IC 902

electronic thermostat with single output

THE USER INTERFACE PROGRAMMING MENU


INSTALLATION
The user has a display and four keys for To enter the “Programming” menu, press The instrument is designed for flush panel
controlling status and programming of the the “SET” key for more than 5 seconds. mounting. Insert the unit through a
instrument. If specified, the access PASSWORD will be 71x29 mm panel cut-out and affix with the
requested, (parameter “PA1”), and the U-bracket supplied.
KEYS AND MENUS label of the first folder will follow. Select a location which will not be subject
To scroll through the other folders, use to high humidity or condensation and
UP key Scrolls through the menu items the “UP” and “DOWN” keys. allow some ventilation to provide cooling
Increases the values
To enter the folder, press “SET”. The label to the instrument.
of the first visible parameter appears.
DOWN key Scrolls through the menu items
Decreases the values
To scroll through the other parameters, ELECTRICAL
use the “UP” and “DOWN” keys. To change
FNC key ESC function (exit) the parameter, press and release “SET” CONNECTIONS
fnc then set the desired value with the “UP”
and “DOWN” keys, and confirm with the Attention! Never work on electrical con-
SET key Accesses the setpoint
set Accesses the menus “SET” key, to move to the next parameter. nections when the machine is switched on.
Confirms the commands The instrument is equipped with screw ter-
COPY CARD minal boards for connection of electrical
The instrument has two main menus: the The Copy Card is an accessory that con- cables with a diameter of 2.5 mm2 (one
“Machine Status” and “Programming” nected to the serial door TTL permits both conductor only per terminal for power
menu. fast programming of instrument’s parame- connections). For the capacity of the ter-
ters (download), and the possibility to save minals, see the label on the instrument.
ACCESSING AND USING MENUS the instrument’s parameters (upload) in Relay outputs are voltage free. Do not
The instrument is programmed by menus. order to use them to ri-program other exceed the maximum permissible current
To access a menu, press and quickly equivalent instruments. To do this opera- – in case of higher loads, use a contactor
release the “SET” key (“Machine status” tion enter the folder identified from of adequate power. Make sure that the
menu) or press the “SET” key for over 5 label “FPr” and use parameters “UL” or supplied voltage matches the values speci-
seconds (“Programming” menu). “dL” depending on the case; to start fied for the instrument.
To access the contents of each folder, indi- uploading (downloading) simply press In the versions supplied on 12V, the power
cated by the relevant label, just press the “SET” button. supply must be provided via a safety trans-
“SET” key once. former protected by a 250 mA delayed
You can now scroll through the contents KEYBOARD LOCKING fuse. The probes do not have any insertion
of each folder, modify it or use its func- The instrument includes a facility for dis- polarity and can be lengthened by using a
tions. If you do not use the keyboard for abling the keyboard, by programming the normal bipolar cable (note that if the
over 15 seconds (time-out) or if you pres- “Loc” parameter (see folder with “Dis” probes are lengthened, this will affect the
ence the “FNC” key once, the last value label). If the keyboard is locked, you can behaviour of the instrument in terms of
shown on the display is confirmed and you still access the programming menu by EMC electro-magnetic compatibility –
return to the previous screen mask. pressing the “SET” key. wiring must be done with great care).
The Setpoint can also be viewed. We advise you to keep the probe and sup-
MACHINE STATUS MENU ply cables well away from the power
To access the “Machine Status “menu, DIAGNOSTICS cables.
press and quickly release the “SET” key.
The “Set” folder label appears. To view the The alarm condition is always signalled by CONDITIONS OF USE
Setpoint value, press the “SET” key again. the buzzer (if present) and by the led of
The Setpoint value appears on the display. the alarm icon PERMITTED USE
To change the Setpoint value, use the “UP” The alarm signal produced by a faulty For safety reasons the instrument must be
and “DOWN” keys within 15 seconds. room probe (probe 1) is shown as E1 on installed and used according to the
If the parameter is LOC = y the Setpoint the instrument display 1. instruction provided and in particular,
cannot be changed. under normal conditions, parts bearing
dangerous voltage levels must not be
accessible.
The device must be adequately protected
from water and dust as per the application
and must also only be accessible via the
LED use of tools (with the exception of the
frontlet).
Position Associated function Status The device is ideally suited for use on
Relay 1 ON for relay ON, flashing for delay, disabled protection household appliances and/or similar refrig-
or activation
eration equipment and has been tested
Alarm ON for an active alarm with regard to the aspects concerning
European reference standards on safety.
It is classified as follows: DISCLAIMER
o according to its manufacture: as an
automatic electronic control device to be This publication is the exclusive property
incorporated by independent mounting; of Invensys Controls Italy S.r.L. who
o according to its automatic operating fea- absolutely prohibits its reproduction and
tures: as a 1 B-type operated control type; distribution unless expressly authorised by
o as a Class A device in relation to the cat- Invensys Controls Italy S.r.L.
egory and structure of the software. Although great care has been taken with
regard to the preparation of this docu-
USE NOT PERMITTED ment, Invensys Controls Italy S.r.L. does
Any other use other than that permitted is not assume any responsibility whatsoever
de facto prohibited. It should be noted in relation to its use.
that the relay contacts provided are of a
practical type and therefore subject to The same applies to every individual and
fault. Any protection devices required by company involved in creating and drawing
product standards or dictated by common up this manual. Invensys Controls Italy
sense due to obvious safety reasons should S.r.L. reserves the right to make any
be applied externally. amendment, esthetical or functional, with-
out giving prior notice and at any time.
LIABILITY AND RESIDUAL
RISKS TECHNICAL DATA
Frontal panel protection: IP65.
Invensys Controls Italy S.r.L. shall not be Container: plastic body in resin type
liable for any damages deriving from: PC+ABS UL94 V-0, inspection window in
- installation/use other than that pre- polycarbonate, buttons in thermoplastic
scribed and, in particular, that which does resin.
not comply with safety standards anticipat- Dimensions: frontal panel 74x32 mm,
ed by regulations and/or those given here- depth 60 mm.
in; Installation: on panel, with template 71x29
- use on boards which do not guarantee mm (+0.2/–0.1 mm).
adequate protection against electric shock, Ambient temperature: –5…55 °C.
water or dust under the conditions of Storage temperature –30…85 °C.
assembly applied; Operating environment humidity: 10…90%
- use on boards which allow access to dan- RH (non condening).
gerous parts without the use of tools; Storage environment humidity: 10…90% RH
- tampering with and/or alteration of the (non condensing).
products; Viewing range: –50…99 °C on 2 digit +
- installation/use on boards not complying mark display.
with the standards and provisions of cur- Analog inputs: one PTC or NTC input
rent legislation. (selectable through parameter).
Digital outputs: one relay output, SPDT
8(3)A 250Va relay or SPDT 15A(1hp)
250Va relay (for capacity relay see label
on the instrument).
Measuring range: from –50 to 99 °C.
Precision: 0.5% better than full scale.
Resolution: 1 °C.
Consumption: according to model.
Power supply: according to model.
See label on instrument.

Invensys Controls Italy s.r.l


via dell'Industria, 15 Zona Industriale Paludi
32010 Pieve d'Alpago (BL) ITALY
Telephone +39 0437 986111
Facsimile +39 0437 989066
Internet http:/www.climate-eu.invensys.com

1/2002 ing
cod. 9IS22049

ID 902 2/2
Tab. 1 Parameter description & values table

PARAMETER DESCRIPTION RANGE DEFAULT VALUE U.M.


REGULATOR (folder with “CP”)
diF Relay regulator tripping differential. The regulator stops on reach- 0.1...30.0 2.0 °C/°F
ing the Setpoint value (as indicated by the adjustment probe), and
restarts at temperature value equal to the Setpoint plus the value
of the differential.
Note: the value 0 cannot be assumed.
HSE Maximum possible setpoint value. LSE..302 99.0 °C/°F
LSE Minimum possible setpoint value. -55.0...HSE -55.0 °C/°F
HC Heat/Cool Mode. If set to H the generic regulator actuates for hot H/C H flag
operation. If set to C the generic regulator actuates for cold opera-
tion
REGULATOR PROTECTIVE DEVICES (folder with “CP” label)
Ont Regulator activation time in the event of faulty probe. If set to “1” 0...250 0 min
with Oft at “0”, the regulator is always on, while for Oft >0,
it functions always in duty cycle mode.
OFt Regulator in disabled state time in the event of a faulty probe. If 0...250 1 min
set to “1” with Ont at “0”, the regulator is always off, while at Ont
>0, it functions always in duty cycle mode.
dOn Delay time in activating the regulator relay after switch-on of 0...250 0 sec
instrument.
dOF Delay after switch off. The indicated time must elapse between 0...250 0 min
switch-off of the regulator relay and the successive switch-on.
dbi Delay between switch-ons. The indicated time must elapse between 0...250 0 min
two successive switch-ons of the regulator.
OdO delay time in activating the outputs after switch-on of the instru- 0...250 0 min
ment or after a power failure.
DISPLAY (folder with label “diS”)
LOC Keyboard locking. However, you can enter parameter programming, n/y n flag
modify them and change the status of this parameter to unlock the
keyboard.
y = yes; n = no.
PA1 Password 1. When enabled (value other than 0) it constitutes the 0...250 0 num.
access key for level 1 parameters.
CA1 Calibration 1. Positive or negative temperature value added to the -12.0...12.0 0 °C/°F
value read on the adjustment room probe (probe 1) before being
displayed and used for adjustment.
dro Selection of °C or °F to view the temperature read by the probe. 0/1 1
0 = °C, 1 = °F. flag
CONFIGURATION (folder with label “CnF”)
H00* Probe type selection, PTC or NTC. 0 = PTC; 1 = NTC. 0/1 0 flag
rEL Device version. Read only parameter. / / /
tAb Reserved. Read only parameter. / / /
COPY CARD (folder with label “Fpr”)
UL UpLoad: transferring parameters from instrument to Copy Card. / / /
dL downLoad: transferring parameters from Copy Card to instrument.
/ / /
* For 230 Va model default value is set to 1 (NTC probe , see label on instrument).

WIRING
1-2 N.C. regulator relay output
1-3 N.O. regulator relay output
6-7 Power supply
8-9 Sensor input
A TTL input for Copy Card

IC 901/IC 902 - 12 V A IC 901/IC 902 - 230 V A

1 2 3 6 7 8 9 1 2 3 6 7 8 9