0% found this document useful (0 votes)
323 views12 pages

Release Notes For Nemo Analyze 10.1.1

Release_Notes_for_Nemo_Analyze_10.1.1

Uploaded by

Hrvoje Eror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
323 views12 pages

Release Notes For Nemo Analyze 10.1.1

Release_Notes_for_Nemo_Analyze_10.1.1

Uploaded by

Hrvoje Eror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Release Note Nemo Analyze

Version 10.1.1, March 2024

Nemo Analyze - Professional Post-Processing of Drive Test Data

Find us at www.keysight.com Page 1


Table of Contents

Introduction.............................................................................................................................................................................. 3
General Information ................................................................................................................................................................ 4
New Features and Improvements ........................................................................................................................................... 5
Fixed issues ............................................................................................................................................................................ 7
Functionality Notes and Known Issues ................................................................................................................................... 8
Compatibility ............................................................................................................................................................................ 9
Installation ............................................................................................................................................................................. 10

Find us at www.keysight.com Page 2


Introduction
This document contains the release notes of Nemo Analyze version 10.1.1, released in March 2024. The
document describes new functionalities and fixed issues.

Nemo Analyze is a powerful and versatile, cutting-edge analysis tool for performing benchmarking,
troubleshooting, and statistical reporting based on drive test data. Nemo Analyze is a desktop tool that
incorporates an innovative, low-maintenance database engine that has been designed and optimized
specifically for high-performance post-processing of drive test data. Nemo Analyze helps you to
streamline your processes by enabling you to automate the entire data processing chain from a drive test
to an open workbook with analysis results.

Nemo Analyze offers a comprehensive set of technology-specific Key Performance Indicators for the
latest wireless technologies and a wide range of data views that are known to offer the best visualization
of drive test data on the market – yet it is highly cost-effective, easy to set up and to use, and it scales to
meet the needs of organizations of all sizes.

Nemo Analyze offers support for all major wireless technologies, including 5G NR (both scanner and UE
measurements), LTE-A CA, NB-IoT, LTE-M, VoLTE/ViLTE, VoWiFi, and mMIMO. Nemo Analyze
supports all the Nemo product line test tools. Measurement data in CSV (Character-Separated Value)
ASCII format is also supported.

Copyright
The information contained in this document is confidential and no part of it may be copied or reproduced
in any form without the written consent of Keysight Technologies, Inc. Additionally, this document is not to
be passed to or discussed with third parties without the prior written permission of Keysight.

Keysight’s products are subject to continual development and specifications may change. Users of
Keysight’s products and documentation should exercise their own independent judgement to evaluate the
suitability of Keysight’s products and documentation for their particular use. Keysight does not accept any
liability arising from the application or use of the product or this documentation.

All reasonable care has been made to ensure that this document is accurate. If you have any comments
on this document, or would like details of any Keysight products, services or equipment, please contact
us through the Keysight website.

March 2024

Find us at www.keysight.com Page 3


General Information

Nemo Analyze 10.1.1 brings improvements and additions to inbuilding analysis

Nemo Analyze 10.1.1 introduces improvements to handling inbuilding measurements and the floorplans.
Second major enhancement relates to the conversion tools used for migrating custom content from
version 8.92 to the new database versions 10.x.

With the 10.1.1 release we continue to introduce enhancements also to the query performance and
update the Nemo file format to 2.56.

Note!

Existing databases up to version 8.9x cannot be migrated to the new database, so if you are
upgrading from 8.92 or older version, you must reload the measurement data from the original
files when starting to use the new version (10.0 and newer). Also, any custom-made content will
need to be converted for new versions before they can be used.

If you are migrating from version 8.9x (or older), carefully read the section “Upgrade from
versions 8.9x and older”.

Find us at www.keysight.com Page 4


New Features and Improvements
Feature Details
- Add support for multi-SIM measurements (check chapter
3.2).
- Add modem stack information header event. (#MS)
- Add support for Nemo Autonomous Probe cooling
information. (IHI)
- Add subscription ID parameter for call connection event to
define what SIM was used for the call. (CAC)
- Add support for IANA call failure and release causes. (CAF,
Nemo Measurement File format 2.56 CAD)
- Add support for ViSQOL voice quality measurements.
(#VQ, AQI, AQIU, AQDL, AQUL)
- Add support for Streaming Experience Quality Inspector
video quality type. (VQDL)
- Add support for TWAMP one-way delay. (RTT)
- Add support for LTE and NR OFDM scanning frequency
offset. (SCANCONFIG)
- Add support for UMTS MM substate. (CHI)
- It is now possible to compress the images that the
Spreadsheet Report produces
- In some reports, where there are tens of map plots and for
example the original floorplan image is of very high quality,
the report becomes really big in size and is difficult to
handle anymore in Excel. This handling can be improved
Capability to compress map images on by using the new map image compression to make the
Spreadsheet Reports images smaller thus making the resulting report file smaller.
- The compression is set using a registry key. The DWORD
“report.mapimagecompression” (in
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Anite\N
emo Analyze\ServerSettings) is used to determine the
compression rate. Its value can be set from 0 to 100 (50 by
default), the higher the value, the higher the image quality
- It is now possible to set a workbook page to automatically
copy using many different dimensions, for example channel
Improvement on automatic page copy on
number or operator.
workbooks
- This function can be combined with copying per inbuilding
floor if needed.
- In some cases, the measurement file metadata may not
include the information about the used floorplan map. This
is typical for example for PCTel export file format.
- It is now possible to assign a floorplan map for these
measurements
Capability to assign a floorplan to a - This feature also makes it possible to change the floorplan
measurement used during the measurements, but extra care needs to be
taken with this approach, as the user must make sure that
the new floorplan matches the pixels used in the markers
placed during measurement. This means that the new
floorplans configuration must match that of the one used
during measurement
Improved handling of floorplan image - The inbuilding floorplans are now, in all cases, copied to
and tab files common map folder before loading them to workspace

Find us at www.keysight.com Page 5


- Previously inbuilding floorplans (as live maps) were
oriented to true north. This is now changed so, that by
Orientation of inbuilding floors on
default inbuilding floorplans are now in the orientation of
Spreadsheet Reports
the image file, and user can separately select to have it
oriented to true north.
- Custom KPIs made in the old database version (8.92) that
are exported to .aex file, can now be converted to 10.1.1
Conversion tool improvement - This makes it possible to convert the custom KPIs in
batches, making the individual conversion process quicker,
when user has large amount of custom KPIs

Find us at www.keysight.com Page 6


Fixed issues
Feature Details

Fixed an issue with Technology - Technology enumerations were missing NR+WLAN and
enumerations EN-DC+WLAN options
- Ticket #127834
Fixed an issue with default selection of
- There was an issue when setting the default coloring
BTS coloring parameter
parameter for BTS icons on map through the Options menu
Fixed an issue with color legend - Ticket #127932
statistics on workbooks when used in - Sometimes the color legend statistics were not shown for a
Spreadsheet Reports workbook map image when used on Spreadsheet Report
- Ticket #125816
Fixed an issue with order by color count
- When MapX floorplans were used, the “order by color
with MapX floorplans
count” feature wasn’t working correctly
Fixed an issue where BTS sitename and
sector info texts were overlapping each - Tickets #123475, #118172
other
- Tickets #128835, #128884, #130811
Fixed an issue with modifying Operator - There was a problem that when Operator names were
names in the Operator database changed in Operator database (Tools -> Operators), the
changes didn’t get saved.
Fixed an issue where some gaps - Ticket #127111
occurred on the map plots on - There was an issue in data handling that caused some
Spreadsheet Reports route gaps on Spreadsheet Report map plots

Fixed an issue with Cell Type parameter - Ticket #128915


for BTS files - BTS file parameter Cell Type was not parsed correctly
- Ticket #129457
- There was an issue, where in some occasions, rows were
Fixed an issue with Data Transfer duplicated on the Data Transfer Session Statistics query
Session Statistics query - The problem was only seen if the serving system during a
particular data transfer session was both LTE FDD and
LTE TDD

Find us at www.keysight.com Page 7


Functionality Notes and Known Issues

Note Details
If the computer, where Nemo Analyze 10 or newer is installed, had a
previous PostgreSQL installation, it is likely that it will interfere with the
Nemo Analyze database initiation. To overcome this issue, a modification
Previously installed PostgreSQL
must be made in the PATH environment variable. The Nemo Analyze
may cause issues with Nemo
related Postgres binary entry “C:\Program Files\Keysight\Nemo
Analyze database initiation
Analyze\pgsql\bin” should be moved higher in the list than the possible
other PostgreSQL entry (for example “C:\Program
Files\PostgreSQL\15\bin”)
Avoid (replace) reserved words “BTS”, “DATE” (and other SQL reserved
There are certain reserved words
keywords), and certain special characters (e.g., apostrophes, brackets and
and special characters that can
parenthesis) in measurement file names. Otherwise, the measurement
cause issues with file loading or
may not be loaded correctly or there may be problems with workbooks and
usage
reports.
Special characters and Scandinavian characters and special characters (other than underscore)
Scandinavian characters in BTS are not handled correctly when used in BTS file names. These characters
file names are not supported should not be used.
All files loaded to Nemo Analyze must have unique file names to avoid
All measurement files must have
issues with file loading and usage. There is a possibility in client options to
unique names
enable automatic renaming of files with the same names.
If there are several users using the same Nemo Cloud connection in Nemo
Nemo Cloud friendly name must
Analyze Enterprise environment and they have set the name of the Nemo
be the same for all users in the
Cloud connection to be different, some settings will disappear from other
Nemo Analyze Enterprise
users. The names used for the Nemo Cloud connection should be the
environment
same for all clients.
When saving reports to PDF, they do not scale well and cause blank
pages in the result PDF. This is because many of the pre-defined reports
Save as PDF scaling issue
are not optimized for such exports. If there is a need to export to PDF, it
should be considered when designing the reports.
On some computers, maps are not correctly generated for reports.
Instead, a blue or black background is drawn for the area. This
Blue or black map plot on can be fixed in the Registry Editor by adding a new DWORD
spreadsheet reports “WorkbookExportMode” with value 1 to
“Computer\HKEY_CURRENT_USER\Software\Anite\Nemo
Analyze”
If a user copies an event in Event Scheduler, deletes it, and then
Pasting a deleted event in the
Event Scheduler causes a crash tries to paste it to Event Scheduler, a crash may occur. Copy and
paste works fine if the event is not deleted before paste.
Display scaling for text and apps It has been noted that on some computers, the display scaling
should be set to 100% when affects how the report design looks compared to the final
designing server reports with map generated report. To avoid such a problem, the display scaling
plots should be set to 100%.

Find us at www.keysight.com Page 8


Compatibility

File format compatibility

Nemo file format


Nemo Analyze 10.1.1 is compatible with Nemo log files up to Nemo file format v2.55 and all older file
format versions.

- Note that Nemo Analyze can also read newer files than the ones mentioned above, however, the
new information elements are discarded.

TEMS file format


Nemo Analyze 10.1.1 supports files from the following TEMS tools (up to Route Reader 23.3):

- TEMS Automatic 12.x, 11.x, 10.x, 9.2


- TEMS Investigation 23.3, 22.x, 21.x, 20.x, 19.x, 18.x,17.x, 16.x
- TEMS Pocket 23.1, 22.x, 21.x, 20.x, 17.x, 16.x, 15.x, 14.x
- TEMS Symphony 7.x
- TEMS Sense 5.2, 4.x, 3.x, 2.x, 1.x
- TEMS Paragon 5.3, 4.x, 3.2, 3.1, 2.x, 1.x
- TEMS Voyager 2.3.1, 2.x, 1.x

Note that not all metrics and events from TEMS files are supported. Missing metrics and events may be
added in future versions where applicable.

Nemo Analyze can also typically read newer files, but there may be changes that prevent file loading.

R&S MNT MF (SwissQual) file format


Nemo Analyze 10.1.1 supports R&S MNT MF files up to version 22.2. Note that some of the older
versions may not be fully supported. Currently supported technologies are 5G NR, LTE, UMTS, and
GSM.

Note that not all metrics and events are supported, missing metrics and events may be added in future
versions where applicable.

Nemo Analyze can also typically read newer files, but there may be changes that prevent file loading.

PCTEL SeeHawk export file format


Nemo Analyze 10.1.1 supports PCTEL SeeHawk export DTR file format (file extension “.dtr”) up to
version 1.0.18.0.

Find us at www.keysight.com Page 9


Note that not all KPIs from the PCTEL files are supported. Missing metrics may be added in future
versions where applicable.

Installation

First-time installation
 Installation must be run under Administrator account or other user account with administrative
privileges.
Install Nemo Analyze 10.1.1 by running the setup. Follow the instructions of the setup wizard. Restart the
computer after installation if required by the setup wizard.

Upgrade from version 10.x


 Installation must be run under Administrator account or other user account with administrative
privileges.
1. Uninstall the previous version of Nemo Analyze from Control Panel  Add or Remove programs, NOT by
running the Nemo Analyze 10.1.1 setup. Restart the computer if required by the setup wizard.
2. Install Nemo Analyze 10.1.1 by running the setup. Follow the instructions of the setup wizard. Restart the
computer after installation if required by the setup wizard.

Upgrade from versions 8.9x and older


Note that the existing database from versions 8.9x or older cannot be migrated to the new version!

Currently, direct upgrade from versions 8.9x and older is not supported, because we want the user to be
aware of the change and be sure about migrating to the new database technology.

There are conversion tools provided to help in the migration process. The custom report templates,
workbooks and custom queries can be converted using these tools. The Nemo Analyze User Guide
explains the conversion process in the section “Installing Nemo Analyze”. If further assistance is needed,
please reach out to the Nemo Customer Support.

We highly recommend installing the new version first on another computer, so that the
functionality can be evaluated before making the final migration to new version.

In order to upgrade, the previous version must be completely removed before installing the new version.
This means that in addition to the uninstallation of the previous version, all related registry entries, folder
content related to the old version and such should also be removed. The C:\Nemo Tools\Nemo Analyze
and C:\Nemo Tools\Nemo Analyze Datastore (default paths, if installed to different location, the paths
should be changed accordingly) folders should be backed up to some other location.
 Installation must be run under Administrator account or other user account with administrative
privileges.
1. Uninstall the previous version of Nemo Analyze from Control Panel  Add or Remove programs, NOT by
running the Nemo Analyze 10.1.1 setup. Restart the computer if required by the setup wizard.

Find us at www.keysight.com Page 10


2. Remove the registry entries related to Nemo Analyzev using Windows Registry Editor
a. Delete “Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Anite\Nemo Analyze”
b. Delete “Computer\HKEY_CURRENT_USER\SOFTWARE\Anite\Nemo Analyze”
c. Delete the “Analyze” entry from
“Computer\HKEY_CURRENT_USER\SOFTWARE\Anite\Installed”
3. Back up and move the Nemo Analyze related folders to a different location
a. Default paths:
i. C:\Nemo Tools\Nemo Analyze
ii. C:\Nemo Tools\Nemo Analyze Datastore
4. Install Nemo Analyze 10.1.1 by running the setup. Follow the instructions of the setup wizard. Restart the
computer after installation if required by the setup wizard.

Find us at www.keysight.com Page 11


Learn more at: www.keysight.com
For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus

Find us at www.keysight.com Page 12


This information is subject to change without notice. © Keysight Technologies, 2023, Published in USA, December, 2023

You might also like