GXR Series
High
High Frequency
PerformanceX-ray
and Generator
Reliability

Superior performance and stability

Features
• Fully Automatic mA/kV Calibration
• Easy parameter setting and firmware upgrade
• System self-diagnosis function
• System quality maintenance via Remote Diagnosis
• Real time monitoring self diagnosis and error code display
• Remote Diagnosis via internet reduces service cost and down time
• Tube overloading and housing overheating protection
• User-programmable anatomical programs with APR Utility
• Dual speed starter : Direct drive by 6-pack IPM circuit, dynamic brake

Options

• AEC (Automatic Exposure Control) Interface


• DR (Digital Radiography) Interface: SDK, PC interface module, Signal interface
• Pedestal Console Stand
• 23” Touch Screen Console
Touch Screen X-ray Control Console

2460
www.drgem.co.kr

Specification
Model GXR-32 GXR-40 GXR-52 GXR-68 GXR-82
Output Rating 32kW 40kW 52kW 68kW 82kW

230VAC, 1Ф
Line Nominal, Phase 400/480VAC, 3Ф
400/480VAC, 3Ф

±10% (Frequency: 50*/60Hz)


Line Voltage Range
*Outside North America

40~125kV, 1kV step


kV Range 40~150kV, 1kV step
Optional 40~150kV

10 to 400mA
mA Range 10 to 500mA 10 to 640mA 10 to 800mA 10 to 1,000mA
Optional 500mA

Timer Range 0.001 to 10 sec, 38 steps

mAs Range 0.1 to 500mAs (Optional higher mAs)

400mA@80kV 500mA@80kV 640mA@81kV 800mA@85kV 1,000mA@82kV


320mA@100kV 400mA@100kV
Max. 500mA@104kV 640mA@106kV 800mA@102kV
Power Output 250mA@125kV 320mA@125kV
400mA@130kV 500mA@136kV 640mA@128kV
125mA@150kV(1Ф) 160mA@150kV(1Ф)
200mA@150kV(3Ф) 250mA@150kV(3Ф) 320mA@150kV 400mA@150kV 500mA@150kV

Low Speed
Rotor Supply Dual Speed (Option for GXR - 52)
Dual Speed (Option for 3Ф)

Reproducibility Coefficient of Variation: kV<0.005, Time<0.005, mAs<0.01

Accuracy kV < ±(1%+1kV), mA < ±(3%+1mA), Time < ±(1%+0.5ms), mAs < ±(3%+0.1mAs)

Linearity Coefficient of Linearity < 0.01 : CL = (X1 X2)/(X1+X2), where X is mR/mAs

Anatomical Programs User Programmable max. 1,280 programs with APR utility software

Technique Selection 4 point display (kV, mA, Time, mAs)

Image Receptors 2 Bucky + 1 Non-Bucky

230VAC, 1A, 230W


External System Power
Auxiliary 110VAC, 1A, 110W
Power Supply Magnetic Lock Power 28VDC, 5A, 140W

Collimator Lamp Power 24VAC, 6.3A, 150W

Dimension Unit: mm (Inch)


366
(14.4)
(9.13)
232
(24.4)
620

(37.0)
940
(32.9)
835
(24.8)

(25.8)
630

655

108 295 304


405 620
(4.25) (11.6) (12.0)
(15.9) (24.4)

Specifications and features are subject to change without notice.


All changes will be in compliance with regulations governing manufacture of medical equipment.

7Fl, E-B/D Gwangmyeong Techno-Park, 60 Haan-ro, Gwangmyeong-si, Gyeonggi-do, Korea [14322]


TEL : +82-2-869-8566 / FAX : +82-2-869-8567 / www.drgem.co.kr / [email protected] RCT1401-001, R3