Crewpetro Wellcontrol Pre Course Study Guide - Subsea
Crewpetro Wellcontrol Pre Course Study Guide - Subsea
Crewpetro Wellcontrol Pre Course Study Guide - Subsea
Hydrates:
Gas in Riser:
• If no response from flow meters when functioning annulars or rams, change pods and try again.
• After functioning annulars or rams if fluid flow continues to register, put that element into block and
call the subsea engineer.
• While drilling if alarm and rapid loss of accumulator pressure with flow meter registering fluid
movement, stop drilling and put all functions into block and call subsea engineer.
• Pilot fluid operates the Sub-Plate Mounted (SPM) valves.
• Shuttle valves isolate the selected pressurized pod from the redundant vented pod
• Colder, denser, mud in choke line and kill lines could cause shut-in surface pressures to read lower
than what they actually are.
• Changing to a lighter fluid in the choke line will cause SICP or MASP to be higher.
• Changing to a heavier fluid in the choke line will cause SICP or MASP to be lower.
• If you are concerned about low casing and kill line pressures, you should flush the choke and kill line
with clean mud
Gas in Riser:
Riser Margin:
• It is the mud weight increase to compensate for the loss of the Riser.