Manuel Du Variateur de Fréquence Inverter AT2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Inverter

AT1--Single-phase to three-
phase
AT2--Single-phase to single-
phase
AT3--Three-phase to three-
AT4- -Single-phase to three-phase
phase

AT Simple general series


High performance and low
noise/ Mini AC motor
driver
Charter 1 Installation and wiring
1. Main circuit terminal and function description
(1) Single-phase to three-phase ( for AT1 , AT4 )

Terminal Function description


label
L, N Single phase AC 220V input terminal
U, V, W Output terminal connect to Three phase
220V AC motor
GND Grounding terminal
(2) Single-phase input and output (for AT2)

Terminal Function description


label
L, N Single phase AC 220V input terminal
U, V, W Output terminal connect to Single
phase 220V AC motor
GND Grounding terminal

2页
(3). Three-phase input and output (for AT3)

Terminal Function description


label
R,S,T Three phase AC 380V input terminal
U, V, W Output terminal connect to Three phase
380V AC motor
GND Grounding terminal
2. Terminal description
Functional
Port Instructions
description
15V/24V 15V/24V power output 200mA15V/24V output

X6
Input port6 Short Port X6 and COM , input signal
(Reversing switch) effective

X5
Input port 5 (Reverse Short Port X5 and COM , input signal
rotation Control switch) effective

X4
Input port 4(Forward Short Port X4 and COM , input signal
rotation Control switch) effective

X3
Input port 3(section- Short Port X3 and COM , input signal
speed 3) effective
X2
Input port 2(section- Short Port X2 and COM , input signal
speed 2) effective
X1
Input port 1(section- Short Port X1 and COM , input signal
speed 1) effective
485+/485- 485 communication port

3页
Functional
Port Instructions
description
COM Common GND
External analog voltage 0-5V/10V Analog voltage input
VL1 input
External current signal
CI 4-20mA Current input
input

SP1 Open-collector output 1

SP2 Open-collector output 2

5V/10V 5V/10V power output supply 5V/10V 20mA power output

TC Relay output C
250VAC 5A/30VDC 3A
TB Relay output B TA and TB Normal Close ,TA and TC
Normal Open
TA Relay output A

3. Multi-speed input Frequency control table :


Section Section Section Original
speed input 1 speed input 2 speed input 3 Frequency

Main Speed 1 1 1 50
Section speed 1 1 1 0 45
Section speed 2 1 0 1 40
Section speed 3 1 0 0 35
Section speed 4 0 1 1 30
Section speed 5 0 1 0 25
Section speed 6 0 0 1 20
Section speed 7 1 1 1 15
0 means input Port connect with COM, 1 means
Note :
disconnect.

4页
4. Basic operation wiring diagram
(1) Single-phase input three-phase output (for AT1 )
(Three phase 220V, if 380V Star-connection method
needs to change to the 220V Delta-connection method)

5页
(2). Single-phase input and output (for AT2)
(220V single phase motor, Non-removed capacitor
/ Removed capacitor)

6页
(3). Three-phase input and output (for AT3)
(380V three phase input, connect with 380V three
phase motor)

7页
5. Operation panel

8页
6. Keys instructions

Icon Function description

For selecting mode or Programming mode (it is


(Programming) available not mater the Inverter start or stop),
1
press this key for modifying parameters.

Function data setting key. Normal mode: press


this key to display the information of the
(Function / Save)
2 Inverter, such as target frequency, output
frequency and current, temperature;

Parameter
Key number or
3 Short press this key, then
(▲) parameter value
the numerical value will
increase change gradually. Long
Parameter press this key, then the
Key number or numerical value will change
4 rapidly
(▼) parameter value
decrease
5 Shift Shift in programming mode, jog in normal mode
6 Forward / Reverse Forward / Reverse switching key
7 Start Start Inverter output
8 Stop / Reset Break down, fault resetting
Please modify the parameters under the stop state, otherwise, the
Note changed parameters cannot be saved.

9页
Chapter 2 Parameter specification
1. Parameter specification
Paramet Parameter
Parameter range Default Unit
er specification

P00 Maximum voltage 0---220.0/380.0 220/380 V

P01 Reference frequency 0---400.0 50 Hz

P02 Intermediate voltage 0---220.0/380.0 110/190 V

Intermediate
P03 0---400.0 25 Hz
frequency

P04 Minimum voltage 0---220.0/380.0 0 V

P05 Minimum frequency 0---400.0 0 Hz

P06 Maximum operating 0---400.0 100 Hz

P07 Minimum operating 0---400.0 0 Hz

P08 Hide password 0---65535 33333

P09 Input password 0---65535 0

0: Panel keyboard;
Working frequency 1: Panel potentiometer;
P10 1
source 2: External analog signal
3: RS485.

Start/stop 0: Panel keyboard;


P11 control source 1: RS485; 0
2: External port.

10 页
0: Inertial stop;

P12 1: Deceleration stop; 1


Stopping Modes
2: Brake stop;
3: Emergency brake.
P13 Braking time 0---2.5 0.5 S
P14 Braked Voltage 0---140.0 20 V
P17 Machine number 1-255 1

P18 Operating arrival 0---100.0 50 Hz


Over temperature protection
P20 1---80 80
selection
P21 Revolution for 50Hz 0-8000 2800
P22 Carrier setting 1---10 (1-20 for High Ver) 10
Frequency adjusting step
P23 size 1---100 5 0.1Hz
Overload protection buffer
P24 0.1---60.0 3 S
time
P26 Working frequency 0---400.0 50 Hz

P27 Section speed 1 setting 0---400.0 45 Hz


P28 Section speed 2 setting 0---400.0 40 Hz
P29 Section speed 3 setting 0---400.0 35 Hz
P30 Section speed 4 setting 0---400.0 30 Hz
P31 Section speed 5 setting 0---400.0 25 Hz
P32 Section speed 6 setting 0---400.0 20 Hz

11 页
P33 Section speed 7 setting 0---400.0 15 Hz
P34 Main rising velocity 1---1000 50 Hz/S
P35 1st rising velocity 1---1000 50 Hz/S
P36 2nd rising velocity 1---1000 50 Hz/S
P37 3rd rising velocity 1---1000 50 Hz/S
P38 4th rising velocity 1---1000 50 Hz/S
P39 5th rising velocity 1---1000 50 Hz/S
P40 6th rising velocity 1---1000 50 Hz/S
P41 7th rising velocity 1---1000 50 Hz/S
P42 Main descent velocity 1---1000 25 Hz/S
P43 1st descent velocity 1---1000 50 Hz/S
P44 2nd descent velocity 1---1000 50 Hz/S
P45 3rd descent velocity 1---1000 50 Hz/S
P46 4th descent velocity 1---1000 50 Hz/S
P47 5th descent velocity 1---1000 50 Hz/S
P48 6th descent velocity 1---1000 50 Hz/S
P49 7th descent velocity 1---1000 50 Hz/S

0: invalid, terminal is
non-functioning
1: wire control stop
P50 Multi function input 1
(X1 binding post) 2: keying stop;
3: keying operation;
4: stop keying;

12 页
P50 Multi function input 1 13
(X1 binding post)
P51 Multi function input 2 14
P52 Multi function input 3 5: wire forward operation 15
P53 Multi function input 4 6: wire reverse operation; 5
P54 Multi function input 5 7: reservation 6
8: error reset signal;
9: wire reversing switch;
10: keying forward switching;
11: keying forward switching;
12: reverse switch keying;
13: section speed input 1;
14: section speed input 2;
15: section speed input 3;
P55 Multi function input 6 16: external error signal. 9
17: Jog Forward;
18: Jog Reverse;
19: Emergency stop;
20: Relay Control.

0: invalid, no output;
1: operating instructions;
Multi function input 1 2: set arrival instructions 0
P58 3: fault indication;
(SP1)
5: Emergency stop;
6: For P50-P55=20;
P60 Multi function input 2 Idem (Relay output) 0
0: setting frequency;
1: operating frequency;
P62 Display options 0 13 页
2: revolution 3: current;
0: normal power on;
1: report error with start signal when
power on; 0
P65 Power on options
2: Power on forward;
3: Power on reverse.
P66 Input stabilization time 0---65535 60 mS

P67 Voltage coefficient 0---65535 28500


P68 Under voltage setting 0---220/380 60/180 V
P69 Overvoltage setting 220.0---400/680 400/600 V
0: P72 is compensation amount;
P70 Torque compensation 1: Multiply P72 by P71 after P71 0
options minus input voltage
Torque compensation
P71 0---300.0 10 V
voltage
Torque compensation
P72 0---100 0
setting
Maximum external
P73 31440
analog 0---65535
Minimum external
P74 2096
analog 0---65535
Zero current 1130
P75 0---65535
compensation value
9500
P76 Current coefficient 0---65535
0---65535
P77 Parameter reset 0
(It is the reset when 54321 )
P86 Jog forward frequency 0---400.0 20 Hz
P87 Jog reverse frequency 0---400.0 20 Hz
P88 Jog rising velocity 1---1000 50 Hz/S
P89 Jog descent velocity 1---1000 50 Hz/S

14 页
0: Inertia stop;
1: Decelerate stop;
P90 Jog stopping modes
2: Braking stop; 1
3: Emergency brake.
P91 Jog braking time 0---2.5 0.1 S
P127 Remaining hours 0---65535 65535 H

2. Parameter setting password and Down time


stop:
P08 is the hidden password, it always shows only 00000, not the actual
value.
When input the value of P09=the hidden value of P08, the P08 shows
hidden value, and the P08 and other parameters can be changed. The
P09 will be nullified when unplug the power cable to restart.

When P127=65535, the function of countdown do not start.


When P127﹤65535, the function of countdown will start, the P127 65535, the function of countdown will start, the P127
will minus 1 when the Inverter runs for one hour. The frequency
converter will be stopped when the countdown of P127 to 0 hour.

15 页
4. Parameter setting procedure:
1. Press the programming key to enter into the programming
state;
2. Use the arrow keys and shift key to find the parameters that
need to be modified;
3. Press function / save key to enter into the parameter;
4. Use the arrow keys and shift key to amend the parameter value;
5. Press the function / save key to store the parameter;
6. Press the programming key to exit the programming state.

Chapter 4 Fault Code


Fault Code Display Fault Code Description
Short Circuit/Current overload/Power
Err 1
Module protection

Err 2 Undervoltage protection

Err 3 Overvoltage protection

Err 4 Driving Circuit Failures

Err 5 Input at startup when electrified

Err 6 Over current protection

Err 7 Overtime

Err 8 Excessive temperatures for radiator

Err 9 External fault


16 页