Product Data Sheet Roxar 2600 Multiphase Flow Meter Rapid Adaptive Measurement en 7260140

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

Product Data Sheet

RXPS-002516, Rev B
October 2022

Roxar™ 2600 MPFM


Multiphase Flow Meter with Rapid Adaptive Measurement™

As oil and gas operators worldwide adjust their production methodologies and target more challenging
reservoirs, the multiphase flow metering technology must be robust and reliable in ever more demanding
conditions.
The Roxar 2600 MPFM key features:
■ Real time, three-phase measurement without the need for separation
■ Modular design and selectable advanced software features to fit your application needs
■ Flexible and adaptable configuration options throughout the lifetime of your field
■ Intuitive and user-friendly operator interface tool for calibration and configuration
■ The Roxar Rapid Adaptive Measurement embedded software supporting automation and trustworthy
measurement in dynamic multiphase flow
■ Robust full-range non-gamma meter version available, for operators who prefer to avoid the use of a
radioactive source
■ Fully compatible with Emerson Connected Services, giving operators continuous access to Emerson
expertise and support
■ The Roxar Multiphase Salinity System (RMSS) available as an additional module, providing live salinity
content information when operating in water-dominant flow
Roxar 2600 MPFM October 2022

Roxar 2600 Multiphase Flow Meter model options and


specifications
Emerson offers a modular approach to the Roxar 2600 Multiphase Flow Meter. This makes it possible for operators to select only
the modules suitable for their application and measurement needs, fully confident changes can be made in field if application
needs change over time.

Model M MV MVG
description
Key raw data Base model – impedance M model plus dP over venturi MV model plus gamma density
measurements: measurement measurement measurement
Application Single well applications Single or multi-well applications Single or multi-well applications
description: Direct well head monitoring and Flow rates for oil, water and gas Flow rates for oil, water and gas
trending of oil, water and gas over a wide range of applications over a full range of applications
fractions and rates
Operating range: ■ 0 - 85% gas volume fraction ■ 0 - 100% GVF ■ 0 - 100% GVF
(GVF) ■ 0 - 100% WLR ■ 0 - 100% WLR
■ 0 - 100% water liquid ratio
■ Flow velocity 2 - 40 m/s ■ Flow velocity 1 - 40 m/s
(WLR)
■ Flow velocity 5 - 25 m/s

Mechanical specification
Category Specification description
Installation Vertical with upwards flow
Meter sizes ID 1½ in (35 mm) to ID 8 in (173 mm)
Design pressure Up to 5,000 psi (345 bar)
Design temperature -4 °F (-20 °C) to 266 °F (130 °C)
Lower minimum temperatures can be accommodated, assessed on a case by case basis.
Meter body wetted parts Duplex UNS S31803
material options Stainless steel UNS S31600
Super duplex UNS S32760
Inconel 625 UNS N06625
PEEK natural
Flange connection ANSI flanges or hubs with clamp connectors
Density measurement Compact gamma system
(when applicable) Source: Cs-137, 2, 5 or 8.3 mCi
Half-life 30.1 years

2 www.Emerson.com/Roxar
October 2022 Roxar 2600 MPFM

Communication and electrical specification


Category Specification description
Power supply 18 - 30 VDC
100 - 240 VAC
Power consumption: 22 W
Communications interface RS-232
RS-485
Ethernet
Communications protocol Modbus RTU
Modbus TCP
HTTP
Flow computer mounting Painted aluminum Ex d housing for hazardous area
SS 316L Ex d housing for hazardous area
SS 316L IP 66 housing for safe area
Rack mountable arrangement for safe area

Standards and certifications


Category Standard or certification description
Hazardous area certification ATEX
IECEx
CSA C/US
TR CU 012 (EAC)
Design code ASME B16.5 & ASME B31.3
Material specification compliance ASME B31.3
Sour service wetted parts NACE MR 0175
ISO 15156

www.Emerson.com/Roxar 3
Roxar 2600 MPFM October 2022

Measurement uncertainty specification


MVG meter version

GVF range Repeatability


< 25% 25-90% 90-95% 95-98% >98%
Gas rate (%rel) 7.0% 5.0% 5.0% 5.0% 5.0% ¼ of %
Liquid rate (%rel) 3.0% 3.5% 5.0% 8.0% 10%(1) ¼ of %
Water-liquid ratio (%abs) 2.0% 2.5% 3.5% 4.0% 10%(1) ¼ of %
1. Uncertainties given at a 95% confidence interval.
2. Requires correct PVT and water conductivity input.
3. Applicable for operating pressures above 73 psi (5 bar).

(1) As the liquid fraction approaches zero, the uncertainties increase beyond this figure and a case-by-case calculation can be conducted.

MV meter version

GVF range Repeatability


< 25% 25-90% 90-95% 95-98% >98%
Gas rate (%rel) 8.0% 6.0% 5.0% 5.0% 5.0% ¼ of %
Liquid rate (%rel) 3.5% 4.0% 5.0% 10% 12%(1) ¼ of %
Water-liquid ratio (%abs) 2.5% 3.0% 4.5% 5.0% 10%(1) ¼ of %
1. Uncertainties given at 95% confidence interval.
2. Requires correct PVT and water conductivity input.
3. Applicable for operating pressures above 73 psi (5 bar).

(1) As the liquid fraction approaches zero, the uncertainties increase beyond this figure and a case-by-case calculation can be conducted.

M meter version
M-version uncertainties are 10% relative on gas and liquid rates and 5% absolute on WLR.

4 www.Emerson.com/Roxar
October 2022 Roxar 2600 MPFM

Software features
The Roxar 2600 Multiphase Flow Meter comes with the Rapid Adaptive Measurement core software as standard. Several value-add
features are available to optimize for application requirements.

Features Functionality
Standard Core One mode
Adaptive density measurement
Parallel computation
Basic alarms and diagnostics
Embedded PVT
Advanced Advanced PVT Multistage flashing
Gas lift integration
Detect and correct In-situ flow verification
In-situ calculation verification
In-situ sensor verification
Layer compensation
Non-gamma Non-gamma one mode
Connect Performance monitoring

www.Emerson.com/Roxar 5
Roxar 2600 MPFM October 2022

Roxar 2600 MPFM MVG

Meter Sizes: ID 1½ in (35 mm) to 4 in (87 mm)


Flange Connection: ANSI flanges
Design Pressure: 3750 psi (258 bar)

Meter Sizes: ID 2 in (50 mm) to 8 in (173 mm)


Flange Connection: Hubs with clamp connectors
Design Pressure: 5000 psi (345 bar)

6 www.Emerson.com/Roxar
October 2022 Roxar 2600 MPFM

Roxar 2600 MPFM MV

Meter Sizes: ID 1½ in (35 mm) to 4 in (87 mm)


Flange Connection: ANSI flanges
Design Pressure: 3750 psi (258 bar)

Meter Sizes: ID 2 in (50 mm) to 8 in (173 mm)


Flange Connection: Hubs with clamp connectors
Design Pressure: 5000 psi (345 bar)

www.Emerson.com/Roxar 7
Roxar 2600 MPFM October 2022

Roxar 2600 MPFM M

Meter Sizes: ID 2 in (50 mm) and 3 in (67 mm)


Flange Connection: ANSI flanges
Design Pressure: 3750 psi (258 bar)

8 www.Emerson.com/Roxar
October 2022 Roxar 2600 MPFM

www.Emerson.com/Roxar 9
RXPS-002516
Rev. B
October 2022

For more information: Emerson.com


©2022 Roxar AS. All rights reserved.

The Emerson logo is a trademark and service mark of Emerson


Electric Co. Roxar is a trademark of Roxar AS. All other marks
are property of their respective owners.

Roxar supplies this publication for informational purposes only.


While every effort has been made to ensure accuracy, this
publication is not intended to make performance claims or
process recommendations. Roxar does not warrant, guarantee,
or assume any legal liability for the accuracy, completeness,
timeliness, reliability, or usefulness of any information,
product, or process described herein. All sales are governed by
our terms and conditions, which are available on request. We
reserve the right to modify or improve the designs or
specifications of our products at any time without notice. For
actual product information and recommendations, please
contact your local Roxar representative.

Roxar products are protected by patents. See http://


www.emerson.com/en-us/automation/brands/roxar-
home/roxar-patents for details.

You might also like