MX Series

Intelligent Fire Alarm Systems

MX700 Series Panels


MX704 (4-Loop Panel)
MX704-2 (2-Loop Panel)
INTELLIGENT ADDRESSABLE
FIRE ALARM CONTROL PANEL

Optional
Built-In
Printer

Typical Facial Layout

1330h-(cl-1)

Features and Benefits


 Certified to EN54-2:1997 +A1:2006, EN54-4:1997 + A1:2002 + A2:2006
 LPCB Approved
 Using advance microprocessor technology with large memory capacity
 Enhance user interface combining LCD Colour Touch Screen and Keypad Access
 Support real time visual algorithm
 Enhance false alarm prevention
 Dirty Detector Reporting
 Keypad and PC programming
 Optional Built-in Multiple interface protocol such as USB / Ethernet / Can-Bus / Serial / RS485
 Support Loop Powered Devices for extra saving on cabling cost
 Built-In Printer (Optional)
 Built-in Programmable LED Zone Indicators

Multron Systems Pte Ltd DATA SHEET


217 Kallang Bahru, Multron Building Copyright © The information contained in this Data Sheets remains the
property of Multron Systems Pte Ltd, and is not to be altered or reproduce
Singapore 339 347 without permission.
: (65) 6395 6868
Multron reserves the right to change any specification without prior notice.
: (65) 6395 6869
: info @ multron.com.sg Version : 19-08-2019
MX Series
Intelligent Fire Alarm Systems
Overview
The MX700 series comprise of a range of analogue addressable, microprocessor based fire alarm control
equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of
system design, to meet the full requirements of the project. The MX004 Intelligent Fire Alarm Control Panel is
designed and manufactured to meet the requirement of BS EN54 Part 2&4.

The MX700 is designed to provide early warning fire detection, to quickly identify the location of fire and
provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously,
the MX700 will alert and evacuate the occupants, and control all necessary auxiliary command functions such
as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects
requirements configured though Command Builder Set-up.

System Capacity
 Standard sizes of 2-Loop and 4-Loop Panels are available
 Support up to 254 Devices per Loop
 Network up to 128 Panels x 4-Loop
 Programmable Capacity :-
 Up to 3000 Zones
 Sounders Groups : 1-1000
 Modules Groups : 1001- 2000
 Up to 160 LED Zone Indicators (Depending on Panel size)

Commissioning Advantage
 Auto Enrolling of Devices
 Loop Mapping with colour coding status
 Monitor device mismatch and dual address conflict
 Command Builder to create requirements for fire event scenario
 With Loop protection against power surge
 One-man test with On/Off sounder Programming Protection

With a wide selection of Audio/Visual Devices,


Detectors, Modules, and etc., to meet today’s
demanding criteria for a modern Fire Alarm
System., The MX Series is the ideal choice…
MX Series
Intelligent Fire Alarm Systems
Technical Specification

Approvals LPCB / CE-CPR

Standards EN54-2:1997 +A1:2006, EN54-4:1997 + A1:2002 +A2:2006

Model MX704-2 MX704


Number of Loop 2-Loop, Class A 4-Loop, Class A
Loop Expansion Expandable up to 6-Loop (As Stand Alone, without Network Card)

Input Voltage 240VAC +10% -15%, 50/60Hz

Input Current Consumption 1A

PSU Output to CIE 24.5 to 28.5 VDC

2 x 12V 24AH - Sealed Lead Acid Battery


Standby Battery Capacity
(Based EN54-4 capacity for 24hrs Standby + 30mins Alarm)

Inter-Panel Communication Can Bus [loop]

Panel Network Capacity 128 Panels x 4-Loop

Interface Port USB / RS485 Serial / RS232 Serial / Ethernet

Memory [Non-Volatile] 1000 Fire Events / 10,000 General Event

Zones 3,000 programmable

Total Group 3,000 programmable


- Sounder Group 1,000 programmable

- Common Group 2,000 programmable

Protocol/Addressing Proprietary / Value range from 1 to 254

Protection Built-in 4kV Surge protection

Loop Current Rating 24Vdc / Max. 450mA per Loop

Cabling Length / Cable Type 1.2km Max Length / 2 x 1.5mm² Cable (Twisted Pair)

Programmable Relays 4 Circuits : Normally Open/Close

Programmable Input 1 Circuit: Power limited 24Vdc (for future use)

Programmable Auxiliary Power 19 to 28 VDC (Note: Current Limited)

Fixed Outputs (FPE/Sounder) 2 Circuits: 18 to 28 VDC (Note: Current Limited)

Indicator 24 LED Status / 160 Zone Indicators

Display 7” TFT Touch Screen (Colour)

Keypad 5 Brigade buttons and Programming Keypad

Material / Colour Steel with window outer Door / Red with Black Facial

Dimension 560mm (Height) x 520mm (Width) x 185mm (Depth)

Weight 19 Kg (without Battery)

Humidity 0 to 95% Relative Humidity, Non condensing

Ingress Protection IP 30

Operating Temperature 0 to +40°C


MX Series
Intelligent Fire Alarm Systems

Loop and Network Termination Details

Communication Card is provided as standard


inside the Panel for MX004/4 only.
To be ordered separately for other Panels.