [X] X6.4 READ ABC TERM Select ABC Term Read Report.
[*] X6.4 1 ST NUM Enter starting PLU NO.(Ex.1)
[1][*] X6.4 1 ED NUM Enter ending PLU NO.(Ex.999)
[9][9][*] - REPORT PRINTING - Print ABC Term Read Report.
X6.4 READ ABC TERM Display back to X mode.
168 / 194
SM101+ Service
Manual
X7.1 READ CLERK DAILY Display back to X mode.
169 / 194
SM101+ Service
Manual
5.2.9 Tax Report
Tax report is used to print out the Tax total data such as Tax Type, Tax rate, Amount Including Tax,
Amount Excluding Tax, Tax Amount and so on by every Tax Number.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter X mode X1.1 READ MG DAILY Lamp X turns on.
[︽] or [︾] or [X] X9.4 READ TAX Select Tax Daily Read Report.
Enter starting Tax Number.
[*] X9.4 1 ST NUM
(Ex.1)
[1][*] X9.4 1 ED NUM Enter ending Tax Number.(Ex.3)
[3][*] - REPORT PRINTING - Print Tax daily Read Report.
X9.4 READ TAX Display back to X mode.
170 / 194
SM101+ Service
Manual
171 / 194
SM101+ Service
Manual
6.1.2 Traceability Reset Report
DISPLAY
OPERATION REMARK
PT kg $/kg $
Enter Z mode Z1.0 RESET SALES DAILY Lamp Z turns on.
[︽] or [︾] or [X] Z4.0 RESET TRACE REPORT Select Traceablity Report.
Enter Reset mode.
[*] RESET REPORT ? Y-C N-T
[C] for Yes,[T] for No.
[C] Z4.0 RESET TRACE REPORT Display back to Z mode.
172 / 194
SM101+ Service
Manual
7. ADJUSTMENT
7.1 Peel Sensor Voltage and Label Sensor Sensitivity
Adjustment
Label Sensor
173 / 194
SM101+ Service
Manual
LOCATION OF PEEL AND LABEL SENSOR
7.1.1 Peel Sensor Voltage
To set the peel sensor voltage if the peel sensor is not working normally in some
situations like temperature and humidity change.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Z mode.
Z1.0 RESET SALES DAILY
Lamp Z turns on.
Enter [5][1][5] while depressing
[Rezero].
[Rezero]+[5][1][5] PEEL PFD 0.5 0.0 ﹩/kg window displays label paper
peel sensor voltage, ﹩window
displays new setting value.
[T] Z1.0 RESET SALES DAILY [T] key to exit.
When the label came out three or more when feeding or printing, the sensitivity of the
sensor need to be adjusted to sense the gap between the label better. There is a
variable resistor near the sensor. Adjust it to increase or decrease the sensitivity.
Clockwise is to increase the sensitivity and anti-clockwise is to decrease the
sensitivity.
174 / 194
SM101+ Service
Manual
DISPLAY
OPERATION REMARK
PT kg $/kg $
Z mode.
Z1.0 RESET SALES DAILY
Lamp Z turns on.
Enter [5][1][6] while
depressing [Rezero].
﹩/kg window
[Rezero]+[5][1][6] GAP PFD 2.0 3.1 displays label paper
gap sensor voltage,
﹩window displays
new setting value.
[T] Z1.0 RESET SALES DAILY [T] key to exit.
175 / 194
SM100 Service
Manual
7.2 Adjustment of Printing Position
This function is used to adjust the print position on label.
DISPLAY
OPERATION REMARK
PT kg $/kg $
Z mode.
Z1.0 RESET SALES DAILY
Lamp Z turns on.
Enter [5][1][4] while depressing
[Rezero].
[Rezero]+[5][1][4] ADJ PFD 0 0
﹩/kg window display old setting,
﹩window display new setting.
To move up the point position on
[1][0] ADJ PFD 0 10 label, enter the new value by numeric
key (Ex. 10 dots).
If you want to move down the print
position, please enter the new value
[1][0][-] ADJ PFD 0 -10 by numeric key (Ex. 10dots), and
then press [] key.
176 / 220
SM101+ Service
Manual
177 / 194
SM101+ Service
Manual
7.3 Voltage CheckPoint
There are several voltage checkpoints on the PCB boards. Below are some reference
voltage points that are commonly use.
VOLTAGE POINT VOLTAGE PURPOSE
VCC 3.3 V Provide voltage for most of the IC
VTH 24 V Provide voltage mainly to the thermal head
VBB 3V Provide backup voltage for the RAM IC
HVcc 5V
The tolerance of all the voltage is about ± 5% except VTH is +2% and -5%
178 / 194
SM101+ Service
Manual
8. SOFTWARE SETTING
8.1 Software Version Upgrade
SM-101+ use flash RAM instead of EPROM for the main program storage of the scale.
Before the boot program Version 1.10, we just have one method to update the scale’s
software: PC to scale via RS232 interface.
After the boot program Version 1.10 (including V1.10), we add a new method to
update the scale’s software: update the scale by ethernet. So you can choose either
method between these two ones to update your scale.
Now we will set two parts to introduce the steps of these two updating methods.
There are also two ways to connect the PC and the scale in updating the scale by
ethernet.
179 / 194
SM101+ Service
Manual
crossing twisted cable: one end with T568A line series, another with T568B line series
normal twisted cable: two ends both with T568B line series
180 / 194
SM101+ Service
Manual
2-ethernet.
2) Display on the scale’s screen
A. If you choose 2 and the scale’s connection is correct, it will display “waiting for
connect”.
B. Then the message on the scale’s screen is “getting IP address”.
C. After this, it will display “001 scale ready update”.
D. You can’t stop it unless you press On/Off key. If you want to continue updating.
You also don’t need to press any key on the scale until MiniProgrammer begin to
run.
3) How to upload the scale by Mini Programmer?
181 / 194
SM101+ Service
Manual
182 / 194
SM101+ Service
Manual
183 / 194
SM101+ Service
Manual
Notice: The message “001 scale ready update” must be displayed on the
screen of the scale before pressing the “run” button.
184 / 194
SM101+ Service
Manual
Notice: 1.If the boot program of this version is already in the scale, you don’t need
to upload it again, skip it and upload the main program.
1. If the scale is updated from 1.xx to 2.xx,firstly you must update the
boot program of the version.
185 / 194
SM101+ Service
Manual
186 / 194
SM101+ Service
Manual
187 / 194
SM101+ Service
Manual
188 / 194
SM101+ Service
Manual
189 / 194
SM101+ Service
Manual
Notice: The message “001 scale ready update” must be displayed on the
scale before pressing the “run” button.
190 / 194
SM101+ Service
Manual
Notice: If the boot program of this version is already in the scale, you
don’t
need to upload it again, skip it and upload the main program.
191 / 194
SM101+ Service
Manual
192 / 194
SM101+ Service
Manual
193 / 194
SM101+ Service
Manual
Setup on Going
195 / 194
SM101+ Service
Manual
196 / 194
SM101+ Service
Manual
1
2
Select PLU Item from box 1 and then choose “0 - allow” or “1 - inhibit” from box 2.
When setting completed, please exit this window.
197 / 194
SM101+ Service
Manual
198 / 194
SM101+ Service
Manual
Remark: This facility is just used to modify const file. After modifying you must
use the modified const file to update the firmware of SM-101+. Details please refer
to the SM-101+ update guide.
199 / 194
SM101+ Service
Manual
9. INTERFACE
9.1 PC Interface
SM-101+ can be connect to PC through Ethernet interface and RS232C. See below for
the connection method.
Windows 98
My Computer → Control Panel → Network→TCP/IP of Ethernet card (Select
Properties)
IP address : 192.168.1.XXX ------ XXX - can be any number. But preferable 100 to
255.
Submask : 255.255.255.0
Above IP address is use as a standard address to use for SM 101+ Ethernet
communication.If whatever reason, the IP address had to be change, it may do so. But
the scale IP address had to be change at the SM 100 scale also so that they are within
the same network. Eg. If the computer IP address is 192.168.1.XXX, the SM-100+
scale IP address has to be change to 192.168.1.XXX. The last three digits of the IP
address should not be similar within the computer and scales at all time. As can see the
first three set of number of the IP address of the computer and scale must be the same.
Before setting the SPEC setting of the scale, please check below.
200 / 194
SM101+ Service
Manual
* IMPORTANT : Please take note that this is a one time setting. It cannot be change
after setting it. Please check the old address and input accordingly. As same internal
Ethernet address in a network may conflict during communication.
201 / 194
SM101+ Service
Manual
9.4 Connection Method
9.4.1 RS232C Interface with PC
202 / 194
SM101+ Service
Manual
9.4.2 Ethernet Connection (Ethernet Interface)
Straight cable is for Client / Server connection. Crossover cable is for Hub to Hub
connection. (Some models of the hub do not need crossover cable for hub to hub
connection.Please refer to the hub operation manual if in doubt)
203 / 194
SM101+ Service
Manual
PIN CONFIGURATION
204 / 194
SM101+ Service
Manual
SM-101+ uses normal phone mike plug to connect cash drawer and the scale.
205 / 194
SM101+ Service
Manual
10. MISCELLANEOUS
10.1 Flexible Barcode Setting Guide
206 / 194
SM101+ Service
Manual
207 / 194
SM101+ Service
Manual
Traceability Programming
208 / 194
SM101+ Service
Manual
209 / 194
SM101+ Service
Manual
210 / 194
SM101+ Service
Manual
211 / 194
SM101+ Service
Manual
212 / 194
SM101+ Service
Manual
PLU Programming
When you edit PLU, set “S1.64 PLU” to “TRACE ALLOW” and press [*]
Input traceability number and press [#] to save
In the end, when you call the PLU and print label, you’ll see the traceability
information on the label
213 / 194
SM101+ Service
Manual
Nutrition uses fix template to print. Totally It has 12 fix templates(No. 70 ~ No. 81).
Setting Method
1. Enter S mode
2. Enter “S19 --- PLU ITEM” and set “IMAGE” and “NUTRI” to “PROGRAM”
3. Enter “S12 --- FREE FORMAT”
4. Enter “S12.5 IMG 1 ← 47 F ITEM” to “S12.5 IMG 10 ← 56 F ITEM” to set the
print
area of Nutrition. (In each label format, totally you can print 10 images)
5. Enter “S1 --- PLU FILE” to create PLU.
6. Enter “S1.50 PLU 0 IMAGE 1” to choose the template number for IMAGE 1
(From No. 70~ No. 81).
…
7. Enter “S1.59 PLU 0 IMAGE 10” to choose the template number for IMAGE 10
(From No. 70~ NO. 81).
8. Set “S1.81 PLU PRINT NUTRI” to set nutrition print status to “Print”.
9. Enter from S1.82 to S1.10 to input nutrition contents.
10. For extra details on the Nutrition Fact, Enter S11: TXT form to edit by hands.
11. Enter “S12 --- FREE FORMAT” to set up the TXT position.
12. Press [PLU] key to save.
214 / 194
SM101+ Service
Manual
10.4.2 Spec
50 Setting of Client / Server
0 Client 2 Backup Server
1 Server / Workstation
61 Floating Clerk
0 Inhibit 1 Allow
215 / 194
SM101+ Service
Manual
10.4.3 Setting
1) Assure network settings of all scale are effective. IP-address of all scales must be
set in same subnet and different from each scale.
2) SPEC141
10.4.5 Effect
When the functions are effective, the operation on SERVER is still same as stand-
alone scale. CLIENT will connect to SERVER automatically after power on. CLIENT
becomes into online status when connection is succeeded. And CLIENT will display
“SERVER OFF-LINE” before finishing connection. CLIENT could turn into offline
status via [C] key while it’s displaying “SERVER OFF-LINE”.
216 / 194
SM101+ Service
Manual
Effect on CLIENT
217 / 194
SM101+ Service
Manual
218 / 194
SM101+ Service
Manual
219 / 194
SM101+ Service
Manual
220 / 194