Eaton Capitole Salesaid ENG
Eaton Capitole Salesaid ENG
Eaton Capitole Salesaid ENG
Distribution - ACBs ll range of devices Must have fu - MCBs Bs - Fused-switches ) - M CC ks/4 pole (SP/TP + neutral lin s essential e-over and interlock Chang corporated in CTs have to be in fit even in service to structure - easy gid - end frame ruction must be ri Const type best!! be fully rated Neutrals have to and easy, must - has to be fast Cabling om front, of space, access fr have plenty tes removable gland pla oggle or rotary - want choice of t MCCBs handle
distribution Motor control and Modular build motor control must incorporate as required and/or distribution rvices!!! including building se Arc-free design - absolute safe to modify live MUST HAVE hdrawable/ Outgoing fixed/wit plug-in options s - excellent Compact starter cabling must space usage - NB still be easy intelligent Conventional and ial nt motor control esse available for Shutters must be - PERIOD. hdrawable starters wit 54 option IP41 minimum, IP and switchboards sential for MCCs Plug-in devices es rength and* frames best for st n using end Rigid constructio ion at flexibility of applic
Notes
Technical data
Capitole 40 Electrical data Rated operational voltage Rated frequency Main busbar data Rated insulation voltage Rated impulse withstand voltage Rated current Rated short-time withstand current Rated peak withstand current Vertical distribution busbar data Rated insulation voltage Rated impulse withstand voltage Rated current Rated short-time withstand current Rated peak withstand current Outgoing units Enclosure data Degree of protection Form of separation Entry of cables Access Standard Colour Standards Certifications IP41 (IP54 on request) Form 4a Type 2, Form 4b Types 3, 6 and 7 Top and/or bottom Front or rear RAL 7035 IEC 60439-1, BS EN 60439-1 KEMA-Keur, Lloyd's Register of shipping 1000 V 12 kV 1420 A 80 kA 1s 176 kA withdrawable / fixed / plug-in 1000 V 12 kV 6300 A 80 kA 1s 220 kA 690 V 50/60 Hz
Certified to national
Capitole 40
LV Distribution and Motor Control System
Personal safety
Form 4a Type 2, Form 4b Types 3, 6 and 7 internal segregation Shutters guard the distribution busbars when drawers are removed Designed to limit effects of internal arcing faults - Possible to connect outgoing cables with switchboard live Fault-free zone option: - Insulated main busbars - Incomer busbar connections insulated - Phase segregation of incoming and busbar side terminals of incoming devices
System flexibility
Compartments for withdrawable units may be modified without process supply interruption Standard and reduced height cubicle designs with configurations for front/rear connection, top/bottom cable entry Corner cubicle facilitates right-angled assemblies Up to 32 units per column Wide range of optional modules - Clink motor management system - Soft starters - Frequency converters (variable speed drives) - PLC controlled change-over systems - Power factor correction
Operational reliability
Unique plug-in contacts for withdrawable units prevent wear, short-circuit damage and welding Vertical busbars enclosed in insulated chamber Segregation continuous up to and including withdrawable main contacts precludes faults Quality controlled manufacturing guarantees all fixings, including terminations, correctly tightened
Maintenance
Low maintenance design All components/connections accessible from the front except for rear cable connections Maintenance-free withdrawable unit contacts Contact blocks may be quickly changed
Functionally flexible
Modular design provides maximum flexibility and minimum build time May be re-configured on-site if necessary Top and/or bottom cable entry Full spectrum of protection, metering, Building Management System and supply change-over options
Technical data
Capitole 20 Electrical data Rated operational voltage Rated frequency Main busbar data Rated insulation voltage Rated impulse withstand voltage Rated current Rated short-time withstand current Rated peak withstand current Vertical distribution busbar data Rated insulation voltage Rated impulse withstand voltage Rated current Rated short-time withstand current Rated peak withstand current Outgoing units Enclosure data Degree of protection Form of separation Entry of cables Access Standard Colour Standards Certifications IP31 Form 4a Type 2, Form 4b Type 6 Top and/or bottom Front RAL 7035 IEC 60439-1, BS EN 60439-1 KEMA-Keur 1000 V 12 kV 2x1250 A (centre fed) 50 kA 1s 110 kA plug-in 1000 V 12 kV 3200 A 50 kA and 65 kA 1s 110 kA 690 V 50/60 Hz
Company Information
Eatons Electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, world-class manufacturing methods, and global engineering services and support, Eatons Electrical business provides customer-driven solutions under brand names such as Cutler-Hammer, Durant, Heinemann, Holec and MEM, which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.eatonelectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2005 sales of $11.1 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 59,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com.
Eaton Electric Limited Reddings Lane Birmingham B11 3EZ United Kingdom Customer Support Centre Tel: +44 (0)8700 545 333 Fax: +44 (0)8700 540 333 email: [email protected]
Eaton Electric B.V. P.O. Box 23 7550 AA Hengelo The Netherlands Customer Support Centre Tel: +31 (0)74 246 4012 Fax: +31 (0)74 246 3597 email: [email protected]
2006 Eaton Electric Limited All rights reserved Printed in NLForm No Proof Copy Only June 2006 BR01900001U