0% found this document useful (0 votes)
30 views1 page

PB 09

Uploaded by

Mohamed salman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

PB 09

Uploaded by

Mohamed salman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES :

1. DO NOT SCALE FROM THE DRAWING USE FIGURED DIMENSION ONLY.

2. ALL LEVELS ARE SHOWN IN METER & DIMENSIONS ARE IN MILLIMETERS


UNLESS MENTIONED OTHERWISE.

3. RESPONSIBILITY OF " INSTA INFRA." SHALL REMAIN LIMITED TO SAFE AND


SOUND STRUCTURAL DESIGN AS TRANSMITTED BY THIS DRAWING.
BAR BENDING SCHEDULE 4. SUPERVISION IF SPECIFICALLY ASKED FOR WE WILL BE PROVIDED TO THE
EXTENT OF VERIFICATION OF REINFORCEMENT ON SITE BUT
RESPONSIBILITY REGARDING CORRECT & SOUND CONSTRUCTION SHALL
SOLELY REST WITH CONTRACTOR/ OWNER/ BUILDER.

5. THIS DRAWING IS PROPERTY OF " INSTA INFRA"AND SHALL NOT BE


REPRODUCED OR USED WITHOUT EXPLICIT PERMISSION OF THIS OFFICE.

6. INFORMATION CONTAINED IN BILL OF QUANITIES CONFORMS TO


01 THESTRCUTRAL DESIGN AND DETAILS AND IS PRESENTED IN GOOD FAITH.

Materials :
Unless noted otherwise the grade of various materials shall be as follows:
1. Lean concrete
02 Provide 100mm lean concrete of mix 1 : 4 : 8 (1 cement : 4 fine aggregate : 8 graded
coarse aggregate) underneath foundation raft / footing.
2. Concrete mix
Concreting shall be done in dry weather conditions and dry site conditions.
All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
a. Walls, Column, Beam & Slab Precast concrete M40
3. Grout

03 a. Grout for filling gaps and joints:


4. Reinforcement
Fosroc Conbextra grout

All reinforcing steel shall be of high strength deformed bars conforming to IS 1786.
Grade FE 500 shall be used with specified yield strength of: fy = 500 N/mm2
5. Structural steel
All steel used for structural members and connections shall be of hot rolled mild steel of
weldable quality conforming to IS 2062.
Steel grade E250 shall be used with following mechancial properties:
Yield stress: fy = 250 N/mm2
Tensile strength: fu = 500 N/mm2
04 Minimum nominal cover:
Nominal cover to meet durability requirements and fire resistance requirements in
accordance with table 16 and table 16A of IS456:
Unless noted otherwise the nominal cover to all steel reinforcements shall be as follows:
Member All sides
Column 40 mm
Beam 25 mm
Slab 20 mm
05
ELEMENT:- PB-09 QTY:- 01 TOTAL

VOLUME :- 0.191Cum COVER:- 25mm CLEAR

06 WEIGHT:- 0.47Ton

EMBEDDED ITEMS
CODE DESCRIPTION QTY.
07
101 2.5T LIFTING DEHA 02

102 50mmØ FLEXIBLE PIPE 02


08

09

10 LEGEND:

M MOULD FACE ERECTION MARK

CUTOUT
A B A RECESS

N.F. NEAR FACE F.F. FAR FACE

0 29-06-2024 ISSUED FOR PRODUCTIONS JS


REV: DATE: DESCRIPTION: DWN CHKD APRD

CLIENT:
Mr.JAYACHANDRA PEELAMEDU, COIMBATORE..

DESIGN AND BUILD CONTRACTOR:

INSTA INFRA
SF No : 238/1A2, Plot No B18,Eastern Part,
Sulur Industrial Estate, Kadampadi Village, Sulur Taluk,
Coimbatore 641 401
Tamilnadu, India.
[email protected]

PROJECT NAME :

RESIDENTIAL PROJECT

DRAWING TITLE :

PRODUCTION DRAWING

3D VIEW PROJECT CODE: DRG.NO: REV:

PB-09 0