STAT FAX 4500


Programmable open system Biochemistry Analyzer

Stat Fax 4500 is a compact, standalone


chemistry analyzer with built-in 12 station
incubation, on-board printer, and
touchscreen.

• Performs endpoint and kinetic assays using standards or factors Stat Fax® 4500 has been updated and
improved, the same reliability you have
• User programmable menu for routine chemistries such as cardiac,
come to expect with an improved graphical
liver, kidney, and metabolic function tests interface and high resolution capacitive
touchscreen similar to those found on
• Reads 12mm tubes, 1 cm square cuvettes, or with a flowcell
today’s smart phones. Response times are
• Bichromatic photometer with 6 filters ranging from 340 nm to 700 nm faster, selections take place almost instantly,
the glass surface is easier to clean and the
• Stores 500 test results
processor has been updated resulting in an
• Stores 1000 control results overall performance boost improving the user
experience.

Updated interface for easy navigation Simple to use graphically driven utilities High resolution capacitive touch display
Stat Fax® 4500 Biochemistry Analyzer

Speed Reads, calculates and prints results, 3 seconds per tube.

Linear Measurement Range 0.0 to 3.0 Absorbance units (A)


Photometric Accuracy +/- (1% +/- 0.010) 0.0 through 1.5 ABS
+/- (2% +/- 0.010) 1.5 through 3.0 ABS

Stability Drift of no more than 0.005A in 8 hours/bichromatic.


Light Source Xenon-Halogen with lamp saver feature
Standard Wavelengths 340, 405, 505, 545, 580 and 630nm
(alternate filters available from 340 to 700nm, a maximum of
8 filters installed must be custom manufactured)
Filter Type IAD hardcoat interference, 10nm half bandpass

Tube Size 12 mm round tube is standard


Read cell accommodates square cuvettes

Minimum sample volume 1 ml for 12mm round tube


250µL for flowcell

Display Interactive capacitive touch-screen 3.5” LCD, color graphic display


Printer Thermal dot matrix, with graphic capability
Power Requirements 110-240 VAC ~ 50/60Hz

Calculation Modes Single point calibration by standard or factor, multipoint


calibration with point-to-point curve fit, rate by standard
or factor (batch or singly)

Test Menu Store up to 140 programmed tests


Stores all parameters including wavelengths, calculations,
unit codes, linear and normal ranges, rate timing, standard
values, test names and previous standard curve

Special software features Levey-Jennings Q.C. Real-time kinetics


Temperature control Read cell and incubation block, 37˚C or off
Enclosure Painted flame-retardant ABS plastic cover and base
Dimensions Approx. 9x13.5x5in. (24x34x13cm) weighs 10 lbs.(4.5kg)
Certifications NRTL listed, CE mark
ISO 13485:2016

www.awaretech.com
Awareness Technology, Inc. USA & International
tel: +1 772 283 6540 [email protected]
www.gmi-inc.com
Awareness Technology, Inc. Europe
314500E

tel: +43 (0) 2236 892465 [email protected]


[email protected]
Awareness Technology, Inc. Asia & Africa Redi-Check® photometer check set, to monitor the
(763) 712-8717
tel: +971 (06) 557 80 58 [email protected] accuracy, linearity, and repeatability of Chemistry Analyzers

You might also like