PDF of Original Candela-USA

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

The Gentle Pro Series

A world leader in
hair removal and
so much more
755 nm and 1064 nm lasers for laser hair removal,
vascular and skin treatments.
The Gentle Pro Series
For over 20 years, whenever physician practices, hair removal clinics and medical spas across the globe wanted to
provide their patients with the gold standard in laser hair removal and more, they turned to the Gentle series of lasers.
Today, whatever your business needs, from hair removal to vascular lesions to pigmented lesions, the Gentle Pro series
has a device that’s right for you.

Patient Satisfaction Efficiency


A positive experience means patients will be Power, speed and larger spot sizes all
coming back for more and spreading the word combine to let your practice treat more
about their Gentle Pro procedure. patients in less time.
• Long-lasting results • Up to 80% permanent hair reduction
after 3 treatments1
• Comfortable
• Treat large areas like back
• Fast
and legs in just minutes

Ease of Use Versatility


Great technology always keeps the user in While our Gentle Pro devices are best
mind, which is why the Gentle Pro series known for hair removal, that’s only
of devices is designed to make it simple the beginning of what your practice
for doctors and technicians to treat every can offer. Our 755 nm and 1064 nm
patient. wavelength laser technology also
• Intuitive interface treats:

• Guided setup • Pigmented lesions

• Easy selection and storing • Redness and facial vessels


of treatment parameters and histories • Spider and leg veins
• Single, lightweight, ergonomic handpiece for • Wrinkles
simple, comfortable operation
• Onychomycosis (nail fungus)

1
Comparing 18- versus 12-mm spot size in hair removal using a Gentlelase 755-nm alexandrite laser. Nouri K, Chen H, Saghari S, Ricotti CA Jr. Dermatol Surg. 2004 Apr;30(4 Pt 1):494-7.
Comparison of long-pulsed alexandrite and Nd:YAG lasers, individually and in combination, for leg hair reduction: an assessor-blinded, randomized trial with 18 months of follow-up. Davoudi
SM, Behnia F, Gorouhi F, Keshavarz S, Nassiri Kashani M, Rashighi Firoozabadi M, Firooz A. Arch Dermatol. 2008 Oct;144(10):1323-7. doi: 10.1001/archderm.144.10.1323.
Clinical comparison of four hair removal lasers and light sources. Amin SP, Goldberg DJ. J Cosmet Laser Ther. 2006 Jun;8(2):65-8.

Untoward Responses - Laser Hair Removal and Vascular Lesions: Burning, blistering, scabbing, crusting, hypopigmentation, hyperpigmentation, purpura, or herpes simplex activation, in rare
cases, scarring may result. Hypopigmentation or hyperpigmentation may not appear for 1 - 2 weeks and in rare cases may last for months or longer. If hypopigmentation or hyperpigmentation
occurs treatment should not be performed until pigmentation returns to normal.
Dual Wavelength
Delivery System
Single, lightweight,
ergonomic handpiece Intuitive Touch Screen
delivering both 755 Redesigned to help
nm and 1064 nm you select treatment
wavelengths for ultimate parameters more easily.
treatment convenience.

Multiple Spot Sizes Variable Pulse Duration


Microsecond to
6, 8, 10, 12, 15 and
millisecond pulse
18 mm spot sizes are
durations provide
anatomically appropriate
superior results when
and offer a wide range
treating pigmented and
of fluence delivery
vascular lesions on a
capabilities.
variety of skin types.

Large Spot Size Delivery


DCD or Air Cooling –
Dual wavelength 20, 22 and
It’s Your Choice
24 mm spot sizes enable
Choose from either
shorter treatment times.
our patented cryogen-
based Dynamic Cooling
Device™ (DCD™), which
Specialty Spot Sizes saves time, is operator
Specialty Delivery System independent, scales with
option with 1.5, 3 and 3x10 fluence and provides
mm spots for vascular and consistent protection of
pigmented lesions, and 5mm the epidermis, or the Air
for nail fungus.* Cooling Compatible™
(ACC™) system.

THE GENTLE FAMILY OF PRODUCTS IS A WORLD LEADER IN LASER HAIR REMOVAL WITH:

20 10,000+ 86
YEARS OF SYSTEMS INSTALLED COUNTRIES
EXPERTISE
*1.5 & 3mm spot sizes available with GentleYAG Pro & GentleMax Pro systems.
The Gentle Pro Series of Products
A world leader in hair removal and so much more.
Whatever your business needs, from hair removal to vascular lesions to pigmented lesions, the Gentle Pro Series
has a device that’s right for you. You can purchase the GentleMax Pro system with its dual laser configuration or the
GentleLase Pro or GentleYAG Pro device with the single laser that is best suited to your patient needs.

Dual 755 nm Alexandrite & 1064 nm Nd:YAG laser


Hair removal and so much more with the combined power and treatment capabilities of GentleLASE Pro and GentleYAG Pro

Diffuse Redness* Wrinkles*

Before After* Before After*

Photos courtesy of Stephen W. Eubanks, M.D. Photos courtesy of Mark Taylor, M.D.

755 nm Alexandrite laser


The preferred choice for hair removal in lighter skin types; also recognized for pigmented and vascular lesion removal

Pigmented Lesions Hair Removal

Before After*
Before After*

Photos courtesy of Jonathan S. Crane, D.O. Photos courtesy of Münevver Ercan, M.D.

1064 nm Nd:YAG laser


The preferred choice for hair removal in darker skin types; also treats vascular lesions, wrinkles and onychomycosis

Leg Veins Pseudofolliculitis Barbae

Before After* Before After*

Photos Courtesy of Marguerite Germain, M.D. Photos courtesy of Olga Zerpa, M.D.
Dynamic Cooling Device (DCD ) ™ ™

The single most important differentiating


feature on our Gentle Family of Lasers.
The speed, proven results & ease-of-use advantages of our Gentle lasers enjoy versus the
competition are directly attributable to DCD. Further, DCD is operator technique independent—
it will provide the same epidermal protection no matter how fast the laser is fired.
Patient safety is assured as is patient satisfaction.

Dynamic Cooling Device (DCD)


large spot delivery system handpiece

“ Because of the proven


results in hair reduction, this
device has been enthusiastically
received by our patients.”
– E. Victor Ross, MD,
La Jolla, CA

DCD Advantages

Consistent Comfortable Cost Effective


DCD delivers the same amount DCD maximizes patient comfort and Our distinctive delivery method
of cryogen protection with each epidermal protection by delivering ensures you use only the amount
laser pulse from start to finish. targeted bursts of our non-toxic of cryogen you need depending on
Because the DCD settings are cryogen to the top layers of the skin patient comfort and the treatment
set by the user, but regulated by milliseconds before the laser pulses. you are performing. There is no
the laser, this cooling method is This evaporative coolant doesn’t waste or “left-over” cryogen, and
technique independent and allows affect underlying targeted structures, nothing to clean up afterwards.
for reproducible epidermal protection doesn’t impede visibility, and quickly Best of all, for tenths of a cent per
and treatment outcomes. evaporates without leaving any messy pulse, you’re offering your patients
residue. the most advanced patient comfort
system available.
A world leader in hair
The Gentle Pro Series removal and so much more.

The ultimate laser hair removal and integrated aesthetic platform for every practice.

SYSTEM SPECIFICATIONS ALEXANDRITE FLUENCE


Laser Type Alexandrite Nd:YAG Spot Size (mm) Fluence (0.25 ms to 100 ms)
Wavelength 755 nm 1064 nm 3 40 to 400 J/cm2

Repetition Up to 10 Hz Up to 10 Hz 3 x 10 10 to 200 J/cm2


5 9 to 40 J/cm2
Max Delivered Energy 53 Joules (J) 80 Joules (J) 6 6 to 150 J/cm2

Pulse Duration 0.250 -100 ms 8 6 to 100 J/cm2


10 6 to 60 J/cm2
Spot Sizes 6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 18 mm
12 10 to 40 J/cm2
Specialty Delivery
Small - 1.5, 3, 5 and 3 x 10 mm 15 6 to 30 J/cm2
System Optional Spot
Large - 20, 22 and 24 mm
Sizes 18 6 to 20 J/cm2
Beam Delivery Lens-coupled optical fiber with handpiece 20 5 to 16 J/cm2
Pulse Control Finger switch, foot switch 22 4 to 13 J/cm2

Dimensions 107 cm H x 46 cm W x 69 cm D (42” x 18” x 27”) 24 3 to 11 J/cm2

Weight 118 kg (260 lbs)


200-240 VAC, 50/60 Hz, 30 A, 4600 VA single
Electrical ND:YAG FLUENCE
phase
Spot Size (mm) Fluence (0.25 ms to 100 ms)
1.5 300 to 520 J/cm2
Patented Dynamic Cooling Device
Integrated controls, cryogen container 3 130 to 400 J/cm2
and handpiece with distance gauge 3 x 10 80 to 300 J/cm2
5 9 to 55 J/cm2
Cryogen HFC 134a
6 6 to 200 J/cm2
DCD Spray Duration User adjustable range: 10-100 ms
8 6 to 150 J/cm2
DCD Delay Duration User adjustable range: 20-100 ms 10 6 to 100 J/cm2
DCD Post-Spray Duration User adjustable range: 10-50 ms 12 10 to 70 J/cm2
15 6 to 44 J/cm2
Optional Air Cooling Compatible (ACC) Handpiece Available
18 6 to 30 J/cm2
20 5 to 24 J/cm2
22 4 to 20 J/cm2
24 3 to 16 J/cm2
For more information about how the Gentle Pro systems may
help achieve your practice goals, contact your local Candela sales
professional at 800-733-8550, or visit candelamedical.com.

*Photos have been unretouched and individual results may vary 1 1.5 & 3mm spot sizes available with GentleYAG Pro & GentleMax Pro systems.

© 2019 Candela Corporation. This material contains registered trademarks, trade-names and brand names of Candela Corporation or its subsidiaries,
including Syneron Candela, GentleMax Pro, GentleLase Pro, GentleYAG Pro, DCD Dynamic Cooling Device, Air Cooling Compatible (ACC) Handpiece
and Specialty Delivery System. All other trademarks are the property of their respective owners. All rights reserved. PB93152EN-NA

You might also like